Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Appl Clin Med Phys ; 25(6): e14359, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38689502

RESUMO

PURPOSE: AAPM Task Group No. 263U1 (Update to Report No. 263 - Standardizing Nomenclatures in Radiation Oncology) disseminated a survey to receive feedback on utilization, gaps, and means to facilitate further adoption. METHODS: The survey was created by TG-263U1 members to solicit feedback from physicists, dosimetrists, and physicians working in radiation oncology. Questions on the adoption of the TG-263 standard were coupled with demographic information, such as clinical role, place of primary employment (e.g., private hospital, academic center), and size of institution. The survey was emailed to all AAPM, AAMD, and ASTRO members. RESULTS: The survey received 463 responses with 310 completed survey responses used for analysis, of whom most had the clinical role of medical physicist (73%) and the majority were from the United States (83%). There were 83% of respondents who indicated that they believe that having a nomenclature standard is important or very important and 61% had adopted all or portions of TG-263 in their clinics. For those yet to adopt TG-263, the staffing and implementation efforts were the main cause for delaying adoption. Fewer respondents had trouble adopting TG-263 for organs at risk (29%) versus target (44%) nomenclature. Common themes in written feedback were lack of physician support and available resources, especially in vendor systems, to facilitate adoption. CONCLUSIONS: While there is strong support and belief in the benefit of standardized nomenclature, the widespread adoption of TG-263 has been hindered by the effort needed by staff for implementation.  Feedback from the survey is being utilized to drive the focus of the update efforts and create tools to facilitate easier adoption of TG-263.


Assuntos
Radioterapia (Especialidade) , Terminologia como Assunto , Humanos , Radioterapia (Especialidade)/normas , Inquéritos e Questionários , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Guias de Prática Clínica como Assunto , Percepção
2.
Pract Radiat Oncol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636586

RESUMO

Although standardization has been shown to improve patient safety and improve the efficiency of workflows, implementation of standards can take considerable effort and requires the engagement of all clinical stakeholders. Engaging team members includes increasing awareness of the proposed benefit of the standard, a clear implementation plan, monitoring for improvements, and open communication to support successful implementation. The benefits of standardization often focus on large institutions to improve research endeavors, yet all clinics can benefit from standardization to increase quality and implement more efficient or automated workflow. The benefits of nomenclature standardization for all team members and institution sizes, including success stories, are discussed with practical implementation guides to facilitate the adoption of standardized nomenclature in radiation oncology.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38387813

RESUMO

PURPOSE: Women remain underrepresented in medical physics in the United States, and determinants of persisting disparities remain unclear. Here, we performed a detailed investigation of American Association of Physicists in Medicine (AAPM) membership trajectories to evaluate trends in Full membership with respect to gender, age, and highest degree. METHODS AND MATERIALS: Membership data, including gender, date of birth, highest degree, membership type, and years of active membership for 1993 to 2023 were obtained from AAPM. Group 1 included Full members who joined AAPM in 1993 or later. A subset of group 1 including only members who joined and left AAPM since 1993 (former members, group 1F) was used to calculate age at membership cessation and duration. Results were compared by gender and highest degree. A Kaplan-Meier analysis was also used to evaluate membership "survival" by age and highest degree. RESULTS: Complete data were available for 6647 current and former Full members (group 1), including 2211 former members (group 1F). On average, women became Full members at a significantly younger age than men (34.6 vs 37.5 years of age, P < .001) and ended their memberships (if applicable) at a significantly younger age than men (46.1 vs 50.1 years of age, P < .001). The Kaplan-Meier "survival" analysis showed that for a given age, women were at a significantly greater risk of membership cessation than men, and women with master's degrees had the lowest membership survival of any gender/degree subgroup. When analyzing by membership duration, there was no difference in survival by gender alone. Still, women with PhDs were found to have the greatest membership survival among gender/degree subgroups. CONCLUSIONS: Both gender and degree type influenced AAPM membership trajectories. Although we have offered a discussion of possible explanations, qualitative data collected from both continuing and departing AAPM members will be critical in the ongoing journey toward gender parity in the profession of medical physics.

4.
Int J Radiat Oncol Biol Phys ; 118(3): 859-863, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37778423

RESUMO

PURPOSE: Consistency of nomenclature within radiation oncology is increasingly important as big data efforts and data sharing become more feasible. Automation of radiation oncology workflows depends on standardized contour nomenclature that enables toxicity and outcomes research, while also reducing medical errors and facilitating quality improvement activities. Recommendations for standardized nomenclature have been published in the American Association of Physicists in Medicine (AAPM) report from Task Group 263 (TG-263). Transitioning to TG-263 requires creation and management of structure template libraries and retraining of staff, which can be a considerable burden on clinical resources. Our aim is to develop a program that allows users to create TG-263-compliant structure templates in English, Spanish, or French to facilitate data sharing. METHODS AND MATERIALS: Fifty-three premade structure templates were arranged by treated organ based on an American Society for Radiation Oncology (ASTRO) consensus paper. Templates were further customized with common target structures, relevant organs at risk (OARs) (eg, spleen for anatomically relevant sites such as the gastroesophageal junction or stomach), subsite- specific templates (eg, partial breast, whole breast, intact prostate, postoperative prostate, etc) and brachytherapy templates. An informal consensus on OAR and target coloration was also achieved, although color selections are fully customizable within the program. RESULTS: The resulting program is usable on any Windows system and generates template files in practice-specific Digital Imaging and Communications In Medicine (DICOM) or XML formats, extracting standardized structure nomenclature from an online database maintained by members of the TG-263U1, which ensures continuous access to up-to-date templates. CONCLUSIONS: We have developed a tool to easily create and name DICOM radiation therapy (DICOM-RT) structures sets that are TG-263-compliant for all planning systems using the DICOM standard. The program and source code are publicly available via GitHub to encourage feedback from community users for improvement and guide further development.


Assuntos
Braquiterapia , Radioterapia (Especialidade) , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Software , Braquiterapia/métodos
5.
J Appl Clin Med Phys ; 24(12): e14133, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37643456

RESUMO

PURPOSE: With the clinical implementation of kV-CBCT-based daily online-adaptive radiotherapy, the ability to monitor, quantify, and correct patient movement during adaptive sessions is paramount. With sessions lasting between 20-45 min, the ability to detect and correct for small movements without restarting the entire session is critical to the adaptive workflow and dosimetric outcome. The purpose of this study was to quantify and evaluate the correlation of observed patient movement with machine logs and a surface imaging (SI) system during adaptive radiation therapy. METHODS: Treatment machine logs and SGRT registration data log files for 1972 individual sessions were exported and analyzed. For each session, the calculated shifts from a pre-delivery position verification CBCT were extracted from the machine logs and compared to the SGRT registration data log files captured during motion monitoring. The SGRT calculated shifts were compared to the reported shifts of the machine logs for comparison for all patients and eight disease site categories. RESULTS: The average (±STD) net displacement of the SGRT shifts were 2.6 ± 3.4 mm, 2.6 ± 3.5 mm, and 3.0 ± 3.2 in the lateral, longitudinal, and vertical directions, respectively. For the treatment machine logs, the average net displacements in the lateral, longitudinal, and vertical directions were 2.7 ± 3.7 mm, 2.6 ± 3.7 mm, and 3.2 ± 3.6 mm. The average difference (Machine-SGRT) was -0.1 ± 1.8 mm, 0.2 ± 2.1 mm, and -0.5 ± 2.5 mm for the lateral, longitudinal, and vertical directions. On average, a movement of 5.8 ± 5.6 mm and 5.3 ± 4.9 mm was calculated prior to delivery for the CBCT and SGRT systems, respectively. The Pearson correlation coefficient between CBCT and SGRT shifts was r = 0.88. The mean and median difference between the treatment machine logs and SGRT log files was less than 1 mm for all sites. CONCLUSION: Surface imaging should be used to monitor and quantify patient movement during adaptive radiotherapy.


Assuntos
Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Radioterapia Guiada por Imagem/métodos , Posicionamento do Paciente/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento , Dosagem Radioterapêutica , Tomografia Computadorizada de Feixe Cônico/métodos
6.
J Appl Clin Med Phys ; 24(10): e14058, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37289550

RESUMO

PURPOSE: To commission and assess the clinical performance of a new commercial surface imaging (SI) system by analyzing intra-fraction motion from the initial cohort of patients treated with frameless stereotactic radiosurgery (fSRS). METHODS: The IDENTIFYTM SI system was commissioned for clinical use on an Edge (Varian Medical Systems, Palo Alto, CA) linear accelerator. All patients who received intracranial radiotherapy with HyperArcTM (Varian Medical Systems, Palo Alto, CA) were immobilized with the EncompassTM (Qfix, Avondale, PA) thermoplastic mask and monitored for intra-fraction motion with SI. IDENTIFYTM log files were correlated with trajectory log files to correlate treatment parameters with SI-reported offsets. IDENTIFYTM reported offsets were correlated with gantry and couch angles to assess system performance for obstructed and clear camera field of view. Data were stratified by race to evaluate performance differences due to skin tone. RESULTS: All commissioning data were found to meet recommended tolerances. IDENTIFYTM was used to monitor intra-fraction motion on 1164 fractions from 386 patients. The median magnitude of translational SI reported offsets at the end of treatment was 0.27 mm. SI reported offsets were shown to increase when camera pods are blocked by the gantry with larger increases seen at non-zero couch angles. With camera obstruction, the median magnitude of the SI reported offset was 0.50 and 0.80 mm for White and Black patients, respectively. CONCLUSIONS: IDENTIFYTM performance during fSRS is comparable to other commercially available SI systems where offsets are shown to increase at non-zero couch angles and during camera pod blockage.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Posicionamento do Paciente/métodos , Aceleradores de Partículas , Imagens de Fantasmas , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/radioterapia
7.
Int J Radiat Oncol Biol Phys ; 117(3): 533-550, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37244628

RESUMO

PURPOSE: The ongoing lack of data standardization severely undermines the potential for automated learning from the vast amount of information routinely archived in electronic health records (EHRs), radiation oncology information systems, treatment planning systems, and other cancer care and outcomes databases. We sought to create a standardized ontology for clinical data, social determinants of health, and other radiation oncology concepts and interrelationships. METHODS AND MATERIALS: The American Association of Physicists in Medicine's Big Data Science Committee was initiated in July 2019 to explore common ground from the stakeholders' collective experience of issues that typically compromise the formation of large inter- and intra-institutional databases from EHRs. The Big Data Science Committee adopted an iterative, cyclical approach to engaging stakeholders beyond its membership to optimize the integration of diverse perspectives from the community. RESULTS: We developed the Operational Ontology for Oncology (O3), which identified 42 key elements, 359 attributes, 144 value sets, and 155 relationships ranked in relative importance of clinical significance, likelihood of availability in EHRs, and the ability to modify routine clinical processes to permit aggregation. Recommendations are provided for best use and development of the O3 to 4 constituencies: device manufacturers, centers of clinical care, researchers, and professional societies. CONCLUSIONS: O3 is designed to extend and interoperate with existing global infrastructure and data science standards. The implementation of these recommendations will lower the barriers for aggregation of information that could be used to create large, representative, findable, accessible, interoperable, and reusable data sets to support the scientific objectives of grant programs. The construction of comprehensive "real-world" data sets and application of advanced analytical techniques, including artificial intelligence, holds the potential to revolutionize patient management and improve outcomes by leveraging increased access to information derived from larger, more representative data sets.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Humanos , Inteligência Artificial , Consenso , Neoplasias/radioterapia , Informática
9.
Int J Radiat Oncol Biol Phys ; 116(2): 314-327, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36252781

RESUMO

PURPOSE: Gender-based discrimination and sexual harassment have been well-studied in the fields of science, technology, engineering, math, and medicine. However, less is known about these topics and their effect within the profession of medical physics. We aimed to better understand and clarify the views and experiences of practicing medical physicists and medical physics residents regarding gender-based discrimination and sexual harassment. METHODS AND MATERIALS: We conducted in-depth, semistructured, and confidential interviews with 32 practicing medical physicists and medical physics residents across the United States. The interviews were broad and covered the topics of discrimination, mentorship, and work/life integration. All participants were associated with a department with a residency program accredited by the Commission on Accreditation of Medical Physics Education Programs and had appointments with a clinical component. RESULTS: Participants shared views about gender-based discrimination and sexual harassment that were polarized. Some perceived that discrimination and harassment were a current concern within medical physics, while some either perceived that they were not a concern or that discrimination positively affected women and minoritized populations. Many participants shared personal experiences of discrimination and harassment, including those related to unequal compensation, discrimination against mothers, discrimination during the hiring process, gender-biased assumptions about behaviors or goals, communication biases, and overt and persistent sexual harassment. CONCLUSIONS: There is an urgent need to acknowledge, better understand, and address gender-based discrimination and sexual harassment in the field of medical physics.


Assuntos
Medicina , Assédio Sexual , Humanos , Feminino , Estados Unidos , Inquéritos e Questionários , Sexismo , Física
10.
J Appl Clin Med Phys ; 23(8): e13697, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35819973

RESUMO

PURPOSE: To validate surface imaging (SI)-reported offsets using a six degree-of-freedom couch and an anthropomorphic phantom for commissioning and routine quality assurance of an SI system used for stereotactic radiosurgery (SRS). METHODS: An anthropomorphic phantom with a radiopaque ball bearing (BB) placed either anterior, midline, or posterior, was tracked with SI with a typical SRS region of interest. Couch motion in all six degrees of freedom was programmed and delivered on a linac. SI system logs were synchronized with linac trajectory logs. Ten random couch positions were selected at couch 0°, 45°, 90°, 270°, 315° with megavolt (MV) images taken to account for couch walkout. The SI residual error (ε), the difference between SI reported offset and MV or trajectory log position, was calculated. Residual errors were measured with and without one SI pod blocked. RESULTS: The median [range] of magnitude of translational ε was 0.13 [0.07, 0.21], 0.16 [0.11, 0.26], 0.61 [0.50, 0.68], 0.49 [0.42, 0.55], 0.55 [0.38, 0.72] mm for couch rotations of 0°, 45°, 90°, 270°, 315°, respectively, for the midline BB and no pod blocked. The range of all translational ε from all couch angles (with and without pod block) at different BB positions is [0.05, 0.96] mm. The absolute range of difference when changing BB position when no pod is blocked in median translational ε is [0.01, 0.40] mm with the maximum at BB posterior. The absolute range of difference when not changing BB positions with and without pod block in median translational ε is [0.01, 0.37] mm with the maximum at BB posterior and couch 315°. CONCLUSION: SI system and linac trajectory log analysis can be used to assess SI system performance with automated couch motion to validate SI accuracy.


Assuntos
Radiocirurgia , Humanos , Movimento (Física) , Aceleradores de Partículas , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
J Pharm Technol ; 38(4): 218-224, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35832564

RESUMO

Background: Vancomycin and piperacillin-tazobactam (VPT) is a common antibiotic combination used in hospitals, and there has been increasing data indicating that the combination is associated with increased rates of acute kidney injury (AKI). It is unclear if the dosing method of vancomycin would mitigate the risk of AKI seen with VPT. Objective: To observe and compare incidence of AKI in patients on VPT when using the trough-based dosing method versus the area-under-the-curve (AUC)-based dosing method. Methods: This was a multi-center, retrospective, observational study at 3 community hospitals. Adults receiving at least 48 hours of VPT were included. Patients with severe renal dysfunction, pregnant patients, prisoners, and patients with central nervous system infections, or malignancy were excluded. The primary outcome was incidence of AKI as defined by the Infectious Disease Society of America (IDSA) criteria. Results: A total of 300 patients were included in the study; 150 patients in both the trough and AUC groups. A total of 23 patients (15%) in the trough group and 17 patients (11%) in the AUC group met the primary outcome (odds ratio [OR]: 0.7058, 95% confidence interval [CI]: [0.3603, 1.3826], P = .3098). Conclusion and Relevance: The incidence of AKI was lower in the AUC group compared with the trough group; however, this was not significant. The results of our study suggest that there is no difference between incidence of AKI when using trough- or AUC-based dosing in those receiving VPT. Because of the small sample size and retrospective nature of the study, more data are needed.

12.
Cureus ; 14(4): e23893, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35530902

RESUMO

Purpose For patient comfort and safety, irradiation times should be kept at a minimum while maintaining high treatment quality. In this study of high dose rate (HDR) therapy with a vaginal cylinder, we used the butterfly optimization algorithm (BOA) to simultaneously optimize individual dwell times for precise dose conformity and for the reduction of total dwell time. Material and methods BOA is a population-based, meta-heuristic algorithm that averts local minima by conducting intensive local and global searching based on switching probability. We constructed an objective function (a stimulus intensity function) that consisted of two components. The first one was the root-mean-squared dose error (RMSE) defined as the square root of the sum of squared differences between the prescribed and delivered dose at the constraint points. The second component was weighted total treatment time. Eight previously treated cases were retrospectively reviewed by re-optimizing the clinical treatment plans with BOA.  Results Compared to the eight original plans generated with the commercial adaptive volume optimization algorithm (AVOA), the BOA-optimized plans reduced treatment times by 5.4% to 8.9%, corresponding to a time-saving of 13.1 to 47.7 seconds with the activities on the treatment day and saving from 29.3 to 64.6 seconds if treated with an activity of 5 CI. Dose deviations from the prescription were smaller than in the original plans. Conclusion  Dose optimizations based on the BOA algorithm yield closer dose conformity in vaginal HDR treatment than AVOA. Incorporating total treatment time into the optimization algorithm reduces the delivery time while having only a small effect on dose conformity.

13.
J Pharm Technol ; 37(4): 193-201, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34752572

RESUMO

Background: Data on the use of direct oral anticoagulants in the setting of bioprosthetic valve replacements is limited. Objective: The purpose of this study was to describe outcomes among patients who underwent a bioprosthetic valve replacement and were subsequently prescribed apixaban. Methods: A retrospective cohort study was completed for inpatients at a community hospital who were prescribed apixaban following a bioprosthetic valve replacement from 2015 to 2020. Endpoints assessed included incidence of all-cause readmission and emergency visits within 3 months following valvular surgery, incidence of mortality, and all-cause major and minor bleeding. A post hoc analysis was conducted comparing outcomes among patients who underwent mitral versus aortic valve replacement, as well as patients with and without atrial fibrillation. The study was deemed exempt by hospital and university institutional review boards. Results: A total of 54 patients were included for analysis. All-cause readmission or emergency visit occurred in 33% (n = 18) of patients and the mortality rate was 6% (n = 3). A minor bleeding event was reported in 6% (n = 3) of patients and a major bleeding event was reported in 2% (n = 1) of patients. A thrombotic event was reported in 2% (n = 1) of patients. Conclusion: Within this cohort of patients requiring anticoagulation following bioprosthetic valve replacement, apixaban was safe and well-tolerated. However, more prospective data are needed to further correlate the safety and efficacy of apixaban, particularly in the setting of mitral valve replacement.

14.
J Appl Clin Med Phys ; 22(12): 203-210, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34725909

RESUMO

PURPOSE: To evaluate a two-dimensional diode array for patient-specific quality assurance of VMAT stereotactic radiosurgery (SRS) plans. METHODS: The diode array, an SRS MapCHECK (SRSMC), was composed of a 77 mm ×77 mm face-centered array having a spacing of 2.47 mm. Sixty SRS plans were selected from our clinical database, 30 for treatment of a single target and 30 for multiple targets. The target sizes ranged from 2.4 mm to 44.7 mm equivalent diameter (median 8.7 mm). The plans were delivered to the diode array. For multiple target plans, two measurements were obtained at two locations, one corresponding to the largest target and the other to the smallest target. Gamma using a 3%/1 mm criteria and the dose to the center diode were compared with radiochromic film (RCF). Dose to selected regions of the detector electronics was calculated. RESULTS: The mean difference between the center diode and RCF was -1.2%. For a threshold of at least 95% of detectors/pixels having gamma < 1 for a 3%/1 mm criteria, SRSMC and RCF gave consistent results for 79 of the 90 measurements. For plans with an arc having a patient support angle of 90° or 270°, the median dose to the electronics was 0.65% of the prescription dose. CONCLUSIONS: SRSMC is an efficient tool for accurate patient-specific quality assurance of VMAT single and multiple target radiosurgery, yielding similar clinical decisions as radiochromic film.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
15.
Int J Radiat Oncol Biol Phys ; 111(4): 1058-1065, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34380009

RESUMO

PURPOSE: Verification of patient position through pretreatment setup imaging is crucial in modern radiation therapy. As treatment complexity increases and technology evolves, physicist-physician collaboration becomes imperative for safe and successful radiation delivery. Despite the importance of both, residency programs lack formal interprofessional education (IPE) activities or structured training for image verification. Here we show the impact of an interprofessional image verification workshop for residents in a multi-institutional setting. METHODS: The workshop included a lecture by the attending physicist and physician, and hands-on image registration practice by learners (medical physics residents, MP; and radiation oncology residents, RO). All participants filled out pre- and postactivity surveys and rated their comfort from 1 to 10 in (A) selecting what type of imaging to order for a given case and (B) independently assessing the setup quality based on imaging. A paired 1-tailed t test (α = 0.05) was used to evaluate significance; Spearman rank correlation coefficient was used to assess correlation of ratings and RO postgraduate year (PGY). Surveys had free-response questions about IPE and image verification activities in residency. RESULTS: A total of 71 residents from 7 institutions participated between 2018 and 2020. Pre- and postsurveys were completed by 50 residents (38RO, 12MP) and showed an increase in (A) from 5.5 ± 2.2 to 7.1 ± 1.6 (P < .001) and in (B) from 5.1 ± 2.3 to 6.8 ± 1.5 (P < .001), with significant increases per subgroup (AΔ, RO = 1.8 ± 1.7, P < .001; BΔ, RO = 1.9 ± 1.8, P <. 001; AΔ, MP = 1.1 ± 1.4, P = .012; BΔ, MP = 1.2 ± 1.6, P = .016). RO confidence scores moderately correlated with PGY. Survey responses indicated that image verification training is mostly unstructured, with extent of exposure varying by program and attending; most with little-to-no training. Time constraints were identified as the main barrier. IPE was noted as a useful way to incorporate different perspectives into the process. CONCLUSIONS: Formal image verification training increases resident comfort with setup imaging review and provides opportunities for interprofessional collaboration in radiation oncology residency programs.


Assuntos
Médicos , Competência Clínica , Humanos , Internato e Residência , Física , Inquéritos e Questionários
16.
Cureus ; 13(4): e14695, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-34055539

RESUMO

Purpose To evaluate the accuracy of an augmented reality holographic guidance system for potential use in patient alignment in radiotherapy applications. Methods A cubic phantom was scanned on a CT simulator and a 3D mesh was extracted using the Eclipse Scripting API. An application was created for the Microsoft HoloLens to allow users to see the scanned mesh as a hologram overlaid in the treatment vault. Six therapists were equipped with the HoloLens glasses and instructed to move the real phantom to align with the perceived spatial hologram using only couch controls. The initial couch coordinates were recorded and then recorded at each step as the therapist moved the phantom to each new location. The application varied the position of the virtual phantom to 10 preprogrammed locations within a 40-cm cubic volume in a combination of vertical, longitudinal, and lateral axis shifts. The absolute position difference between the holographic world and real-world phantom was recorded at each step. Also, the relative position from one position to the next was recorded. Results Fifty shifts were collected across the six therapists. The mean difference between the physical position and instructed holographic position was 0.58 ± 0.31 cm for relative shifts and 0.51 ± 0.33 cm for absolute position. The maximum difference between the holographic position and the actual post shift position was 1.53 cm for relative and 1.58 cm for absolute. Conclusion Holographic augmented reality guidance using the Microsoft HoloLens provides adequate accuracy for initial treatment alignment but lacks the fine alignment accuracy of X-ray imaging systems.

17.
Cureus ; 13(4): e14278, 2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-33959456

RESUMO

A procedure is presented to assess performance at non-zero couch angles and perform routine quality assurance (QA) on surface-guided radiotherapy (SGRT) imaging systems used for stereotactic radiosurgery (SRS). A low-cost anthropomorphic phantom was used to assess the system under patient-like conditions. The phantom is embedded with a tungsten ball bearing (BB) to facilitate the use of surface imaging (SI) with concurrent megavoltage (MV) imaging to cross-compare and validate SI-reported offsets. Data analysis is done via in-house software that utilized the SGRT system's log files for automated analysis. This procedure enables users to assess and inter-compare MV-reported offsets with their SGRT system. The analysis provides SGRT system residual error so that users are aware of inherent offsets present in addition to increases in translational offsets due to couch walkout. The procedure was validated with two commercial SGRT systems. The procedure can be used with any surface imaging system and linear accelerator system.

18.
Pract Radiat Oncol ; 11(2): e163-e171, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33632630

RESUMO

PURPOSE: Properly planned single isocenter volumetric modulated arc therapy (VMAT) radiosurgery plans exhibit high quality and efficiency. We report here the largest clinical experience to date, to our knowledge, comparing manual planning with a new automated platform designed to standardize and simplify radiosurgery planning and delivery processes. METHODS: We treated 693 patients with single isocenter VMAT radiosurgical plans generated by either our conventional manual (mVMAT) or a recently implemented automated (HyperArcTM) technique. All plans targeted the gross tumor volume without margin. Radiochromic film was used for patient-specific quality assurance (PSQA). We evaluated local control and toxicity data for a subgroup of 107 patients having 377 metastatic tumors that were treated with HyperArc. RESULTS: The median Radiation Therapy Oncology Group (RTOG) conformity index was 1.14 and was not different between the 2 techniques. The median Paddick gradient index was 5.42 for HyperArc versus 7.09 for mVMAT (P < .001). The median mean brain doses were 4.6% and 5.1% for HyperArc and mVMAT, respectively (P = .04). The PSQA for both techniques met clinical criteria, but 97% of the HyperArc plans satisfied the gamma tolerance limit recommended by the American Association of Physicists in Medicine Task Group No. 218, compared with 94% of the mVMAT plans (P = .02). The median treatment-planning times were not significantly different. The median treatment times were 10.5 and 11.4 minutes for HyperArc and mVMAT, respectively (P < .001). The Kaplan-Meier estimate of local control was 90.1% at 1 year. CONCLUSIONS: HyperArc produces high-quality radiosurgical plans that are at least as good as mVMAT plans created by an expert manual planner with easier planning and more efficient delivery workflow. A less experienced planner can produce very high-quality radiosurgical plans even for patients with more than 10 targets. The use of a single-isocenter technique for multiple targets with no PTV margin did not compromise clinical outcomes, and 1-year local control for treated targets remained congruent with historical series.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
19.
Med Phys ; 48(4): 1461-1468, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33294990

RESUMO

PURPOSE: For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS: DICOM RTdose and RTstructure set files created using MATLAB were imported and evaluated in each of the tools. Each structure set consisted of 50 randomly placed spherical targets. The dose distributions were created on a 1-mm grid using an analytic model such that the dose-volume metrics of the spheres were known. Structure sets were created for 3, 5, 7, 10, 15, and 20 mm diameter spheres. The reported structure volume, V100% [cc], and V50% [cc], and the RTOG conformity index and Paddick Gradient Index, were compared with the analytical values. RESULTS: The average difference and range across all evaluated target sizes for the reported structure volume was - 4.73%[-33.2,0.2], 0.11%[-10.9, 9.5], -0.39%[-12.1, 7.0], -2.24%[-21.0, 1.3], and 1.15%[-15.1,0.8], for TPS-A through TPS-E, respectively. The average difference and range for the V100%[cc] (V20Gy[cc]) was - 0.4[-24.5,9.8], -2.73[-23.6, 1.1], -3.01[-23.6, 0.6], -3.79[-27.3, 1.3], and 0.26[-6.1,2.6] for TPS-A through TPS-E, respectively. For V50%[cc](V10Gy[cc]) in TPS-A through TPS-E the average and ranger were - 0.05[-0.8,0.4], -0.18[-1.2, 0.5], -0.44[-1.4, 0.3], -0.26[-1.8, 2.6], and 0.09[-1.4,2.7]. CONCLUSION: This study expanded on the previously published literature to quantitatively compare the DVH analysis capabilities of software commonly used for SRS plan evaluation and provides freely available and downloadable analytically derived set of ground truth DICOM dose and structure files for the use of radiotherapy clinics. The differences between systems highlight the need for standardization and/or transparency between systems, especially when evaluating plan quality for multi-institutional clinical trials.


Assuntos
Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Software
20.
J Appl Clin Med Phys ; 21(12): 90-95, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33095971

RESUMO

PURPOSE: To report on the use of surface guided imaging during frameless intracranial stereotactic radiotherapy with automated delivery via HyperArcTM (Varian Medical Systems, Palo Alto, CA). METHODS: All patients received intracranial radiotherapy with HyperArcTM and were monitored for intrafraction motion by the AlignRT® (VisionRT, London, UK) surface imaging (SI) system. Immobilization was with the EncompassTM (Qfix, Avondale, PA) aquaplast mask device. AlignRT® log files were correlated with trajectory log files to correlate treatment parameters with SI reported offsets. SI reported offsets were correlated with gantry angle and analyzed for performance issues at non-zero couch angles and during camera-pod blockage during gantry motion. Demographics in the treatment management system were used to identify race and determine if differences in SI reported offsets are due to skin tone settings. RESULTS: A total of 981 fractions were monitored over 14 months and 819 were analyzed. The median AlignRT® reported motion from beginning to the end of treatment was 0.24 mm. The median offset before beam on at non-zero couch angles was 0.55 mm. During gantry motion when camera pods are blocked, the median magnitude was below 1 mm. Median magnitude of offsets at non-zero couch angles was not found to be significantly different for patients stratified by race. CONCLUSIONS: Surface image guidance is a viable alternative to scheduled mid-treatment imaging for monitoring intrafraction motion during stereotactic radiosurgery with automated delivery.


Assuntos
Radiocirurgia , Tomografia Computadorizada de Feixe Cônico , Humanos , Imobilização , Movimento (Física) , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA