Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Trauma Acute Care Surg ; 87(1S Suppl 1): S132-S137, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31246917

RESUMO

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a severe form of acute lung injury with a mortality rate of up to 40%. Early management of ARDS has been difficult due to the lack of sensitive imaging tools and robust analysis software. We previously designed an optical coherence tomography (OCT) system to evaluate mucosa thickness (MT) after smoke inhalation, but the analysis relied on manual segmentation. The aim of this study is to assess in vivo proximal airway volume (PAV) after inhalation injury using automated OCT segmentation and correlate the PAV to lung function for rapid indication of ARDS. METHODS: Anesthetized female Yorkshire pigs (n = 14) received smoke inhalation injury (SII) and 40% total body surface area thermal burns. Measurements of PaO2-to-FiO2 ratio (PFR), peak inspiratory pressure (PIP), dynamic compliance, airway resistance, and OCT bronchoscopy were performed at baseline, postinjury, 24 hours, 48 hours, 72 hours after injury. A tissue segmentation algorithm based on graph theory was used to reconstruct a three-dimensional (3D) model of lower respiratory tract and estimate PAV. Proximal airway volume was correlated with PFR, PIP, compliance, resistance, and MT measurement using a linear regression model. RESULTS: Proximal airway volume decreased after the SII: the group mean of proximal airway volume at baseline, postinjury, 24 hours, 48 hours, 72 hours were 20.86 cm (±1.39 cm), 17.61 cm (±0.99 cm), 14.83 cm (±1.20 cm), 14.88 cm (±1.21 cm), and 13.11 cm (±1.59 cm), respectively. The decrease in the PAV was more prominent in the animals that developed ARDS after 24 hours after the injury. PAV was significantly correlated with PIP (r = 0.48, p < 0.001), compliance (r = 0.55, p < 0.001), resistance (r = 0.35, p < 0.01), MT (r = 0.60, p < 0.001), and PFR (r = 0.34, p < 0.01). CONCLUSION: Optical coherence tomography is a useful tool to quantify changes in MT and PAV after SII and burns, which can be used as predictors of developing ARDS at an early stage. LEVEL OF EVIDENCE: Prognostic, level III.


Assuntos
Lesão Pulmonar/diagnóstico por imagem , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Lesão por Inalação de Fumaça/diagnóstico por imagem , Tomografia de Coerência Óptica , Animais , Broncoscopia , Feminino , Lesão Pulmonar/complicações , Síndrome do Desconforto Respiratório/etiologia , Lesão por Inalação de Fumaça/complicações , Suínos
2.
Burns ; 45(3): 589-597, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30482414

RESUMO

BACKGROUND: The prevalence of acute respiratory distress syndrome (ARDS) in mechanically ventilated burn patients is 33%, with mortality varying from 11-46% depending on ARDS severity. Despite the new Berlin definition for ARDS, prompt bedside diagnosis is lacking. We developed and tested a bedside technique of fiberoptic-bronchoscopy-based optical coherence tomography (OCT) measurement of airway mucosal thickness (MT) for diagnosis of ARDS following smoke inhalation injury (SII) and burns. METHODS: 16 female Yorkshire pigs received SII and 40% thermal burns. OCT MT and PaO2-to-FiO2 ratio (PFR) measurements were taken at baseline, after injury, and at 24, 48, and 72h after injury. RESULTS: Injury led to thickening of MT which was sustained in animals that developed ARDS. Significant correlations were found between MT, PFR, peak inspiratory pressure (PIP), and total infused fluid volume. CONCLUSIONS: OCT is a useful tool to quantify MT changes in the airway following SII and burns. OCT may be effective as a diagnostic tool in the early stages of SII-induced ARDS and should be tested in humans.


Assuntos
Broncoscopia/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Mucosa Respiratória/diagnóstico por imagem , Lesão por Inalação de Fumaça/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Animais , Queimaduras por Inalação/complicações , Queimaduras por Inalação/diagnóstico por imagem , Queimaduras por Inalação/patologia , Feminino , Tamanho do Órgão , Pressão Parcial , Testes Imediatos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/patologia , Mucosa Respiratória/patologia , Lesão por Inalação de Fumaça/complicações , Lesão por Inalação de Fumaça/patologia , Sus scrofa , Suínos
3.
Sci Rep ; 6: 22792, 2016 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-26960250

RESUMO

Diagnosis and treatment of vocal fold lesions has been a long-evolving science for the otolaryngologist. Contemporary practice requires biopsy of a glottal lesion in the operating room under general anesthesia for diagnosis. Current in-office technology is limited to visualizing the surface of the vocal folds with fiber-optic or rigid endoscopy and using stroboscopic or high-speed video to infer information about submucosal processes. Previous efforts using optical coherence tomography (OCT) have been limited by small working distances and imaging ranges. Here we report the first full field, high-speed, and long-range OCT images of awake patients' vocal folds as well as cross-sectional video and Doppler analysis of their vocal fold motions during phonation. These vertical-cavity surface-emitting laser source (VCSEL) OCT images offer depth resolved, high-resolution, high-speed, and panoramic images of both the true and false vocal folds. This technology has the potential to revolutionize in-office imaging of the larynx.


Assuntos
Tomografia de Coerência Óptica/instrumentação , Disfunção da Prega Vocal/diagnóstico por imagem , Humanos , Laringoscopia/instrumentação , Laringoscopia/métodos , Tomografia de Coerência Óptica/métodos , Prega Vocal/diagnóstico por imagem
4.
Anal Chem ; 83(9): 3290-6, 2011 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21466206

RESUMO

Measuring the kinetic constants of protein-protein interactions at ultralow concentrations becomes critical in characterizing biospecific affinity, and exploring the feasibility of clinical diagnosis with respect to detection sensitivity, efficiency and accuracy. In this study, we propose a method that can calculate the binding constants of protein-protein interactions in sandwich assays at ultralow concentrations at the pg/mL level, using a localized surface plasmon coupled fluorescence fiber-optic biosensor (LSPCF-FOB). We discuss a two-compartment model to achieve reaction-limited kinetics under the stagnant conditions of the reaction chamber. The association rate constant, dissociation rate constant, and the equilibrium dissociation constant, that is, k(a), k(d), K(D), respectively, of the kinetics of binding between total prostate-specific antigen (t-PSA) and anti-t-PSA at concentrations from 0.1 pg/mL to 1 ng/mL, were measured either in PBS or in human serum. This is the first time that k(a), k(d), and K(D) have been measured at such a low concentration range in a complex sample such as human serum.


Assuntos
Técnicas Biossensoriais/métodos , Ouro/química , Nanopartículas Metálicas/química , Animais , Anticorpos Imobilizados/imunologia , Técnicas Biossensoriais/instrumentação , Bovinos , Humanos , Imunoglobulina G/imunologia , Cinética , Limite de Detecção , Camundongos , Fibras Ópticas , Ligação Proteica , Espectrometria de Fluorescência , Especificidade por Substrato
5.
Opt Express ; 17(21): 19213-24, 2009 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-20372658

RESUMO

This research proposed a dual-frequency heterodyne ellipsometer (DHE) in which a dual-frequency collinearly polarized laser beam with equal amplitude and zero phase difference between p- and s-polarizations is setup. It is based on the polarizer-sample-analyzer, PSA configuration of the conventional ellipsometer. DHE enables to characterize a generalized elliptical phase retarder by treating it as the combination of a linear phase retarder and a polarization rotator. The method for measuring elliptical birefringence of an elliptical phase retarder based on the equivalence theorem of an unitary optical system was derived and the experimental verification by use of DHE was demonstrated too. The experimental results show the capability of DHE on characterization of a generalized phase retardation plate accurately.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA