Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 12(9): 1274-1286, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32558326

RESUMO

The use of bioactive peptides as a doping agent in both human and animal sports has become increasingly popular in recent years. As such, methods to control the misuse of bioactive peptides in equine sports have received attention. This paper describes a sensitive accurate mass method for the detection of 40 bioactive peptides and two non-peptide growth hormone secretagogues (< 2 kDa) at low pg/mL levels in horse urine using ultra-high performance liquid chromatography-high resolution mass spectrometry (UHPLC/HRMS). A simple mixed-mode cation exchange solid-phase extraction (SPE) cartridge was employed for the extraction of 42 targets and/or their in vitro metabolites from horse urine. The final extract was analyzed using UHPLC/HRMS in positive electrospray ionization (ESI) mode under both full scan and data independent acquisition (DIA, for MS2 ). The estimated limits of detection (LoD) for most of the targets could reach down to 10 pg/mL in horse urine. This method was validated for qualitative detection purposes. The validation data, including method specificity, method sensitivity, extraction recovery, method precision, and matrix effect were reported. A thorough in vitro study was also performed on four gonadotrophin-releasing factors (GnRHs), namely leuprorelin, buserelin, goserelin, and nafarelin, using the S9 fraction isolated from horse liver. The identified in vitro metabolites have been incorporated into the method for controlling the misuse of GnRHs. The applicability of this method was demonstrated by the identification of leuprorelin and one of its metabolites, Leu M4, in urine obtained after intramuscular administration of leuprorelin to a thoroughbred gelding (castrated horse).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Detecção do Abuso de Substâncias/métodos , Animais , Dopagem Esportivo , Hormônio Liberador de Gonadotropina/análise , Hormônio Liberador de Gonadotropina/urina , Cavalos , Humanos , Leuprolida/análise , Leuprolida/urina , Limite de Detecção , Masculino , Peptídeos/urina , Reprodutibilidade dos Testes , Extração em Fase Sólida
2.
J Chromatogr A ; 1566: 51-63, 2018 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-29958683

RESUMO

Anabolic and androgenic steroids (AAS) are banned substances in both human and equine sports. They are often administered intramuscularly to horses in esterified forms for the purpose of extending their time of action. The authors' laboratory has previously reported an UHPLC/HRMS method using quadrupole-Orbitrap mass spectrometer in full scan and parallel reaction monitoring (PRM) mode for the detection of 48 AAS and/or their esters in horse hair. However, two injections were required due to the long duty cycle time. In this paper, an UHPLC/HRMS method using multiplexed targeted MS2 mode was developed and validated to improve the coverage to 65 AAS and/or their esters in a single injection. In addition, a GC/MS/MS method in selected reaction monitoring (SRM) mode was developed to screen for another seven AAS and/or their esters not adequately covered by the UHPLC/HRMS method using the same sample extract after derivatisation with pentafluoropropionic anhydride. The UHPLC/HRMS and GC/MS/MS methods in combination allowed the detection of 72 AAS and/or their esters with estimated limits of detection down to sub to low ppb levels with good interday precision. Method applicability was demonstrated by the detection of boldione and 4-androstenedione in two out-of-competition hair samples and testosterone propionate in a referee hair sample.


Assuntos
Cromatografia Líquida de Alta Pressão , Ésteres/análise , Cromatografia Gasosa-Espectrometria de Massas , Cabelo/química , Esteroides/análise , Espectrometria de Massas em Tandem , Androstenodiona/análise , Animais , Dopagem Esportivo , Ésteres/química , Cavalos , Esteroides/química , Propionato de Testosterona/análise
3.
J Chromatogr A ; 1546: 106-118, 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29548567

RESUMO

Methylstenbolone (2,17α-dimethyl-5α-androst-1-en-17ß-ol-3-one) is a synthetic anabolic and androgenic steroid (AAS) sold as an oral 'nutritional supplement' under the brand names 'Ultradrol', 'M-Sten' and 'Methyl-Sten'. Like other AASs, methylstenbolone is a prohibited substance in both human and equine sports. This paper describes the studies of the in vitro and in vivo metabolism of methylstenbolone in horses using LC/HRMS, GC/MS and GC/MS/MS. Phase I in vitro metabolic study of methylstenbolone was performed using homogenised horse liver. Hydroxylation was the only biotransformation observed. Six in vitro metabolites were detected including four mono-hydroxylated metabolites, namely 16α/ß-hydroxymethylstenbolone (M1a, M1b), 20-hydroxymethylstenbolone (M1c), 6-hydroxymethylstenbolone (M1d), and two dihydroxylated methylstenbolone metabolites (M2c-M2d). An in vivo experiment was carried out using two retired thoroughbred geldings. Each horse was administered with 100 mg methylstenbolone supplement by stomach tubing daily for three consecutive days. Methylstenbolone and 14 metabolites were detected in the post-administration urine samples. The proposed in vivo metabolites included 16α/ß-hydroxymethylstenbolone (M1a, M1b), 20-hydroxymethylstenbolone (M1c), two dihydroxylated methylstenbolone (M2a, M2b), 17-epi-methylstenbolone (M3), methasterone (M4), 2,17-dimethylandrostane-16,17-diol-3-one (M5), dihydroxylated and reduced methylstenbolone (M6), 2α,17α-dimethylandrostane-3α,17ß-diol (M7), 2,17-dimethylandrostane-3,16,17-triol (M8a-M8c) and 2,17-dimethylandrostane-2,3,16,17-tetraol (M9), formed from hydroxylation, reduction and epimerisation. Methylstenbolone and ten of its metabolites could be detected in post-administration plasma samples. The highest concentration of methylstenbolone detected in urine was about 10-36 ng/mL at 3-4 h after the last administration, while the maximum concentration in plasma was about 0.4-0.7 ng/mL at 1 h after the last administration. For controlling the misuse of methylstenbolone, M8c and M9 gave the longest detection time in urine, while M4, M5 and M6 were the longest detecting analytes in plasma. They could be detected for up to 5 and 4.5 days respectively in urine and plasma. Apart from 16α/ß-hydroxymethylstenbolone (M1a, M1b), the methylstenbolone metabolites reported herein have never been reported before.


Assuntos
Androstenóis/metabolismo , Cromatografia Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Administração Oral , Androstenóis/administração & dosagem , Androstenóis/química , Androstenóis/urina , Animais , Biotransformação , Cavalos , Fígado/metabolismo , Masculino
4.
Drug Test Anal ; 9(9): 1363-1371, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28407446

RESUMO

Acadesine, 5-aminoimidazole-4-carboxamide-1-ß-D-ribofuranoside, commonly known as AICAR, is a naturally occurring adenosine monophosphate-activated protein kinase (AMPK) activator in many mammals, including humans and horses. AICAR has attracted considerable attention recently in the field of doping control because of a study showing the enhancement of endurance performance in unexercised or untrained mice, resulting in the term 'exercise pill'. Its use has been classified as gene doping by the World Anti-Doping Agency (WADA), and since it is endogenous, it may only be possible to control deliberate administration of AICAR to racehorses after establishment of an appropriate threshold. Herein we report our studies of AICAR in post-race equine urine and plasma samples including statistical studies of AICAR concentrations determined from 1,470 urine samples collected from thoroughbreds and standardbreds and analyzed in Australia, France, and Hong Kong. Quantification methods in equine urine and plasma using liquid chromatography-mass spectrometry were developed by the laboratories in each country. An exchange of spiked urine and plasma samples between the three countries was conducted, confirming no significant differences in the methods. However, the concentration of AICAR in plasma was found to increase upon haemolysis of whole blood samples, impeding the establishment of a suitable threshold in equine plasma. A possible urine screening cut-off at 600 ng/mL for the control of AICAR in racehorses could be considered for adoption. Application of the proposed screening cut-off to urine samples collected after intravenous administration of a small dose (2 g) of AICAR to a mare yielded a short detection time of approximately 4.5 h. Copyright © 2017 John Wiley & Sons, Ltd.


Assuntos
Aminoimidazol Carboxamida/análogos & derivados , Dopagem Esportivo/prevenção & controle , Ribonucleosídeos/análise , Ribonucleotídeos/análise , Espectrometria de Massas em Tandem/métodos , Aminoimidazol Carboxamida/análise , Aminoimidazol Carboxamida/química , Aminoimidazol Carboxamida/metabolismo , Animais , Austrália , Cromatografia Líquida , Cavalos , Humanos , Ribonucleosídeos/química , Ribonucleosídeos/metabolismo , Ribonucleotídeos/química , Ribonucleotídeos/metabolismo , Urinálise
5.
Drug Test Anal ; 9(2): 317-322, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27001214

RESUMO

Xenon can activate the hypoxia-inducible factors (HIFs). As such, it has been allegedly used in human sports for increasing erythropoiesis. Krypton, another noble gas with reported narcosis effect, can also be expected to be a potential and less expensive erythropoiesis stimulating agent. This has raised concern about the misuse of noble gases as doping agents in equine sports. The aim of the present study is to establish a method for the simultaneous detection of xenon and krypton in equine plasma for the purpose of doping control. Xenon- or krypton-fortified equine plasma samples were prepared according to reported protocols. The target noble gases were simultaneously detected by gas chromatography-triple quadrupole mass spectrometry using headspace injection. Three xenon isotopes at m/z 129, 131, and 132, and four krypton isotopes at m/z 82, 83, 84, and 86 were targeted in selected reaction monitoring mode (with the precursor ions and product ions at identical mass settings), allowing unambiguous identification of the target analytes. Limits of detection for xenon and krypton were about 19 pmol/mL and 98 pmol/mL, respectively. Precision for both analytes was less than 15%. The method has good specificity as background analyte signals were not observed in negative equine plasma samples (n = 73). Loss of analytes under different storage temperatures has also been evaluated. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Hematínicos/sangue , Cavalos/sangue , Criptônio/sangue , Xenônio/sangue , Animais , Limite de Detecção , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA