Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Zhonghua Xue Ye Xue Za Zhi ; 43(7): 562-567, 2022 Jul 14.
Artigo em Chinês | MEDLINE | ID: mdl-36709133

RESUMO

Objective: The study aims to establish a perfect BCR-ABL (P210) internal quality control system and ensure the long-term stability and comparability of the detection results between laboratories and to popularize and apply it in the three hospitals. Methods: The Qilu Hospital of Shandong University (H1) prepared a set of the BCR-ABL (P210) quality control substances to establish and improve internal quality control system. We went to other three participating hospitals (H2, H3, and H4) to inspect quality control before the measurement. In addition, we mailed 25 sets of quality control substances to each of the hospital for detection. The slope and intercept of the standard curve of each hospital and the detection results were analyzed and statistically judged using the Levey-Jennings quality control chart combined with the Westgard multirule theory. Then, we made a quality control evaluation. Results: ①An internal quality control system for the BCR-ABL (P210) transcript levels monitoring was successfully established for the quality inspection before the measurement, statistical judgment during the measurement, and evaluation after the measurement. ② Both the slope and intercept of the standard curve of the four hospitals was under control. ③The multicenter quality control substance judgment results were as follows: for H1 hospital, two times of "1(2s)" warning were found in the middle-level quality control substance, which was judged as being under control; for H2 hospital, one time of "1(2s)" warning was found for each quality control substance, which was judged as being "2(2s)" out of control; for H3 hospital, its high-level quality control substance violated the "1(3s)" rule, and low-level quality control substance appeared "1(2s)" warning, which was judged as "1(3s)" out of control; and all quality control substances were under control in H4 hospital. ④The quality control evaluation and correction were as follows: two hospitals were under control, and the other two hospitals had an "out of control." We found out the reason for the out of control and corrected them. ⑤The comparisons of the original values of the multicenter quality control substance were as follows: there were statistical differences in the results of high-level quality control substance among the four hospitals, and no significant difference was found in the results of the medium-level and low-level quality control substance. ⑥The comparisons of the IS values of the multicenter quality control substance were as follows: the IS values of the three quality control substance in H2 and H3 hospitals were significantly higher than those of H1 hospital, and H2 hospital was significantly higher than H3 hospital. Conclusion: A perfect and stable internal quality control system for the BCR-ABL (P210) transcripts has been established, which can effectively ensure the accuracy and stability of the clinical detection results. This internal quality control system has been successfully popularized and applied in other hospitals.


Assuntos
Proteínas de Fusão bcr-abl , Leucemia Mielogênica Crônica BCR-ABL Positiva , Humanos , Proteínas de Fusão bcr-abl/genética , Proteínas de Fusão bcr-abl/análise , Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Controle de Qualidade , Hospitais , Nonoxinol
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA