Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 28(3): 478-480, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30239891

RESUMO

Less-invasive left ventricular assist device implantation is becoming the technique of choice for implementation of new-generation heart pumps. The less-invasive technique is particularly useful for patients with a history of cardiac surgical procedures, such as coronary artery bypass grafting. Yet, in redo cases, severe pericardial adhesions may force experienced operators to opt for alternative outflow graft placement, such as in the descending aorta. We propose a surgical technique in which the left ventricular device is implanted through a limited thoracic incision, with the outflow graft anastomosed to the ascending aorta, avoiding collision with coronary bypass grafts. The key element of the proposed technique is a tunnel connecting 2 pleural cavities, in which the outflow graft is placed, entirely bypassing the pericardium.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Toracotomia/métodos , Aorta Torácica/cirurgia , Doença da Artéria Coronariana/complicações , Insuficiência Cardíaca/complicações , Ventrículos do Coração , Humanos
2.
Kardiochir Torakochirurgia Pol ; 15(1): 23-26, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29681957

RESUMO

INTRODUCTION: High pulmonary vascular resistance (PVR) in orthotopic heart transplantation (OHT) candidates is a risk factor of right ventricle failure after the procedure. However, the increase of PVR may be a consequence of the life-threatening deterioration of the left ventricle function. The use of mechanical circulatory support (MCS) seems to be the best solution, but it is reimbursed only in active OHT candidates. AIM: We performed a retrospective analysis of MCS effectiveness in maintaining PVR at values accepted for OHT. MATERIAL AND METHODS: Starting from the year 2008 we identified 6 patients (all males, 42.8 ±17 years old) with dilated (n = 3), ischemic (n = 2), and restrictive cardiomyopathy (n = 1) in whom MCS - pulsatile left ventricle assist device (LVAD, n = 4), continuous flow LVAD (n = 1), and pulsatile biventricular assist device (BIVAD, n = 1) - was used at a time when PVR was unacceptable for OHT, and the reversibility test with nitroprusside was negative. After an average time of support of 261 ±129 days they were all transplanted. RESULTS: Right heart catheterization (RHC) results before MCS implantation were as follows: pulmonary artery systolic, diastolic, and mean pressure (PAPs/d/m) 60 ±20/28 ±7/40 ±11 mm Hg, pulmonary capillary wedge pressure (PCWP) 21 ±7 mm Hg, transpulmonary gradient (TPG) 19 ±7 mm Hg, cardiac output (CO) 3.6 ±0.8 l/min, PVR 5.7 ±2.1 Wood units (WU). Right heart catheterization results during MCS therapy were as follows: PAPs/d/s 27 ±11/12 ±4/17 ±6 mm Hg, PCWP 10 ±4 mm Hg, TPG 7 ±4 mm Hg, CO 5.1 ±0.7 l/min, PVR 1.4 ±0.6 WU. None of the patients experienced right ventricle failure after OHT with only one early loss due to multiorgan failure. CONCLUSIONS: Mechanical circulatory support is an effective method of pulmonary hypertension treatment for patients disqualified for OHT due to high PVR.

3.
Kardiochir Torakochirurgia Pol ; 14(1): 76-78, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28515757

RESUMO

Left ventricular assist device (LVAD) thrombosis remains a dreadful complication of mechanical circulatory support, with an incidence of 8-12% depending on the pump type and patient's comorbidities. Fibrinolysis may be considered early in pump thrombosis, but when contraindicated a pump exchange remains the only alternative. This short report documents an emergency LVAD exchange in a 55-year-old man who underwent LVAD (HeartWare Inc) implantation in 2013 as a bridge to transplantation. Four months after the initial surgery, he suffered from a hemorrhagic stroke despite properly managed anticoagulation. On February 17th, 2017 he was re-admitted with LVAD pump thrombosis. As fibrinolysis was contraindicated, an emergency pump exchange was performed via a limited thoracic incision in order to minimize surgical trauma, reduce intraoperative complications and facilitate immediate post-operative recovery. This report documents the very first LVAD pump exchange as well as the first one performed via a minimally invasive approach in Poland.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA