Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Cell Rep Med ; 5(6): 101608, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38866015

RESUMO

While mutational signatures provide a plethora of prognostic and therapeutic insights, their application in clinical-setting, targeted gene panels is extremely limited. We develop a mutational representation model (which learns and embeds specific mutation signature connections) that enables prediction of dominant signatures with only a few mutations. We predict the dominant signatures across more than 60,000 tumors with gene panels, delineating their landscape across different cancers. Dominant signature predictions in gene panels are of clinical importance. These included UV, tobacco, and apolipoprotein B mRNA editing enzyme, catalytic polypeptide (APOBEC) signatures that are associated with better survival, independently from mutational burden. Further analyses reveal gene and mutation associations with signatures, such as SBS5 with TP53 and APOBEC with FGFR3S249C. In a clinical use case, APOBEC signature is a robust and specific predictor for resistance to epidermal growth factor receptor-tyrosine kinase inhibitors (EGFR-TKIs). Our model provides an easy-to-use way to detect signatures in clinical setting assays with many possible clinical implications for an unprecedented number of cancer patients.


Assuntos
Mutação , Neoplasias , Humanos , Mutação/genética , Neoplasias/genética , Receptores ErbB/genética , Inibidores de Proteínas Quinases/farmacologia , Proteína Supressora de Tumor p53/genética , Redes Neurais de Computação , Receptor Tipo 3 de Fator de Crescimento de Fibroblastos/genética
2.
Med Phys ; 51(6): 3822-3849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38648857

RESUMO

Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.


Assuntos
Imobilização , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/instrumentação , Humanos , Imobilização/instrumentação , Radioterapia Guiada por Imagem/instrumentação
3.
Foods ; 12(16)2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37628115

RESUMO

Kombucha is a fermented tea beverage consumed for its probiotics and functional properties. It has a unique sensory profile driven by the properties of tea polyphenols and fermentation products, including organic acids. Fermentation temperature and sucrose content affect the fermentation process and the production of organic acids; yet less is known about their impacts on the sensory profile and consumer acceptance. Thus, we aimed to examine the impact of sucrose concentration and fermentation temperature on sensory attributes and liking. For this study, kombucha tea was fermented at three different concentrations of sucrose and fermented at two temperatures for 11 days. Fermentation was monitored by pH, brix, and titratable acidity, and consumers (n = 111) evaluated the kombucha for sensory attributes and overall liking. The fermentation temperature resulted in significant differences in titratable acidity, with higher temperatures producing more organic acids, resulting in higher astringency, and suppressed sweetness. The lower fermentation was reported as significantly more liked, with no difference in liking between the 7.5% and 10% sucrose kombucha samples. Fermentation temperature had the greatest impact on the sensory profile rather than sucrose concentration, which had a greater effect on the fermentation rate and production organic acids.

4.
JAMA Netw Open ; 6(5): e2312824, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37166798

RESUMO

Importance: Patients with recurrent or unresectable skin cancers have limited treatment options. Diffusing alpha-emitter radiation therapy (DaRT), a novel solid tumor management strategy using alpha-particle interstitial brachytherapy, may address this challenge. Objective: To evaluate the feasibility and safety of using DaRT to manage recurrent or unresectable skin cancers. Design, Setting, and Participants: This prospective cohort study of patients who received a 2-week to 3-week treatment course and were followed up for 24 weeks after treatment during 2021 and 2022 at 2 sites in the US. Patients with malignant skin tumors or soft tissue tumors were recruited if they had limited treatment options for tumors recurrent after prior surgery or external beam radiotherapy or unresectable tumors. Intervention: Patients underwent DaRT to deliver a physical dose of 10 Gy (equivalent weighted dose of 200 CGE) to the tumor. Main Outcomes and Measures: Feasibility of the DaRT procedure was evaluated based on the ability of investigators to successfully deliver radiation to the tumor. Patients were followed up for adverse events (AEs) for 24 weeks and for tumor response by physicians' physical examination and imaging 12 weeks after device removal. Results: This study included 10 participants with recurrent or unresectable skin cancer (median [IQR] age, 72 [68-75] years; 6 males [60%]; 4 females [40%]). Six patients (60%) had recurrent disease, and 4 (40%) had tumors that were deemed unresectable. Tumors were located on the nose, chin, eyelid, scalp, neck, trunk, and extremities. Median (range) tumor volume before treatment was 2.1 cm3 (0.65-12.65 cm3). The mean (SD) prescription dose coverage of the gross tumor volume was 91% (2.8%) with all tumors having coverage of 85% or more. No device-related grade 3 AEs were noted. Common AEs were grade 1 to 2 erythema, edema, and pruritus. At 12 weeks following treatment, there was a 100% complete response rate. Nine of 10 complete responses (90%) were confirmed by CT imaging. Conclusions and Relevance: This cohort study suggests the feasibility and preliminary safety of DaRT in the management of recurrent or unresectable skin cancers. The favorable safety profile and high response rates are promising. A US trial for marketing approval based on this pilot study is under way. Trial Registration: ClinicalTrials.gov Identifier: NCT04377360.


Assuntos
Braquiterapia , Neoplasias Cutâneas , Masculino , Feminino , Humanos , Idoso , Braquiterapia/efeitos adversos , Estudos de Coortes , Estudos Prospectivos , Projetos Piloto , Estudos de Viabilidade , Neoplasias Cutâneas/radioterapia
5.
J Appl Clin Med Phys ; 24(3): e13829, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36808798

RESUMO

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines (MPPGs) will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (1) Must and must not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (2) Should and should not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee April 28, 2022.


Assuntos
Braquiterapia , Radioterapia (Especialidade) , Humanos , Estados Unidos , Física Médica/educação , Sociedades
6.
Mol Oncol ; 17(9): 1844-1856, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36694946

RESUMO

Genomic analysis, performed on tumoral tissue DNA and on circulating tumor DNA (ctDNA) from blood, is the cornerstone of precision cancer medicine. Herein, we characterized the clinical prognostic implications of the concordance of alterations in major cancer genes between tissue- and blood-derived DNA in a pan-cancer cohort. The molecular profiles of both liquid (Guardant Health) and tissue (Foundation Medicine) biopsies from 433 patients were analyzed. Mutations and amplifications of cancer genes scored by these two tests were assessed. In 184 (42.5%) patients, there was at least one mutual gene alteration. The mean number of mutual gene-level alterations in the samples was 0.67 per patient (range: 0-5). A higher mutual gene-level alteration number correlated with shorter overall survival (OS). As confirmed in multivariable analysis, patients with ≥2 mutual gene-level alterations in blood and tissue had a hazard ratio (HR) of death of 1.49 (95% confidence interval [CI]=1-2.2; P=0.047), whereas patients with ≥3 mutual gene-level alterations had an HR of death 2.38 (95% CI=1.47-3.87; P=0.0005). Together, our results show that gene-level concordance between tissue DNA and ctDNA analysis is prevalent and is an independent factor predicting significantly shorter patient survival.


Assuntos
DNA Tumoral Circulante , Neoplasias , Humanos , DNA Tumoral Circulante/genética , Biomarcadores Tumorais/genética , Neoplasias/patologia , DNA de Neoplasias/genética , Mutação/genética , Oncogenes
7.
Int J Radiat Oncol Biol Phys ; 116(3): 544-550, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586493

RESUMO

PURPOSE: Keratinocyte carcinomas are amenable to many treatments, including radiation therapy (RT). Electronic skin surface brachytherapy (ESSB) enables the precise delivery of radiation without radioisotopes. In this prospective multicenter clinical trial, we characterized early outcomes of ESSB prospectively through both patient- and clinician-reported measures. To corroborate the cosmesis observations, we also assessed patient-reported quality of life (QoL) and adverse events. METHODS AND MATERIALS: Patients ≥60 years old with stage T1N0M0 keratinocyte carcinoma were treated with ESSB. At 2-, 6-, and 12-weeks post-treatment, cosmesis from ESSB was assessed by both the patient and a clinician study investigator as either "good," "fair," or "bad." The Skindex-16 and the Skin Cancer Index (SCI) were used to assess patient QoL before and after treatment. Adverse events were assessed using the Common Toxicity Criteria for Adverse Events, version 4.0. RESULTS: Cosmesis and QoL were collected at 97% (99/102) of possible patient follow-up times. By 12 weeks post-treatment, 93.9% (31/33) of patient-reported and 96.9% (31/32) of clinician-reported cosmesis outcomes were "good." Compared with baseline, total Skindex-16 score significantly deteriorated at 2 weeks post-treatment (10.5 vs 24.5, P <.001), but significantly improved at 6 weeks (10.5 vs 4.7, P = .014) and 12 weeks (10.5 vs 2.1, P = .001) post-treatment. The total SCI score significantly improved from baseline to 6 weeks (78.4 vs 89.0, P = .001) post-treatment. The most frequent adverse events were radiation dermatitis, skin pain, and pruritus. All adverse events resolved to Grade ≤1 by 12 weeks post-treatment. CONCLUSIONS: This prospective, multicenter study demonstrated that ESSB is associated with a high rate of "good" early patient-reported cosmesis and increasing QoL and satisfaction with time. Validated assessments demonstrated a significant improvement in quality of life and resolution of moderate early adverse events by 6 to 12 weeks after treatment and corroborate the observation of favorable cosmesis.


Assuntos
Braquiterapia , Neoplasias da Mama , Carcinoma , Neoplasias Cutâneas , Humanos , Pessoa de Meia-Idade , Feminino , Qualidade de Vida , Estudos Prospectivos , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Neoplasias Cutâneas/radioterapia , Neoplasias da Mama/etiologia
8.
Cancer Res ; 83(1): 74-88, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-36264175

RESUMO

Driver mutations endow tumors with selective advantages and produce an array of pathogenic effects. Determining the function of somatic variants is important for understanding cancer biology and identifying optimal therapies. Here, we compiled a shared dataset from several cancer genomic databases. Two measures were applied to 535 cancer genes based on observed and expected frequencies of driver variants as derived from cancer-specific rates of somatic mutagenesis. The first measure comprised a binary classifier based on a binomial test; the second was tumor variant amplitude (TVA), a continuous measure representing the selective advantage of individual variants. TVA outperformed all other computational tools in terms of its correlation with experimentally derived functional scores of cancer mutations. TVA also highly correlated with drug response, overall survival, and other clinical implications in relevant cancer genes. This study demonstrates how a selective advantage measure based on a large cancer dataset significantly impacts our understanding of the spectral effect of driver variants in cancer. The impact of this information will increase as cancer treatment becomes more precise and personalized to tumor-specific mutations. SIGNIFICANCE: A new selective advantage estimation assists in oncogenic driver identification and relative effect measurements, enabling better prognostication, therapy selection, and prioritization.


Assuntos
Biologia Computacional , Neoplasias , Humanos , Mutação , Neoplasias/genética , Oncogenes
11.
J Neurooncol ; 159(3): 609-618, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35896906

RESUMO

BACKGROUND: Salvage of recurrent previously irradiated brain metastases (rBrM) is a significant challenge. Resection without adjuvant re-irradiation is associated with a high local failure rate, while reirradiation only partially reduces failure but is associated with greater radiation necrosis risk. Salvage resection plus Cs131 brachytherapy may offer dosimetric and biologic advantages including improved local control versus observation, with reduced normal brain dose versus re-irradiation, however data are limited. METHODS: A prospective registry of consecutive patients with post-stereotactic radiosurgery (SRS) rBrM undergoing resection plus implantation of collagen-matrix embedded Cs131 seeds (GammaTile, GT Medical Technologies) prescribed to 60 Gy at 5 mm from the cavity was analyzed. RESULTS: Twenty patients underwent 24 operations with Cs131 implantation in 25 tumor cavities. Median maximum preoperative diameter was 3.0 cm (range 1.1-6.3). Gross- or near-total resection was achieved in 80% of lesions. A median of 16 Cs131 seeds (range 6-30), with a median air-kerma strength of 3.5 U/seed were implanted. There was one postoperative wound dehiscence. With median follow-up of 1.6 years for survivors, two tumors recurred (one in-field, one marginal) resulting in 8.4% 1-year progression incidence (95%CI = 0.0-19.9). Radiographic seed settling was identified in 7/25 cavities (28%) 1.9-11.7 months post-implantation, with 1 case of distant migration (4%), without clinical sequelae. There were 8 cases of radiation necrosis, of which 4 were symptomatic. CONCLUSIONS: With > 1.5 years of follow-up, intraoperative brachytherapy with commercially available Cs131 implants was associated with favorable local control and toxicity profiles. Weak correlation between preoperative tumor geometry and implanted tiles highlights a need to optimize planning criteria.


Assuntos
Produtos Biológicos , Braquiterapia , Neoplasias Encefálicas , Lesões por Radiação , Radiocirurgia , Braquiterapia/métodos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Radioisótopos de Césio , Colágeno , Humanos , Necrose , Recidiva Local de Neoplasia/complicações , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
12.
Med Phys ; 49(8): e983-e1023, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35662032

RESUMO

The task group (TG) on magnetic resonance imaging (MRI) implementation in high-dose-rate (HDR) brachytherapy (BT)-Considerations from simulation to treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR BT workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT-related TG reports, and new image-guided recommendations beyond CT-based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA, an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Estados Unidos
13.
Brief Bioinform ; 23(2)2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35043155

RESUMO

Correctly identifying the true driver mutations in a patient's tumor is a major challenge in precision oncology. Most efforts address frequent mutations, leaving medium- and low-frequency variants mostly unaddressed. For TP53, this identification is crucial for both somatic and germline mutations, with the latter associated with the Li-Fraumeni syndrome (LFS), a multiorgan cancer predisposition. We present TP53_PROF (prediction of functionality), a gene specific machine learning model to predict the functional consequences of every possible missense mutation in TP53, integrating human cell- and yeast-based functional assays scores along with computational scores. Variants were labeled for the training set using well-defined criteria of prevalence in four cancer genomics databases. The model's predictions provided accuracy of 96.5%. They were validated experimentally, and were compared to population data, LFS datasets, ClinVar annotations and to TCGA survival data. Very high accuracy was shown through all methods of validation. TP53_PROF allows accurate classification of TP53 missense mutations applicable for clinical practice. Our gene specific approach integrated machine learning, highly reliable features and biological knowledge, to create an unprecedented, thoroughly validated and clinically oriented classification model. This approach currently addresses TP53 mutations and will be applied in the future to other important cancer genes.


Assuntos
Síndrome de Li-Fraumeni , Mutação de Sentido Incorreto , Predisposição Genética para Doença , Humanos , Síndrome de Li-Fraumeni/genética , Aprendizado de Máquina , Medicina de Precisão , Proteína Supressora de Tumor p53/genética
14.
Brachytherapy ; 21(1): 120-127, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34706854

RESUMO

PURPOSE: This is a multi-institutional report on inter-observer and inter-instrument variation in the calibration of the absorbed dose rate for a planar 32P beta emitting brachytherapy source. Measurement accuracy is essential since the dose profile is steep and the source is used for the treatment of tumors that are located in close proximity to healthy nervous system structures. METHODS AND MATERIALS: An RIC-100 32P source was calibrated by three institutions using their own equipment and following their standard procedures. The first institution calibrated the source with an electron diode and EBT3 film. The second institution used an electron diode. The third institution used HD810 film. Additionally, each institution was asked to calibrate the source using an electron diode and procedure that was shared among all institutions and shipped along with the radiation source. The dose rate was reported in units of cGy*min-1 at a water equivalent depth of 1 mm. RESULTS: Close agreement was observed in the measurements from different users and equipment. The variation across all diode detectors and institutions had a standard deviation of 1.8% and maximum difference of 4.6%. The observed variation among two different diode systems used within the same institution had a mean difference of 1.6% and a maximum variation of 1.8%. The variations among film and diode systems used within the same institution had a mean difference of 2.9% and a maximum variation of 4.3% CONCLUSIONS: The absorbed dose rate measurement protocol of the planar beta-emitting 32P source permits consistent dosimetry across three institutions and five different electron diode and radiochromic film systems. The methodologies presented herein should enable measurement consistency among other clinical users, which will help ensure high quality patient treatments and outcomes analysis.


Assuntos
Braquiterapia , Braquiterapia/métodos , Calibragem , Dosimetria Fotográfica , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Água
15.
J Am Acad Dermatol ; 84(6): 1575-1584, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32827607

RESUMO

BACKGROUND: Radiation therapy (RT) is a treatment option for select skin cancers. The histologic effects of RT on normal skin or skin cancers are not well characterized. Dermoscopy, high-frequency ultrasonography (HFUS), and reflectance confocal microscopy (RCM) are noninvasive imaging modalities that may help characterize RT response. OBJECTIVES: To describe changes in the tumor and surrounding skin of patients with basal cell carcinoma (BCC) treated with RT. METHODS: The study was conducted between 2014 and 2018. Patients with biopsy-proven BCCs were treated with 42 Gy in 6 fractions using a commercially available brachytherapy device. Dermoscopy, HFUS, and RCM were performed before treatment and at 6 weeks, 3 months, and 12 months after RT. RESULTS: A total of 137 imaging assessments (RCM + dermoscopy + HFUS) were performed in 12 patients. BCC-specific features were present in 81.8%, 91%, and 17% of patients imaged with dermoscopy, RCM, and HFUS at baseline, respectively, before treatment. After treatment, the resolution of these features was noted in 33.4%, 91.7%, and 100% of patients imaged with the respective modalities. No recurrences were seen after a mean of 31.7 months of follow-up. LIMITATIONS: Small sample size and no histopathologic correlation. CONCLUSION: Dermoscopy and HFUS were not as reliable as RCM at characterizing BCC RT response.


Assuntos
Carcinoma Basocelular/radioterapia , Fracionamento da Dose de Radiação , Recidiva Local de Neoplasia/diagnóstico , Neoplasias Cutâneas/radioterapia , Pele/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma Basocelular/diagnóstico , Dermoscopia/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Microscopia Confocal/estatística & dados numéricos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/prevenção & controle , Estudos Prospectivos , Reprodutibilidade dos Testes , Pele/efeitos da radiação , Neoplasias Cutâneas/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia/estatística & dados numéricos
16.
Brachytherapy ; 19(6): 762-766, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32952055

RESUMO

PURPOSE: Safe delivery of brachytherapy and establishing a safety culture are critical in high-quality brachytherapy. The American Brachytherapy Society (ABS) Quality and Safety Committee surveyed members regarding brachytherapy services offered, safety practices during treatment, quality assurance procedures, and needs to develop safety and training materials. METHODS AND MATERIALS: A 22-item survey was sent to ABS membership in early 2019 to physicians, physicists, therapists, nurses, and administrators. Participation was voluntary. Responses were summarized with descriptive statistics and relative frequency distributions. RESULTS: There were 103 unique responses. Approximately one in three was attending physicians and one in three attending physicists. Most were in practice >10 years. A total of 94% and 50% performed gynecologic and prostate brachytherapy, respectively. Ninety-one percent performed two-identification patient verification before treatment. Eighty-six percent performed a time-out. Ninety-five percent had an incident reporting or learning system, but only 71% regularly reviewed incidents. Half reviewed safety practices within the last year. Twenty percent reported they were somewhat or not satisfied with department safety culture, but 92% of respondents were interested in improving safety culture. Most reported time, communication, and staffing as barriers to improving safety. Most respondents desired safety-oriented webinars, self-assessment modules, learning modules, or checklists endorsed by the ABS to improve safety practice. CONCLUSIONS: Most but not all practices use standards and quality assurance procedures in line with society recommendations. There is a need to heighten safety culture at many departments and to shift resources (e.g., time or staffing) to improve safety practice. There is a desire for society guidance to improve brachytherapy safety practices. This is the first survey to assess safety practice patterns among a national sample of radiation oncologists with expertise in brachytherapy.


Assuntos
Braquiterapia/estatística & dados numéricos , Neoplasias dos Genitais Femininos/radioterapia , Segurança do Paciente , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Radioterapia (Especialidade)/organização & administração , Braquiterapia/efeitos adversos , Braquiterapia/normas , Lista de Checagem , Comunicação , Feminino , Humanos , Masculino , Cultura Organizacional , Sistemas de Identificação de Pacientes/estatística & dados numéricos , Admissão e Escalonamento de Pessoal , Melhoria de Qualidade , Gestão de Riscos/estatística & dados numéricos , Inquéritos e Questionários , Fatores de Tempo
17.
Brachytherapy ; 19(4): 415-426, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32409128

RESUMO

PURPOSE: Keratinocyte carcinoma (KC, previously nonmelanoma skin cancer) represents the most common cancer worldwide. While surgical treatment is commonly utilized, various radiation therapy techniques are available including external beam and brachytherapy. As such, the American Brachytherapy Society has created an updated consensus statement regarding the use of brachytherapy in the treatment of KCs. METHODS: Physicians and physicists with expertise in skin cancer and brachytherapy created a consensus statement for appropriate patient selection, data, dosimetry, and utilization of skin brachytherapy and techniques based on a literature search and clinical experience. RESULTS: Guidelines for patient selection, evaluation, and dose/fractionation schedules to optimize outcomes for patients with KC undergoing brachytherapy are presented. Studies of electronic brachytherapy are emerging, although limited long-term data or comparative data are available. Radionuclide-based brachytherapy represents an appropriate option for patients with small KCs with multiple techniques available. CONCLUSIONS: Skin brachytherapy represents a standard of care option for appropriately selected patients with KC. Radionuclide-based brachytherapy represents a well-established technique; however, the current recommendation is that electronic brachytherapy be used for KC on prospective clinical trial or registry because of a paucity of mature data.


Assuntos
Braquiterapia/normas , Carcinoma Basocelular/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Cutâneas/radioterapia , Braquiterapia/métodos , Consenso , Fracionamento da Dose de Radiação , Humanos , Seleção de Pacientes , Radioisótopos/uso terapêutico , Estados Unidos
18.
Brachytherapy ; 18(3): 277-284, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30803923

RESUMO

BACKGROUND: Intraoperative radiotherapy (IORT) is an effective strategy for the delivery of high doses of radiotherapy to a residual tumor or resection cavity with relative sparing of nearby healthy tissues. This strategy is an important component of the multimodality management of pediatric soft tissue sarcomas, particularly in cases where patients have received prior courses of external beam radiotherapy. PURPOSE: Tumor beds with significant topographic irregularity remain a therapeutic challenge because existing IORT technologies are typically most reliable with flat surfaces. To address this limitation, we have developed a novel strategy to create custom, prefabricated high-dose-rate (HDR)-IORT applicators designed to match the shape of an anticipated surgical cavity. METHODS AND MATERIALS: Silastic applicators are constructed using three-dimensional (3D) printing and are derived from volumetric segmentation of preoperative imaging. RESULTS: HDR preplanning with the applicators improves dosimetric accuracy and minimizes incremental operative time. In this report, we describe the fabrication process for the 3D-printed applicators and detail our experience utilizing this strategy in two pediatric patients who underwent HDR-IORT as part of complex base of skull sarcoma resections. CONCLUSIONS: Early experience suggests that usage of the custom applicators is feasible, versatile for a variety of clinical situations, and enables the uniform delivery of high superficial doses of radiotherapy to irregularly shaped surgical cavities.


Assuntos
Braquiterapia/instrumentação , Desenho de Equipamento , Neoplasias/terapia , Braquiterapia/métodos , Criança , Feminino , Humanos , Período Intraoperatório , Masculino , Neoplasia Residual , Impressão Tridimensional , Planejamento da Radioterapia Assistida por Computador , Radioterapia Adjuvante
19.
Brachytherapy ; 18(3): 292-298, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30497939

RESUMO

PURPOSE: Brachytherapy is utilized in the treatment of many different malignancies; although traditionally performed with low-dose-rate or high-dose-rate techniques, more recently, electronic brachytherapy (EB) has emerged as a potential alternative. At this time, there are no evidence-based guidelines to assist clinicians in patient selection for EB and concerns exits regarding differences in dosimetry as compared to traditional brachytherapy techniques. As such, the American Brachytherapy Society appointed a group of physicians and physicists to create a consensus statement regarding the use of EB. METHODS AND MATERIALS: Physicians and physicists with expertise in brachytherapy created a site-directed consensus statement for appropriate patient selection and utilization of EB based on a literature search and clinical experience. RESULTS: EB has been utilized to deliver accelerated partial breast irradiation with, thus far acceptable local control and toxicity rates including a randomized trial that used EB to deliver intraoperative radiotherapy; however, prospective data with large patient numbers and long-term follow up are needed. Increasing numbers of patients have been treated with EB for nonmelanomatous skin cancers; although, preliminary data are promising, there is a lack of data comparing EB to traditional radiotherapy techniques as well as a lack of long-term follow up. For treatment of the vaginal cuff with EB, small retrospective studies have been reported without long-term follow up. CONCLUSIONS: In light of a randomized trial in breast showing higher rates of recurrence and the lack of prospective data with mature follow up with other sites, as well as concerns regarding dosimetry, it is not recommended that EB be utilized for accelerated partial breast irradiation, nonmelanomatous skin cancers, or vaginal cuff brachytherapy outside prospective clinical trials at this time.


Assuntos
Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Neoplasias dos Genitais Femininos/radioterapia , Seleção de Pacientes , Neoplasias Cutâneas/radioterapia , Braquiterapia/efeitos adversos , Consenso , Eletrônica , Feminino , Humanos , Dosagem Radioterapêutica , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Am J Case Rep ; 19: 534-539, 2018 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-29731507

RESUMO

BACKGROUND There is now evidence to support that some cases of high-grade serous papillary carcinoma arise from the fallopian tubes rather than the ovaries. Common symptoms at presentation include abdominal pain and swelling, vomiting, altered bowel habit and urinary symptoms. To our knowledge, this is the first case of serous papillary carcinoma presenting as a vaginal mass lesion. CASE REPORT A 41-year-old woman was referred to the Bnai-Zion Medical Center with the main complaint of irregular vaginal bleeding, vaginal mucous discharge, and suspected pelvic mass. Physical examination showed a soft, painless mass, measuring about 10 cm in diameter located mainly in the recto-vaginal septum, but not involving the uterus. Ultrasound examination showed no abnormal ovarian or uterine findings. Transvaginal biopsies of the mass showed a poorly differentiated serous papillary carcinoma of ovarian, tubal, or peritoneal origin. The physical examination and imaging findings strongly indicated an inoperable tumor, and the patient was treated with neoadjuvant (pre-surgical) chemotherapy. Pre-operative computed tomography (CT) imaging showed the partial involvement of the colon, and so surgical treatment included total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy, partial vaginectomy, anterior rectal resection, and lymph node dissection. Histopathology of the surgical specimens showed a poorly differentiated serous carcinoma originating from the fimbria of the right fallopian tube. CONCLUSIONS To the best of our knowledge, this is the first report to describe primary fallopian tube papillary serous carcinoma presenting as a vaginal mass. Therefore, physicians should be aware of this possible diagnosis.


Assuntos
Cistadenocarcinoma Papilar/patologia , Cistadenocarcinoma Seroso/patologia , Tubas Uterinas/patologia , Neoplasias dos Genitais Femininos/patologia , Adulto , Cistadenocarcinoma Papilar/terapia , Cistadenocarcinoma Seroso/terapia , Tubas Uterinas/cirurgia , Feminino , Neoplasias dos Genitais Femininos/terapia , Humanos , Hemorragia Uterina/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA