Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bone Joint J ; 105-B(8): 912-919, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37524346

RESUMO

Aims: Reverse total shoulder arthroplasty (rTSA) can be used in complex cases when the glenoid requires reconstruction. In this study, a baseplate with composite bone autograft and a central trabecular titanium peg was implanted, and its migration was assessed for two years postoperatively using radiostereometric analysis (RSA). Methods: A total of 14 patients who underwent a rTSA with an autograft consented to participate. Of these, 11 had a primary rTSA using humeral head autograft and three had a revision rTSA with autograft harvested from the iliac crest. The mean age of the patients was 66 years (39 to 81). Tantalum beads were implanted in the scapula around the glenoid. RSA imaging (stereographic radiographs) was undertaken immediately postoperatively and at three, six, 12, and 24 months. Analysis was completed using model-based RSA software. Outcomes were collected preoperatively and at two years postoperatively, including the Oxford Shoulder Score, the American Shoulder and Elbow Score, and a visual analogue score for pain. A Constant score was also obtained for the assessment of strength and range of motion. Results: RSA analysis showed a small increase in all translation and rotational values up to six months postoperatively, consistent with settling of the implant. The mean values plateaued by 12 months, with no evidence of further migration. In four patients, there was significant variation outside the mean, which corresponded to postoperative complications. There was a significant improvement in the clinical and patient-reported outcomes from the preoperative values to those at two years postoperatively (p < 0.001). Conclusion: These findings show, using RSA, that a glenoid baseplate composite of a trabecular titanium peg with autograft stabilizes within the glenoid about 12 months after surgery, and reinforce findings from a previous study of this implant/graft with CT scans at two years postoperatively, indicating that this type of structural composite results in sound early fixation.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Autoenxertos , Análise Radioestereométrica , Titânio , Estudos Prospectivos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Estudos Retrospectivos , Amplitude de Movimento Articular , Resultado do Tratamento , Cavidade Glenoide/cirurgia
2.
J Shoulder Elbow Surg ; 32(10): 2017-2026, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37263477

RESUMO

BACKGROUND: The purpose of this study is to report the clinical and radiologic outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D-printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. METHODS: Following ethical approval, patients were identified and invited to participate. Inclusion criteria were (1) severe glenoid bone loss necessitating the need for custom implants and (2) patients with definitive glenoid and humeral components implanted more than 2 years prior. Included patients underwent clinical assessment using the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and the quick Disabilities of the Arm, Shoulder, and Hand questionnaire (QuickDASH). Radiographic assessment included anteroposterior and axial projections. Patients were invited to attend a computed tomography (CT) scan to confirm osseointegration. Statistical analysis used descriptive statistics (mean and standard deviation [SD]) and paired t test for parametric data. RESULTS: Eleven patients declined to participate. Five patients were deceased prior to study commencement, leaving 42 remaining patients in this analysis. Three patients had revision surgery before the 2-year follow-up; of these, 2 retained their custom glenoid components. Mean follow-up was 31.6 months from surgery (range 24-52 months). All 4 scores improved: OSS from a mean 15 (SD 8.4) to 36 (SD 12) (P < .001), Constant-Murley score from a mean 15 (SD 11.2) to 52 (SD 20.1) (P < .001), QuickDASH from a mean 70 (SD 21) to 31 (SD 24.8) (P = .004), and the ASES score from a mean 22 (SD 17.8) to 71 (SD 23.3) (P = .007). Radiologic evaluation demonstrated good osseointegration in all but 1 included patient. CONCLUSION: The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex cohort. Large complex glenoid bone defects can be managed successfully with custom 3D-printed glenoid components.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Seguimentos , Resultado do Tratamento , Impressão Tridimensional , Estudos Retrospectivos , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Amplitude de Movimento Articular
3.
J Shoulder Elb Arthroplast ; 7: 24715492231172371, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37197294

RESUMO

Background: This study assesses outcomes in revision shoulder replacements where the glenoid bone loss was managed using a structural allograft (donated femoral head) in combination with a trabecular titanium (TT) implant. Methods: We contacted patients who had undergone revision shoulder arthroplasty using the Lima Axioma TT metal-backed glenoid with an allologous bone graft as a composite who were over 2 years since surgery. Patients underwent computerd tomography evaluation, clinical review, and scoring preoperatively, at 6 months and the latest follow-up. Results: Fifteen patients were included with a mean age of 59 (33-76). The average follow-up period was 40.5 months (24-51). 80% showed satisfactory bone graft incorporation and peg integration at the latest follow-up. Three had signs of significant bone graft resorption, although in 2 patients the pegs were still soundly fixed in the host bone. Clinically all patients showed a statistically significant improvement in pain relief, movement, and function. No unusual complications were reported. Conclusion: Results show femoral head structural allograft in combination with TT metal-backed glenoid baseplate is a viable option for revision total shoulder replacement in the context of massive glenoid bone loss. We do, however, acknowledge that this resorption rate is higher than in other reported series where autograft is used.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA