Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
NMR Biomed ; : e5178, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38784970

RESUMO

Phosphorus (31P) magnetic resonance spectroscopic imaging (MRSI) can serve as a critical tool for more direct quantification of brain energy metabolism, tissue pH, and cell membrane turnover. However, the low concentration of 31P metabolites in biological tissue may result in low signal-to-noise ratio (SNR) in 31P MRS images. In this work, we present an innovative design and construction of a 31P radiofrequency coil for whole-brain MRSI at 7 T. Our coil builds on current literature in ultra-high field 31P coil design and offers complete coverage of the brain, including the cerebellum and brainstem. The coil consists of an actively detunable volume transmit (Tx) resonator and a custom 24-channel receive (Rx) array. The volume Tx resonator is a 16-rung high-pass birdcage coil. The Rx coil consists of a 24-element phased array composed of catered loop shapes and sizes built onto a custom, close-fitting, head-shaped housing. The Rx array was designed to provide complete coverage of the head, while minimizing mutual coupling. The Rx configuration had a mean S 11 $$ {S}_{11} $$ reflection coefficient better than -20 decibels (dB) when the coil was loaded with a human head. The mean mutual coupling ( S 21 $$ {S}_{21} $$ ) among Rx elements, when loaded with a human head, was -16 dB. In phantom imaging, the phased array produced a central SNR that was 4.4-fold higher than the corresponding central SNR when operating the 31P birdcage as a transceiver. The peripheral SNR was 12-fold higher when applying the optimized phased array. In vivo 3D 31P MRSI experiments produced high-quality spectra in the cerebrum gray and white matter, as well as in the cerebellum. Characteristic phosphorus metabolites related to adenosine triphosphate metabolism and cell membrane turnover were distinguishable across all brain regions. In summary, our results demonstrate the potential of our novel coil for accurate, whole-brain 31P metabolite quantification.

2.
Pediatr Pulmonol ; 58(5): 1492-1500, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36751721

RESUMO

INTRODUCTION: Children with a history of bronchopulmonary dysplasia (BPD) may have lower physical activity levels, but evidence to date is mixed. This study compared physical activity levels between children born extremely preterm with and without history of BPD, and examined their associations with pulmonary magnetic resonance imaging (MRI) and pulmonary function test (PFT) indices. METHODS: This multicentre cross-sectional study included children aged 7-9 years born extremely preterm, with and without BPD. Children wore a pedometer for 1 week, then completed the Physical Activity Questionnaire (PAQ), pulmonary MRI, and PFT. Spearman correlations and multivariable linear regression modeling were performed. RESULTS: Of 45 children, 28 had a history of moderate-severe BPD. There were no differences in any physical activity outcomes by BPD status. Higher average daily step count and higher average daily moderate-to-vigorous physical activity (MVPA) were each correlated with greater forced vital capacity (r = 0.41 and 0.58), greater MRI lung proton density at full expiration (r = 0.42 and 0.49), and lower lung clearance index (r = -0.50 and -0.41). After adjusting for MRI total proton density and BPD status, a 5% increase in forced expiratory volume at 1 s was associated with 738 (95% CI: 208, 1268) more steps per day and 0.1 (0.0, 0.2) more hours of MVPA, respectively. CONCLUSION: School-aged children born extremely preterm have similar physical activity levels to their peers, regardless of history of BPD. MRI and PFT measures suggestive of gas trapping and/or airflow obstruction are associated with lower physical activity levels.


Assuntos
Displasia Broncopulmonar , Recém-Nascido , Humanos , Criança , Displasia Broncopulmonar/diagnóstico por imagem , Lactente Extremamente Prematuro , Estudos Transversais , Prótons , Pulmão/diagnóstico por imagem , Exercício Físico
3.
Ann Am Thorac Soc ; 19(7): 1149-1157, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35030070

RESUMO

Rationale: Children born prematurely, particularly those with bronchopulmonary dysplasia, have persisting lung abnormalities requiring longitudinal monitoring. Pulmonary ultrashort echo time magnetic resonance imaging (MRI) measurements may provide sensitive markers of persisting lung abnormalities and have not been evaluated in school-aged children born prematurely. Objectives: To compare pulmonary MRI and pulmonary function test measurements in preterm-born school-aged children with and without bronchopulmonary dysplasia. Methods: Children aged 7-9 years, born extremely preterm, with and without bronchopulmonary dysplasia, were recruited from three centers. Participants underwent pulmonary ultrashort echo time MRI and pulmonary function tests. Primary outcomes included total proton density and proton density at full expiration, measured using MRI. Multiple linear regression analysis was performed, adjusting for gestational age and bronchopulmonary dysplasia. Associations between MRI and pulmonary function were tested. Results: Thirty-five children were included in the primary analysis (24 with bronchopulmonary dysplasia, 11 without); 29 completed pulmonary function tests, of whom 11 (38%) had airflow limitation. Children with bronchopulmonary dysplasia had 44% (95% confidence interval [CI], 10-66%) lower mean total proton density (mean ± standard deviation, 3.6 ± 2.6) than those without (6.1 ± 4.0). Those with bronchopulmonary dysplasia had 25% (95% CI, 3-42%) lower proton density at full expiration than those without. Lower total proton density and proton density at full expiration were moderately correlated with greater residual volume, residual volume/total lung capacity, and lung clearance index (Spearman correlations for total proton density: -0.42, -0.57, and -0.53, respectively. Spearman correlations for proton density at full expiration: -0.28, -0.57, and -0.45, respectively). Conclusions: School-aged preterm-born children with bronchopulmonary dysplasia have parenchymal tissue abnormalities measured using ultrashort MRI proton density, compared with those without. MRI proton density correlated with pulmonary function measures indicative of gas trapping. Clinical trial registered with www.clinicaltrials.gov (NCT02921308).


Assuntos
Displasia Broncopulmonar , Pulmão , Displasia Broncopulmonar/diagnóstico por imagem , Criança , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Prótons , Testes de Função Respiratória
4.
Acad Radiol ; 28(8): e209-e218, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32532639

RESUMO

RATIONALE AND OBJECTIVES: Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a free-breathing 1H-based technique that produces maps of fractional ventilation (FV). This study compared ventilation defect percent (VDP) calculated using PREFUL to hyperpolarized (HP) 129Xe MRI and pulmonary function tests in pediatric cystic fibrosis (CF). MATERIALS AND METHODS: 27 pediatric participants were recruited (mean age 13.0 ± 2.7), including 6 with clinically stable CF, 11 CF patients undergoing a pulmonary exacerbation (PEx), and 10 healthy controls. Spirometry was performed to measure forced expiratory volume in 1 second (FEV1), along with nitrogen multiple breath washout to measure lung clearance index (LCI). VDP was calculated from single central coronal slice PREFUL FV maps and the corresponding HP 129Xe slice. RESULTS: The stable CF group had a normal FEV1 (p = 0.41) and elevated LCI (p = 0.007). The CF PEx group had a decreased FEV1 (p < 0.0001) and elevated LCI (p < 0.0001). PREFUL and HP 129Xe VDP were significantly different between the CF PEx and healthy groups (p < 0.05). In the stable CF group, PREFUL and HP 129Xe VDP were not significantly different from the healthy group (p = 0.18 and 0.08, respectively). There was a correlation between PREFUL and HP 129Xe VDP (R2 = 0.31, p = 0.004), and both parameters were significantly correlated with FEV1 and LCI. CONCLUSION: PREFUL MRI is feasible in pediatric CF, distinguishes patients undergoing pulmonary exacerbations compared to healthy subjects, and correlates with HP 129Xe MRI as well as functional measures of disease severity. PREFUL MRI does not require breath-holds and is straight forward to implement on any MRI scanner.


Assuntos
Fibrose Cística , Adolescente , Criança , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Testes de Função Respiratória , Isótopos de Xenônio
6.
AJR Am J Roentgenol ; 214(4): 817-824, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32045306

RESUMO

OBJECTIVE. The purpose of this study is to evaluate the diagnostic value of in vivo MR spectroscopy (MRS) with semilocalization by adiabatic selective refocusing (semi-LASER MRS) in differentiating clear cell renal cell carcinoma (RCC) from the non-clear cell subtype. SUBJECTS AND METHODS. Sixteen patients with biopsy-proven RCC or masses highly suspicious for RCC were prospectively recruited to participate in the study. Single-voxel 1H spectra were acquired using a 3-T MRI system, with a semi-LASER sequence acquired for renal tumors in 14 patients and for healthy renal tissue (control tissue) in 12 patients. Offline processing of the MR spectra was performed. MRI and spectra analysis were performed independently by radiologists who were blinded to the reference histopathologic findings. RESULTS. Semi-LASER MRS was diagnostic for nine of 11 patients (82%) with histopathologically proven clear cell RCC, showing a strong lipid peak in seven patients and a weaker lipid resonance in two others, whereas control spectra showed weakly positive findings in only one patient. MRS findings were negative for lipid resonance in two of three patients (67%) with non-clear cell tumors and were weakly positive in another patient. Semi-LASER MRS had a high sensitivity and positive predictive value of 82% and 90%, respectively, in addition to a specificity of 67%, a negative predictive value of 50%, and overall accuracy of 79% for the detection of clear cell RCC. Lipid resonance was detected by MRS for four of six clear cell RCCs with no intravoxel fat on chemical-shift MRI. CONCLUSION. The preliminary results of the present study show that semi-LASER MRS is promising for the noninvasive discrimination of clear cell RCC from non-clear cell RCC on the basis of detection of lipid resonance and that it provides an incremental yield compared with chemical-shift MRI.


Assuntos
Carcinoma de Células Renais/diagnóstico , Neoplasias Renais/diagnóstico , Espectroscopia de Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Biópsia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
7.
Magn Reson Med ; 84(1): 304-311, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31765507

RESUMO

PURPOSE: To assess the feasibility of hyperpolarized 129 Xe multiple-breath washout MRI in pediatric cystic fibrosis (CF) participants with preserved lung function. Fractional ventilation (r), defined as the fractional gas replacement per breath, was mapped using 2 signal models: (1) constant T1 and (2) variable T1 as a function of the hyperpolarized gas washout. METHODS: A total of 17 pediatric participants were recruited (mean age 11.7 ± 2.8 years), including 7 children with clinically stable CF and 10 aged-matched healthy controls. Pulmonary function tests were performed, including spirometry, to measure the forced expiratory volume in 1 second and nitrogen multiple-breath washout to measure the lung clearance index. Hyperpolarized 129 Xe MRI was performed during consecutive breaths of air following a single 129 Xe inhalation, and fractional ventilation maps were calculated. RESULTS: The forced expiratory volume in 1 second was similar in both groups (P = .32), but there was a statistically significant difference in lung clearance index between healthy and CF participants (P = .001). With variable T1 modeling, CF participants had a mean r of 0.44 ± 0.08 and healthy participants had a mean r of 0.37 ± 0.12 (P = .20). With constant T1 modeling, CF participants had a mean r' of 0.48 ± 0.08, and healthy participants had a mean r' of 0.43 ± 0.12 (P = .32). Therefore, assuming a constant T1 leads to a relative bias in r of 15.1% ± 6.4% and 20.8% ± 7.4% for CF and healthy participants, respectively (P = .12). CONCLUSION: This study demonstrates that hyperpolarized 129 Xe multiple-breath washout imaging is feasible in pediatric participants with CF, and inclusion of variable T1 modeling reduces bias in the fractional ventilation measurements.


Assuntos
Fibrose Cística , Adolescente , Idoso , Criança , Fibrose Cística/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Testes de Função Respiratória , Isótopos de Xenônio
8.
J Cyst Fibros ; 18(5): 728-733, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30922812

RESUMO

BACKGROUND: The ventilation defect percent (VDP), measured from hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI), is sensitive to functional changes in cystic fibrosis (CF) lung disease. The purpose of this study was to measure and compare VDP from HP 129Xe MRI acquired at two institutions in stable pediatric CF subjects with preserved lung function. METHODS: This retrospective analysis included 26 participants from two institutions (18 CF, 8 healthy, age range 10-17). Pulmonary function tests, N2 multiple breath washout (to measure lung clearance index, LCI), and HP 129Xe MRI were performed. VDP measurements were compared between two trained analysts using mean-anchored linear binning. Correlations were investigated for VDP compared to the forced expiratory volume in one second (FEV1) and LCI. RESULTS: VDP measurements agreed for the two analysts with an intraclass correlation coefficient of 0.99. In the combined dataset, VDP measured by Analyst 1 was 5.96 ±â€¯1.82% and 15.96 ±â€¯6.76% for the healthy and CF groups, respectively (p = .0004). Analyst 2 showed similar differences between healthy and CF (p = .0003). VDP measured by either analyst was shown to correlate with FEV1 (R2 = 0.33, p = .003; and R2 = 0.26, p = .009 for Analysts 1 and 2, respectively) and LCI (R2 = 0.76, p < .0001; and R2 = 0.77, p < .0001 for Analysts 1 and 2, respectively). CONCLUSION: HP 129Xe MRI provides a robust measurement of ventilation heterogeneity in stable pediatric CF subjects at two sites. Since measurements performed at two sites yielded similar VDP values with near-identical values between different analysts, implementation of the technique in multi-center trials in CF appears feasible.


Assuntos
Fibrose Cística , Pulmão , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio , Adolescente , Criança , Fibrose Cística/diagnóstico , Fibrose Cística/fisiopatologia , Feminino , Volume Expiratório Forçado , Indicadores Básicos de Saúde , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Ventilação Pulmonar , Testes de Função Respiratória/métodos , Estudos Retrospectivos
9.
Eur Respir J ; 53(5)2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30819815

RESUMO

Pulmonary magnetic resonance imaging using hyperpolarised 129Xe gas (XeMRI) can quantify ventilation inhomogeneity by measuring the percentage of unventilated lung volume (ventilation defect per cent (VDP)). While previous studies have demonstrated its sensitivity for detecting early cystic fibrosis (CF) lung disease, the utility of XeMRI to monitor response to therapy in CF is unknown. The aim of this study was to assess the ability of XeMRI to capture treatment response in paediatric CF patients undergoing inpatient antibiotic treatment for a pulmonary exacerbation.15 CF patients aged 8-18 years underwent XeMRI, spirometry, plethysmography and multiple-breath nitrogen washout at the beginning and end of inpatient treatment of a pulmonary exacerbation. VDP was calculated from XeMRI images obtained during a static breath hold using semi-automated k-means clustering and linear binning approaches.XeMRI was well tolerated. VDP, lung clearance index and the forced expiratory volume in 1 s all improved with treatment; however, response was not uniform in individual patients. Of all outcome measures, VDP showed the largest relative improvement (-42.1%, 95% CI -52.1--31.9%, p<0.0001).These data support further investigation of XeMRI as a tool to capture treatment response in CF lung disease.


Assuntos
Fibrose Cística/diagnóstico por imagem , Fibrose Cística/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Adolescente , Criança , Feminino , Volume Expiratório Forçado , Indicadores Básicos de Saúde , Humanos , Modelos Lineares , Masculino , Ontário , Estudos Prospectivos , Ventilação Pulmonar , Testes de Função Respiratória , Isótopos de Xenônio
10.
Acad Radiol ; 26(3): 344-354, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30087066

RESUMO

Conventional pulmonary function tests appear normal in early cystic fibrosis (CF) lung disease. Therefore, new diagnostic approaches are required that can detect CF lung disease in children and monitor treatment response. Hyperpolarized (HP) gas (129Xe and 3He) magnetic resonance imaging (MRI) is a powerful, emergent tool for mapping regional lung function and may be well suited for studying pediatric CF. HP gas MRI is well tolerated, reproducible, and it can be performed longitudinally without the need for ionizing radiation. In particular, quantification of the distribution of ventilation, or ventilation defect percent (VDP), has been shown to be a sensitive indicator of CF lung disease and correlates well with pulmonary function tests. This article presents the current state of CF diagnosis and treatment and describes the potential role of HP gas MRI for detection of early CF lung disease and following the effects of interventions. The typical HP gas imaging workflow is described, along with a discussion of image analysis to calculate VDP, dosing considerations, and the reproducibility of VDP. The potential use of VDP as an outcome measure in CF is discussed, by considering the correlation with pulmonary function measures, preliminary interventional studies, and case studies involving longitudinal imaging and pulmonary exacerbations. Finally, emerging HP gas imaging techniques such as multiple breath washout imaging are introduced, followed by a discussion of future directions. Overall, HP gas MRI biomarkers are expected to provide sensitive outcome measures that can be used in disease surveillance as well as interventional studies involving novel CF therapies.


Assuntos
Fibrose Cística/diagnóstico por imagem , Fibrose Cística/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Criança , Progressão da Doença , Feminino , Hélio , Humanos , Isótopos , Masculino , Reprodutibilidade dos Testes , Testes de Função Respiratória , Fluxo de Trabalho , Isótopos de Xenônio
11.
J Magn Reson Imaging ; 49(2): 343-354, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30248212

RESUMO

Fluorine-19 (19 F) MRI using inhaled inert fluorinated gases is an emerging technique that can provide functional images of the lungs. Inert fluorinated gases are nontoxic, abundant, relatively inexpensive, and the technique can be performed on any MRI scanner with broadband multinuclear imaging capabilities. Pulmonary 19 F MRI has been performed in animals, healthy human volunteers, and in patients with lung disease. In this review, the technical requirements of 19 F MRI are discussed, along with various imaging approaches used to optimize the image quality. Lung imaging is typically performed in humans using a gas mixture containing 79% perfluoropropane (PFP) or sulphur hexafluoride (SF6 ) and 21% oxygen. In lung diseases, such as asthma, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF), ventilation defects are apparent in regions that the inhaled gas cannot access. 19 F lung images are typically acquired in a single breath-hold, or in a time-resolved, multiple breath fashion. The former provides measurements of the ventilation defect percent (VDP), while the latter provides measurements of gas replacement (ie, fractional ventilation). Finally, preliminary comparisons with other functional lung imaging techniques are discussed, such as Fourier decomposition MRI and hyperpolarized gas MRI. Overall, functional 19 F lung MRI is expected to complement existing proton-based structural imaging techniques, and the combination of structural and functional lung MRI will provide useful outcome measures in the future management of pulmonary diseases in the clinic. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:343-354.


Assuntos
Imagem por Ressonância Magnética de Flúor-19 , Fluorocarbonos/administração & dosagem , Gases , Pulmão/diagnóstico por imagem , Hexafluoreto de Enxofre/administração & dosagem , Animais , Asma/diagnóstico por imagem , Calibragem , Fibrose Cística/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Pneumopatias , Oxigênio , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Respiração , Software
14.
NMR Biomed ; 29(5): 545-52, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26866511

RESUMO

The purpose of this study was to extend established methods for fractional ventilation mapping using (19) F MRI of inert fluorinated gases to rat models of pulmonary inflammation and fibrosis. In this study, five rats were instilled with lipopolysaccharide (LPS) in the lungs two days prior to imaging, six rats were instilled with bleomycin in the lungs two weeks prior to imaging and an additional four rats were used as controls. (19) F MR lung imaging was performed at 3 T with rats continuously breathing a mixture of sulfur hexafluoride and O2 . Fractional ventilation maps were obtained using a wash-out approach, by switching the breathing mixture to pure O2 , and acquiring images following each successive wash-out breath. The mean fractional ventilation (r) was 0.29 ± 0.05 for control rats, 0.23 ± 0.10 for LPS-instilled rats and 0.19 ± 0.03 for bleomycin-instilled rats. Bleomycin-instilled rats had a significantly decreased mean r value compared with controls (P = 0.010). Although LPS-instilled rats had a slightly reduced mean r value, this trend was not statistically significant (P = 0.556). Fractional ventilation gradients were calculated in the anterior/posterior (A/P) direction, and the mean A/P gradient was -0.005 ± 0.008 cm(-1) for control rats, 0.013 ± 0.005 cm(-1) for LPS-instilled rats and 0.009 ± 0.018 cm(-1) for bleomycin-instilled rats. Fractional ventilation gradients were significantly different for control rats compared with LPS-instilled rats only (P = 0.016). The ventilation gradients calculated from control rats showed the expected gravitational relationship, while ventilation gradients calculated from LPS- and bleomycin-instilled rats showed the opposite trend. Histology confirmed that LPS-instilled rats had a significantly elevated alveolar wall thickness, while bleomycin-instilled rats showed signs of substantial fibrosis. Overall, (19)F MRI may be able to detect the effects of pulmonary inflammation and fibrosis using a simple and inexpensive imaging approach that can potentially be translated to humans.


Assuntos
Halogenação , Imageamento por Ressonância Magnética/métodos , Gases Nobres/química , Pneumonia/diagnóstico , Fibrose Pulmonar/diagnóstico , Ventilação Pulmonar , Animais , Bleomicina , Modelos Animais de Doenças , Pulmão/patologia , Masculino , Pneumonia/induzido quimicamente , Alvéolos Pulmonares/patologia , Ratos Sprague-Dawley
15.
J Magn Reson Imaging ; 43(2): 295-315, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26218920

RESUMO

This review focuses on the state-of-the-art of the three major classes of gas contrast agents used in magnetic resonance imaging (MRI)-hyperpolarized (HP) gas, molecular oxygen, and fluorinated gas--and their application to clinical pulmonary research. During the past several years there has been accelerated development of pulmonary MRI. This has been driven in part by concerns regarding ionizing radiation using multidetector computed tomography (CT). However, MRI also offers capabilities for fast multispectral and functional imaging using gas agents that are not technically feasible with CT. Recent improvements in gradient performance and radial acquisition methods using ultrashort echo time (UTE) have contributed to advances in these functional pulmonary MRI techniques. The relative strengths and weaknesses of the main functional imaging methods and gas agents are compared and applications to measures of ventilation, diffusion, and gas exchange are presented. Functional lung MRI methods using these gas agents are improving our understanding of a wide range of chronic lung diseases, including chronic obstructive pulmonary disease, asthma, and cystic fibrosis in both adults and children.


Assuntos
Meios de Contraste , Gases , Aumento da Imagem/métodos , Pneumopatias/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética , Humanos
16.
Mol Imaging Biol ; 17(2): 149-62, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25228404

RESUMO

Magnetic resonance imaging (MRI) is a potentially ideal imaging modality for noninvasive, nonionizing, and longitudinal assessment of disease. Hyperpolarized (HP) agents have been developed in the past 20 years for MR imaging, and they have the potential to vastly improve MRI sensitivity for the diagnosis and management of various diseases. The polarization of nuclear magnetic resonance (NMR)-sensitive nuclei other than (1)H (e.g., (3)He, (129)Xe) can be enhanced by a factor of up to 100,000 times above thermal equilibrium levels, which enables direct detection of the HP agent with no background signal. In this review, a number of HP media applications in MR imaging are discussed, including HP (3)He and (129)Xe lung imaging, HP (129)Xe brain imaging, and HP (129)Xe biosensors. Inert fluorinated gas MRI, which is a new lung imaging technique that does not require hyperpolarization, is also briefly discussed. This technique will likely be an important future direction for the HP gas lung imaging community.


Assuntos
Imageamento por Ressonância Magnética , Gases Nobres/química , Animais , Técnicas Biossensoriais , Encéfalo/patologia , Humanos , Pulmão/patologia
17.
Magn Reson Med ; 74(2): 550-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25105721

RESUMO

PURPOSE: Inert fluorinated gas lung MRI is a new and promising alternative to hyperpolarized gas lung MRI; it is less expensive and does not require expensive isotopes/polarizers. The thermally polarized nature of signal obtained from fluorinated gases makes it relatively easy to use for dynamic lung imaging and for obtaining lung ventilation maps. In this study, we propose that the sensitivity and resolution of fluorine-19 (19F) in vivo images can be improved using the x-centric pulse sequence, thereby achieving a short echo time/pulse repetition time. This study is a transitional step for converting to more sustainable gases for lung imaging. METHODS: A 19F-resolution phantom was used to validate the efficiency of performing the x-centric pulse sequence on a clinical scanner. Ventilation maps were obtained in the lungs of five normal rats with a washout approach (adapted from Xe-enhanced computed tomography [Xe-CT] regional ventilation mapping), using mixtures of either sulfur hexafluoride/oxygen or perfluoropropane/oxygen and a two-breath x-centric method. RESULTS: Fractional ventilation (r) values obtained in this study (0.35-0.46 interval) were in good agreement with previously published values for 3He/129Xe. Calculated r gradients agreed well with published gradients obtained in rats with Xe-CT measurements. CONCLUSIONS: These results suggest that fluorinated gases can be reliably used in vivo in dynamic lung studies as an alternative to 3He/129Xe.


Assuntos
Algoritmos , Imagem por Ressonância Magnética de Flúor-19/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ventilação Pulmonar/fisiologia , Processamento de Sinais Assistido por Computador , Administração por Inalação , Animais , Gases/farmacocinética , Aumento da Imagem/métodos , Projetos Piloto , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
NMR Biomed ; 27(12): 1525-34, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25066661

RESUMO

Fluorine-19 ((19)F) MRI of the lungs using inhaled inert fluorinated gases can potentially provide high quality images of the lungs that are similar in quality to those from hyperpolarized (HP) noble gas MRI. Inert fluorinated gases have the advantages of being nontoxic, abundant, and inexpensive compared with HP gases. Due to the high gyromagnetic ratio of (19)F, there is sufficient thermally polarized signal for imaging, and averaging within a single breath-hold is possible due to short longitudinal relaxation times. Therefore, the gases do not need to be hyperpolarized prior to their use in MRI. This eliminates the need for an expensive polarizer and expensive isotopes. Inert fluorinated gas MRI of the lungs has been previously demonstrated in animals, and more recently in healthy volunteers and patients with lung diseases. The ongoing improvements in image quality demonstrate the potential of (19)F MRI for visualizing the distribution of ventilation in human lungs and detecting functional biomarkers. In this brief review, the development of inert fluorinated gas MRI, current progress, and future prospects are discussed. The current state of HP noble gas MRI is also briefly discussed in order to provide context to the development of this new imaging modality. Overall, this may be a viable clinical imaging modality that can provide useful information for the diagnosis and management of chronic respiratory diseases.


Assuntos
Halogenação , Pulmão/fisiologia , Imageamento por Ressonância Magnética/métodos , Gases Nobres , Animais , Gravitação , Humanos , Respiração
19.
Radiology ; 269(3): 903-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23985278

RESUMO

PURPOSE: To perform static breath-hold fluorine 19 ((19)F) three-dimensional (3D) ultrashort echo time (UTE) magnetic resonance (MR) imaging of the lungs in healthy volunteers by using a mixture of 79% perfluoropropane (PFP) and 21% O2. MATERIALS AND METHODS: This study protocol was approved by the local research ethics board and by Health Canada. All volunteers provided written informed consent. Ten healthy volunteers underwent MR imaging at 3.0 T. Fluorine 19 3D UTE MR images were acquired during a 15-second breath hold according to one of two breathing protocols: protocol A, a 1-L inhalation of a mixture of 79% PFP and 21% O2, and protocol B, continuous breathing from a 5-L bag of a mixture of 79% PFP and 21% O2 followed by a 1-L inhalation of the same PFP-O2 mixture from a separate bag and a subsequent breath hold. The signal-to-noise ratio (SNR) was measured in the three most central image sections and was compared between breathing protocols by using an unpaired t test. RESULTS: Overall, the SNR was significantly greater for breathing protocol B (continuous breathing) than for breathing protocol A (single breath) (P = .018). The mean SNRs were 18 ± 6 (standard deviation) and 32 ± 6 for images acquired by using breathing protocols A and B, respectively. Breathing protocol B improves SNR by "washing out" the air from the lungs and increasing the PFP concentration prior to (19)F imaging. CONCLUSION: This study demonstrates the feasibility of (19)F 3D UTE static breath-hold MR imaging of human lungs with inert fluorinated gases.


Assuntos
Flúor/administração & dosagem , Fluorocarbonos/administração & dosagem , Imageamento Tridimensional , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Oxigênio/administração & dosagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA