Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Front Oncol ; 14: 1365897, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835389

RESUMO

Background: Acute hematologic toxicity (HT) is a prevalent adverse tissue reaction observed in cervical cancer patients undergoing chemoradiotherapy (CRT), which may lead to various negative effects such as compromised therapeutic efficacy and prolonged treatment duration. Accurate prediction of HT occurrence prior to CRT remains challenging. Methods: A discovery dataset comprising 478 continuous cervical cancer patients (140 HT patients) and a validation dataset consisting of 205 patients (52 HT patients) were retrospectively enrolled. Both datasets were categorized into the CRT group and radiotherapy (RT)-alone group based on the treatment regimen, i.e., whether chemotherapy was administered within the focused RT duration. Radiomics features were derived by contouring three regions of interest (ROIs)-bone marrow (BM), femoral head (FH), and clinical target volume (CTV)-on the treatment planning CT images before RT. A comprehensive model combining the radiomics features as well as the demographic, clinical, and dosimetric features was constructed to classify patients exhibiting acute HT symptoms in the CRT group, RT group, and combination group. Furthermore, the time-to-event analysis of the discriminative ROI was performed on all patients with acute HT to understand the HT temporal progression. Results: Among three ROIs, BM exhibited the best performance in classifying acute HT, which was verified across all patient groups in both discovery and validation datasets. Among different patient groups in the discovery dataset, acute HT was more precisely predicted in the CRT group [area under the curve (AUC) = 0.779, 95% CI: 0.657-0.874] than that in the RT-alone (AUC = 0.686, 95% CI: 0.529-0.817) or combination group (AUC = 0.748, 95% CI: 0.655-0.827). The predictive results in the validation dataset similarly coincided with those in the discovery dataset: CRT group (AUC = 0.802, 95% CI: 0.669-0.914), RT-alone group (AUC = 0.737, 95% CI: 0.612-0.862), and combination group (AUC = 0.793, 95% CI: 0.713-0.874). In addition, distinct feature sets were adopted for different patient groups. Moreover, the predicted HT risk of BM was also indicative of the HT temporal progression. Conclusions: HT prediction in cervical patients is dependent on both the treatment regimen and ROI selection, and BM is closely related to the occurrence and progression of HT, especially for CRT patients.

2.
J Appl Clin Med Phys ; : e14371, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38682540

RESUMO

PURPOSE: To create and evaluate a three-dimensional (3D) Prompt-nnUnet module that utilizes the prompts-based model combined with 3D nnUnet for producing the rapid and consistent autosegmentation of high-risk clinical target volume (HR CTV) and organ at risk (OAR) in high-dose-rate brachytherapy (HDR BT) for patients with postoperative endometrial carcinoma (EC). METHODS AND MATERIALS: On two experimental batches, a total of 321 computed tomography (CT) scans were obtained for HR CTV segmentation from 321 patients with EC, and 125 CT scans for OARs segmentation from 125 patients. The numbers of training/validation/test were 257/32/32 and 87/13/25 for HR CTV and OARs respectively. A novel comparison of the deep learning neural network 3D Prompt-nnUnet and 3D nnUnet was applied for HR CTV and OARs segmentation. Three-fold cross validation and several quantitative metrics were employed, including Dice similarity coefficient (DSC), Hausdorff distance (HD), 95th percentile of Hausdorff distance (HD95%), and intersection over union (IoU). RESULTS: The Prompt-nnUnet included two forms of parameters Predict-Prompt (PP) and Label-Prompt (LP), with the LP performing most similarly to the experienced radiation oncologist and outperforming the less experienced ones. During the testing phase, the mean DSC values for the LP were 0.96 ± 0.02, 0.91 ± 0.02, and 0.83 ± 0.07 for HR CTV, rectum and urethra, respectively. The mean HD values (mm) were 2.73 ± 0.95, 8.18 ± 4.84, and 2.11 ± 0.50, respectively. The mean HD95% values (mm) were 1.66 ± 1.11, 3.07 ± 0.94, and 1.35 ± 0.55, respectively. The mean IoUs were 0.92 ± 0.04, 0.84 ± 0.03, and 0.71 ± 0.09, respectively. A delineation time < 2.35 s per structure in the new model was observed, which was available to save clinician time. CONCLUSION: The Prompt-nnUnet architecture, particularly the LP, was highly consistent with ground truth (GT) in HR CTV or OAR autosegmentation, reducing interobserver variability and shortening treatment time.

3.
Health Phys ; 124(4): 310-315, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649541

RESUMO

ABSTRACT: The purpose of this paper is to describe the status of radiation-generating medical devices in mainland China. The number of diagnostic radiology and interventional radiology devices was collected from the national medical radiation protection monitoring information system, while the number of radiation therapy and nuclear medicine devices was from the published articles. Statistical analysis of the correlation was used to assess the relationship between the number of high technology medical devices and GDP per capita. A total of 143,064 radiation-generating medical devices were identified in mainland China, and diagnostic radiology devices accounted for 94% of those. The number of CTs was 14.84 per million, an increase by a factor of 1.45 compared to 2009. But the distribution of CTs was imbalanced among different areas: the highest number of CT per million population was 27.70 in Tibet, and the lowest was 8.55 per million population in Guangxi province. Statistical analysis of the correlation showed that the number of PET scanners per million population was positively correlated with GDP per capita, and similarly for medical accelerators. The number of mammographic devices per million population was much lower than that in other countries. The investment of radiation-generating medical devices in China was far from enough, especially for mammographic devices. More efforts should be taken to bring medical resources to regions with greater population areas in the future.Health Phys. 124(0):000-000; 2023.


Assuntos
Medicina Nuclear , Monitoramento de Radiação , China , Radiografia , Radiologia Intervencionista
4.
Biosensors (Basel) ; 12(10)2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36290940

RESUMO

Listeria monocytogenes is a hazardous foodborne pathogen that is able to cause acute meningitis, encephalitis, and sepsis to humans. The efficient detection of 3-hydroxy-2-butanone, which has been verified as a biomarker for the exhalation of Listeria monocytogenes, can feasibly evaluate whether the bacteria are contained in food. Herein, we developed an outstanding 3-hydroxy-2-butanone gas sensor based on the microelectromechanical systems using Au/ZnO NS as a sensing material. In this work, ZnO nanosheets were synthesized by a hydrothermal reaction, and Au nanoparticles (~5.5 nm) were prepared via an oleylamine reduction method. Then, an ultrasonic treatment was carried out to modified Au nanoparticles onto ZnO nanosheets. The XRD, BET, TEM, and XPS were used to characterize their morphology, microstructure, catalytic structure, specific surface area, and chemical composition. The response of the 1.0% Au/ZnO NS sensors vs. 25 ppm 3-hydroxy-2-butanone was up to 174.04 at 230 °C. Moreover, these sensors presented fast response/recovery time (6 s/7 s), great selectivity, and an outstanding limit of detection (lower than 0.5 ppm). This work is full of promise for developing a nondestructive, rapid and practical sensor, which would improve Listeria monocytogenes evaluation in foods.


Assuntos
Nanopartículas Metálicas , Materiais Inteligentes , Óxido de Zinco , Humanos , Óxido de Zinco/química , Ouro , Acetoína , Biomarcadores
5.
PeerJ ; 10: e12871, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35178302

RESUMO

BACKGROUND: Laryngeal squamous cell carcinoma (LSCC) remains one of the most common respiratory tumors worldwide. Baculoviral inhibitor of apoptosis repeat containing 5 (BIRC5) is a member of the inhibitor-of-apoptosis protein family. BIRC5 plays an important role in various types of cell proliferation, differentiation, migration and invasion. However, the specific role of BIRC5 in LSCC remains unclear. METHODS: To provide a prognostic biomarker for LSCC, we screened the prognostic genes of LSCC via bioinformatics. PPI network and KEGG pathways were used to select hub genes. Clinical prognoses were performed using a Kaplan-Meier plotter and Cox proportional-hazard analysis. BIRC5 expression in LSCC tissues and cell lines were detected by RT-PCR, Western blot and Immunohistochemistry (IHC). Cell proliferation, cell cycle and cell apoptosis were detected with Cell Counting Kit-8 (CCK-8) and Flow Cytometry assay, respectively. RESULTS: Here, BIRC5 was strongly correlated with higher tumor grade and differentiation. BIRC5 was highly expressed in LSCC tissues when compared with normal tissues and increased expression of BIRC5 was associated with overall survival in LSCC patients. The suppression of BIRC5 induced cell apoptosis and cell cycle arrest, thereby inhibiting the proliferation of LSCC cells. The survival analysis confirmed that higher level of BIRC5 expression predicted poor prognosis of LSCC patients. BIRC5 may act as an oncogene of LSCC development and was suggested as a promising prognostic biomarker for LSCC.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Laríngeas , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética , Neoplasias Laríngeas/genética , Carcinoma de Células Escamosas/genética , Prognóstico , Processos Neoplásicos , Biomarcadores , Survivina/genética
6.
Onco Targets Ther ; 14: 2829-2838, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33935503

RESUMO

INTRODUCTION: Aberrant circular RNA (circRNA) expression has been extensively discovered for its involvement in both the initiation and progression of various cancers. Through screening circRNA profile, we identified a novel circRNA has_circ_0001806, which is termed as circCSPP1 in liver cancer. In the present study, we aim to investigate the role of circCSPP1 in the progression of liver cancer. METHODS: Fluorescence in situ hybridization (FISH) was used to detect the location of circCSPP1. Function studies including MTT, colony formation assay, transwell assay and flow cytometry were carried out to detect the malignant behaviour of circCSPP1 on liver cancer cells. Luciferase assay and RNA pull down were used to detect the interaction between miR-1182 and circCSPP1 as well as RAB15. Quantitative realtime (qPCR) and Western blot were performed to evaluate the RNA and protein expression, respectively. RESULTS: CircCSPP1 knockdown inhibited the proliferation, migration and invasion while promoted apoptosis of liver cancer cells. Mechanically, we predicted and verified the target miR of circCSPP1 which is miR-1182. miR-1182 was capable of reversing the effect of circCSPP1 on liver cancer cells. Moreover, miR-1182 was found to also target RAB15 to participate in the regulation of cell phenotype. DISCUSSION: Taken together, circCSPP1 promoted progression of liver cancer cells via sponging miR-1182 which may serve as a novel prognostic and therapeutic target for liver cancer.

7.
Radiat Oncol ; 11: 30, 2016 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-26921246

RESUMO

PURPOSE: Through the Monte Carlo (MC) simulation of 6 and 10 MV flattening-filter-free (FFF) beams from Varian TrueBeam accelerator, this study aims to find the best incident electron distribution for further studying the small field characteristics of these beams. METHODS: By incorporating the training materials of Varian on the geometry and material parameters of TrueBeam Linac head, the 6 and 10 MV FFF beams were modelled using the BEAMnrc and DOSXYZnrc codes, where the percentage depth doses (PDDs) and the off-axis ratios (OARs) curves of fields ranging from 4 × 4 to 40 × 40 cm(2) were simulated for both energies by adjusting the incident beam energy, radial intensity distribution and angular spread, respectively. The beam quality and relative output factor (ROF) were calculated. The simulations and measurements were compared using Gamma analysis method provided by Verisoft program (PTW, Freiburg, Germany), based on which the optimal MC model input parameters were selected and were further used to investigate the beam characteristics of small fields. RESULTS: The Full Width Half Maximum (FWHM), mono-energetic energy and angular spread of the resultant incident Gaussian radial intensity electron distribution were 0.75 mm, 6.1 MeV and 0.9° for the nominal 6 MV FFF beam, and 0.7 mm, 10.8 MeV and 0.3° for the nominal 10 MV FFF beam respectively. The simulation was mostly comparable to the measurement. Gamma criteria of 1 mm/1 % (local dose) can be met by all PDDs of fields larger than 1 × 1 cm(2), and by all OARs of no larger than 20 × 20 cm(2), otherwise criteria of 1 mm/2 % can be fulfilled. Our MC simulated ROFs agreed well with the measured ROFs of various field sizes (the discrepancies were less than 1 %), except for the 1 × 1 cm(2) field. CONCLUSIONS: The MC simulation agrees well with the measurement and the proposed model parameters can be clinically used for further dosimetric studies of 6 and 10 MV FFF beams.


Assuntos
Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Elétrons , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Fótons/uso terapêutico , Software
8.
Radiat Oncol ; 10: 28, 2015 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-25623899

RESUMO

PURPOSE: To compare the dosimetric differences between jaw tracking technique (JTT) and static jaw technique (SJT) in dynamic intensity-modulated radiotherapy (d-IMRT) and assess the potential advantages of jaw tracking technique. METHODS: Two techniques, jaw tracking and static jaw, were used respectively to develop the d-IMRT plans for 28 cancer patients with various lesion sites: head and neck, lungs, esophageal, abdominal, prostate, rectal and cervical. The dose volume histograms (DVH) and selected dosimetric indexes for the whole body and for organs at risk (OARs) were compared. A two dimensional ionization chamber Array Seven29 (PTW, Freiburg, Germany) and OCTAVIUS Octagonal phantom (PTW, Freiburg, Germany) were used to verify all the plans. RESULTS: For all patients, the treatment plans using both techniques met the clinical requirements. The V5, V10, V20, V30, V40 (volumes receiving 5, 10, 20, 30 and 40 Gy at least, respectively), mean dose (Dmean) for the whole body and V5, V10, V20, Dmean for lungs in the JTT d-IMRT plans were significantly less than the corresponding values of the SJT d-IMRT plans (p < 0.001). The JTT d-IMRT plans deposited lower maximum dose (Dmax) to the lens, eyes, brainstem, spinal cord, and right optic nerve, the doses reductions for these OARs ranged from 2.2% to 28.6%. The JTT d-IMRT plans deposited significantly lower Dmean to various OARs (all p values < 0.05), the mean doses reductions for these OARs ranged from 1.1% to 31.0%, and the value reductions depend on the volume and the location of the OARs. The γ evaluation method showed an excellent agreement between calculation and measurement for all techniques with criteria of 3%/3 mm. CONCLUSIONS: Both jaw tracking and static jaw d-IMRT plans can achieve comparable target dose coverage. JTT displays superior OARs sparing than SJT plans. These results are of clinical importance, especially for the patients with large and complex targets but close to some highly radio-sensitive organs to spare, and for patients with local recurrent or secondary primary malignant lesion within a previously irradiated area.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Registro da Relação Maxilomandibular/métodos , Arcada Osseodentária/efeitos da radiação , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Arcada Osseodentária/fisiologia , Registro da Relação Maxilomandibular/instrumentação , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Órgãos em Risco/efeitos da radiação , Radiometria/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos
9.
J Am Soc Mass Spectrom ; 22(7): 1294-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21953112

RESUMO

In this Application Note, we describe, for the first time, the rapid analysis of hydrophobic compounds present in environmental contaminants, which includes polycyclic aromatic hydrocarbons (PAHs) and estrogen, by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with the use of graphene as matrix. MALDI-TOF MS with conventional matrix has limitations in analyzing low-polarity compounds owing to their difficulty in ionization. We demonstrate that compared with conventional matrix, graphene displays higher desorption/ionization efficiencies for PAHs, and no fragment ions are observed. The method also holds potential in quantitative analysis. In addition, the ionization signal increases with the increasing number of benzene rings in the PAHs, suggesting that graphene binds to PAHs via π-π stacking interactions. Furthermore, graphene as adsorbent for solid-phase extraction of coronene from river water sample displays good performance with a detection limit of 10(-7) M. This work provides a novel and convenient method for analyzing low-polarity environmental contaminants by MALDI-TOF MS.


Assuntos
Grafite/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Poluentes Químicos da Água/análise , Estrogênios/análise , Interações Hidrofóbicas e Hidrofílicas , Compostos Policíclicos/análise , Rios/química , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
10.
Anal Chem ; 82(14): 6208-14, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20565059

RESUMO

Graphene was utilized for the first time as a matrix for the analysis of low molecular weight compounds using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Polar compounds including amino acids, polyamines, anticancer drugs, and nucleosides could be successfully analyzed. Additionally, nonpolar compounds including steroids could be detected with high resolution and sensitivity. Compared with a conventional matrix, graphene exhibited a high desorption/ionization efficiency for nonpolar compounds. The graphene matrix functions as a substrate to trap analytes, and it transfers energy to the analytes upon laser irradiation, which allows for the analytes to be readily desorbed/ionized and interference of intrinsic matrix ions to be eliminated. The use of graphene as a matrix avoided the fragmentation of analytes and provided good reproducibility and a high salt tolerance, underscoring the potential application of graphene as a matrix for MALDI MS analysis of practical samples in complex sample matrixes. We also demonstrated that the use of graphene as an adsorbent for the solid-phase extraction of squalene could improve greatly the detection limit. This work not only opens a new field for applications of graphene, but also offers a new technique for high-speed analysis of low molecular weight compounds in areas such as metabolism research and natural product characterization.


Assuntos
Carbono/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Aminoácidos/análise , Antineoplásicos/análise , Nucleosídeos/análise , Poliaminas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA