Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
EBioMedicine ; 76: 103868, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35172957

RESUMO

BACKGROUND: The manufacturing of any standard mechanical ventilator cannot rapidly be upscaled to several thousand units per week, largely due to supply chain limitations. The aim of this study was to design, verify and perform a pre-clinical evaluation of a mechanical ventilator based on components not required for standard ventilators, and that met the specifications provided by the Medicines and Healthcare Products Regulatory Agency (MHRA) for rapidly-manufactured ventilator systems (RMVS). METHODS: The design utilises closed-loop negative feedback control, with real-time monitoring and alarms. Using a standard test lung, we determined the difference between delivered and target tidal volume (VT) at respiratory rates between 20 and 29 breaths per minute, and the ventilator's ability to deliver consistent VT during continuous operation for >14 days (RMVS specification). Additionally, four anaesthetised domestic pigs (3 male-1 female) were studied before and after lung injury to provide evidence of the ventilator's functionality, and ability to support spontaneous breathing. FINDINGS: Continuous operation lasted 23 days, when the greatest difference between delivered and target VT was 10% at inspiratory flow rates >825 mL/s. In the pre-clinical evaluation, the VT difference was -1 (-90 to 88) mL [mean (LoA)], and positive end-expiratory pressure (PEEP) difference was -2 (-8 to 4) cmH2O. VT delivery being triggered by pressures below PEEP demonstrated spontaneous ventilation support. INTERPRETATION: The mechanical ventilator presented meets the MHRA therapy standards for RMVS and, being based on largely available components, can be manufactured at scale. FUNDING: Work supported by Wellcome/EPSRC Centre for Medical Engineering,King's Together Fund and Oxford University.


Assuntos
Desenho de Equipamento , Respiração Artificial/instrumentação , Animais , COVID-19/patologia , COVID-19/prevenção & controle , COVID-19/virologia , Feminino , Masculino , Taxa Respiratória , SARS-CoV-2/isolamento & purificação , Suínos , Volume de Ventilação Pulmonar
2.
Intensive Care Med Exp ; 9(1): 3, 2021 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-33496887

RESUMO

BACKGROUND: Bedside measurement of lung volume may provide guidance in the personalised setting of respiratory support, especially in patients with the acute respiratory distress syndrome at risk of ventilator-induced lung injury. We propose here a novel operator-independent technique, enabled by a fibre optic oxygen sensor, to quantify the lung volume available for gas exchange. We hypothesised that the continuous measurement of arterial partial pressure of oxygen (PaO2) decline during a breath-holding manoeuvre could be used to estimate lung volume in a single-compartment physiological model of the respiratory system. METHODS: Thirteen pigs with a saline lavage lung injury model and six control pigs were studied under general anaesthesia during mechanical ventilation. Lung volumes were measured by simultaneous PaO2 rate of decline (VPaO2) and whole-lung computed tomography scan (VCT) during apnoea at different positive end-expiratory and end-inspiratory pressures. RESULTS: A total of 146 volume measurements was completed (range 134 to 1869 mL). A linear correlation between VCT and VPaO2 was found both in control (slope = 0.9, R2 = 0.88) and in saline-lavaged pigs (slope = 0.64, R2 = 0.70). The bias from Bland-Altman analysis for the agreement between the VCT and VPaO2 was - 84 mL (limits of agreement ± 301 mL) in control and + 2 mL (LoA ± 406 mL) in saline-lavaged pigs. The concordance for changes in lung volume, quantified with polar plot analysis, was - 4º (LoA ± 19°) in control and - 9° (LoA ± 33°) in saline-lavaged pigs. CONCLUSION: Bedside measurement of PaO2 rate of decline during apnoea is a potential approach for estimation of lung volume changes associated with different levels of airway pressure.

3.
Crit Care Med ; 48(3): e200-e208, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31809278

RESUMO

OBJECTIVES: Determine the intra-tidal regional gas and blood volume distributions at different levels of atelectasis in experimental lung injury. Test the hypotheses that pulmonary aeration and blood volume matching is reduced during inspiration in the setting of minimal tidal recruitment/derecruitment and that this mismatching is an important determinant of hypoxemia. DESIGN: Preclinical study. SETTING: Research laboratory. SUBJECTS: Seven anesthetized pigs 28.7 kg (SD, 2.1 kg). INTERVENTIONS: All animals received a saline-lavage surfactant depletion lung injury model. Positive end-expiratory pressure was varied between 0 and 20 cm H2O to induce different levels of atelectasis. MEASUREMENTS AND MAIN RESULTS: Dynamic dual-energy CT images of a juxtadiaphragmatic slice were obtained, gas and blood volume fractions within three gravitational regions calculated and normalized to lung tissue mass (normalized gas volume and normalized blood volume, respectively). Ventilatory conditions were grouped based upon the fractional atelectatic mass in expiration (< 20%, 20-40%, and ≥ 40%). Tidal recruitment/derecruitment with fractional atelectatic mass in expiration greater than or equal to 40% was less than 7% of lung mass. In this group, inspiration-related increase in normalized gas volume was greater in the nondependent (818 µL/g [95% CI, 729-908 µL/g]) than the dependent region (149 µL/g [120-178 µL/g]). Normalized blood volume decreased in inspiration in the nondependent region (29 µL/g [12-46 µL/g]) and increased in the dependent region (39 µL/g [30-48 µL/g]). Inspiration-related changes in normalized gas volume and normalized blood volume were negatively correlated in fractional atelectatic mass in expiration greater than or equal to 40% and 20-40% groups (r = 0.56 and 0.40), but not in fractional atelectatic mass in expiration less than 20% group (r = 0.01). Both the increase in normalized blood volume in the dependent region and fractional atelectatic mass in expiration negatively correlated with PaO2/FIO2 ratio (ρ = -0.77 and -0.93, respectively). CONCLUSIONS: In experimental atelectasis with minimal tidal recruitment/derecruitment, mechanical inspiratory breaths redistributed blood volume away from well-ventilated areas, worsening PaO2/FIO2.


Assuntos
Lesão Pulmonar/terapia , Respiração com Pressão Positiva/efeitos adversos , Atelectasia Pulmonar/terapia , Circulação Pulmonar/fisiologia , Respiração Artificial/métodos , Algoritmos , Animais , Modelos Animais de Doenças , Mecânica Respiratória , Suínos , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA