Phys Med ; 91: 80-86, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34739878

RESUMO

PURPOSE: The unique treatment delivery technique provided by magnetic resonance guided radiotherapy (MRgRT) can represent a significant drawback when system fail occurs. This retrospective study proposes and evaluates a pipeline to completely automate the workflow necessary to shift a MRgRT treatment to a traditional radiotherapy linac. MATERIAL AND METHODS: Patients undergoing treatment during the last MRgRT system failure were retrospectively included in this study. The core of the proposed pipeline was based on a tool able to mimic the original MR linac dose distribution. The so obtained dose distribution (AUTO) has been compared with the distribution obtained in the conventional radiotherapy linac (MAN). Plan comparison has been performed in terms of time required to obtain the final dose distribution, DVH parameters, dosimetric indices and visual analogue scales scoring by radiation oncologists. RESULTS: AUTO plans generation has been obtained within 10 min for all the considered cases. All AUTO plans were found to be within clinical tolerance, showing a mean target coverage variation of 1.7% with a maximum value of 4.3% and a minimum of 0.6% when compared with MAN plans. The highest OARs mean variation has been found for rectum V60 (6.7%). Dosimetric indices showed no relevant differences, with smaller gradient measure in favour of AUTO plans. Visual analogue scales scoring has confirmed comparable plan quality for AUTO plans. CONCLUSION: The proposed workflow allows a fast and accurate generation of automatic treatment plans. AUTO plans can be considered equivalent to MAN ones, with limited clinical impact in the worst-case scenario.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Imageamento por Ressonância Magnética , Dosagem Radioterapêutica , Estudos Retrospectivos
2.
Phys Med ; 85: 72-78, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33979726

RESUMO

PURPOSE: VMAT delivery technique is currently not applicable to Magnetic Resonance-guided radiotherapy (MRgRT) hybrid systems. Aim of this study is to evaluate an innovative VMAT-like (VML) delivery technique. MATERIAL AND METHODS: First, planning and dosimetric evaluation of the MRgRT VML treatment have been performed on 10 different disease sites and the results have been compared with the corresponding IMRT plans. Then, in the second phase, 10 of the most dosimetrically challenging locally advanced pancreas treatment plans have been retrospectively re-planned using the VML approach to explore the potentiality of this new delivery technique. Finally, VML robustness was evaluated and compared with the IMRT plans, considering a lateral positioning error of ± 5 mm. RESULTS: In phase one, all VML plans were within constraint for all OARs. When PTV coverage is considered, in the 50% of the cases VML PTV coverage is equal or higher than in IMRT plan. In the remaining 50%, the highest target under coverage difference in comparison with IMRT plan is -1.71%. The mean and maximum treatment time differences (VML-IMRT) is 0.2 min and 3.1 min respectively. In phase two, the treatment time variation (VML-IMRT), shows a mean, maximum and minimum variations of 1.3, 4.6 and -0.6 min respectively. All VML plans have a better target coverage if compared with IMRT plans, keeping in any case the OARs constraints within tolerance. VML doesn't increase plan robustness. CONCLUSION: VMAT-like treatment approach appeared to be an efficient planning solution and it was decided to clinically implement it in daily practice, especially in the frame of hypo fractionated treatments.


Assuntos
Radioterapia de Intensidade Modulada , Espectroscopia de Ressonância Magnética , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
3.
Phys Med ; 84: 149-158, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33895666

RESUMO

PURPOSE: Due to limited field size of Magnetic Resonance Linear Accelerators (MR-Linac), some treatments could require a dual-isocenter planning approach to achieve a complete target coverage and thus exploit the benefits of the online adaptation. This study evaluates the dosimetric accuracy of the dual-isocenter intensity modulated radiation therapy (IMRT) delivery technique for MR-Linac. MATERIAL AND METHODS: Dual-isocenter multi leaf collimator (MLC) and couch accuracy tests have been performed to evaluate the delivery accuracy of the system. A mono-isocenter plan delivered in clinical practice has then been retrospectively re-planned with dual-isocenter technique. The dual-isocenter plan has been re-calculated and delivered on a 3-dimensional (3D) ArcCHECK phantom and 2-dimensional (2D) films to assess its dosimetric accuracy in terms of gamma analysis. Clinical and planning target volume (CTV and PTV respectively) coverage robustness was then investigated after the introduction of ± 2 mm and ± 5 mm positioning errors by shifting the couch. RESULTS: MLC and couch accuracy tests confirmed the system accuracy in delivering a dual-isocenter irradiation. 2D/3D gamma analysis results occurred always to be above 95% if considered a gamma criteria 1%/2 mm and 1%/1 mm respectively for the 2D and 3D analysis. The mean variations for CTV D98% and PTV V95% were 0.2% and 1.1% respectively when positioning error was introduced separately in each direction, while the maximum observed variations were 0.9% (CTV) and 3.7% (PTV). CONCLUSION: The dosimetric accuracy of dual-isocenter irradiation has been verified for MR-Linac, achieving accurate and robust treatment strategy and improving dose conformality also in presence of targets whose extension exceeds the nominal maximum field size.


Assuntos
Neoplasias Abdominais , Radioterapia de Intensidade Modulada , Humanos , Campos Magnéticos , Espectroscopia de Ressonância Magnética , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
4.
Clin Transl Radiat Oncol ; 20: 27-29, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31768423

RESUMO

•The case report of a patient affected by locally advanced cervical MRgRT is described.•MRgRT appears to be feasible for cervical cancer and may improve treatment quality.•MRgRT insights are discussed focusing on adaptive response and toxicity monitoring.

5.
Clin Transl Radiat Oncol ; 19: 77-79, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31650042

RESUMO

INTRODUCTION: Colorectal cancer is a very common form of cancer worldwide, affecting an increasing number of young women. Standard treatment for locally advanced rectal cancer (LARC) can pose a threat to fertility in these patients. CASE PRESENTATION: We present the case of a young woman affected by LARC who expressed a desire for child-bearing. The treatment she was proposed, according to guidelines, was neoadjuvant chemo-radiotherapy (CRT) followed by delayed surgery, carrying with it a high risk for amenorrhea. Counselling was performed before the initiation of treatment, with the aim of preserving fertility by the proposal of GnRH agonist administration, ovarian transposition and ovarian tissue cryopreservation, which the patient accepted. Treatment was then successfully completed. The patient presented regular menstrual period from before the surgery. DISCUSSION: Ovarian tissue is very sensitive to radiations. Transposition of the organ can prevent ovarian insufficiency by placing it outside the radiation field, while ovarian tissue cryopreservation and orthotopic transplantation offers the possibility to restore fertility in the case of organ failure. We performed both of the techniques. GnRH analogs administration allowed to diminish the risk of ovarian cytotoxicity. Radiation treatment plan was optimized in order to minimize the dose to organs at risk (ovary and vagina in particular); position of the uterus, which is quite radiosensitive too, was monitored with daily cone-beam CT (CBCT). CONCLUSION: The strategy proposed seemed safe and effective, resulting in radical treatment and persistence of regular menstrual period. Further studies are needed.