1.
J Knee Surg ; 37(8): 556-569, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38513696

RESUMO

The knee joint plays a pivotal role in mobility and stability during ambulatory and standing activities of daily living (ADL). Increased incidence of knee joint pathologies and resulting surgeries has led to a growing need to understand the kinematics and kinetics of the knee. In vivo, in silico, and in vitro testing domains provide researchers different avenues to explore the effects of surgical interactions on the knee. Recent hardware and software advancements have increased the flexibility of in vitro testing, opening further opportunities to answer clinical questions. This paper describes best practices for conducting in vitro knee biomechanical testing by providing guidelines for future research. Prior to beginning an in vitro knee study, the clinical question must be identified by the research and clinical teams to determine if in vitro testing is necessary to answer the question and serve as the gold standard for problem resolution. After determining the clinical question, a series of questions (What surgical or experimental conditions should be varied to answer the clinical question, what measurements are needed for each surgical or experimental condition, what loading conditions will generate the desired measurements, and do the loading conditions require muscle actuation?) must be discussed to help dictate the type of hardware and software necessary to adequately answer the clinical question. Hardware (type of robot, load cell, actuators, fixtures, motion capture, ancillary sensors) and software (type of coordinate systems used for kinematics and kinetics, type of control) can then be acquired to create a testing system tailored to the desired testing conditions. Study design and verification steps should be decided upon prior to testing to maintain the accuracy of the collected data. Collected data should be reported with any supplementary metrics (RMS error, dynamic statistics) that help illuminate the reported results. An example study comparing two different anterior cruciate ligament reconstruction techniques is provided to demonstrate the application of these guidelines. Adoption of these guidelines may allow for better interlaboratory result comparison to improve clinical outcomes.


Assuntos
Articulação do Joelho , Humanos , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Fenômenos Biomecânicos , Robótica , Técnicas In Vitro , Amplitude de Movimento Articular
2.
Artigo em Inglês | MEDLINE | ID: mdl-38154501

RESUMO

OBJECTIVES: Bicuspid aortic valve (BAV) aortopathy is defined by 3 phenotypes-root, ascending, and diffuse-based on region of maximal aortic dilation. We sought to determine the association between aortic mechanical behavior and aortopathy phenotype versus other clinical variables. METHODS: From August 1, 2016, to March 1, 2023, 375 aortic specimens were collected from 105 patients undergoing elective ascending aortic aneurysm repair for BAV aortopathy. Planar biaxial data (191 specimens) informed constitutive descriptors of the arterial wall that were combined with in vivo geometry and hemodynamics to predict stiffness, stress, and energy density under physiologic loads. Uniaxial testing (184 specimens) evaluated failure stretch and failure Cauchy stress. Boosting regression was implemented to model the association between clinical variables and mechanical metrics. RESULTS: There were no significant differences in mechanical metrics between the root phenotype (N = 33, 31%) and ascending/diffuse phenotypes (N = 72, 69%). Biaxial testing demonstrated older age was associated with increased circumferential stiffness, decreased stress, and decreased energy density. On uniaxial testing, longitudinally versus circumferentially oriented specimens failed at significantly lower Cauchy stress (50th [15th, 85th percentiles]: 1.0 [0.7, 1.6] MPa vs 1.9 [1.3, 3.1] MPa; P < .001). Age was associated with decreased failure stretch and stress. Elongated ascending aortas were also associated with decreased failure stress. CONCLUSIONS: Aortic mechanical function under physiologic and failure conditions in BAV aortopathy is robustly associated with age and poorly associated with aortopathy phenotype. Data suggesting that the root phenotype of BAV aortopathy portends worse outcomes are unlikely to be related to aberrant, phenotype-specific tissue mechanics.

3.
Artigo em Inglês | MEDLINE | ID: mdl-37716653

RESUMO

OBJECTIVES: We evaluate the independent effects of patient and aortic tissue characteristics on biaxial physiologic mechanical metrics in aneurysmal and nonaneurysmal tissues, and uniaxial failure metrics in aneurysmal tissue, comparing longitudinal and circumferential behavior. METHODS: From February 2017 to October 2022, 382 aortic specimens were collected from 134 patients; 268 specimens underwent biaxial testing, and 114 specimens underwent uniaxial testing. Biaxial testing evaluated Green-Lagrange transition strain and low and high tangent moduli. Uniaxial testing evaluated failure stretch, Cauchy stress, and low and high tangent moduli. Longitudinal gradient boosting models were implemented to estimate mechanical metrics and covariates of importance. RESULTS: On biaxial testing, nonaneurysmal tissue was less deformable and exhibited a lower transition strain than aneurysmal tissue in the longitudinal (0.18 vs 0.30, P < .001) and circumferential (0.25 vs 0.30, P = .01) directions. Older age and increasing ascending aortic length contributed most to predicting transition strain. On uniaxial testing, longitudinal specimens failed at lower stretch (1.4 vs 1.5, P = .003) and Cauchy stress (1.0 vs 1.9 kPa, P < .001) than circumferential specimens. Failure stretch and Cauchy stress were most strongly associated with tissue orientation and decreased sharply with older age. Age, ascending aortic length, and tissue thickness were the most frequent covariates predicting mechanical metrics across 10 prediction models. CONCLUSIONS: Age was the strongest predictor of mechanical behavior. After adjusting for age, nonaneurysmal tissue was less deformable than aneurysmal tissue. Differences in longitudinal and circumferential mechanics contribute to tissue dysfunction and failure in ascending aneurysms. This highlights the need to better understand the effects of age, ascending aortic length, and thickness on clinical aortic behavior.

4.
J Thorac Cardiovasc Surg ; 166(3): 701-712.e7, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35219518

RESUMO

OBJECTIVES: We hypothesized that tissue characteristics vary significantly along zone zero, which may be reflected by regional differences in stored elastic energy. Our objectives were to (1) characterize the regional variation in stored elastic energy within tissues of the aortic zone zero and (2) identify the association between this variation and patient characteristics. METHODS: From February 2018 to January 2021, 123 aortic tissue samples were obtained from the aortic root and proximal and distal ascending aortas of 65 adults undergoing elective ascending aorta replacement. Biaxial biomechanics testing was performed to obtain tissue elastic energy at the inflection point and compared with patient demographics and preoperative computed tomography imaging. Coefficient models were fit using B-spline to interrogate the relationship among elastic energy, region, and patient characteristics. RESULTS: Mean elastic energy at inflection point was 24.3 ± 15.6 kJ/m3. Elastic energy increased significantly between the root and proximal, and root and distal ascending aorta and decreased with increasing age. Differences due to history of connective tissue disorder and bicuspid aortic valve were significant but diminished when controlled for other patient characteristics. Among covariates, age and region were found to be the most important predictors for elastic energy. CONCLUSIONS: Aortic tissue biomechanical metrics varied across regions and with patient characteristics within the aortic zone zero. Assessment of endovascular outcomes in the ascending aorta must closely consider the region of deployment and variable tissue qualities along the length of the landing zone. Regional variation in tissue characteristics should be incorporated into existing patient-specific models of aortic mechanics.


Assuntos
Aorta , Doença da Válvula Aórtica Bicúspide , Adulto , Humanos , Fenômenos Biomecânicos , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
5.
Artigo em Inglês | MEDLINE | ID: mdl-36528437

RESUMO

OBJECTIVES: There is growing consensus that aortic diameter is a flawed predictor of aortic dissection risk. We hypothesized that aortic tissue metrics would be better predicted by clinical metrics other than aortic diameter. Our objectives were to (1) characterize circumferential aortic failure stress and stretch as a result of aortic size and patient demographics, and (2) identify the influence of bicuspid aortic valve on failure metrics. METHODS: From February 2018 to January 2021, 136 aortic tissue samples were obtained from 86 adults undergoing elective ascending aorta repair. Uniaxial biomechanical testing to failure, defined as a full-thickness central tear, was performed to obtain tissue failure stress and failure stretch and compared with clinical data and preoperative computed tomography imaging. The relationships among aortic diameter, patient demographics, and failure metrics were assessed using random forest regression models. RESULTS: Median failure stress was 1.46 (1.02-1.94) megapascals, and failure stretch was 1.36 (1.27-1.54). Regression models correlated moderately with failure stress (R2 = 0.557) and highly with failure stretch (R2 = 0.806). Failure stress decreased with increasing age, lower body mass index, thicker tissue, and tricuspid aortic valves, whereas failure stretch was most highly correlated with age. Aortic area-to-height index outperformed aortic diameter in all models. CONCLUSIONS: Aneurysmal ascending aortic tissue failure metrics correlated with available clinical metrics. Greater tissue thickness, older age, and tricuspid aortic valve morphology outperformed aortic diameter, warranting further investigation into the role of a patient-specific multifactorial dissection risk assessment over aortic diameter as a sole marker of aortic tissue integrity.

6.
Sci Data ; 7(1): 20, 2020 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-31941894

RESUMO

The skin, fat, and muscle of the musculoskeletal system provide essential support and protection to the human body. The interaction between individual layers and their composite structure dictate the body's response during mechanical loading of extremity surfaces. Quantifying such interactions may improve surgical outcomes by enhancing surgical simulations with lifelike tissue characteristics. Recently, a comprehensive tissue thickness and anthropometric database of in vivo extremities was acquired using a load sensing instrumented ultrasound to enhance the fidelity of advancing surgical simulations. However detailed anatomy of tissue layers of musculoskeletal extremities was not captured. This study aims to supplement that database with an enhanced dataset of in vitro specimens that includes ultrasound imaging supported by motion tracking of the ultrasound probe and two additional full field imaging modalities (magnetic resonance and computed tomography). The additional imaging datasets can be used in conjunction with the ultrasound/force data for more comprehensive modeling of soft tissue mechanics. Researchers can also use the image modalities in isolation if anatomy of legs and arms is needed.


Assuntos
Antropometria , Sistema Musculoesquelético/anatomia & histologia , Sistema Musculoesquelético/diagnóstico por imagem , Fenômenos Biomecânicos , Simulação por Computador , Extremidades/anatomia & histologia , Extremidades/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Procedimentos Cirúrgicos Operatórios , Tomografia Computadorizada por Raios X , Ultrassonografia
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 933-936, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30440543

RESUMO

The characterization of soft tissue interaction with surgical tools is critical for authentic surgical simulations and accurate robotic-assisted surgery. Virtual and augmented reality are often used to simulate surgical procedures with haptic feedback to increase the sense of reality. Haptic simulations require models with parameters based on real tissue data. The accuracy of haptic feedback can be increased when the mechanics of the interaction between tool and tissue is better understood. Several foundational surgical tools were instrumented to acquire such data for a variety of applications. Presented here are a set of modular tools and software built to expand the scope of surgical procedures for which comprehensive training data for surgical simulators are desired. In a demonstration, the system measured loads in 6 degrees-of-freedom and position and orientation in relation to a cadaver leg. Additionally, the tools were designed with modularity to accommodate adaptation for additional tools not used in this study.


Assuntos
Retroalimentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Equipamentos Cirúrgicos , Simulação por Computador , Humanos , Treinamento por Simulação , Software , Interface Usuário-Computador
8.
J Shoulder Elbow Surg ; 27(11): 2068-2076, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30076036

RESUMO

BACKGROUND: Recent anatomic and clinical studies have shown that the location of the injury to the elbow ulnar collateral ligament (UCL) is an important variable in deciding on surgical intervention; however, no studies have evaluated these findings biomechanically. METHODS: This study tested 16 intact elbow specimens. Valgus torques of 2.5 and 5 Nm were applied to the elbow at various flexion angles, and the resulting valgus angles were measured. The valgus angles were applied to the elbows in their intact states and again after partial and complete cuts were made on the proximal and distal insertions of the UCL. Resulting valgus torques were measured, and stiffness was calculated for each elbow flexion angle. Unpaired t tests were used to evaluate the effects of cut location and flexion angle on joint rotational stability and stiffness. RESULTS: The posterior-distal insertion contributed the most to stability. At valgus angles generated from 2.5 Nm intact torques, the posterior-distal insertions contributed to 51% ± 26% (P < .03) intact rotational stability, and at valgus angles generated from 5 Nm intact torques, the posterior-distal insertions contributed to 41% ± 17% (P < .02) intact rotational stability. For overall stiffness, the posterior-distal insertions contributed to 31% ± 12% (P < .045) intact stiffness. CONCLUSION: Overall, the posterior distal insertion of the UCL contributed most to rotational stability and stiffness of the medial elbow when subjected to valgus stress at 90° and 120° of elbow flexion. At higher elbow flexion angles, the posterior insertions contributed more to stability, whereas the anterior insertions had a greater effect at lower flexion angles.


Assuntos
Ligamento Colateral Ulnar/lesões , Articulação do Cotovelo , Instabilidade Articular/etiologia , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Torque , Suporte de Carga
9.
J Neurosurg ; 127(4): 829-836, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27739941

RESUMO

OBJECTIVE The far lateral transcondylar approach to the ventral foramen magnum requires partial resection of the occipital condyle. Early biomechanical studies suggest that occipitocervical (OC) fusion should be considered if 50% of the condyle is resected. In clinical practice, however, a joint-sparing condylectomy has often been employed without the need for OC fusion. The biomechanics of the joint-sparing technique have not been reported. Authors of the present study hypothesized that the clinically relevant joint-sparing condylectomy would result in added stability of the craniovertebral junction as compared with earlier reports. METHODS Multidirectional in vitro flexibility tests were performed using a robotic spine-testing system on 7 fresh cadaveric spines to assess the effect of sequential unilateral joint-sparing condylectomy (25%, 50%, 75%, 100%) in comparison with the intact state by using cardinal direction and coupled moments combined with a simulated head weight "follower load." RESULTS The percent change in range of motion following sequential condylectomy as compared with the intact state was 5.2%, 8.1%, 12.0%, and 27.5% in flexion-extension (FE); 8.4%, 14.7%, 39.1%, and 80.2% in lateral bending (LB); and 24.4%, 31.5%, 49.9%, and 141.1% in axial rotation (AR). Only values at 100% condylectomy were statistically significant (p < 0.05). With coupled motions, however, -3.9%, 6.6%, 35.8%, and 142.4% increases in AR+F and 27.3%, 32.7%, 77.5%, and 175.5% increases in AR+E were found. Values for 75% and 100% condyle resection were statistically significant in AR+E. CONCLUSIONS When tested in the traditional cardinal directions, a 50% joint-sparing condylectomy did not significantly increase motion. However, removing 75% of the condyle may necessitate fusion, as a statistically significant increase in motion was found when E was coupled with AR. Clinical correlation is ultimately needed to determine the need for OC fusion.


Assuntos
Articulação Atlantoccipital/fisiologia , Osso Occipital/cirurgia , Osteotomia/métodos , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Cadáver , Humanos , Tratamentos com Preservação do Órgão , Período Pós-Operatório
10.
Orthopedics ; 38(1): 9-16, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25611406

RESUMO

The goal of this study was to determine whether single-tunnel-double-bundle-equivalent posterior cruciate ligament (PCL) reconstruction using an aperture femoral fixation device better replicated normal knee kinematics than single-bundle reconstruction. Eight fresh-frozen human cadaver knees underwent arthroscopically assisted PCL reconstruction and were examined with a robotic testing system to assess knee joint kinematics under combinations of applied internal, neutral, and external rotational tibial torque and anteroposterior translational forces at 0°, 30°, 60°, 90°, and 120° flexion. Three conditions were tested: (1) intact PCL; (2) single-tunnel PCL reconstruction with anterolateral and posteromedial bundle fixation at 90°/90° (single bundle); and (3) 90°/0° (double-bundle equivalent), respectively. Posterior tibial translation was the primary outcome measure. Compared with the intact knee, double-bundle-equivalent reconstruction under external tibial torque allowed greater posterior translation across the flexion arc as a whole (P=.025) and at 30° flexion (P=.027) when results were stratified by flexion angle. No other kinematic differences were found with single-bundle or double-bundle-equivalent fixation, including mediolateral translation and both coupled and isolated tibial rotation (P>.05). Single-bundle PCL reconstruction closely approximated native knee rotational and translational kinematics, whereas double-bundle-equivalent reconstruction permitted increased posterior translation with applied external tibial torque, particularly at lower flexion angles. Single-bundle PCL reconstruction provides knee stability similar to the intact condition, making it a practical alternative to conventional double-bundle PCL reconstruction. The authors found that double-bundle-equivalent reconstruction provided no advantage to justify its clinical use.


Assuntos
Fêmur/cirurgia , Traumatismos do Joelho/cirurgia , Procedimentos Ortopédicos/métodos , Procedimentos de Cirurgia Plástica/métodos , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular/fisiologia , Adulto , Idoso , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Traumatismos do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/fisiopatologia , Rotação , Torque
11.
Arthroscopy ; 30(11): 1430-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25241294

RESUMO

PURPOSE: To determine the effect of debriding the indirect insertion component of the femoral anterior cruciate ligament (ACL) attachment on tibiofemoral kinematics when compared with the intact knee. METHODS: Knee kinematics were measured in 9 cadaveric knees with the ACL intact, after indirect insertion debridement, and after ACL transection. Three loading conditions were used: (1) a 134-N anterior tibial load, (2) a combined 10-Nm valgus and 5-Nm internal tibial torque, and (3) a simulated robotic pivot shift. Anterior tibial translation (ATT) was recorded in response to anterior and combined loads at 0°, 15°, 30°, 45°, 60°, and 90° of flexion. Posterior tibial translation and external tibial rotation were recorded during the simulated pivot shift. RESULTS: With an anterior load, indirect insertion debridement increased ATT by 0.37 ± 0.24 mm at 0° (P = .002) and by 0.16 ± 0.19 mm at 15° (P = .033; increases <1 mm in all specimens). ACL transection increased ATT in response to an anterior load (P = .0001) with maximum effect at 15° compared with the intact and debrided states (11.26 ± 1.15 mm and 11.04 ± 1.08 mm, respectively). With a combined load, indirect insertion debridement increased ATT by 0.17 ± 0.11 mm at 0° (P = .001; increases <0.3 mm in all specimens) with no effect at other angles. ACL transection increased ATT in response to a combined load (P = .001) with maximum effect at 15° (4.45 ± 0.85 mm v ACL intact and 4.44 ± 0.84 mm v debrided indirect insertion). In the ACL intact condition, the pivot shift produced 1.29 ± 1.34 mm of posterior tibial translation and 1.54 ± 1.61° of external tibial rotation, as compared with 1.28 ± 1.34 mm and 1.54 ± 1.47°, respectively, after debridement (P = .68 and P = .99, respectively) and 12.79 ± 3.22 mm and 17.60 ± 4.30°, respectively, after ACL transection (P = .0001). CONCLUSIONS: The indirect femoral ACL insertion contributes minimally to restraint of tibial translation and rotation. CLINICAL RELEVANCE: Femoral tunnel positioning for anatomic ACL reconstruction should aim to recreate the biomechanically significant direct insertion.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/fisiologia , Ligamento Cruzado Anterior/cirurgia , Desbridamento/psicologia , Articulação do Joelho/fisiologia , Osteotomia/métodos , Fenômenos Biomecânicos , Cadáver , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Robótica , Rotação , Tíbia , Torque
12.
J Neurosurg Spine ; 18(6): 575-81, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23600582

RESUMO

OBJECT: This study compared the fixing strength and stability achieved by a unilateral plate and screw configuration against a standard cervical fixation plate using a single-level corpectomy and allograft strut graft model. METHODS: Multidirectional in vitro flexibility tests were performed using a robotic spine testing system. Human cadaveric spines were assessed for spinal stability after vertebral corpectomy and anterior instrumentation. Specimens were mounted cranially and caudally on custom jigs that were then attached to load cells on the robotic system's end effector and base pedestal. C2-T1 spine specimens (n = 6) were tested intact; then after C-5 corpectomy (the vertebral body was excised), allograft placement and anterior plate fixation were performed. The surgeons performed a uniform corpectomy and reconstruction of each specimen in a protocol fashion. Two plates were compared: a unilateral 4-hole cervical plate designed to obtain rigid fixation using 4 convergent fixation screws all placed unilateral to the vertebral midline, and a standard cervical plate with bilateral plate screw configuration. The plate testing sequence was selected at random to limit bias. Fixation screws were matched for length and diameter. Pure moments were applied under load control (maximum 1.8 Nm) in flexion, extension, left/right lateral bending, and left/right axial rotation. Vertebral motion was measured using an optoelectronic system. The mean relative range of motion between C-4 and C-6 was compared among groups using repeated-measures ANOVA (significance level of 0.05). RESULTS: In comparing the intact construct and 2 different plates in all planes of motion, only motion in extension (intact vs. unilateral plate, p = 0.003; intact vs. standard plate, p = 0.001) and left axial rotation (intact vs unilateral plate, p = 0.019) were significantly affected. In terms of immediate cervical stability after 1-level corpectomy and placement of an allograft reconstruction, the unilateral plate showed comparable stiffness to the standard plate in all 3 motion planes (flexion [p = 0.993], extension [p = 0.732], left lateral bending [p = 0.683], right lateral bending [p = 0.546], left axial rotation [p = 0.082], and right axial rotation [p = 0.489]). The unilateral plate showed a trend toward improved stiffness in axial rotation. In no direction did the unilateral configuration prove significantly less stiff than the traditional configuration. CONCLUSIONS: The unilateral plate design proposed here requires minimal dissection and retraction beyond the midline of tissues susceptible to scar, postoperative pain, and swelling. The authors' study suggests that a unilateral plate can be configured to provide comparable fixation strength and torsional stiffness compared with traditional, widely accepted plate designs.


Assuntos
Placas Ósseas/normas , Parafusos Ósseos/normas , Vértebras Cervicais/cirurgia , Procedimentos Ortopédicos/métodos , Amplitude de Movimento Articular/fisiologia , Robótica/métodos , Idoso , Vértebras Cervicais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/normas
13.
Spine J ; 13(5): 572-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23498926

RESUMO

BACKGROUND: Segmental fixation improves fusion rates and promotes patient mobility by controlling instability after lumbar surgery. Efforts to obtain stability using less invasive techniques have lead to the advent of new implants and constructs. A new interspinous fixation device (ISD) has been introduced as a minimally invasive method of stabilizing two adjacent interspinous processes by augmenting an interbody cage in transforaminal interbody fusion. The ISD is intended to replace the standard pedicle screw instrumentation used for posterior fixation. PURPOSE: The purpose of this study is to compare the rigidity of these implant systems when supplementing an interbody cage as used in transforaminal lumbar interbody fusion. STUDY DESIGN: An in vitro human cadaveric biomechanical study. METHODS: Seven human cadaver spines (T12 to the sacrum) were mounted in a custom-designed testing apparatus, for biomechanical testing using a multiaxial robotic system. A comparison of segmental stiffness was carried out among five conditions: intact spine control; interbody spacer (IBS), alone; interbody cage with ISD; IBS, ISD, and unilateral pedicle screws (unilat); and IBS, with bilateral pedicle screws (bilat). An industrial robot (KUKA, GmbH, Augsburg, Germany) applied a pure moment (±5 Nm) in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) through an anchor to the T12 vertebral body. The relative vertebral motion was captured using an optoelectronic camera system (Optotrak; Northern Digital, Inc., Waterloo, Ontario, Canada). The load sensor and the camera were synchronized. Maximum rotation was measured at each level and compared with the intact control. Implant constructs were compared with the control and with each other. A statistical analysis was performed using analysis of variance. RESULTS: A comparison between the intact spine and the IBS group showed no significant difference in the range of motion (ROM) in FE, LB, or AR for the operated level, L3-L4. After implantation of the ISD to augment the IBS, there was a significant decrease in the ROM of 74% in FE (p<.001) but no significant change in the ROM in LB and AR. The unilat construct significantly reduced the ROM by 77% compared with FE control (p<.001) and by 55% (p=.002) and 42% (p=.04) in LB and AR, respectively, compared with control. The bilat construct reduced the ROM in FE by 77% (p<.001), LB by 77% (p=.001), and AR by 65% (p=.001) when compared with the control spine. There was no statistically significant difference in the ROM in FE among the stand-alone ISD, unilat, and bilat constructs. However, in both LB and AR, the unilat and the bilat constructs were significantly stiffer (reduction in the ROM) than the ISD and the IBS combination. The ISD stability in LB and AR was not different from the intact control with no instrumentation at all. There was no statistical difference between the stability of the unilat and the bilat constructs in any direction. However, LB and AR in the unilat group produced a mean rotation of 3.83°±3.30° and 2.33°±1.33°, respectively, compared with the bilat construct that limited motion to 1.96°±1.46° and 1.39°±0.73°. There was a trend suggesting that the bilat construct was the most rigid construct. CONCLUSIONS: In FE, the ISD can provide lumbar stability comparable with Bilat instrumentation. It provides minimal rigidity in LB and AR when used alone to stabilize the segment after an IBS placement. The unilat and the more typical bilat screw constructs were shown to provide similar levels of stability in all directions after an IBS placement, though the bilat construct showed a trend toward improved stiffness overall.


Assuntos
Fixadores Internos , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia