Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 292
Filtrar
1.
Radiology ; 301(3): 625-634, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34519576

RESUMO

Background Nonalcoholic fatty liver disease (NAFLD) is common in the general population but identifying patients with high-risk nonalcoholic steatohepatitis (NASH) who are candidates for pharmacologic therapy remains a challenge. Purpose To develop a score to identify patients with high-risk NASH, defined as NASH with an NAFLD activity score (NAS) of 4 or greater and clinically significant fibrosis (stage 2 [F2] or higher). Materials and Methods This was a cross-sectional secondary analysis of data prospectively collected between April 2017 and March 2019 for a group of patients with NAFLD in Japan (Japan NAFLD, the derivation data set) with contemporaneous two-dimensional shear-wave elastography and biopsy-proven NAFLD (age range, 20-89 years). Three US markers (liver stiffness [LS, measured in kilopascals], attenuation coefficient [AC, measured in decibels per centimeter per megahertz], and dispersion slope [DS, measured in meters per second per kilohertz]) were determined, together with aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels and the AST-to-ALT ratio. The best-fit multivariate logistic regression model for identifying patients with high-risk NASH was determined. Diagnostic performance was assessed by using the area under the receiver operating characteristic curve (AUC). The findings were validated in an independent data set (Korea NAFLD; age range, 20-78 years). Results The Japan NAFLD data set included 111 patients (mean age, 53 years ± 18 [standard deviation]; 57 men), 84 (76%) with NASH. The Korea NAFLD data set included 102 patients (mean age, 48 years ± 18; 43 men), 55 (36%) with NASH. The most predictive model (LAD NASH score) combined LS, AC, and DS. Performance was satisfactory in both the derivation sample (AUC, 0.86; 95% CI: 0.79, 0.93) and the validation sample (AUC, 0.88; 95% CI: 0.80, 0.95). The LAD NASH score showed a positive predictive value of 86.5% and a negative predictive value of 87.5% for high-risk NASH in the derivation sample. Conclusion A score combining three US markers may be useful for noninvasive identification of patients with high-risk nonalcoholic steatohepatitis for inclusion in clinical trials and pharmacologic therapy. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lockhart in this issue.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Japão , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , República da Coreia , Adulto Jovem
2.
Br J Radiol ; 94(1121): 20201242, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33560888

RESUMO

Currently, ultrasound (US) is a valuable imaging tool for the initial assessment and evaluation of the female genital organs, uterus, and adnexa. However, it is easy to overlook the uterine cervix while conducting a pelvic US. Uterine cervical lesions may range from benign to malignant in nature. Therefore, meticulous examination with US may play a key role in assessing uterine cervical lesions. Although there is substantial overlap in the US findings across various uterine cervical lesions, some US features, in tandem with clinical characteristics, may suggest a specific diagnosis. Familiarity with the clinical settings and US characteristics of different uterine cervical lesions can support prompt and accurate diagnosis of suspicious lesions. This review article aims to describe the features of US and possible values for distinction of these lesions in the uterine cervix.


Assuntos
Colo do Útero/diagnóstico por imagem , Ultrassonografia , Doenças do Colo do Útero/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Aborto Espontâneo/diagnóstico por imagem , Adolescente , Adulto , Carcinoma/diagnóstico por imagem , Colo do Útero/anormalidades , Colo do Útero/anatomia & histologia , Criança , Endometriose/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Pólipos/diagnóstico por imagem , Gravidez , Gravidez Ectópica/diagnóstico por imagem , Ultrassonografia/métodos , Artéria Uterina/diagnóstico por imagem , Incompetência do Colo do Útero/diagnóstico por imagem
3.
Eur Radiol ; 31(8): 5802-5811, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33459859

RESUMO

OBJECTIVES: Both transient elastography (TE) and 2D shear wave elastography (SWE) are accurate methods to evaluate liver fibrosis. We aimed to evaluate the diagnostic performance of 2D-SWE in predicting post-hepatectomy complication and to compare it with TE. METHODS: We prospectively enrolled 125 patients with liver tumors. Liver stiffness (LS) (kilopascal [kPa]) was measured using both TE and 2D-SWE before surgery. All post-operative complication was evaluated using the comprehensive complication index (CCI), and CCI ≥ 26.2 was defined as severe complication. Logistic regression analysis was performed to identify predictive factors for severe complication. Receiver operating characteristic analysis was used to evaluate the diagnostic performance of TE/2D-SWE in detecting liver fibrosis and severe complication. RESULTS: Severe complication developed in 18 patients. The median LS in patients with severe complication was significantly higher for both 2D-SWE (11.4 kPa vs. 7.0 kPa, p < 0.001) and TE (8.9 kPa vs. 6.2 kPa, p = 0.009). LS obtained from 2D-SWE was a significant factor correlated with severe complication (odds ratio: 1.27 per kPa [1.10-1.46], p = 0.001). The diagnostic performance of 2D-SWE was significantly higher than that of TE in detecting both ≥F3 (p = 0.024) and F4 (p = 0.048). The area under the curve of 2D-SWE to predict severe complication was 0.854, significantly higher than 0.692 of TE (p = 0.004). The optimal cut-off LS from 2D-SWE to predict severe complication was 8.6 kPa, with sensitivity of 88.9% (16/18) and specificity of 73.8% (79/107). CONCLUSION: LS obtained from 2D-SWE was a significant predictive factor for severe complication, and 2D-SWE showed significantly a better diagnostic performance than TE in detecting liver fibrosis and severe complication. KEY POINTS: • The diagnostic performance of 2D-SWE was significantly higher than that of TE in detecting both ≥ F3 (AUC: 0.853 vs. 0.779, p = 0.024) and F4 (AUC: 0.929 vs. 0.872, p = 0.048). • Liver stiffness value obtained from 2D-SWE was a significant factor correlated with the development of severe complication defined as CCI ≥ 26.2 after hepatic resection for liver tumors (odds ratio: 1.27 per kPa [1.10-1.46], p = 0.001). • 2D-SWE provided significantly a better diagnostic performance in predicting severe complication after hepatic resection than TE (AUC for 2D-SWE: 0.853 vs. AUC for TE: 0.692, p = 0.004).


Assuntos
Técnicas de Imagem por Elasticidade , Hepatectomia/efeitos adversos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Prospectivos
4.
Clin Gastroenterol Hepatol ; 19(4): 797-805.e7, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32450363

RESUMO

BACKGROUND & AIMS: We evaluated the accuracy of a multiparametric approach using attenuation imaging and 2-dimensional shear wave elastography (2D-SWE) for the detection of steatosis and fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). METHODS: We studied 102 patients with increased levels of liver enzymes or suspicion of NAFLD, examined by attenuation imaging and 2D-SWE, immediately before biopsy collection and analysis (reference standard), from January 2018 to July 2019. We collected data on the attenuation coefficient (dB/cm/MHz) from attenuation imaging, liver stiffness measurements, and shear wave dispersion slope (SWDS, [m/s]/kHz) from 2D-SWE. Multivariate linear regression analysis was performed to identify factors associated with each parameter. Diagnostic performance was determined from area under the receiver operating curve (AUROC) values. RESULTS: The attenuation coefficient was associated with steatosis grade (P < .01) and identified patients with steatosis grades S1 or higher, S2 or higher, and S3 or higher, with AUROC values of 0.93, 0.88, and 0.83, respectively. Liver stiffness associated with fibrosis stage (P < .01) and lobular inflammatory activity was the only factor associated with SWDS (P < .01). SWDS detected inflammation grades I1 or higher, I2 or higher, and I3 or higher with AUROC values of 0.89, 0.85, and 0.78, respectively. We developed a risk scoring system to detect steatohepatitis based on the attenuation coefficient (score of 1 for 0.64 < attenuation coefficient ≤ 0.70; score of 2 for 0.70 < attenuation coefficient ≤ 0.73; and score of 3 for attenuation coefficient >0.73) and SWDS (score of 2 for 10.5 [m/s]/kHz < SWDS ≤ 11.7 [m/s]/kHz; and score of 3 for SWDS >11.7 [m/s]/kHz), using an unweighted sum of each score. Based on histopathology analysis, 55 patients had steatohepatitis. Risk scores correlated with NAFLD activity score (rho = 0.73; P < .01). Our scoring system identified patients with steatohepatitis with an AUROC of 0.93-this value was significantly higher than that of other parameters (P < .05), except SWDS (AUROC, 0.89; P = .18). CONCLUSIONS: In the evaluation of patients with suspected NAFLD, the attenuation coefficient can identify patients with steatosis and liver stiffness can detect fibrosis accurately. SWDS was associated significantly with lobular inflammation. We developed a risk scoring system based on the attenuation coefficient and SWDS that might be used to detect steatohepatitis.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Área Sob a Curva , Biópsia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia
5.
Ultraschall Med ; 42(6): 599-606, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32323278

RESUMO

PURPOSE: To assess the diagnostic performance of the normalized local variance (NLV) ultrasound technique in the detection of the fatty liver using histopathology as a reference standard. MATERIALS AND METHODS: We prospectively enrolled 194 consecutive patients with clinical suspicion of diffuse liver disease or history of liver transplantation. Conventional grayscale ultrasound and NLV examinations were performed and immediately followed by liver biopsies. The degrees of fatty liver, necroinflammatory activity, and fibrosis stage were evaluated by histopathological assessment. The diagnostic performance of the NLV values in detecting each grade of fatty liver was determined using receiver operating characteristics analyses, and multivariate linear regression analyses were performed to identify variables significantly associated with the NLV values. RESULTS: The number of patients in each degree of fatty liver and hepatic fibrosis was 118/37/26/13 and 81/68/24/6/14 for none/mild/moderate/severe steatosis and F0 / F1/F2 / F3/F4 fibrosis on histopathological examinations, respectively. The area under the receiver operating characteristics curve and optimal cut-off NLV value for detecting fatty liver of varying degrees were 0.911 and 1.095 for ≥ S1, 0.974 and 1.055 for ≥ S2, and 0.954 and 1.025 for ≥ S3, respectively. Multivariate analyses revealed that not fibrosis or inflammation but rather the degree of steatosis was associated with the NLV value. CONCLUSION: The NLV value demonstrated excellent diagnostic performance for detecting varying degrees of fatty liver, and the degree of steatosis on histopathological examinations was the only significant factor affecting the NLV value.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso , Área Sob a Curva , Biópsia , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Estudos Prospectivos , Curva ROC
6.
Korean J Radiol ; 21(12): 1317-1325, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32729274

RESUMO

OBJECTIVE: The aim of this study was to prospectively evaluate whether liver stiffness (LS) assessments, obtained by two-dimensional (2D)-shear wave elastography (SWE) with a propagation map, can evaluate liver fibrosis stage using histopathology as the reference standard. MATERIALS AND METHODS: We prospectively enrolled 123 patients who had undergone percutaneous liver biopsy from two tertiary referral hospitals. All patients underwent 2D-SWE examination prior to biopsy, and LS values (kilopascal [kPa]) were obtained. On histopathologic examination, fibrosis stage (F0-F4) and necroinflammatory activity grade (A0-A4) were assessed. Multivariate linear regression analysis was performed to determine the significant factors affecting the LS value. The diagnostic performance of the LS value for staging fibrosis was assessed using receiver operating characteristic (ROC) analysis, and the optimal cut-off value was determined by the Youden index. RESULTS: Reliable measurements of LS values were obtained in 114 patients (92.7%, 114/123). LS values obtained from 2D-SWE with the propagation map positively correlated with the progression of liver fibrosis reported from histopathology (p < 0.001). According to the multivariate linear regression analysis, fibrosis stage was the only factor significantly associated with LS (p < 0.001). The area under the ROC curve of LS from 2D-SWE with the propagation map was 0.773, 0.865, 0.946, and 0.950 for detecting F ≥ 1, F ≥ 2, F ≥ 3, and F = 4, respectively. The optimal cut-off LS values were 5.4, 7.8, 9.4, and 12.2 kPa for F ≥ 1, F ≥ 2, F ≥ 3, and F = 4, respectively. The corresponding sensitivity and specificity of the LS value for detecting cirrhosis were 90.9% and 88.4%, respectively. CONCLUSION: The LS value obtained from 2D-SWE with a propagation map provides excellent diagnostic performance in evaluating liver fibrosis stage, determined by histopathology.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Técnicas de Imagem por Elasticidade/normas , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Padrões de Referência , Índice de Gravidade de Doença , Centros de Atenção Terciária , Ultrassonografia/normas , Adulto Jovem
7.
Ultrasound Med Biol ; 46(10): 2579-2604, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32713788

RESUMO

The present, updated document describes the fourth iteration of recommendations for the hepatic use of contrast-enhanced ultrasound, first initiated in 2004 by the European Federation of Societies for Ultrasound in Medicine and Biology. The previous updated editions of the guidelines reflected changes in the available contrast agents and updated the guidelines not only for hepatic but also for non-hepatic applications. The 2012 guideline requires updating as, previously, the differences in the contrast agents were not precisely described and the differences in contrast phases as well as handling were not clearly indicated. In addition, more evidence has been published for all contrast agents. The update also reflects the most recent developments in contrast agents, including U.S. Food and Drug Administration approval and the extensive Asian experience, to produce a truly international perspective. These guidelines and recommendations provide general advice on the use of ultrasound contrast agents (UCAs) and are intended to create standard protocols for the use and administration of UCAs in liver applications on an international basis to improve the management of patients.


Assuntos
Meios de Contraste , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Ultrassonografia/normas , Humanos , Hepatopatias/terapia , Neoplasias Hepáticas/terapia , Ultrassonografia/métodos , Ultrassonografia de Intervenção
8.
Ultrasound Q ; 36(1): 84-86, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29727346

RESUMO

Extramammary Paget disease (EMPD) is a rare intraepithelial malignancy originating in areas rich in apocrine glands, such as the vulva, perineum, perianal area, scrotum, and penis. A few reports of EMPD involving the scrotum have been described in the literature. However, only few reports have described imaging features observed in patients presenting with EMPD. We report EMPD in a patient showing scrotal involvement, focusing on imaging features, particularly those determined ultrasonographically.


Assuntos
Neoplasias dos Genitais Masculinos/diagnóstico por imagem , Doença de Paget Extramamária/diagnóstico por imagem , Escroto/diagnóstico por imagem , Idoso , Biópsia , Neoplasias dos Genitais Masculinos/patologia , Neoplasias dos Genitais Masculinos/cirurgia , Humanos , Masculino , Estadiamento de Neoplasias , Doença de Paget Extramamária/patologia , Doença de Paget Extramamária/cirurgia , Escroto/patologia , Escroto/cirurgia
9.
Eur Radiol ; 29(12): 6499-6507, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31175413

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of attenuation imaging (ATI) in the detection of hepatic steatosis compared with a histopathology gold standard. METHODS: We prospectively enrolled 108 consecutive patients (35 males; median age, 54.0 years) who underwent percutaneous liver biopsy for evaluation of diffuse liver disease between January 2018 and November 2018 in a tertiary academic center. Grayscale ultrasound examination with ATI was performed just before biopsy, and an attenuation coefficient (AC) was obtained from each patient. The degree of hepatic steatosis, fibrosis stage, and necroinflammatory activity were assessed on histopathologic examination. The significant factor associated with the AC was found by a linear regression analysis, and the diagnostic performance of the AC for the classification into each hepatic steatosis stage was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: The distribution of hepatic steatosis grade on histopathology was 53/11/22/16/6 for none/mild (< 10%)/mild (≥ 10%)/moderate/severe steatosis, respectively. The area under the ROC curve, sensitivity, specificity, and optimal cutoff AC value for detection of hepatic steatosis ranged from 0.843-0.926, 74.5-100.0%, 77.4-82.8%, and 0.635-0.745, respectively. Multivariate analysis revealed that the degree of steatosis was the only significant determinant factor for the AC. CONCLUSIONS: The AC from ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis. The degree of steatosis was the only significant factor affecting the AC, whereas fibrosis and inflammation were not. KEY POINTS: • Attenuation imaging (ATI) is based on two-dimensional grayscale ultrasound images that can incorporate into routine ultrasound examinations with less than 2 min of acquisition time. • ATI provided good diagnostic performance in detecting the varying degrees of hepatic steatosis with an area under the ROC curves ranging from 0.843 to 0.926, and there was no technical failure in this study indicating high applicability of this technique. • The degree of hepatic steatosis was the only significant factor affecting the result of ATI examination.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Adulto , Biópsia , Biópsia por Agulha , Estudos de Avaliação como Assunto , Fígado Gorduroso/patologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
10.
Radiol Med ; 123(4): 260-270, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29249077

RESUMO

OBJECTIVE: Thyroid nodules are common; however, malignancy is less than 7%. Therefore, additional techniques such as Doppler ultrasonography or elastography are used to improve diagnostic performance of conventional ultrasonography. We want to prospectively investigate the use of additional superb microvascular imaging (SMI) and strain elastography to B-mode ultrasound in thyroid nodules in distinguishing benign from malignant thyroid nodules. METHODS: We analyzed 52 thyroid nodules (malignant = 26, benign = 26) and reviewers scored the likelihood of malignancy for three data sets (i.e., B-mode ultrasonography alone, B-mode ultrasonography + SMI, and B-mode ultrasonography + strain elastography). The area under the receiver-operating characteristic curve (Az) values, sensitivities, and specificities were compared. RESULTS: A comparison of the data sets revealed that area under the receiver-operating characteristic curve values were similar without statistical difference. However, on comparing sensitivity and specificity based on the management decision of whether to conduct fine-needle aspiration (FNA) after combining information from all three types of imaging (B-mode ultrasonography + SMI + strain elastography), specificity was significantly higher for the combined technique (34.6%) than for B-mode ultrasonography alone (11.5%), without decrease in sensitivity (P = 0.032). CONCLUSION: Additional use of SMI and strain elastography could potentially lead to increase in specificity in thyroid ultrasonography.


Assuntos
Técnicas de Imagem por Elasticidade , Glândula Tireoide/irrigação sanguínea , Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/irrigação sanguínea , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Microvasos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
11.
J Ultrasound Med ; 37(1): 99-109, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28688156

RESUMO

OBJECTIVES: To compare the diagnostic performance of strain and shear wave elastography of breast masses for quantitative assessment in differentiating benign and malignant lesions and to evaluate the diagnostic accuracy of combined strain and shear wave elastography. METHODS: Between January and February 2016, 37 women with 45 breast masses underwent both strain and shear wave ultrasound (US) elastographic examinations. The American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) final assessment on B-mode US imaging was assessed. We calculated strain ratios for strain elastography and the mean elasticity value and elasticity ratio of the lesion to fat for shear wave elastography. Diagnostic performances were compared by using the area under the receiver operating characteristic curve (AUC). RESULTS: The 37 women had a mean age of 47.4 years (range, 20-79 years). Of the 45 lesions, 20 were malignant, and 25 were benign. The AUCs for elasticity values on strain and shear wave elastography showed no significant differences (strain ratio, 0.929; mean elasticity, 0.898; and elasticity ratio, 0.868; P > .05). After selectively downgrading BI-RADS category 4a lesions based on strain and shear wave elastographic cutoffs, the AUCs for the combined sets of B-mode US and elastography were improved (B-mode + strain, 0.940; B-mode + shear wave; 0.964; and B-mode, 0.724; P < .001). Combined strain and shear wave elastography showed significantly higher diagnostic accuracy than each individual elastographic modality (P = .031). CONCLUSIONS: These preliminary results showed that strain and shear wave elastography had similar diagnostic performance. The addition of strain and shear wave elastography to B-mode US improved diagnostic performance. The combination of strain and shear wave elastography results in a higher diagnostic yield than each individual elastographic modality.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Estudos de Avaliação como Assunto , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
J Korean Med Sci ; 32(12): 2079-2084, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29115095

RESUMO

Solid pseudopapillary tumor (SPT) is a low grade malignant tumor in the pancreas, and extrapancreatic SPT is extremely rare. We report a case of a 61-year-old woman who complained abdominal pain with diffuse tenderness. She was diagnosed with extrapancreatic SPT with extensive peritoneal dissemination and hepatic metastases. Although a few cases have reported imaging findings of extrapancreatic SPT, there have been no reports of extrapancreatic SPT with aggressive tumor behavior and dismal prognosis. Although imaging features closely resembled those of classical pancreatic SPTs, malignant transformation of extrapancreatic SPT should be considered when focal discontinuity of the tumor capsule with ill-defined margin and invasion of adjacent structures were identified.


Assuntos
Carcinoma Papilar/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Peritoneais/diagnóstico , Candida/isolamento & purificação , Carcinoma Papilar/diagnóstico por imagem , Carcinoma Papilar/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Neprilisina/metabolismo , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/patologia , Sepse/diagnóstico , Sepse/microbiologia , Tomografia Computadorizada por Raios X , Ultrassonografia , Vimentina/metabolismo
13.
AJR Am J Roentgenol ; 209(4): W211-W220, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28813195

RESUMO

OBJECTIVE: The objective of our study was to assess the value of CT texture analysis for prediction of therapeutic response of hepatocellular carcinoma (HCC) to transcatheter arterial chemoembolization (TACE) with pretherapeutic dynamic CT. MATERIALS AND METHODS: We retrospectively analyzed 132 HCCs in 96 patients treated with TACE who underwent dynamic CT before initial TACE. Imaging findings and arterial enhancement ratios were analyzed. All HCCs were manually segmented, and their texture features were quantitatively extracted using in-house software. CT texture was quantified with 2D and 3D analysis. HCCs were classified as with and without complete response (CR) according to modified Response Evaluation Criteria in Solid Tumors. Predictive factors for CR were assessed with multivariate analysis. Radiologic responses were correlated with time to progression (TTP). RESULTS: Of the 132 HCCs, CR was achieved in 75 (56.8%). Tumor size, subjective arterial tumor attenuation, and arterial enhancement ratios were significantly associated with CR. On 2D and 3D analysis, tumors with CR showed significantly lower homogeneity and higher mean attenuation, gray-level co-occurrence matrix (GLCM) moments, and CT number percentiles (p < 0.05). On multivariate analysis, higher subjective tumor attenuation (adjusted odds ratio [OR] = 23.35), arterial enhancement ratio (OR = 14.07), GLCM moments (OR = 6.57), smaller tumor size (OR = 17.26), and lower homogeneity (OR = 0.69) were significant predictors of CR compared with incomplete response (p < 0.05). Median survival value for TTP was significantly longer in tumors with CR (p < 0.001). CONCLUSION: Pretherapeutic dynamic CT texture analysis can be valuable to predict CR of HCC to TACE. Higher arterial enhancement and GLCM moments, lower homogeneity, and smaller tumor size are significant predictors of CR after TACE.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias , Cateterismo , Quimioembolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
14.
Liver Cancer ; 6(3): 189-203, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28626731

RESUMO

BACKGROUND: Rapid advances in liver imaging have improved the evaluation of hepatocarcinogenesis and early diagnosis and treatment of hepatocellular carcinoma (HCC). In this situation, detection of early-stage HCC in its development is important for the improvement of patient survival and optimal treatment strategies. Because early HCCs are considered precursors of progressed HCC, precise differentiation between a dysplastic nodule (DN), especially a high-grade DN, and early HCC is important. In clinical practice, these nodules are frequently called "borderline hepatic nodules." SUMMARY: This article discusses radiological and pathological characteristics of these borderline hepatic nodules and offers an understanding of multistep hepatocarcinogenesis by focusing on the descriptions of the imaging changes in the progression of DN and early HCC. Detection and accurate diagnosis of borderline hepatic nodules are still a challenge with contrast enhanced ultrasonography, CT, and MRI with extracellular contrast agents. However, gadoxetic acid-enhanced MRI may be useful for improving the diagnosis of these borderline nodules. KEY MESSAGES: Since there is a net effect of incomplete neoangiogenesis and decreased portal venous flow in the early stage of hepatocarcinogenesis, borderline hepatic nodules commonly show iso- or hypovascularity. Therefore, precise differentiation of these nodules remains a challenging issue. In MRI using hepatobiliary contrast agents, signal intensity of HCCs on hepatobiliary phase (HBP) is regarded as a potential imaging biomarker. Borderline hepatic nodules are seen as nonhypervascular and hypointense nodules on the HBP, which is important for predicting tumor behavior and determining appropriate therapeutic strategies.

15.
Ultrasound Med Biol ; 43(9): 2024-2032, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28641911

RESUMO

Factors affecting the registration error (RE) and motion of focal hepatic lesions (FHLs) in image fusion of real-time ultrasonography (US) with computed tomography (CT) images were prospectively assessed by focusing on respiratory movement and FHL location. Real-time US and pre-acquired CT images at end-inspiration were fused with FHLs for 103 patients. Three-dimensional US data containing FHLs were obtained during end-inspiratory/expiratory phases. Multivariate analysis revealed that diaphragm motion (p < 0.001), chronic liver disease (p = 0.02) and the absolute difference in distance between the FHL and the central portal vein (CPV) during respiration (p = 0.03) were the independent factors that revealed the maximum effect on RE. In contrast, diaphragm motion (p < 0.001) and distance between the FHL and CPV at inspiration (p = 0.036) revealed the maximum effect on FHL motion. In conclusion, RE and FHL motion are affected by the degree of respiratory movement and the location of the FHL. Therefore, image fusion with CT images should be used with caution if the degree of respiratory motion is significant or if the FHL is located at the periphery of the liver.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento , Imagem Multimodal/métodos , Estudos Prospectivos , Adulto Jovem
16.
Abdom Radiol (NY) ; 42(2): 442-450, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27654991

RESUMO

PURPOSE: To evaluate the diagnostic ability of multi-detector computed tomography (MDCT) compared to endoscopic ultrasonography (EUS) as a standard reference, and investigate the factors influencing the detection of small gastric subepithelial tumors (SETs) (<5 cm) on MDCT with stomach protocol. METHODS: We retrospectively investigated 70 patients who were suspected with gastric SETs on esophagogastroduodenoscopy (EGD), and underwent both EUS and computed tomographic (CT) scanning. EUS was performed by two gastroenterologists, and location, size, echotexture, echogenicity, and layer of origin were described when gastric SETs were detected on EUS. MDCTs were reviewed based on consensus of two radiologists blinded to the EUS result. Size, location, enhancement pattern, and contour of the lesion detected on CT were described. We calculated the diagnostic ability of CT compared to EUS with respect to detection of gastric SETs, and investigated the factors influencing detection of SETs on CT. We also used receiver operating characteristic (ROC) curve to obtain optimal cut-off size for predicting CT visibility of small SETs. RESULTS: Of the 70 patients, who underwent both CT and EUS due to suspicious presence of SET on EGD, EUS detected 56 probable cases of SET and 14 cases of external compression. CT led to detection of 39 cases of SET out of the 56 cases. Sensitivity and specificity of CT was 69.6% and 100.0%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) of CT were 100.0% and 45.2%, respectively. There was a significant difference in mean size of CT-detected lesions compared to CT-invisible lesions (14.36 mm vs. 8.52 mm, p < 0.001), but no significant differences in terms of layer of origin and location between these two groups (p > 0.5) were observed. The ROC analysis revealed that the optimal cut-off value, also referred to prediction of CT visibility, was 10 mm. Out of 70 cases, 26 cases (37.14%) were identified as external compression or insignificant lesions such as lipoma, hemangioma, lymphangioma, or gastritis cystica on CT, and do not require regular follow-up. CONCLUSIONS: Stomach CT shows good feasibility with respect to depiction of small SETs, especially in cases where size is larger than 10 mm. Henceforth, it is proposed that stomach CT would be a complimentary or problem-solving tool for SET in evaluating the presence of external compression and characterization of tumors.


Assuntos
Endossonografia , Neoplasias Gástricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Endoscopia do Sistema Digestório , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Korean J Radiol ; 17(5): 779-88, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27587968

RESUMO

OBJECTIVE: To investigate whether high-intensity focused ultrasound (HIFU) combined with microbubbles enhances the therapeutic effects of chemotherapy. MATERIALS AND METHODS: A pancreatic cancer xenograft model was established using BALB/c nude mice and luciferase-expressing human pancreatic cancer cells. Mice were randomly assigned to five groups according to treatment: control (n = 10), gemcitabine alone (GEM; n = 12), HIFU with microbubbles (HIFU + MB, n = 11), combined HIFU and gemcitabine (HIGEM; n = 12), and HIGEM + MB (n = 13). After three weekly treatments, apoptosis rates were evaluated using the terminal deoxynucleotidyl transferase-mediated dUTP nick end-labeling assay in two mice per group. Tumor volume and bioluminescence were monitored using high-resolution 3D ultrasound imaging and in vivo bioluminescence imaging for eight weeks in the remaining mice. RESULTS: The HIGEM + MB group showed significantly higher apoptosis rates than the other groups (p < 0.05) and exhibited the slowest tumor growth. From week 5, the tumor-volume-ratio relative to the baseline tumor volume was significantly lower in the HIGEM + MB group than in the control, GEM, and HIFU + MB groups (p < 0.05). Despite visible distinction, the HIGEM and HIGEM + MB groups showed no significant differences. CONCLUSION: High-intensity focused ultrasound combined with microbubbles enhances the therapeutic effects of gemcitabine chemotherapy in a pancreatic cancer xenograft model.


Assuntos
Antimetabólitos Antineoplásicos/uso terapêutico , Desoxicitidina/análogos & derivados , Microbolhas/uso terapêutico , Neoplasias Pancreáticas/terapia , Terapia por Ultrassom/métodos , Animais , Apoptose , Linhagem Celular Tumoral , Terapia Combinada , Desoxicitidina/uso terapêutico , Humanos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Carga Tumoral , Ultrassonografia , Ensaios Antitumorais Modelo de Xenoenxerto , Gencitabina
18.
Korean J Radiol ; 17(4): 509-21, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27390542

RESUMO

OBJECTIVE: To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). MATERIALS AND METHODS: 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of "SPL per se" and "SPL in consideration of secondary features", the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. RESULTS: The sensitivity of MRI for "detection of SPL per se" was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for "detection of SPL in consideration of secondary features", specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). CONCLUSION: MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Compostos Organometálicos/química , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Bases de Dados Factuais , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Neoplasias Pancreáticas
19.
Radiology ; 280(1): 88-97, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26844364

RESUMO

Purpose To evaluate the diagnostic performance of magnetic resonance (MR) elastography in staging liver fibrosis in patients with chronic hepatitis B (CHB) and other etiologic causes. Materials and Methods This retrospective study was institutional review board-approved and the requirement for informed consent was waived. Before surgery, MR elastographic imaging was performed in 352 patients with chronic liver diseases (281 patients with CHB, 71 patients without CHB) and hepatocellular carcinomas and 64 living liver donor candidates. Liver stiffness (LS) values were measured on quantitative shear-stiffness maps of MR elastography, and the diagnostic performance of MR elastography in staging liver fibrosis was evaluated by using receiver operating characteristic curve analysis and the Obuchowski measure with the histopathologic analysis of liver fibrosis in the CHB group and in the group composed of other etiologic causes. In 120 patients (97 with CHB, 23 without CHB) and 51 donors, diagnostic performance of MR elastography was validated. Results Areas under the curve of LS values for the diagnosis of significant fibrosis (≥stage F2), severe fibrosis (≥stage F3), and cirrhosis (stage F4) in the CHB group were 0.972 (95% confidence interval: 0.948, 0.987), 0.946 (95% confidence interval: 0.916, 0.968), and 0.920 (95% confidence interval: 0.885, 0.947), respectively. Obuchowski measures were similarly high in the CHB group and in the group composed of other etiologic causes (0.970 vs 0.977). However, the estimated cutoff value for stage F4 in the group with CHB was substantially lower than in the participants with other etiologic causes: 3.67 kPa versus 4.65 kPa. In the validation study for stage F1 or greater, stage F2 or greater, stage F3 or greater, and stage F4, the Youden indexes were 0.807, 0.842, 0.806, and 0.639, respectively, in the group with CHB, and 0.783, 0.900, 1.000, and 0.917, respectively, in the group without CHB. Conclusion The diagnostic performance of MR elastography in liver fibrosis staging was similarly high in the groups with and without CHB, but the cutoff LS values for diagnosing liver cirrhosis differed between the groups with and without CHB. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite B Crônica/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/etiologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Hepatopatias/complicações , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
20.
Radiology ; 279(3): 773-83, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26780538

RESUMO

Purpose To assess the diagnostic performance of gadoxetic acid-enhanced magnetic resonance (MR) imaging in the evaluation of portal vein thrombosis (PVT) in patients with hepatocellular carcinoma (HCC). Materials and Methods This retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. A total of 366 patients with HCC who underwent gadoxetic acid-enhanced MR imaging between January 2007 and May 2013, including 134 with malignant PVT, 49 with benign PVT, and 183 without PVT matched for age and sex, comprised our study population. PVTs were complete in 125 patients and partial in 58 and were located in a major portal vein (n = 159) or segmental portal vein (n = 24). Two radiologists independently reviewed the MR images and assessed the sensitivity, specificity, and accuracy in the detection and characterization of PVT according to location (major vs segmental) and type (complete vs partial). The Fisher exact or χ(2) test was used to evaluate sensitivity difference between the subsets. Results Gadoxetic acid-enhanced MR imaging showed good sensitivity (reviewer 1, 84% [154 of 183 patients]; reviewer 2, 70% [129 of 183 patients]) and high specificity (reviewer 1, 89% [163 of 183 patients]; reviewer 2, 96% [176 of 183 patients]) in the detection of PVT. Diagnostic accuracy for differentiating malignant PVT from benign PVT was high (reviewer 1, 92% [141 of 154 patients]; reviewer 2, 95% [122 of 129 patients]). However, there was slightly lower sensitivity for detecting segmental PVT compared with that of major PVT in the malignant PVT group (reviewer 1, 95% [104 of 110 patients] vs 88% [21 of 24 patients]; reviewer 2, 82% [90 of 110 patients] vs 79% [19 of 24 patients]; P = .203 and .775 for reviewers 1 and 2, respectively). Conclusion Gadoxetic acid-enhanced MR imaging provided good diagnostic performance in the detection of PVT and the differentiation of malignant from benign PVT in patients with HCC. However, caution is needed when evaluating potential candidates for curative treatment because of the low sensitivity for segmental PVT in the malignant PVT group. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular/complicações , Gadolínio DTPA/farmacologia , Neoplasias Hepáticas/complicações , Imageamento por Ressonância Magnética/métodos , Veia Porta , Trombose Venosa/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA