Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 64: 1-4, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38355340

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) faces anatomical challenges, currently limiting widespread adoption. OBJECTIVES: To describe the natural history and prognosis of patients ineligible for various TMVR devices. METHODS: During a 4-year period (2019-2023) 3 TMVR devices (SAPIEN M3, Intrepid and Alta Valve) became available at a single institution (The Christ Hospital, Cincinnati, OH) in the setting of pivotal clinical trials or early feasibility study. Consenting patients who were deemed ineligible ≥1 of these trials were prospectively studied to capture anatomical reasons for ineligibility, cross-over to alternative mitral valve therapies (surgery or high-risk mitral transcatheter edge to edge repair [M-TEER]), and clinical events. RESULTS: A total of 61 patients (out of 71 consenting patients or 85.9 %) were deemed ineligible for TMVR during the study period. The mean age was 79.2 ± 8.8 years, 65.6 % were female, with elevated surgical risk (median STS 4.3, IQR: 2.7-7.3). The 2 most common anatomical reasons for ineligibility were increased risk of left ventricular outflow tract obstruction (LVOTO) (n = 24, 39.3 %) and annular size (n = 29, 47.5 %). During follow-up (median 277 [162-555] days) there were 7 deaths (11.5 %) and 12 (19.7 %) hospitalizations for heart failure. Management strategies included high-risk M-TEER in 11 patients (1 death [9.0 %], 0 HF hospitalizations [0 %]), surgery in 9 patients (0 deaths, 1 HF hospitalizations [11.1 %]), and medical management in 41 patients (6 deaths [14.6 %], 11 HF hospitalizations [26.8 %]) (p = 0.715 for mortality and p = 0.093 for HF hospitalizations). Residual MR ≥ moderate was 0 %, 50 %, and 100 % for surgery, M-TEER and medical treatment, respectively (p < 0.001). CONCLUSIONS: One third of patients deemed ineligible for TMVR are candidates for high-risk M-TEER or surgery with acceptable morbidity and mortality. Our results have practical implications for patient management.


Assuntos
Cateterismo Cardíaco , Definição da Elegibilidade , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Mitral , Seleção de Pacientes , Humanos , Feminino , Masculino , Idoso , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Tempo , Medição de Risco , Estudos Prospectivos , Recuperação de Função Fisiológica , Desenho de Prótese , Tomada de Decisão Clínica
2.
J Am Soc Echocardiogr ; 32(9): 1067-1074.e1, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31278049

RESUMO

BACKGROUND: Left ventricular filling pressure (LVFP) has been demonstrated to be a major predictor of poor cardiovascular outcomes. However, estimation of LVFP in patients with aortic stenosis is limited by the high prevalence of significant mitral annular calcification. The aim of this study was to investigate the effect of transcatheter aortic valve replacement on LVFP and the relationship of LVFP to mortality and hospitalization. METHODS: This was a single-center, retrospective study of 140 consecutive patients in sinus rhythm with significant mitral annular calcification who underwent transcatheter aortic valve replacement for severe aortic stenosis from May 2011 to June 2015. Mean follow-up duration was 3.06 ± 1.48 years (minimum, 2.4 years; maximum, 6.5 years). Diastolic function was assessed using recently proposed criteria for those with significant mitral annular calcification. High LVFP was defined as a mitral E/A ratio > 1.8 or a ratio of 0.8 to 1.8 and isovolumic relaxation time < 80 msec. RESULTS: At baseline, the proportion of patients with high LVFP was 40.7%, similar to 1 month (39.7%) (P = .86). However, the proportion of patients with high LVFP was significantly decreased at 1 year compared with those at baseline (26.9% vs 40.7%, P = .02). Multivariate analysis showed that high LVFP at baseline significantly increased risk for all-cause mortality compared with patients with normal LVFP (hazard ratio, 2.84; 95% confidence interval, 1.33-6.05; P = .007). CONCLUSIONS: High baseline LVFP was associated with a significantly increased all-cause mortality, and LVFP does not improve in the short term but only at 1 year after transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ventrículos do Coração/fisiopatologia , Estenose da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Calcinose/complicações , Calcinose/diagnóstico , Calcinose/fisiopatologia , Causas de Morte/tendências , Diástole , Ecocardiografia Doppler , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Heart ; 105(21): 1616-1621, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31171628

RESUMO

OBJECTIVES: Calcific aortic valve disease (CAVD) is a progressive disease ranging from aortic valve (AoV) sclerosis to AoV stenosis (AS), characterised by severe calcification with impaired leaflet function. Due to the lack of early symptoms, the pathological progression towards valve dysfunction is poorly understood. The early patterns of AoV calcification and altered extracellular matrix (ECM) organisation were analysed in individuals postmortem without clinical AS compared with clinical AS. METHODS: Histological patterns of calcification and ECM organisation in postmortem AoV leaflets without clinical AS obtained from a tissue repository and surgical specimens obtained from individuals with clinical AS were compared with in vivo imaging prior to transcatheter AoV implantation. RESULTS: AoV calcification was detected in all samples from individuals >50 years old, with severity increasing with age, independent of known CAVD risk factors. Two distinct types of calcification were identified: 'Intrinsic', primarily found at the leaflet hinge of postmortem leaflets, accompanied by abnormal collagen and proteoglycan deposition; and 'Nodular', extending from the middle to the tip regions in more severely affected postmortem leaflets and surgical specimens, associated with increased elastin fragmentation and loss of elastin integrity. Even in the absence of increased thickening, abnormalities in ECM composition were observed in postmortem leaflets without clinical AS and worsen in clinical AS. CONCLUSIONS: Two distinct phenotypes of AoV calcification are apparent. While the 'nodular' form is recognised on in vivo imaging and is present with CAVD and valve dysfunction, it is unclear if the 'intrinsic' form is pathological or detected on in vivo imaging.


Assuntos
Estenose da Valva Aórtica/patologia , Valva Aórtica/patologia , Calcinose/patologia , Matriz Extracelular/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Autopsia , Biópsia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Estudos de Casos e Controles , Progressão da Doença , Tecido Elástico/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter , Adulto Jovem
4.
Cardiovasc Intervent Radiol ; 32(4): 828-32, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19296159

RESUMO

Chylothorax carries significant mortality and morbidity. Patients with high-output chylothorax have traditionally been managed by surgical treatment if nonoperative management has proved unsuccessful. Newer, more recent percutaneous techniques used to treat chylothorax are safer and less invasive than surgery. We present three cases that have been successfully managed using these percutaneous techniques.


Assuntos
Quilotórax/terapia , Embolização Terapêutica/métodos , Adulto , Quilotórax/diagnóstico por imagem , Quilotórax/etiologia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Pleurodese , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X
5.
J Invasive Cardiol ; 15 Suppl A: 9A-13A, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12668834

RESUMO

Although randomized clinical trials have demonstrated efficacy of coronary irradiation versus placebo for the treatment of in-stent restenosis (ISR), durable long-term benefit in community practice is less well defined. From January 1, 2001, through June 30, 2002, consecutive percutaneous coronary intervention (n = 3,869) were analyzed at our center with a total of 330 patients undergoing coronary irradiation for ISR (53, Ir192; 12, P32; 265 Novoste Sr90). Novoste Sr90 was successfully performed in 265 of 270 (98%) of patients attempted by 10 operators. The mean patient age was 63 years (range 35 90) with 55% male (145/265) and 45% female (120/265). ISR anatomic subsets included multi-lesion (45/265; 17%), multi-vessel (27/265; 10.0%) and saphenous vein graft (16/265; 6.0%) interventions. At a mean follow-up of 10.5 2.8 (SD) months, fifty-three (20%) of the Novoste Sr90 treated patients had returned for symptoms requiring repeat angiography. Of these, 23 patients had repeat percutaneous coronary intervention (PCI) including 2 target site revascularizations (TSR), twelve non-TSR (distinct from the radiated segment of the target vessel), and 9 non-target vessel revascularizations (TVR). Coronary artery bypass surgery was performed in 11 total patients, 4 due to TSR, and 7 due to non-TVR. Clinical TSR was 2.3% (6/265) and TVR was 6.8% (18/265). In conclusion, the Novoste SR90 Beta-Cath System for the treatment of ISR is associated with a high procedural success rate and low TSR and TVR. Revascularization in follow-up is predominantly due to progressive disease outside the radiated segment and aggressive secondary prevention, especially prolonged anti-platelet therapy, appear critical to long-term procedural success.


Assuntos
Partículas beta/uso terapêutico , Serviços de Saúde Comunitária , Reestenose Coronária/radioterapia , Stents , Radioisótopos de Estrôncio/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Radiografia , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA