Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Clin Microbiol Infect Dis ; 43(3): 423-433, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112966

RESUMO

PURPOSE: Anaerobic bacteria, existing on human skin and mucous membranes, can cause severe infections with complications or mortality. We examined the clinical characteristics of patients infected with Fusobacterium spp. and assessed their antibiotic susceptibility. METHODS: Clinical data were collated from patients diagnosed with Fusobacterium infections in a Japanese university hospital between 2014 and 2023. Antibiotic susceptibility tests were conducted following the Clinical and Laboratory Standards Institute guidelines. RESULTS: We identified 299 Fusobacterium isolates. The median age was 61 years (range, 14-95 years), with females constituting 43.1% of the patients. Most infections were community-acquired (84.6%, 253/299). Multiple bacterial strains were isolated simultaneously in 74.6% of cases. One-fourth of the patients had solid organ malignancies (25.4%, 76/299), and 14.5% (11/76) of those had colorectal cancer. The 30-day mortality rate was 1.3%. Fusobacterium species were isolated from blood cultures in 6% (18/299) of the patients. Patients, aged 75 years or older, with cerebrovascular disease or hematologic malignancy exhibited significantly higher prevalence of blood culture isolates in univariate analysis. Each Fusobacterium species had its characteristic infection site. Approximately 5% F. nucleatum and F. necrophorum isolates showed penicillin G resistance. Moxifloxacin resistance was observed in varying degrees across strains, ranging from 4.6 to 100% of isolates. All isolates were sensitive to ß-lactam/ß-lactamase inhibitors, carbapenems, and metronidazole. CONCLUSION: We show a link between Fusobacterium species and solid organ malignancies. We observed resistance to penicillin, cefmetazole, clindamycin, and moxifloxacin, warranting caution in their clinical use. This study offers valuable insights for managing Fusobacterium infections and guiding empirical treatments.


Assuntos
Infecções por Fusobacterium , Neoplasias , Feminino , Humanos , Pessoa de Meia-Idade , Fusobacterium , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Moxifloxacina , Japão/epidemiologia , Testes de Sensibilidade Microbiana , Infecções por Fusobacterium/epidemiologia , Infecções por Fusobacterium/microbiologia , Hospitais
2.
J Infect Chemother ; 27(7): 1039-1042, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33840598

RESUMO

INTRODUCTION: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 antigen test (LUMIPULSEⓇ) was licensed and widely used in Japan since May 2020. We conducted this study intending to whether the automated quantitative CLEIA antigen test using a saliva sample is effective and valid for the diagnosis of COVID-19. PATIENTS AND METHODS: We analyzed and compared the diagnostic accuracy of both the automated quantitative CLEIA antigen test and real-time RT-PCR (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. RESULTS: A total of 305 samples were collected and tested in Aichi Medical University Hospital and affiliated facilities from December 2020 until January 2021 at our institute. Using reverse-transcription PCR as a reference, the AUROC of the automated quantitative CLEIA antigen test was 0.903 (95% confidential interval 0.845-0.962, p < 0.001). The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5%. On the other hand, the diagnostic accuracy of the antigen test decreased among patients among patients with COVID-19 with threshold cycle (Ct-value)≥27, which shows the AUROC was 0.795 (95%CI 0.687-0.907, p < 0.001). CONCLUSION: While the automated quantitative CLEIA antigen test from saliva specimen could be one of the most useful diagnostic tests for the diagnosis of COVID-19 in general practice, clinicians should know the limitations of the antigen test.


Assuntos
COVID-19 , Saliva , Humanos , Técnicas Imunoenzimáticas , Japão , SARS-CoV-2 , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA