Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiol Imaging Cancer ; 6(2): e230080, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38334471

RESUMO

Purpose To determine if microwave ablation (MWA) of retroperitoneal tumors can safely provide high rates of local tumor control. Materials and Methods This retrospective study included 19 patients (median age, 65 years [range = 46-78 years]; 13 [68.4%] men and six [31.6%] women) with 29 retroperitoneal tumors treated over 22 MWA procedures. Hydrodissection (0.9% saline with 2% iohexol) was injected in 17 of 22 (77.3%) procedures to protect nontarget anatomy. The primary outcomes evaluated were local tumor progression (LTP) and complication rates. Oncologic outcomes, including overall survival (OS), progression-free survival (PFS), and treatment-free interval (TFI), were examined as secondary outcome measures. Results Median follow-up was 18 months (range = 0.5-113). Hydrodissection was successful in displacing nontarget anatomy in 16 of 17 (94.1%) procedures. The LTP rate was 3.4% (one of 29; 95% CI: 0.1, 17.8) per tumor and 5.3% (one of 19; 95% CI: 0.1, 26.0) per patient. The overall complication rate per patient was 15.8% (three of 19), including two minor complications and one major complication. The OS rate at 1, 2, and 3 years was 81.8%, 81.8%, and 72.7%, respectively, with a median OS estimated at greater than 7 years. There was no evidence of a difference in OS (P = .34) and PFS (P = .56) between patients with renal cell carcinoma (six of 19 [31.6%]) versus other tumors (13 of 19 [68.4%]) and patients treated with no evidence of disease (15 of 22 [68.2%]) versus patients with residual tumors (seven of 22 [31.8%]). Median TFI was 18 months (range = 0.5-108). Conclusion Treatment of retroperitoneal tumors with MWA combined with hydrodissection provided high rates of local control, prolonged systemic therapy-free intervals, and few serious complications. Keywords: Ablation Techniques (ie, Radiofrequency, Thermal, Chemical), Retroperitoneum, Microwave Ablation, Hydrodissection © RSNA, 2024.


Assuntos
Neoplasias Renais , Neoplasias Retroperitoneais , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/radioterapia , Neoplasias Retroperitoneais/cirurgia , Resultado do Tratamento , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia
2.
Tech Vasc Interv Radiol ; 26(3): 100911, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38071032

RESUMO

CT navigation (CTN) has recently been developed to combine many of the advantages of conventional CT and CT-fluoroscopic guidance for needle placement. CTN systems display real-time needle position superimposed on a CT dataset. This is accomplished by placing electromagnetic (EM) or optical transmitters/sensors on the patient and needle, combined with fiducials placed within the scan field to superimpose a known needle location onto a CT dataset. Advantages of CTN include real-time needle tracking using a contemporaneous CT dataset with the patient in the treatment position, reduced radiation to the physician, facilitation of procedures outside the gantry plane, fewer helical scans during needle placement, and needle guidance based on diagnostic-quality CT datasets. Limitations include the display of a virtual (vs actual) needle position, which can be inaccurate if the needle bends, the fiducial moves, or patient movement occurs between scans, and limitations in anatomical regions with a high degree of motion such as the lung bases. This review summarizes recently introduced CTN technologies in comparison to historical methods of CT needle guidance. A "How I do it" section follows, which describes how CT navigation has been integrated into the study center for both routine and challenging procedures, and includes step-by-step explanations, technical tips, and pitfalls.


Assuntos
Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Fenômenos Eletromagnéticos , Cirurgia Assistida por Computador/métodos
3.
J Vasc Interv Radiol ; 34(11): 1986-1996, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37481064

RESUMO

PURPOSE: To compare the safety and efficacy of histotripsy with cryoablation in a chronic human-scale normal porcine kidney model. MATERIALS AND METHODS: Eighteen female domestic swine were divided evenly into histotripsy and cryoablation treatment arms. A planned 2-3 cm diameter treatment was performed under ultrasound (histotripsy) or ultrasound and computed tomography (CT) guidance (cryoablation). Contrast-enhanced CT and serum blood analysis were performed immediately postprocedure and on day 7, with either immediate killing (n = 3) or continued survival to day 30 (n = 6), at which time contrast-enhanced CT, serum blood analysis, and necropsy were performed. Animal welfare, treatment zone appearance, procedure-related adverse events, and histopathology of the treatment zones and surrounding tissues were assessed. RESULTS: Histotripsy treatment zones (mean ±standard deviation diameters, 2.7 ± 0.12 × 2.4 ± 0.19 × 2.4 ± 0.26 cm; volume, 8.3 ± 1.9 cm3) were larger than cryoablation zones (mean diameters, 2.2 ± 0.19 × 1.9 ± 0.13 × 1.7 ± 0.19 cm; volume, 3.9 ± 0.8 cm3; P < .001). At 30 days, histotripsy and cryoablation treatment zone volumes decreased by 96% and 83% on CT, respectively (P < .001). Perirenal hematomas were present after 8 of 9 (89%) cryoablation (mean volume, 22.2 cm3) and 1 of 9 (11%, P < .001) histotripsy (volume, 0.4 cm3) procedures, with active arterial extravasation in 4 of 9 (44%) cryoablation and no histotripsy animals (P = .206). All 9 histotripsy animals and 5 of 9 (56%) cryoablation animals had collecting system debris (P = .042). Changes in serum creatinine were similar between the groups (P = .321). CONCLUSIONS: Other than a higher rate of bleeding after cryoablation, the safety and early efficacy of histotripsy and cryoablation were comparable for creating treatment zones in a chronic normal porcine kidney model.


Assuntos
Criocirurgia , Neoplasias Renais , Humanos , Suínos , Feminino , Animais , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Rim/patologia , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X , Hemorragia Gastrointestinal/etiologia , Resultado do Tratamento
4.
J Vasc Interv Radiol ; 34(5): 910-918, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36736821

RESUMO

PURPOSE: To compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis. MATERIALS AND METHODS: A retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d'Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm). RESULTS: The population was well-matched (age, 65 vs 65 years; target size, 2.0 vs 2.1 cm; skin-to-target distance, 11.4 vs 10.7 cm; P > .05, EMN vs CT fluoroscopy, respectively). Technical success (98% vs 100%), diagnostic yield (98% vs 95%), adverse events (2% vs 5%), and procedure time (33 minutes vs 31 minutes) were not statistically different (P > .05). Operator radiation dose was less with EMN than with CT fluoroscopy (0.04 vs 1.2 µGy; P < .001), but patient dose was greater (30.1 vs 9.6 mSv; P < .001) owing to more helical scans during EMN guidance (3.9 vs 2.1; P < .001). CT fluoroscopy was performed with a mean of 29.7 tap scans per case. In 3 (3%) cases, CT fluoroscopy was performed with gantry tilt, and the mean angle out of plane for EMN cases was 13.4°. CONCLUSIONS: Percutaneous biopsies guided by EMN and CT fluoroscopy were closely matched for technical success, diagnostic yield, procedure time, and adverse events in a matched cohort of patients. EMN cases were more likely to be performed outside of the gantry plane. Radiation dose to the operator was higher with CT fluoroscopy, and patient radiation dose was higher with EMN. Further study with a wider array of procedures and anatomic locations is warranted.


Assuntos
Fenômenos Eletromagnéticos , Tomografia Computadorizada por Raios X , Humanos , Idoso , Estudos Retrospectivos , Biópsia , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Abdome , Pelve , Fluoroscopia
5.
J Vasc Interv Radiol ; 34(3): 386-394.e2, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36503074

RESUMO

PURPOSE: To determine the risk of mechanical vessel wall damage resulting in hemorrhage during and after hepatic and renal histotripsy in an anticoagulated in vivo porcine model. MATERIALS AND METHODS: Non-tumor-bearing pigs (n = 8; mean weight, 52.5 kg) were anticoagulated with warfarin (initial dose, 0.08 mg/kg) to a target prothrombin time (PT) of 30%-50% above baseline. A total of 15 histotripsy procedures were performed (kidney: n = 8, 2.0-cm sphere; liver: n = 7, 2.5-cm sphere). Treatments were immediately followed by computed tomography (CT) imaging. Animals were observed for 7 days while continuing anticoagulation, followed by repeat CT and necropsy. RESULTS: All animals survived to complete the entire protocol with no signs of disability or distress. Three animals had hematuria (pink urine without clots). Baseline PT values (mean, 16.0 seconds) were elevated to 22.0 seconds (37.5% above baseline, P = .003) on the day of treatment and to 28.8 seconds (77.8% above baseline, P < .001) on the day of necropsy. At the time of treatment, 5 of 8 (63%) animals were at a therapeutic anticoagulation level, and all 8 animals (100%) reached therapeutic levels by the time of necropsy. There were no cases of intraparenchymal, peritoneal, or retroperitoneal hemorrhage associated with any treatments despite 5 of 7 (71%) liver and all 8 (100%) kidney treatments extending to the organ surface. CONCLUSIONS: Liver and kidney histotripsy seems safe with no elevated bleeding risk in this anticoagulated animal model, supporting the possibility of histotripsy treatments in patients on anticoagulation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Fígado , Suínos , Animais , Rim , Hemorragia/etiologia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Anticoagulantes
6.
Eur Radiol ; 33(2): 1050-1062, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048208

RESUMO

OBJECTIVE: To compare the acute and chronic safety and treatment effects of non-invasive hepatic histotripsy vs. percutaneous microwave (MW) ablation in a healthy porcine model. METHODS: This was a dual-arm study in which each animal (n = 14) received either a single hepatic microwave (n = 6) or histotripsy (n = 6 single treatment; n = 2 double treatment) under ultrasound guidance. The goal was to create 2.5-3.0 cm short-axis treatments in similar locations across modalities. Animals were survived for 1 month with contrast-enhanced CT imaging on days 0, 2, 7, 14, and 28. On day 28, necropsy and histopathology were performed. RESULTS: All procedures were well-tolerated. MW ablation zones were longer and more oblong, but equivalent in the short axes to histotripsy zones on immediate post-procedure CT (p < 0.001 and p = 0.45, respectively). Overall, MW volumes were larger (21.4 cm3 vs. 13.4 cm3; p = 0.001) and histotripsy treatment zones were more spherical (p = 0.007). Histotripsy zones were close to the prescribed size (p < 0.001). Over the study period, histotripsy treatment zones decreased in volume while microwave ablation zones slightly increased (-83% vs. +17%, p = 0.001). There were several imaging-only findings: Branch portal vein thrombus with both histotripsy (7/8) and MW (6/6), hematoma in 2/6 MW only, and a gallbladder injury in 1/6 MW animals. The ablation zones demonstrated complete cellular destruction for both modalities. CONCLUSION: Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution. Hepatic MW and histotripsy treatment in a normal porcine model appear at least equally effective for creating treatment zones with a similar safety profile. KEY POINTS: • Microwave ablation and histotripsy for liver treatment in a healthy porcine model yield equivalent procedural tolerance and cellular destruction. • Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution over the 28-day follow-up period. • These findings confirm the safety and efficacy of hepatic histotripsy and support the pursuit of clinical trials to further evaluate the translatability of these results.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Micro-Ondas/uso terapêutico , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/irrigação sanguínea , Técnicas de Ablação/métodos , Veia Porta/cirurgia , Ablação por Cateter/métodos
7.
J Vasc Interv Radiol ; 33(9): 1045-1053, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35667580

RESUMO

PURPOSE: To evaluate the efficacy and safety of microwave (MW) ablation as first-line locoregional therapy (LRT) for bridging patients with hepatocellular carcinoma (HCC) to liver transplant. MATERIALS AND METHODS: This retrospective study evaluated 88 patients who received percutaneous MW ablation for 141 tumors as first-line LRT for HCC and who were listed for liver transplantation at a single medical center between 2011 and 2019. The overall survival (OS) rate statuses after liver transplant, waitlist retention, and disease progression were evaluated using the Kaplan-Meier techniques. RESULTS: Among the 88 patients (72 men and 16 women; mean age, 60 years; Model for End-Stage Liver Disease score, 11.2) who were listed for transplant, the median waitlist time was 9.4 months (interquartile range, 5.5-18.9). Seventy-one (80.7%) patients received transplant after a median waitlist time of 8.5 months. Seventeen (19.3%) patients were removed from the waitlist; of these, 4 (4.5%) were removed because of tumors outside of the Milan criteria (HCC-specific dropout). No difference in tumor size or alpha-fetoprotein was observed in the transplanted versus nontransplanted patients at the time of ablation (2.1 vs 2.1 cm and 34.4 vs 34.7 ng/mL for transplanted vs nontransplanted, respectively; P > .05). Five (5.1%) of the 88 patients experienced adverse events after ablation; however, they all recovered. There were no cases of tract seeding. The local tumor progression (LTP) rate was 7.2%. The OS status after liver transplant at 5 years was 76.7%, and the disease-specific survival after LTP was 89.6%, with a median follow-up of 61 months for all patients. CONCLUSIONS: MW ablation appears to be safe and effective for bridging patients with HCC to liver transplant without waitlist removal from seeding, adverse events, or LTP.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Doença Hepática Terminal , Neoplasias Hepáticas , Transplante de Fígado , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/métodos , Masculino , Micro-Ondas/efeitos adversos , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
8.
J Gastrointest Oncol ; 12(4): 1454-1469, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34532102

RESUMO

BACKGROUND: The purpose of this study is to evaluate the safety and intermediate-term efficacy of percutaneous microwave (MW) ablation for the treatment of colorectal liver metastases (CRLM) at a single institution. METHODS: A retrospective review was performed of all CRLM treated with MW ablation from 3/2011 to 7/2020 (102 tumors; 72 procedures; 57 patients). Mean age was 60 years (range, 36-88) and mean tumor size was 1.8 cm (range, 0.5-5.0 cm). The patient population included 19 patients with extra-hepatic disease. Chemotherapy (pre- and/or post-ablation) was given in 98% of patients. Forty-five sessions were preceded by other focal CRLM treatments including resection, ablation, radiation, and radioembolization. Kaplan-Meier curves were used to estimate local tumor progression-free survival (LTPFS), disease-free survival (DFS), and overall survival (OS) and multivariate analysis (Cox Proportional Hazards model) was used to test predictors of OS. RESULTS: Technical success (complete ablation) was 100% and median follow-up was 42 months (range, 1-112). There was a 4% major complication rate and an overall complication rate of 8%. Local tumor progression (LTP) rate during the entire study period was 4/98 (4%), in which 2 were retreated with MW ablation for a secondary LTP-rate of 2%. LTP-free survival at 1, 3, and 5 years was 93%, 58%, and 39% and median LTP-free survival was 48 months. OS at 1, 3, and 5 years was 96%, 66%, 47% and median OS was 52 months. There were no statistically significant predictors of OS. CONCLUSIONS: MW ablation of hepatic colorectal liver metastases appears safe with excellent local tumor control and prolonged survival compared to historical controls in selected patients. Further comparative studies with other local treatment strategies appear indicated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA