Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Spine J ; 32(8): 2637-2646, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37079079

RESUMO

PURPOSE: Current literature suggests that biportal spinal endoscopy is safe and effective in treating lumbar spine pathology such as lumbar disc herniation, lumbar stenosis, and degenerative spondylolisthesis. No prior study has investigated the postoperative outcomes or complication profile of the technique as a whole. This study serves as the first comprehensive systematic review and meta-analysis of biportal spinal endoscopy in the lumbar spine. METHODS: A PubMed literature search provided over 100 studies. 42 papers were reviewed and 3673 cases were identified with average follow-up time of 12.5 months. Preoperative diagnoses consisted of acute disc herniation (1098), lumbar stenosis (2432), and degenerative spondylolisthesis (229). Demographics, operative details, complications, and perioperative outcome and satisfaction scores were analyzed. RESULTS: Average age was 61.32 years, 48% male. 2402 decompressions, 1056 discectomies, and 261 transforaminal lumbar Interbody fusions (TLIFs) were performed. Surgery was performed on 4376 lumbar levels, with L4-5 being most common(61.3%). 290 total complications occurred, 2.23% durotomies, 1.29% inadequate decompressions, 3.79% epidural hematomas, and < 1% transient nerve root injuries, infections, and iatrogenic instability. Significant improvement in VAS-Back, VAS-Leg, ODI, and Macnab Scores were seen across the cohort. CONCLUSION: Biportal spinal endoscopy is a novel method to address pathology in the lumbar spine with direct visualization through an endoscopic approach. Complications are comparable to previously published rates. Clinical outcomes demonstrate effectiveness. Prospective studies are required to assess the efficacy of the technique as compared to traditional techniques. This study demonstrates that the technique can be successful in the lumbar spine.


Assuntos
Deslocamento do Disco Intervertebral , Fusão Vertebral , Estenose Espinal , Espondilolistese , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Deslocamento do Disco Intervertebral/cirurgia , Espondilolistese/cirurgia , Constrição Patológica , Estenose Espinal/cirurgia , Endoscopia/efeitos adversos , Endoscopia/métodos , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Resultado do Tratamento , Estudos Retrospectivos
2.
Bone Jt Open ; 3(12): 991-997, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36545948

RESUMO

AIMS: Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. METHODS: We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. RESULTS: Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. CONCLUSION: Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation.Cite this article: Bone Jt Open 2022;3(12):991-997.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA