Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
J Thorac Cardiovasc Surg ; 168(1): 163-164, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38521492
2.
Ann Surg ; 279(5): 891-899, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37753657

RESUMO

OBJECTIVE: To associate surgeon-anesthesiologist team familiarity (TF) with cardiac surgery outcomes. BACKGROUND: TF, a measure of repeated team member collaborations, has been associated with improved operative efficiency; however, examination of its relationship to clinical outcomes has been limited. METHODS: This retrospective cohort study included Medicare beneficiaries undergoing coronary artery bypass grafting (CABG), surgical aortic valve replacement (SAVR), or both (CABG+SAVR) between January 1, 2017, and September 30, 2018. TF was defined as the number of shared procedures between the cardiac surgeon and anesthesiologist within 6 months of each operation. Primary outcomes were 30- and 90-day mortality, composite morbidity, and 30-day mortality or composite morbidity, assessed before and after risk adjustment using multivariable logistic regression. RESULTS: The cohort included 113,020 patients (84,397 CABG; 15,939 SAVR; 12,684 CABG+SAVR). Surgeon-anesthesiologist dyads in the highest [31631 patients, TF median (interquartile range)=8 (6, 11)] and lowest [44,307 patients, TF=0 (0, 1)] TF terciles were termed familiar and unfamiliar, respectively. The rates of observed outcomes were lower among familiar versus unfamiliar teams: 30-day mortality (2.8% vs 3.1%, P =0.001), 90-day mortality (4.2% vs 4.5%, P =0.023), composite morbidity (57.4% vs 60.6%, P <0.001), and 30-day mortality or composite morbidity (57.9% vs 61.1%, P <0.001). Familiar teams had lower overall risk-adjusted odds of 30-day mortality or composite morbidity [adjusted odds ratio (aOR) 0.894 (0.868, 0.922), P <0.001], and for SAVR significantly lower 30-day mortality [aOR 0.724 (0.547, 0.959), P =0.024], 90-day mortality [aOR 0.779 (0.620, 0.978), P =0.031], and 30-day mortality or composite morbidity [aOR 0.856 (0.791, 0.927), P <0.001]. CONCLUSIONS: Given its relationship with improved 30-day cardiac surgical outcomes, increasing TF should be considered among strategies to advance patient outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Medicare , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento
3.
Am J Surg ; 228: 279-286, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38030453

RESUMO

BACKGROUND: This study aims to examine the impact of home-to-transplantation center travel time as a potential barrier to healthcare accessibility. METHODS: Observational study examined adult heart transplant recipients who received a graft between 2012 and 2022 in the United States. Travel time was calculated using the Google Distance Matrix API between the recipient's residence and transplantation center. A multivariable parametric survival model was fitted to minimize confounding bias. RESULTS: Among the 25,923 recipients that met the selection criteria, the median travel time was 51 â€‹min and 95 â€‹% of recipients lived within a 5-h radius of their center. White recipients experienced longer median travel times (62 â€‹min, p â€‹< â€‹0.001) compared to Black (36 â€‹min) or Hispanic (40 â€‹min) recipients. A travel time of 1-2 â€‹h (survival time ratio [STR] 0.867, p â€‹= â€‹0.035) or >2 â€‹h (STR 0.873, p â€‹= â€‹0.026) away from the transplantation center was independently associated with lower long-term survival rates. CONCLUSION: Extended travel times to transplantation centers may negatively impact long-term survival outcomes for heart transplant recipients, suggesting the need to address this potential barrier to healthcare accessibility.


Assuntos
Transplante de Coração , Adulto , Humanos , Estados Unidos/epidemiologia , Atenção à Saúde , Fatores de Tempo , Viagem , Convulsões , Sobrevivência de Enxerto , Estudos Retrospectivos
4.
J Am Coll Cardiol ; 82(9): 771-781, 2023 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-37612008

RESUMO

BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m2 at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ponte de Artéria Coronária , Insuficiência Cardíaca/terapia , Hospitalização , Alta do Paciente
5.
Int J Surg ; 109(8): 2334-2343, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37204450

RESUMO

BACKGROUND: Cardiac surgery prediction models and outcomes from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) have not been reported. The authors sought to develop preoperative prediction models and estimates of postoperative outcomes for cardiac surgery using the ACS-NSQIP and compare these to the Society of Thoracic Surgeons Adult Cardiac Surgery Database (STS-ACSD). METHODS: In a retrospective analysis of the ACS-NSQIP data (2007-2018), cardiac operations were identified using cardiac surgeon primary specialty and sorted into cohorts of coronary artery bypass grafting (CABG) only, valve surgery only, and valve+CABG operations using CPT codes. Prediction models were created using backward selection of the 28 non-laboratory preoperative variables in ACS-NSQIP. Rates of nine postoperative outcomes and performance statistics of these models were compared to published STS 2018 data. RESULTS: Of 28 912 cardiac surgery patients, 18 139 (62.8%) were CABG only, 7872 (27.2%) were valve only, and 2901 (10.0%) were valve+CABG. Most outcome rates were similar between the ACS-NSQIP and STS-ACSD, except for lower rates of prolonged ventilation and composite morbidity and higher reoperation rates in ACS-NSQIP (all P <0.0001). For all 27 comparisons (9 outcomes × 3 operation groups), the c-indices for the ACS-NSQIP models were lower by an average of ~0.05 than the reported STS models. CONCLUSIONS: The ACS-NSQIP preoperative risk models for cardiac surgery were almost as accurate as the STS-ACSD models. Slight differences in c-indexes could be due to more predictor variables in STS-ACSD models or the use of more disease- and operation-specific risk variables in the STS-ACSD models.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgia Torácica , Adulto , Humanos , Estudos de Coortes , Estudos Retrospectivos , Melhoria de Qualidade , Sociedades Médicas , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Bases de Dados Factuais , Medição de Risco
6.
Circulation ; 147(16): 1221-1236, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-36876489

RESUMO

BACKGROUND: Increasing SERCA2 (sarco[endo]-plasmic reticulum Ca2+ ATPase 2) activity is suggested to be beneficial in chronic heart failure, but no selective SERCA2-activating drugs are available. PDE3A (phosphodiesterase 3A) is proposed to be present in the SERCA2 interactome and limit SERCA2 activity. Disruption of PDE3A from SERCA2 might thus be a strategy to develop SERCA2 activators. METHODS: Confocal microscopy, 2-color direct stochastic optical reconstruction microscopy, proximity ligation assays, immunoprecipitations, peptide arrays, and surface plasmon resonance were used to investigate colocalization between SERCA2 and PDE3A in cardiomyocytes, map the SERCA2/PDE3A interaction sites, and optimize disruptor peptides that release PDE3A from SERCA2. Functional experiments assessing the effect of PDE3A-binding to SERCA2 were performed in cardiomyocytes and HEK293 vesicles. The effect of SERCA2/PDE3A disruption by the disruptor peptide OptF (optimized peptide F) on cardiac mortality and function was evaluated during 20 weeks in 2 consecutive randomized, blinded, and controlled preclinical trials in a total of 148 mice injected with recombinant adeno-associated virus 9 (rAAV9)-OptF, rAAV9-control (Ctrl), or PBS, before undergoing aortic banding (AB) or sham surgery and subsequent phenotyping with serial echocardiography, cardiac magnetic resonance imaging, histology, and functional and molecular assays. RESULTS: PDE3A colocalized with SERCA2 in human nonfailing, human failing, and rodent myocardium. Amino acids 277-402 of PDE3A bound directly to amino acids 169-216 within the actuator domain of SERCA2. Disruption of PDE3A from SERCA2 increased SERCA2 activity in normal and failing cardiomyocytes. SERCA2/PDE3A disruptor peptides increased SERCA2 activity also in the presence of protein kinase A inhibitors and in phospholamban-deficient mice, and had no effect in mice with cardiomyocyte-specific inactivation of SERCA2. Cotransfection of PDE3A reduced SERCA2 activity in HEK293 vesicles. Treatment with rAAV9-OptF reduced cardiac mortality compared with rAAV9-Ctrl (hazard ratio, 0.26 [95% CI, 0.11 to 0.63]) and PBS (hazard ratio, 0.28 [95% CI, 0.09 to 0.90]) 20 weeks after AB. Mice injected with rAAV9-OptF had improved contractility and no difference in cardiac remodeling compared with rAAV9-Ctrl after aortic banding. CONCLUSIONS: Our results suggest that PDE3A regulates SERCA2 activity through direct binding, independently of the catalytic activity of PDE3A. Targeting the SERCA2/PDE3A interaction prevented cardiac mortality after AB, most likely by improving cardiac contractility.


Assuntos
Nucleotídeo Cíclico Fosfodiesterase do Tipo 3 , Insuficiência Cardíaca , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático , Animais , Humanos , Camundongos , Cálcio/metabolismo , Nucleotídeo Cíclico Fosfodiesterase do Tipo 3/genética , Nucleotídeo Cíclico Fosfodiesterase do Tipo 3/metabolismo , Insuficiência Cardíaca/metabolismo , Células HEK293 , Miocárdio/metabolismo , Miócitos Cardíacos/metabolismo , Retículo Sarcoplasmático/metabolismo , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático/metabolismo
7.
J Thorac Cardiovasc Surg ; 165(3): e90-e99, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34763893

RESUMO

OBJECTIVES: The mitochondrial adenosine triphosphate-sensitive potassium channel is central to pharmacologically induced tolerance to spinal cord injury. We hypothesized that both direct and nitric oxide-dependent indirect activation of the adenosine triphosphate-sensitive potassium channel contribute to the induction of ischemic metabolic tolerance. METHODS: Spinal cord injury was induced in adult male C57BL/6 mice through 7 minutes of thoracic aortic crossclamping. Pretreatment consisted of intraperitoneal injection 3 consecutive days before injury. Experimental groups were sham (no pretreatment or ischemia, n = 10), spinal cord injury control (pretreatment with normal saline, n = 27), Nicorandil 1.0 mg/kg (direct and indirect adenosine triphosphate-sensitive potassium channel opener, n = 20), Nicorandil 1 mg/kg + carboxy-PTIO 1 mg/kg (nitric oxide scavenger, n = 21), carboxy-PTIO (n = 12), diazoxide 5 mg/kg (selective direct adenosine triphosphate-sensitive potassium channel opener, n = 25), and DZ 5 mg/kg+ carboxy-PTIO 1 mg/kg, carboxy-PTIO (n = 23). Limb motor function was assessed using the Basso Mouse Score (0-9) at 12-hour intervals for 48 hours after ischemia. RESULTS: Motor function was significantly preserved at all time points after ischemia in the Nicorandil pretreatment group compared with ischemic control. The addition of carboxy-PTIO partially attenuated Nicorandil's motor-preserving effect. Motor function in the Nicorandil + carboxy-PTIO group was significantly preserved compared with the spinal cord injury control group (P < .001), but worse than in the Nicorandil group (P = .078). Motor preservation in the diazoxide group was similar to the Nicorandil + carboxy-PTIO group. There was no significant difference between the diazoxide and diazoxide + carboxy-PTIO groups. CONCLUSIONS: Both direct and nitric oxide-dependent indirect activation of the mitochondrial adenosine triphosphate-sensitive potassium channel play an important role in pharmacologically induced motor function preservation.


Assuntos
Diazóxido , Traumatismos da Medula Espinal , Masculino , Camundongos , Animais , Diazóxido/farmacologia , Nicorandil/farmacologia , Trifosfato de Adenosina/metabolismo , Canais de Potássio , Óxido Nítrico/metabolismo , Camundongos Endogâmicos C57BL , Isquemia
8.
J Thorac Cardiovasc Surg ; 165(2): 735-736, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33867128

Assuntos
Coração , Viagem , Humanos , Tórax
9.
J Thorac Cardiovasc Surg ; 166(6): 1684-1694.e18, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35643769

RESUMO

BACKGROUND: Correction of valvular disease is often undertaken during left ventricular assist device (LVAD) implantation with uncertain benefit. We analyzed clinical outcomes with HeartMate 3 (HM3; Abbott) LVAD implantation in those with various concurrent valve procedures (HM3+VP) with those with an isolated LVAD implant (HM3 alone). METHODS: The study included 2200 patients with HM3 implanted within the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) trial portfolio who underwent 820 concurrent procedures among which 466 (21.8%) were HM3+VP. VPs included 101 aortic, 61 mitral, 163 tricuspid; 85 patients had multiple VPs. Perioperative complications, major adverse events, and survival were analyzed. RESULTS: Patients who underwent HM3+VP had higher-acuity Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles (1-2: 41% vs 31%) compared with no VPs (P < .05). The cardiopulmonary bypass time (124 vs 76 minutes; P < .0001) and hospital length of stay (20 vs 18 days; P < .0001) were longer in HM3+VP. A higher incidence of stroke (4.9% vs 2.4%), bleeding (33.9% vs 23.8%), and right heart failure (41.5% vs 29.6%) was noted in HM3+VP at 0 to 30 days (P < .01), with no difference in 30-day mortality (3.9% vs 3.3%) or 2-year survival (81.7% vs 80.8%). Analysis of individual VP showed no differences in survival compared to HM3 alone. No differences were noted among patients with either significant mitral (moderate or worse) or tricuspid (moderate or worse) regurgitation with or without corrective surgery. CONCLUSIONS: Concurrent VPs, commonly performed during LVAD implantation, are associated with increased morbidity during the index hospitalization, with no effect on short- and long-term survival. There is sufficient equipoise to consider a randomized trial on the benefit of commonly performed VPs (such as mitral or tricuspid regurgitation correction), during LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Procedimentos Cirúrgicos Torácicos , Humanos , Catéteres , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Estudos Multicêntricos como Assunto
10.
JACC Heart Fail ; 10(12): 948-959, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36456068

RESUMO

BACKGROUND: Clinical trials inform on average efficacy, but individualized risk assessments for outcome prediction are important in guiding treatment implementation. OBJECTIVES: The authors developed and validated a patient-specific risk score to predict survival at 1 and 2 years after HeartMate 3 (HM3) left ventricular assist device (LVAD) implantation. METHODS: The MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3) trial includes 2,200 HM3 LVAD patients in the pivotal trial and Continued Access Protocol study (2014-2018). The authors randomly assigned all patients to a derivation cohort (n = 1,540) or validation cohort (n = 660). Univariate mortality predictors were screened for potential model inclusion, stepwise selection was used to build the multivariable Cox proportional hazards regression model, and performance (discrimination and calibration) was evaluated. RESULTS: Age, prior cardiac surgery (coronary artery bypass grafting [CABG] or valve procedure), lower serum sodium, higher blood urea nitrogen (BUN), small left ventricular size, and right atrial pressure-to-pulmonary capillary wedge pressure (RAP/PCWP) ratio >0.6 were significant risk factors for mortality. Receiver-operating characteristic (ROC) analysis in the validation cohort demonstrated an area under the curve (AUC) of 0.76 (95% CI: 0.70-0.81) at 1 year and 0.71 (95% CI: 0.66-0.77) at 2 years. Calibration between predicted and observed survival of the risk quintiles was high, with Pearson correlation coefficients of 0.986 and 0.994 at 1 and 2 years, respectively. Patients were successfully stratified into tertiles with higher-than-average, average, and lower-than-average survival, and observed mortality risk increased by 2-fold from one tertile to the next. CONCLUSIONS: A practical, easy-to-use HM3 Survival Risk Score with 6 components was developed to accurately predict 1- and 2-year survival after HM3 LVAD implantation. The survival risk score can be used to provide individual survival estimates to facilitate shared decision making when considering HM3 LVAD therapy. (MOMENTUM 3 Trial Portfolio; NCT02224755, NCT02892955).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/terapia , Fatores de Risco , Pressão Propulsora Pulmonar , Medição de Risco
11.
J Am Coll Cardiol ; 80(22): 2119-2134, 2022 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-36423996

RESUMO

The treatment of left main (LM) coronary artery disease (CAD) requires complex decision-making. Recent clinical practice guidelines provide clinicians with guidance; however, decisions regarding treatment for individual patients can still be difficult. The American College of Cardiology's Cardiac Surgery Team and Interventional Council joined together to develop a practical approach to the treatment of LM CAD, taking into account randomized clinical trial, meta-analyses, and clinical practice guidelines. The various presentations of LM CAD based on anatomy and physiology are presented. Recognizing the complexity of LM CAD, which rarely presents isolated and is often in combination with multivessel disease, a treatment algorithm with medical therapy alone or in conjunction with percutaneous coronary intervention or coronary artery bypass grafting is proposed. A heart team approach is recommended that accounts for clinical, procedural, operator, and institutional factors, and features shared decision-making that meets the needs and preferences of each patient and their specific clinical situation.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Metanálise como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Guias de Prática Clínica como Assunto
12.
Mol Cell ; 82(19): 3661-3676.e8, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36206740

RESUMO

Mitochondrial Ca2+ uptake, mediated by the mitochondrial Ca2+ uniporter, regulates oxidative phosphorylation, apoptosis, and intracellular Ca2+ signaling. Previous studies suggest that non-neuronal uniporters are exclusively regulated by a MICU1-MICU2 heterodimer. Here, we show that skeletal-muscle and kidney uniporters also complex with a MICU1-MICU1 homodimer and that human/mouse cardiac uniporters are largely devoid of MICUs. Cells employ protein-importation machineries to fine-tune the relative abundance of MICU1 homo- and heterodimers and utilize a conserved MICU intersubunit disulfide to protect properly assembled dimers from proteolysis by YME1L1. Using the MICU1 homodimer or removing MICU1 allows mitochondria to more readily take up Ca2+ so that cells can produce more ATP in response to intracellular Ca2+ transients. However, the trade-off is elevated ROS, impaired basal metabolism, and higher susceptibility to death. These results provide mechanistic insights into how tissues can manipulate mitochondrial Ca2+ uptake properties to support their unique physiological functions.


Assuntos
Proteínas de Ligação ao Cálcio/metabolismo , Cálcio , Proteínas de Transporte de Cátions/metabolismo , Proteínas de Transporte da Membrana Mitocondrial/metabolismo , Trifosfato de Adenosina , Animais , Cálcio/metabolismo , Canais de Cálcio , Proteínas de Ligação ao Cálcio/genética , Dissulfetos/metabolismo , Humanos , Camundongos , Proteínas de Transporte da Membrana Mitocondrial/genética , Espécies Reativas de Oxigênio/metabolismo
13.
Am J Surg ; 224(4): 1057-1061, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35934556

RESUMO

BACKGROUND: The appropriate stent length in frozen elephant trunk replacements (FET) remains debated relative to the risk for paraplegia. However, landing the distal end of the stent beyond the curve of the arch facilitates distal reintervention, which is commonly beyond the 10 cm stent coverage when deployed proximal to the left subclavian artery. The aim of this study was to evaluate outcomes following the use of 15 cm stent grafts in zone 2 (z2, distal to the left common carotid). METHODS: Using our single institution-maintained database, 103 zone 2 FET performed from 2016 to 2020 were reviewed. RESULTS: Of the 103 z2, a 15 cm stent graft was used in 51 operations. The indications for FET included acute and chronic aortic dissection, arch aneurysms, and pseudoaneurysms. The incidence of SCI was 0%. Seven deaths (13.7%) occurred. CONCLUSIONS: The data demonstrates the incidence of post-operative paraplegia to be 0% with 15 cm z2 FET. The understanding of SCI in FET should not only include the stent length but also from where it begins.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Isquemia do Cordão Espinal , Aorta Torácica , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Humanos , Paraplegia/etiologia , Paraplegia/cirurgia , Estudos Retrospectivos , Isquemia do Cordão Espinal/complicações , Isquemia do Cordão Espinal/etiologia , Stents/efeitos adversos , Resultado do Tratamento
14.
Ann Thorac Surg ; 114(5): 1542-1549, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35963441

RESUMO

Reimbursement for cardiothoracic surgery continues to be threatened with enormous financial cuts ranging from 5% to 10% in recent years. In this policy perspective, we describe the history of reimbursement for cardiothoracic surgery, highlight areas in need of urgent reform, propose possible solutions that Congress and the Executive Branch may enact, and call cardiothoracic surgeons to action on this critical issue. Meaningful engagement of members of The Society of Thoracic Surgeons with their elected representatives is the only way to prevent these cuts.


Assuntos
Especialidades Cirúrgicas , Cirurgia Torácica , Idoso , Estados Unidos , Humanos , Medicare
16.
Semin Cardiothorac Vasc Anesth ; 26(2): 154-161, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35591803

RESUMO

Cardiac surgery continues to evolve. The last year has been notable for many reasons. The guidelines for coronary revascularization introduced significant discord. The pandemic continues to affect the care on a global scale. Advances in organ procurement and dissection care move forward with better understanding and better technology.


Assuntos
COVID-19 , Procedimentos Cirúrgicos Cardíacos , Transplante de Coração , Obtenção de Tecidos e Órgãos , Morte , Humanos
18.
Ann Thorac Surg ; 114(6): 2262-2269, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35452663

RESUMO

BACKGROUND: Outcomes in patients with smaller body size after HeartMate 3 left ventricular assist device (HM3) implantation are not well characterized. We sought to evaluate outcomes in smaller vs larger body surface area (BSA) patients in the MOMENTUM 3 pivotal trial and its Continued Access Protocol cohort. METHODS: The analysis cohort included 1015 HM3 patients divided into 2 groups: BSA ≤1.70 m2 (small patients, n = 82) and BSA >1.70 m2 (large patients, n = 933). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or to remove a malfunctioning device. Adverse events were compared between groups. RESULTS: Smaller patients were more frequently women (56.1% vs 17.7%; P < .001) and had lower prevalence of diabetes (28.1% vs 43.9%; P = .005) and hypertension (51.2% vs 71.9%; P < .001), larger median indexed LVEDD (normalized by BSA, 40 vs 33 mm/m2; P < .001), and lower median serum creatinine concentration (1.1 vs 1.3 mg/dL; P < .001). The proportion of patients achieving the composite end point at 2 years was 77% in both groups (adjusted hazard ratio, 1.14; 95% CI, 0.68-1.91; P = .62). Two-year adverse event rates were also similar between groups except for sepsis (6.1% vs 14.9%; P = .029) and cardiac arrhythmias (24.4% vs 35.3%; P = .005), which were higher in the larger patients. CONCLUSIONS: Outcomes after HM3 implantation were comparable between small and large patients. Smaller body size should not be used to deny HM3 implantation in patients who are otherwise suitable candidates for durable mechanical circulatory support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Feminino , Humanos , Tamanho Corporal , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
19.
Ann Thorac Surg ; 114(3): 676-682, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35183504

RESUMO

BACKGROUND: the incidence of organ donation after circulatory death (DCD) is increasing; however, heart use has lagged behind other solid organs. Ex vivo perfusion devices are under United States Food and Drug Administration review for use in DCD heart recovery. This study sought to measure the potential increase in the donor pool if DCD heart donation becomes widely adopted. METHODS: DCD donor data were obtained from Organ Procurement and Transplantation Network database. Selection criteria included donor age 18 to 49 years, donors meeting Maastricht III criteria, warm ischemia time ≤30 minutes, and donation between 2015 and 2020. Exclusion criteria were coronary disease, prior myocardial infarction, ejection fraction <0.50, significant valve disease, bacteremia, pulmonary capillary wedge pressure >15 mm Hg, and history of HIV/hepatitis C virus infections. RESULTS: There were 12 813 DCD donors during this period, of which 3528 met study criteria, and 70 hearts (2%) were transplanted. The use of DCD hearts would represent an additional 48 heart transplants per month, which corresponds to a 21% (3458 of 16 521) increase across the country. Median warm ischemia was 23 minutes, with no difference between hearts that were or were not transplanted (23 vs 22.5 minutes, P = .97). The frequency with which other organs were successfully transplanted was kidney, 92%; liver, 44%; lung, 7%; intestine, 0%; and pancreas, 2%. CONCLUSIONS: Wide adoption of DCD heart transplantation could yield a substantial increase in the donor pool size, with approximately 580 additional organs being available each year across the United States. This would represent the largest increase in the donor pool in the modern era of heart transplantation.


Assuntos
Transplante de Coração , Obtenção de Tecidos e Órgãos , Adolescente , Adulto , Morte , Coração , Humanos , Pessoa de Meia-Idade , Doadores de Tecidos , Isquemia Quente , Adulto Jovem
20.
Am J Surg ; 224(1 Pt B): 437-442, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34980465

RESUMO

BACKGROUND: The COVID-19 pandemic has uniquely affected the United States. We hypothesize that transplantation would be uniquely affected. METHODS: In this population-based cohort study, adult transplantation data were examined as time series data. Autoregressive-integrated-moving-average models of transplantation rates were developed using data from 1990 to 2019 to forecast the 2020 expected rates in a theoretical scenario if the pandemic did not occur to generate observed-to-expected (O/E) ratios. RESULTS: 32,594 transplants were expected in 2020, and only 30,566 occurred (O/E 0.94, CI 0.88-0.99). 58,152 waitlist registrations were expected and 50,241 occurred (O/E 0.86, CI 0.80-0.94). O/E ratios of transplants were kidney 0.92 (0.86-0.98), liver 0.96 (0.89-1.04), heart 1.05 (0.91-1.23), and lung 0.92 (0.82-1.04). O/E ratios of registrations were kidney 0.84 (0.77-0.93), liver 0.95 (0.86-1.06), heart 0.99 (0.85-1.18), and lung 0.80 (0.70-0.94). CONCLUSIONS: The COVID-19 pandemic was associated with a significant deficit in transplantation. The impact was strongest in kidney transplantation and waitlist registration.


Assuntos
COVID-19 , Transplante de Órgãos , Adulto , COVID-19/epidemiologia , Estudos de Coortes , Humanos , Pandemias , Estados Unidos/epidemiologia , Listas de Espera
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA