Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 52(2): 150-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27302284

RESUMO

OBJECTIVES: Long-term durability after endovascular aortic repair is influenced by stent graft migration causing types I and III endoleaks. Flow induced displacement forces have been shown to have the potential to cause migration. In this study, the influence of the distal diameter of iliac limb stent grafts and the shape of graft curvature on flow induced displacement forces, were investigated. METHODS: In an experimental pulsatile flow model mimicking aortic conditions in vivo, flow induced displacement forces at the proximal and distal ends of iliac limb stent grafts were studied at different angles (0-90°) and perfusion pressures (145/80, 170/90, 195/100 mmHg). Bell-bottomed, tapered, and non-tapered stent grafts and also asymmetric stent graft curvatures at 90° bend were studied. Measurements of graft movement were performed at all studied angulations and graft shapes. RESULTS: For all stent graft diameters, flow induced displacement forces increased with higher pressure and increased stent graft angulation. Forces in the bell-bottom graft were considerably higher than in tapered and non-tapered grafts, with a markedly elevated peak force at the distal end (proximal end, 2.3 ± 0.06 N and distal end, 6.9 ± 0.05 N compared with 1.7 ± 0.08 N and 1.6 ± 0.08 N in non-tapered grafts; p < .001 both). Peak forces in tapered and non-tapered grafts were not significantly different between the proximal and distal end. In asymmetric stent graft curvatures, a significant increase in displacement forces was observed in the attachment zone that was closest to the stent graft bend. Graft movement increased with greater displacement forces. CONCLUSION: Flow induced displacement forces in iliac limb stent grafts are significant and are influenced by distal stent graft diameter and the shape of the graft curvature. The displacement forces are particularly high at the large distal end of bell-bottom grafts. Wide iliac arteries treated with bell-bottom stent grafts may require more vigilant surveillance and improved stent graft fixation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Enxerto Vascular/efeitos adversos , Velocidade do Fluxo Sanguíneo , Endoleak/etiologia , Migração de Corpo Estranho/etiologia , Humanos , Artéria Ilíaca/cirurgia , Modelos Biológicos
2.
Eur J Vasc Endovasc Surg ; 47(3): 262-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24445085

RESUMO

OBJECTIVES: Stent graft migration influences the long-term durability of endovascular aortic repair. Flow-induced displacement forces acting on the attachment zones may contribute to migration. Proximal fixation of aortic stent grafts has been improved by using hooks, while distal fixation and stent graft interconnections depend on self-expansion forces only. We hypothesized that flow-induced displacement forces would be significant at the distal end, and would correlate with graft movements. METHODS: As part of an experimental study, an iliac limb stent graft was inserted in a pulsatile flow model similar to aortic in vivo conditions, and fixed-mounted at its proximal and distal ends to strain gauge load cells. Peak displacement forces at both ends and pulsatile graft movement were recorded at different graft angulations (0-90°), perfusion pressures (145/80, 170/90, or 195/100 mmHg), and stroke frequencies (60-100 b.p.m.). RESULTS: Flow-induced forces were of the same magnitude at the proximal and distal end of the stent graft (peak 1.8 N). Both the forces and graft movement increased with angulation and perfusion pressure, but not with stroke rate. Graft movement reached a maximum of 0.29 ± 0.01 mm per stroke despite fixed ends. There were strong correlations between proximal and distal displacement forces (r = 0.97, p < .001), and between displacement forces and graft movement (r = 0.98, p < .001). CONCLUSIONS: Pulsatile flow through a tubular untapered stent graft causes forces of similar magnitude at both ends and induces pulsatile graft movements in its unsupported mid-section. Peak forces are close to those previously reported to be required to extract a stent graft. The forces and movements increase with increasing graft angulation and perfusion pressure. Improved anchoring of the distal end of stent grafts may be considered.


Assuntos
Prótese Vascular , Migração de Corpo Estranho/fisiopatologia , Fluxo Pulsátil , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares , Humanos , Artéria Ilíaca/fisiopatologia , Modelos Cardiovasculares , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA