Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Med Phys ; 50(11): 7203-7213, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37517077

RESUMO

BACKGROUND: Many studies have utilized optical camera systems with volumetric scintillators for quality assurances (QA) to estimate the proton beam range. However, previous analytically driven range estimation methods have the difficulty to derive the dose distributions from the scintillation images with quenching and optical effects. PURPOSE: In this study, a deep learning method utilized to QA was used to predict the beam range and spread-out Bragg peak (SOBP) for two-dimensional (2D) map conversion from the scintillation light distribution (LD) into the dose distribution in a water phantom. METHODS: The 2D residual U-net modeling for deep learning was used to predict the 2D water dose map from a 2D scintillation LD map. Monte Carlo simulations for dataset preparation were performed with varying monoenergetic proton beam energies, field sizes, and beam axis shifts. The LD was reconstructed using photons backpropagated from the aperture as a virtual lens. The SOBP samples were constructed based on monoenergetic dose distributions. The training set, including the validation set, consisted of 8659 image pairs of LD and water dose maps. After training, dose map prediction was performed using a 300 image pair test set generated under random conditions. The pairs of simulated and predicted dose maps were analyzed by Bragg peak fitting and gamma index maps to evaluate the model prediction. RESULT: The estimated beam range and SOBP width resolutions were 0.02 and 0.19 mm respectively for varying beam conditions, and the beam range and SOBP width deviations from the reference simulation result were less than 0.1 and 0.8 mm respectively. The simulated and predicted distributions showed good agreement in the gamma analysis, except for rare cases with failed gamma indices in the proximal and field-marginal regions. CONCLUSION: The deep learning conversion method using scintillation LDs in an optical camera system with a scintillator is feasible for estimating proton beam range and SOBP width with high accuracy.


Assuntos
Aprendizado Profundo , Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Simulação por Computador , Método de Monte Carlo , Água , Dosagem Radioterapêutica
2.
J Korean Phys Soc ; 81(11): 1013-1019, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966936

RESUMO

Cancer metastasis is the major cause of cancer mortality and accounts for about 90% of cancer death. Although radiation therapy has been considered to reduce the localized cancer burden, emerging evidence that radiation can potentially turn tumors into an in situ vaccine has raised significant interest in combining radiation with immunotherapy. However, the combination approach might be limited by the radiation-induced immunosuppression. Assessment of radiation effects on the immune system at the patient level is critical to maximize the systemic antitumor response of radiation. In this review, we summarize the developed solutions in three different categories for systemic radiation therapy: blood dose, radiation-induced lymphopenia, and tumor control. Furthermore, we address how they could be combined to optimize radiotherapy regimens and maximize their synergy with immunotherapy.

3.
PLoS One ; 17(8): e0272639, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36026490

RESUMO

The uncertainties of four-dimensional computed tomography (4DCT), also called as residual motion artefacts (RMA), induced from irregular respiratory patterns can degrade the quality of overall radiotherapy. This study aims to quantify and reduce those uncertainties. A comparative study on quantitative indicators for RMA was performed, and based on this, we proposed a new 4DCT sorting method that is applicable without disrupting the current clinical workflow. In addition to the default phase sorting strategy, both additional amplitude information from external surrogates and the quantitative metric for RMA, investigated in this study, were introduced. The comparison of quantitative indicators and the performance of the proposed sorting method were evaluated via 10 cases of breath-hold (BH) CT and 30 cases of 4DCT. It was confirmed that N-RMSD (normalised root-mean-square-deviation) was best matched to the visual standards of our institute's regime, manual sorting method, and could accurately represent RMA. The performance of the proposed method to reduce 4DCT uncertainties was improved by about 18.8% in the averaged value of N-RMSD compared to the default phase sorting method. To the best of our knowledge, this is the first study that evaluates RMA indicators using both BHCT and 4DCT with visual-criteria-based manual sorting and proposes an improved 4DCT sorting strategy based on them.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Artefatos , Suspensão da Respiração , Humanos , Movimento (Física) , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Respiração
4.
J Appl Clin Med Phys ; 22(1): 184-190, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33340391

RESUMO

PURPOSE: The purpose of this study was to develop automated planning for whole-brain radiation therapy (WBRT) using a U-net-based deep-learning model for predicting the multileaf collimator (MLC) shape bypassing the contouring processes. METHODS: A dataset of 55 cases, including 40 training sets, five validation sets, and 10 test sets, was used to predict the static MLC shape. The digitally reconstructed radiograph (DRR) reconstructed from planning CT images as an input layer and the MLC shape as an output layer are connected one-to-one via the U-net modeling. The Dice similarity coefficient (DSC) was used as the loss function in the training and ninefold cross-validation. Dose-volume-histogram (DVH) curves were constructed for assessing the automatic MLC shaping performance. Deep-learning (DL) and manually optimized (MO) approaches were compared based on the DVH curves and dose distributions. RESULTS: The ninefold cross-validation ensemble test results were consistent with DSC values of 94.6 ± 0.4 and 94.7 ± 0.9 in training and validation learnings, respectively. The dose coverages of 95% target volume were (98.0 ± 0.7)% and (98.3 ± 0.8)%, and the maximum doses for the lens as critical organ-at-risk were 2.9 Gy and 3.9 Gy for DL and MO, respectively. The DL technique shows the consistent results in terms of the DVH parameter except for MLC shaping prediction for dose saving of small organs such as lens. CONCLUSIONS: Comparable with the MO plan result, the WBRT plan quality obtained using the DL approach is clinically acceptable. Moreover, the DL approach enables WBRT auto-planning without the time-consuming manual MLC shaping and target contouring.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Irradiação Craniana , Estudos de Viabilidade , Humanos , Planejamento da Radioterapia Assistida por Computador
5.
Med Phys ; 48(5): e44-e64, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33260251

RESUMO

The era of real-time radiotherapy is upon us. Robotic and gimbaled linac tracking are clinically established technologies with the clinical realization of couch tracking in development. Multileaf collimators (MLCs) are a standard equipment for most cancer radiotherapy systems, and therefore MLC tracking is a potentially widely available technology. MLC tracking has been the subject of theoretical and experimental research for decades and was first implemented for patient treatments in 2013. The AAPM Task Group 264 Safe Clinical Implementation of MLC Tracking in Radiotherapy Report was charged to proactively provide the broader radiation oncology community with (a) clinical implementation guidelines including hardware, software, and clinical indications for use, (b) commissioning and quality assurance recommendations based on early user experience, as well as guidelines on Failure Mode and Effects Analysis, and (c) a discussion of potential future developments. The deliverables from this report include: an explanation of MLC tracking and its historical development; terms and definitions relevant to MLC tracking; the clinical benefit of, clinical experience with and clinical implementation guidelines for MLC tracking; quality assurance guidelines, including example quality assurance worksheets; a clinical decision pathway, future outlook and overall recommendations.


Assuntos
Radioterapia (Especialidade) , Robótica , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
PLoS One ; 15(7): e0236585, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32722692

RESUMO

The aim of this work is to build a framework that comprehends inverse planning procedure and plan optimization algorithm tailored to a novel directional beam intensity-modulated brachytherapy (IMBT) of cervical cancer using a rotatable, single-channel radiation shield. Inverse planning is required for finding optimal beam emitting direction, source dwell position and dwell time, which begin with creating a kernel matrix for each structure based on Monte-Carlo simulated dose distribution in the rotatable shield. For efficient beam delivery and less transit dose, the number of source dwell positions and angles needs to be minimized. It can be solved by L0-norm regularization for fewest possible dwell points, and by group sparsity constraint in L2,p-norm (0≤p<1) besides L0-norm for fewest active applicator rotating angles. The dose distributions from our proposed algorithms were compared to those of conventional tandem-based intracavitary brachytherapy (ICR) plans for six cervical cancer patients. The algorithmic performance was evaluated in delivery efficiency and plan quality relative to the unconstrained algorithm. The proposed framework yielded substantially enhanced plan quality over the conventional ICR plans. The L0-norm and (group sparsity+L0-norm) constrained algorithms reduced the number of source dwell points by 60 and 70% and saved 5 and 8 rotational angles on average (7 and 11 angles for highly modulated cases), relative to the unconstrained algorithm, respectively. Though both algorithms reduced the optimal source dwell positions and angles, the group sparsity constrained optimization with L0-norm was more effective than the L0-norm constraint only, mainly because of considering physical constraints of the new IMBT applicator. With much fewer dwell points compared to the unconstrained, the proposed algorithms led to statistically similar plan quality in dose volume histograms and iso-dose lines. It also demonstrated that the plan optimized by rotating the applicator resulted in much better plan quality than that of conventional applicator-based plans.


Assuntos
Braquiterapia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Rotação , Neoplasias do Colo do Útero/radioterapia , Algoritmos , Feminino , Humanos
7.
Sci Rep ; 10(1): 9693, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32546847

RESUMO

A novel wide-field electron arc technique with a scatterer is implemented for widespread Kaposi's sarcoma (KS) in the distal extremities. Monte Carlo beam modeling for electron arc beams was established to achieve <2% deviation from the measurements, and used for dose calculation. MC-based electron arc plan was performed using CT images of a foot and leg mimicking phantom and compared with in-vivo measurement data. We enrolled one patient with recurrent KS on the lower extremities who had been treated with photon radiation therapy. The 4- and 6-MeV electron arc plans were created, and then compared to two photon plans: two opposite photon beam and volumetric modulated arc with bolus. Compared to the two photon techniques, the electron arc plans resulted in superior dose saving to normal organs beneath the skin region, although it shows inferior coverage and homogeneity for PTV. The electron arc treatment technique with scatterer was successfully implemented for the treatment of widespread KS in the distal extremities with lower radiation exposure to the normal organs beyond the skin lesions, which could be a treatment option for recurrent skin cancer in the extremities.


Assuntos
Terapia com Prótons/métodos , Sarcoma de Kaposi/radioterapia , Neoplasias Cutâneas/radioterapia , , Mãos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
Sci Rep ; 10(1): 6204, 2020 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-32277135

RESUMO

Segmentation of normal organs is a critical and time-consuming process in radiotherapy. Auto-segmentation of abdominal organs has been made possible by the advent of the convolutional neural network. We utilized the U-Net, a 3D-patch-based convolutional neural network, and added graph-cut algorithm-based post-processing. The inputs were 3D-patch-based CT images consisting of 64 × 64 × 64 voxels designed to produce 3D multi-label semantic images representing the liver, stomach, duodenum, and right/left kidneys. The datasets for training, validating, and testing consisted of 80, 20, and 20 CT simulation scans, respectively. For accuracy assessment, the predicted structures were compared with those produced from the atlas-based method and inter-observer segmentation using the Dice similarity coefficient, Hausdorff distance, and mean surface distance. The efficiency was quantified by measuring the time elapsed for segmentation with or without automation using the U-Net. The U-Net-based auto-segmentation outperformed the atlas-based auto-segmentation in all abdominal structures, and showed comparable results to the inter-observer segmentations especially for liver and kidney. The average segmentation time without automation was 22.6 minutes, which was reduced to 7.1 minutes with automation using the U-Net. Our proposed auto-segmentation framework using the 3D-patch-based U-Net for abdominal multi-organs demonstrated potential clinical usefulness in terms of accuracy and time-efficiency.


Assuntos
Abdome/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Duodeno/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estômago/diagnóstico por imagem
9.
J Gastroenterol Hepatol ; 35(11): 1953-1959, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32052884

RESUMO

BACKGROUND AND AIM: The purpose of this study was to investigate the long-term oncologic outcomes after stereotactic body radiation therapy (SBRT) for small hepatocellular carcinoma (HCC). METHODS: A total of 290 patients with HCC were registered between March 2007 and July 2013. A dose of 10-15 Gy per fraction was given over three to four consecutive days, resulting in a total dose of 30-60 Gy. Overall and recurrence-free survivals were estimated from the date of the start of SBRT to the date of death, the last follow-up examination, or to the date of tumor recurrence. RESULTS: The median follow-up period of all patients was 38.2 months, and the median tumor size was 1.7 cm. Overall survival (OS) rate at 5 years was 44.9%. Multivariate analyses revealed that age, Child-Pugh class, tumor size, and albumin levels were significant factors for OS. The 5-year local control rate was 91.3%. In multivariate analysis, tumor size and albumin were significantly associated with local tumor control. However, there was a negative correlation between total dose and tumor size in Pearson's correlation analysis (r = -0.111, P = 0.046). CONCLUSIONS: Stereotactic body radiation therapy was an excellent ablative treatment option for patients with small HCC. Tumor size was a significant factor for local tumor control after SBRT, although the total dose was negatively correlated with tumor size. Considering the low OS rates and the high local tumor control rates, the combined SBRT and systemic therapies may be beneficial for improving survival outcomes.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiocirurgia/efeitos adversos , Dosagem Radioterapêutica , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
10.
Phys Med Biol ; 65(5): 055001, 2020 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-31968326

RESUMO

The purpose of this study is to propose a reconstruction method of a target and its neighborhood, representative of the moment of radiotherapy delivery, based on differences in its transit images between the time of planning computed tomography (pCT) and the time of treatment beam delivery. To validate the method, a lung phantom with a target object was constructed, and CT-scanned before and after making a shift of the target. The latter scan was intended to simulate a potential organ movement at the time of treatment, and to serve as ground-truth images. Treatment planning using arc-beam delivery was done on the first pCT images. The planned beams were irradiated to the phantom after the shift, while cine transit images were acquired. Cine transit images were also calculated through the pCT images before the shift. From the ratio of the measured and calculated transit images, the amount of image changes due to the organ movement between the time of pCT and that of treatment was three-dimensionally reconstructed. By adding the reconstructed images to the pCT images before the shift, the CT images of the phantom at the time of the beam delivery were generated and compared with the ground truth images. The phantom after the shift was also scanned by on-board cone-beam computer tomography (CBCT) and reconstructed from the measured transit images (MVCT) for comparison. The proposed method reconstructed images that are very close to the ground-truth images in the volume and HU values of the target and the dose-volume coverage of the target and lung. Similar agreement was not found in the CBCT and MVCT images. The method may be used for 4D target image reconstruction, and, combined with the reconstructed image of un-irradiated areas, may offer clinically useful images of the entire region of interest.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/radioterapia , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Movimento , Imagens de Fantasmas
11.
Sci Rep ; 9(1): 15671, 2019 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-31666647

RESUMO

A deep-neural-network (DNN) was successfully used to predict clinically-acceptable dose distributions from organ contours for intensity-modulated radiotherapy (IMRT). To provide the next step in the DNN-based plan automation, we propose a DNN that directly generates beam fluence maps from the organ contours and volumetric dose distributions, without inverse planning. We collected 240 prostate IMRT plans and used to train a DNN using organ contours and dose distributions. After training was done, we made 45 synthetic plans (SPs) using the generated fluence-maps and compared them with clinical plans (CP) using various plan quality metrics including homogeneity and conformity indices for the target and dose constraints for organs at risk, including rectum, bladder, and bowel. The network was able to generate fluence maps with small errors. The qualities of the SPs were comparable to the corresponding CPs. The homogeneity index of the target was slightly worse in the SPs, but there was no difference in conformity index of the target, V60Gy of rectum, the V60Gy of bladder and the V45Gy of bowel. The time taken for generating fluence maps and qualities of SPs demonstrated the proposed method will improve efficiency of the treatment planning and help maintain the quality of plans.


Assuntos
Próstata/efeitos da radiação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Masculino , Redes Neurais de Computação , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
12.
J Appl Clin Med Phys ; 20(2): 107-113, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30667581

RESUMO

PURPOSE: To compare the dosimetric impact and treatment delivery efficacy of phase-gated volumetric modulated arc therapy (VMAT) vs amplitude-gated VMAT for stereotactic body radiation therapy (SBRT) for lung cancer by using realistic three-dimensional-printed phantoms. METHODS: Four patient-specific moving lung phantoms that closely simulate the heterogeneity of lung tissue and breathing patterns were fabricated with four planning computed tomography (CT) images for lung SBRT cases. The phantoms were designed to be bisected for the measurement of two-dimensional dose distributions by using EBT3 dosimetry film. The dosimetric accuracy of treatment under respiratory motion was analyzed with the gamma index (2%/1 mm) between the plan dose and film dose measured under phase- and amplitude-gated VMAT. For the validation of the direct usage of the real-time position management (RPM) data for respiratory motion, the relationship between the RPM signal and the diaphragm position was measured by four-dimensional CT. By using data recorded during the beam delivery of both phase- and amplitude-gated VMAT, the total time intervals were compared for each treatment mode. RESULTS: Film dosimetry showed a 5.2 ± 4.2% difference of gamma passing rate (2%/1 mm) on average between the phase- vs amplitude-gated VMAT [77.7% (72.7%-85.9%) for the phase mode and 82.9% (81.4%-86.2%) for the amplitude mode]. For delivery efficiency, frequent interruptions were observed during the phase-gated VMAT, which stopped the beam delivery and required a certain amount of time before resuming the beam. This abnormality in phase-gated VMAT caused a prolonged treatment delivery time of 366 s compared with 183 s for amplitude-gated VMAT. CONCLUSIONS: Considering the dosimetric accuracy and delivery efficacy between the gating methods, amplitude mode is superior to phase mode for gated VMAT treatment.


Assuntos
Neoplasias Pulmonares/cirurgia , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Respiração
13.
J Appl Clin Med Phys ; 20(1): 237-249, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30597725

RESUMO

PURPOSE: As computed tomography (CT) imaging is the most commonly used modality for treatment planning in radiation therapy, metal artifacts in the planning CT images may complicate the target delineation and reduce the dose calculation accuracy. Although current CT scanners do provide certain correction steps, it is a common understanding that there is not a universal solution yet to the metal artifact reduction (MAR) in general. Particularly noting the importance of MAR for radiation treatment planning, we propose a novel MAR method in this work that recruits an additional tilted CT scan and synthesizes nearly metal-artifact-free CT images. METHODS: The proposed method is based on the facts that the most pronounced metal artifacts in CT images show up along the x-ray beam direction traversing multiple metallic objects and that a tilted CT scan can provide complementary information free of such metal artifacts in the earlier scan. Although the tilted CT scan would contain its own metal artifacts in the images, the artifacts may manifest in a different fashion leaving a chance to concatenate the two CT images with the metal artifacts much suppressed. We developed an image processing technique that uses the structural similarity (SSIM) for suppressing the metal artifacts. On top of the additional scan, we proposed to use an existing MAR method for each scan if necessary to further suppress the metal artifacts. RESULTS: The proposed method was validated by a simulation study using the pelvic region of an XCAT numerical phantom and also by an experimental study using the head part of the Rando phantom. The proposed method was found to effectively reduce the metal artifacts. Quantitative analyses revealed that the proposed method reduced the mean absolute percentages of the error by up to 86% and 89% in the simulation and experimental studies, respectively. CONCLUSIONS: It was confirmed that the proposed method, using complementary information acquired from an additional tilted CT scan, can provide nearly metal-artifact-free images for the treatment planning.


Assuntos
Metais , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/normas , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
14.
PLoS One ; 13(12): e0208685, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30586367

RESUMO

PURPOSE: This study aimed to evaluate the dosimetric accuracy of respiratory gated volumetric modulated arc therapy (VMAT) for lung stereotactic body radiation therapy (SBRT) under simulation conditions similar to the actual clinical situation using patient-specific lung phantoms and realistic target movements. METHODS: Six heterogeneous lung phantoms were fabricated using a 3D-printer (3DISON, ROKIT, Seoul, Korea) to be dosimetrically equivalent to actual target regions of lung SBRT cases treated via gated VMAT. They were designed to move realistically via a motion device (QUASAR, Modus Medical Devices, Canada). Using the lung phantoms and a homogeneous phantom (model 500-3315, Modus Medical Devices), film dosimetry was performed with and without respiratory gating for VMAT delivery (TrueBeam STx; Varian Medical Systems, Palo Alto, CA, USA). The measured results were analyzed with the gamma passing rates (GPRs) of 2%/1 mm criteria, by comparing with the calculated dose via the AXB and AAA algorithms of the Eclipse Treatment Planning System (version 10.0.28; Varian Medical Systems). RESULTS: GPRs were greater than the acceptance criteria 80% for all film measurements with the stationary and homogeneous phantoms in conventional QAs. Regardless of the heterogeneity of phantoms, there were no significant differences (p > 0.05) in GPRs obtained with and without target motions; the statistical significance (p = 0.031) was presented between both algorithms under the utilization of heterogeneous phantoms. CONCLUSIONS: Dosimetric verification with heterogeneous patient-specific lung phantoms could be successfully implemented as the evaluation method for gated VMAT delivery. In addition, it could be dosimetrically confirmed that the AXB algorithm improved the dose calculation accuracy under patient-specific simulations using 3D printed lung phantoms.


Assuntos
Pulmão , Imagens de Fantasmas , Impressão Tridimensional , Radiocirurgia/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Respiração , Algoritmos , Desenho de Equipamento , Tomografia Computadorizada Quadridimensional , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Pulmão/efeitos da radiação , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Modelos Anatômicos , Movimento , Modelagem Computacional Específica para o Paciente , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Technol Cancer Res Treat ; 17: 1533033818810391, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30384804

RESUMO

PURPOSE: To develop an one-click option on treatment planning system that enables for the automated breast FIF planning by combining the Eclipse Scripting application programming interfaces and user-executed programming in Windows. METHODS: Scripting application programming interfaces were designed to promote automation in clinical workflow associated with radiation oncology. However, scripting cannot provide all functions that users want to perform. Thus, a new framework proposes to integrate the benefits of the scripting application and user-executed programming for the automated field-in-field technique. We adopted the Eclipse Scripting applications, which provide an interface between treatment planning system server and client and enable for running the executed program to create dose clouds and adjust the planning parameters such as multi-leaf collimator placements and monitor unit values. Importantly, all tasks are designed to perform with one-click option on treatment planning system, including the automated pushback of the proposed plan to the treatment planning system. RESULTS: The plans produced from the proposed framework were validated against the manual field-in-field plans with 40 retrospective breast patient cases in planning efficiency and plan quality. The elapsed time for running the framework was less than 1 minute, which significantly reduced the manual multi-leaf collimator/monitor unit adjustment time. It decreased the total planning time by more than 50%, relative to the manual field-in-field planning. In dosimetric aspects, the mean and maximum dose of the heart, lung, and whole breast did not exceed 1% deviation from the manual plans in most patient cases, while maintaining the target dose coverage and homogeneity index inside the target volume. From numerical analysis, the automated plans were demonstrated to be sufficiently close to the manual plans. CONCLUSION: The combination of scripting applications and user-executed programming for automated breast field-in-field planning accomplished a significant enhancement in planning efficiency without degrading the plan quality, relative to the manual field-in-field procedure.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Automação/métodos , Mama/patologia , Neoplasias da Mama/patologia , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
16.
Sci Rep ; 8(1): 16224, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30385839

RESUMO

This study aimed to evaluate hepatic toxicity after repeated stereotactic body radiation therapy (SBRT) for recurrent hepatocellular carcinoma (HCC) using deformable image registration (DIR). Between January 2007 and December 2015, 85 patients who underwent two sessions of SBRT for HCC treatment were retrospectively analyzed. A DIR technique was used to calculate the cumulative dose of the first and second SBRT to the normal liver by matching two computed tomography simulation images. The Dice similarity coefficient (DSC) index was calculated to evaluate DIR accuracy. Before the first and second SBRT, 6 (7.1%) and 12 (14.1%) patients were Child-Pugh class B, respectively. Median tumor size was 1.7 cm before both SBRT treatments. Mean DSC index value was 0.93, being >0.9 in 79 (92.9%) registrations. Median cumulative mean liver dose (MLD) was 9.3 Gy (interquartile range, 7.6-11.7). Radiation-induced liver disease developed in three patients, and two of them, with Child-Pugh class B, experienced irreversible liver function deterioration following the second SBRT. The DIR method provided reliable information regarding cumulative doses to the liver. In patients with Child-Pugh class A liver function, repeated SBRT for small recurrent HCC could be safely performed with acceptable hepatic toxicity.


Assuntos
Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/radioterapia , Radiocirurgia/efeitos adversos , Radioterapia Guiada por Imagem , Idoso , Carcinoma Hepatocelular/diagnóstico , Feminino , Humanos , Fígado/patologia , Fígado/efeitos da radiação , Neoplasias Hepáticas/diagnóstico , Masculino , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos , Retratamento , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
17.
J Korean Neurosurg Soc ; 61(6): 753-760, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30396248

RESUMO

OBJECTIVE: We investigated the effect of optimization in dose-limiting shell method on the dosimetric quality of CyberKnife (CK) plans in treating brain metastases (BMs). METHODS: We selected 19 BMs previously treated using CK between 2014 and 2015. The original CK plans (CKoriginal) had been produced using 1 to 3 dose-limiting shells : one at the prescription isodose level (PIDL) for dose conformity and the others at lowisodose levels (10-30% of prescription dose) for dose spillage. In each case, a modified CK plan (CKmodified) was generated using 5 dose-limiting shells : one at the PIDL, another at intermediate isodose level (50% of prescription dose) for steeper dose fall-off, and the others at low-isodose levels, with an optimized shell-dilation size based on our experience. A Gamma Knife (GK) plan was also produced using the original contour set. Thus, three data sets of dosimetric parameters were generated and compared. RESULTS: There were no differences in the conformity indices among the CKoriginal, CKmodified, and GK plans (mean 1.22, 1.18, and 1.24, respectively; p=0.079) and tumor coverage (mean 99.5%, 99.5%, and 99.4%, respectively; p=0.177), whereas the CKmodified plans produced significantly smaller normal tissue volumes receiving 50% of prescription dose than those produced by the CKoriginal plans (p<0.001), with no statistical differences in those volumes compared with GK plans (p=0.345). CONCLUSION: These results indicate that significantly steeper dose fall-off is able to be achieved in the CK system by optimizing the shell function while maintaining high conformity of dose to tumor.

18.
PLoS One ; 13(9): e0202765, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30192793

RESUMO

PURPOSE: To develop a 4D dose reconstruction method and to evaluate the delivered dose in respiratory-gated volumetric modulated arc therapy (VMAT). MATERIALS AND METHODS: A total 112 treatment sessions of gated VMAT for 30 stereotactic body radiotherapy (SBRT) patients (10 lung, 10 liver, and 10 pancreas) were evaluated. For respiratory-gated SBRT, 4DCT was acquired, and the CT data at the end-exhale phase was used for a VMAT plan. The delivered dose was reconstructed using a patient's respiratory motion and machine motion acquired during the beam delivery. The machine motion was obtained from the treatment log file, while the target position was estimated from an external respiratory marker position. The target position was divided into 1-mm position bins, and sub-beams with beam isocenters corresponding to each position bin were created in a motion mimicking plan, reflecting motion data including MLC leaf positions and gantry angle and target position data during beam treatment. The reconstructed 4D dose was compared with the dose of the original plan using these dosimetric parameters; the maximum dose (Dmax) and mean dose (Dmean) of gross target volume (GTV) or organs at risk (spinal cord, esophagus, heart, duodenum, kidney, spinal cord, and stomach). The minimum dose (Dmin) to GTV was also calculated to verify cold spots in tumors. RESULTS: There was no significant difference of dose parameters regard to the GTV in all tumors. For the liver cases, there were significant differences in the Dmax of duodenum (-4.2 ± 1.4%), stomach (-3.5 ± 4.2%), left kidney (-4.1 ± 2.8%), and right kidney (-3.2 ± 1.3%), and in the Dmean of duodenum (-3.8 ± 1.4%), stomach (-3.9 ± 2.2%), left kidney (-3.1 ± 2.8%), and right kidney (-4.1 ± 2.6%). For the pancreas cases, there were significant differences in the Dmax of stomach (2.1 ± 3.0%), and in the Dmean of liver (1.5 ± 0.6%), duodenum (-1.0 ± 1.4%), stomach (2.1 ± 1.6%), and right kidney (-1.3 ± 0.9%). The average gamma pass rates were 97.6 ± 4.8% for lung cases, 99.6 ± 0.5% for liver cases, and 99.5 ± 0.5% for pancreas cases. Most cases showed insignificant dose variation, with gamma pass rates higher than 98%, except for two lung cases with gamma pass rates of 86.9% and 90.6%. The low gamma pass rates showed larger global motion ranges resulting from the baseline shift during beam delivery. CONCLUSION: The actual delivered dose in thoracic and abdominal VMAT under breathing motion was verified by 4D dose reconstruction using typical treatment equipment and software. The proposed method provides a verification method for the actual delivered dose and could be a dosimetric verification QA tool for radiation treatment under various respiratory management techniques.


Assuntos
Tomografia Computadorizada Quadridimensional , Doses de Radiação , Radioterapia de Intensidade Modulada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
20.
Int J Radiat Oncol Biol Phys ; 102(4): 867-874, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29934276

RESUMO

PURPOSE: Stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC) has emerged as an alternative treatment option when curative treatment modalities cannot be applied. Although excellent local tumor control has been achieved with SBRT, the targeting accuracy in real-life practice remains poorly understood. We proposed an in vivo assessment of targeting accuracy using hepatic parenchymal changes observed on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) images and applied this method to investigate the "real-life" targeting accuracy of image-guided SBRT. METHODS AND MATERIALS: We selected 29 patients with available follow-up MR images acquired 2 to 4 months after completion of SBRT. All patients were administered 45 Gy in 3 fractions. The treated HCC and the region of hepatic parenchymal changes in the hepatobiliary phase of MR images were delineated. We evaluated the discrepancies between the center of the HCC and that of the parenchymal change area (intercenter discrepancy [ICD]). We also analyzed the difference in ICDs between those who underwent SBRT with intrahepatic marker guidance and those with diaphragm guidance. RESULTS: The median ICD in the 3-dimensional direction was 6.81 mm (interquartile range [IQR], 4.27-9.61 mm). Those for the craniocaudal, left-right, and anteroposterior components were 2.70 mm (IQR, 1.83-4.06 mm), 1.63 mm (IQR, 0.76-3.49), and 4.12 mm (IQR, 1.20-6.96 mm), respectively. The median ICD for patients who underwent treatment with intrahepatic marker guidance and those with diaphragm guidance was 7.53 mm (IQR, 6.63-10.86 mm) and 5.60 mm (IQR, 4.28-8.18 mm), respectively. There was no significant difference in ICD between those who underwent treatment with intrahepatic marker guidance and those with diaphragm guidance (P = .296). CONCLUSIONS: The hepatic parenchymal changes observed on Gd-EOB-DTPA-enhanced MR images can be used to assess the targeting accuracy after SBRT for HCC.


Assuntos
Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA