RESUMO
OBJECTIVE: High-frequency, high-resolution transrectal micro-ultrasound (micro-US: ≥15 MHz) imaging of the prostate is emerging as a beneficial tool for scoring disease risk and accurately targeting biopsies. Adding photoacoustic (PA) imaging to visualize abnormal vascularization and accumulation of contrast agents in tumors has potential for guiding focal therapies. In this work, we describe a new imaging platform that combines a transrectal micro-US system with transurethral light delivery for PA imaging. METHODS: A clinical transrectal micro-US system was adapted to acquire PA images synchronous to a tunable laser pulse. A transurethral side-firing optical fiber was developed for light delivery. A polyvinyl chloride (PVC)-plastisol phantom was developed and characterized to image PA contrast agents in wall-less channels. After resolution measurement in water, PA imaging was demonstrated in phantom channels with dyes and biodegradable nanoparticle contrast agents called porphysomes. In vivo imaging of a tumor model was performed, with porphysomes administered intravenously. RESULTS: Photoacoustic imaging data were acquired at 5 Hz, and image reconstruction was performed offline. PA image resolution at a 14-mm depth was 74 and 261 µm in the axial and lateral directions, respectively. The speed of sound in PVC-plastisol was 1383 m/s, and the attenuation was 4 dB/mm at 20 MHz. PA signal from porphysomes was spectrally unmixed from blood signals in the tumor, and a signal increase was observed 3 h after porphysome injection. CONCLUSION: A combined transrectal micro-US and PA imaging system was developed and characterized, and in vivo imaging demonstrated. High-resolution PA imaging may provide valuable additional information for diagnostic and therapeutic applications in the prostate.
Assuntos
Neoplasias , Técnicas Fotoacústicas , Masculino , Humanos , Próstata/diagnóstico por imagem , Meios de Contraste , Ultrassonografia/métodos , Imagens de Fantasmas , Técnicas Fotoacústicas/métodosRESUMO
Superharmonic contrast imaging (SpHI) suppresses tissue clutter and allows high-contrast visualization of the vasculature. An array-based dual-frequency (DF) probe has been developed for SpHI, integrating a 21-MHz, 256-element microultrasound imaging array with a 2-MHz, 32-element array to take advantage of the broadband nonlinear responses from microbubble (MB) contrast agents. In this work, ultrafast imaging with plane waves was implemented for SpHI to increase the acquisition frame rate. Ultrafast imaging was also implemented for microultrasound B-mode imaging (HFPW B-mode) to enable high-resolution visualization of the tissue structure. Coherent compounding was demonstrated in vitro and in vivo in both imaging modes. Acquisition frame rates of 4.5 kHz and 187 Hz in HFPW B-mode imaging were achieved for imaging up to 21 mm with one and 25 angles, respectively, and 3.5 kHz and 396 Hz in the SpHI mode with one and nine coherently compounded angles, respectively. SpHI images showed suppression of tissue clutter prior to and after the introduction of MBs in vitro and in vivo. The nine-angle coherently compounded 2-D SpHI images of contrast-filled flow channel showed a contrast-to-tissue ratio (CTR) of 26.0 dB, a 2.5-dB improvement relative to images reconstructed from 0° steering. Consistent with in vitro imaging, the nine-angle compounded 2-D SpHI of a Lewis lung cancer tumor showed a 2.6-dB improvement in contrast enhancement, relative to 0° steering, and additionally revealed a region of nonviable tissue. The 3-D display of the volumetric SpHI data acquired from a xenograft mouse tumor using both 0° steering and nine-angle compounding allowed the visualization of the tumor vasculature. A small vessel visible in the compounded SpHI image, measuring around [Formula: see text], is not visualized in the 0° steering SpHI image, demonstrating the superiority of the latter in detecting fine structures within the tumor.
Assuntos
Neoplasias , Animais , Camundongos , Imagens de Fantasmas , Ultrassonografia/métodosRESUMO
Ultrasound molecular imaging (USMI) is a technique used to noninvasively estimate the distribution of molecular markers in vivo by imaging microbubble contrast agents (MCAs) that have been modified to target receptors of interest on the vascular endothelium. USMI is especially relevant for preclinical and clinical cancer research and has been used to predict tumor malignancy and response to treatment. In the last decade, methods that improve the resolution of contrast-enhanced ultrasound by an order of magnitude and allow researchers to noninvasively image individual capillaries have emerged. However, these approaches do not translate directly to molecular imaging. In this work, we demonstrate super-resolution visualization of biomarker expression in vivo using superharmonic ultrasound imaging (SpHI) with dual-frequency transducers, targeted contrast agents, and localization microscopy processing. We validate and optimize the proposed method in vitro using concurrent optical and ultrasound microscopy and a microvessel phantom. With the same technique, we perform a proof-of-concept experiment in vivo in a rat fibrosarcoma model and create maps of biomarker expression co-registered with images of microvasculature. From these images, we measure a resolution of 23 µm, a nearly fivefold improvement in resolution compared to previous diffraction-limited molecular imaging studies.
RESUMO
Acoustic angiography is a superharmonic contrast-enhanced ultrasound imaging method that produces high-resolution, 3-D maps of the microvasculature. Previous acoustic angiography studies have used twoelement, annular,mechanicallyactuated transducers(called "wobblers") to image microvasculature in preclinical tumor models with high contrast-to-tissue ratio and resolution, but these earlywobbler transducerscould not achieve the depth and sensitivity required for clinical acoustic angiography. In this work, we present a system for performing acoustic angiography with a novel dual-frequency(DF) transducer-a coaxially stacked DF array (DFA). We evaluate the DFA system bothin vitro andin vivo and demonstrate improvements in sensitivity and imaging depth up to 13.1 dB and 10 mm, respectively, compared with previous wobbler probes.
Assuntos
Angiografia , Meios de Contraste , Acústica , Transdutores , UltrassonografiaRESUMO
Superharmonic imaging with dual-frequency imaging systems uses conventional low-frequency ultrasound transducers on transmit, and high-frequency transducers on receive to detect higher order harmonic signals from microbubble contrast agents, enabling high-contrast imaging while suppressing clutter from background tissues. Current dual-frequency imaging systems for superharmonic imaging have been used for visualizing tumor microvasculature, with single-element transducers for each of the low- and high-frequency components. However, the useful field of view is limited by the fixed focus of single-element transducers, while image frame rates are limited by the mechanical translation of the transducers. In this article, we introduce an array-based dual-frequency transducer, with low-frequency and high-frequency arrays integrated within the probe head, to overcome the limitations of single-channel dual-frequency probes. The purpose of this study is to evaluate the line-by-line high-frequency imaging and superharmonic imaging capabilities of the array-based dual-frequency probe for acoustic angiography applications in vitro and in vivo. We report center frequencies of 1.86 MHz and 20.3 MHz with -6 dB bandwidths of 1.2 MHz (1.2-2.4 MHz) and 14.5 MHz (13.3-27.8 MHz) for the low- and high-frequency arrays, respectively. With the proposed beamforming schemes, excitation pressure was found to range from 336 to 458 kPa at its azimuthal foci. This was sufficient to induce nonlinear scattering from microbubble contrast agents. Specifically, in vitro contrast channel phantom imaging and in vivo xenograft mouse tumor imaging by this probe with superharmonic imaging showed contrast-to-tissue ratio improvements of 17.7 and 16.2 dB, respectively, compared to line-by-line micro-ultrasound B-mode imaging.
Assuntos
Angiografia , Meios de Contraste , Animais , Camundongos , Microbolhas , Imagens de Fantasmas , Transdutores , UltrassonografiaRESUMO
A new photoacoustic (PA) dye was developed as a simple-to-use reagent for creating targeted PA imaging agents. The lead molecule was prepared via an efficient two-step synthesis from an inexpensive commercially available starting material. With the dye's innate albumin-binding properties, the resulting tetrazine-derived dye is capable of localizing to tumor and exhibits a biological half-life of a few hours, allowing for an optimized distribution profile. The presence of tetrazine in turn makes it possible to link the albumin-binding optoacoustic signaling agent to a wide range of targeting molecules. To demonstrate the utility and ease of use of the platform, a novel PA probe for imaging calcium accretion was generated using a single-step bioorthogonal coupling reaction where high-resolution PA images of the knee joint in mice were obtained as early as 1 h post injection. Whole-body distribution was subsequently determined by labeling the probe with 99mTc and performing tissue counting following necropsy. These studies, along with tumor imaging and in vitro albumin binding studies, revealed that the core PA contrast agent can be imaged in vivo and can be easily linked to targeting molecules for organ-specific uptake.
Assuntos
Corantes Fluorescentes/química , Compostos Heterocíclicos com 1 Anel/química , Animais , Linhagem Celular Tumoral , Diagnóstico por Imagem/métodos , Feminino , Compostos Heterocíclicos/química , Humanos , Articulação do Joelho/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Técnicas Fotoacústicas/métodosRESUMO
PURPOSE: Blood-brain barrier disruption (BBBD) is of interest for treating neurodegenerative diseases and tumors by enhancing drug delivery. Focused ultrasound (FUS) is a powerful method to alleviate BBB challenges; however, the detection of BBB opening by non-invasive methods remains limited. The purpose of this work is to demonstrate that 3D transcranial color Doppler (3DCD) and photoacoustic imaging (PAI) combined with custom-made nanoparticle (NP)-mediated FUS delivery can detect BBBD in mice. PROCEDURES: We use MRI and stereotactic ultrasound-mediated BBBD to create and confirm four openings in the left hemisphere and inject intravenously indocyanine green (ICG) and three sizes (40 nm, 100 nm, and 240 nm in diameter) of fluorophore-labeled NPs. We use PAI and fluorescent imaging (FI) to assess the spatial distribution of ICG/NPs in tissues. RESULTS: A reversible 41 ± 12 % (n = 8) decrease in diameter of the left posterior cerebral artery (PCA) relative to the right after FUS treatment is found using CD images. The spectral unmixing of photoacoustic images of the in vivo (2 h post FUS), perfused, and ex vivo brain reveals a consistent distribution pattern of ICG and NPs at *FUS locations. Ex vivo spectrally unmixed photoacoustic images show that the opening width is, on average, 1.18 ± 0.12 mm and spread laterally 0.49 ± 0.05 mm which correlated well with the BBB opening locations on MR images. In vivo PAI confirms a deposit of NPs in tissues for hours and potentially days, is less sensitive to NPs of lower absorbance at a depth greater than 3 mm and too noisy with NPs above an absorbance of 85.4. FI correlates well with ex vivo PAI to a depth of 3 mm in tissues for small NPs and 4.74 mm for large NPs. CONCLUSIONS: 3DCD can monitor BBBD over time by detecting reversible anatomical changes in the PCA. In vivo 3DPAI at 15 MHz combined with circulating ICG and/or NPs with suitable properties can assess BBB opening 2 h post FUS.
Assuntos
Barreira Hematoencefálica/efeitos dos fármacos , Artérias Cerebrais/diagnóstico por imagem , Sistemas de Liberação de Medicamentos , Nanopartículas/química , Técnicas Fotoacústicas , Ultrassonografia Doppler , Animais , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Imageamento Tridimensional , Verde de Indocianina , Imageamento por Ressonância Magnética , Camundongos , Microbolhas , Microscopia de Fluorescência , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Doenças Neurodegenerativas/diagnóstico por imagem , Doenças Neurodegenerativas/terapiaRESUMO
Gas vesicles (GVs) are nanosized structures (45-800 nm) and have been reported to produce non-linear contrast signals, making them an attractive agent for molecular targeting of tumors. One barrier to their use for pre-clinical oncology studies is rapid uptake into the reticuloendothelial system (RES) and consequent rapid decrease in contrast signal after infusion ends and low signal on reperfusion after a bubble burst sequence. The purpose of this study was to examine suppression of the RES and surface modification of GVs to prolong contrast circulation in tumors for ultrasound imaging. Ultrasound imaging to measure dynamics of contrast signal intensity in tumor models was carried out using a 21-MHz high-frequency array transducer with the Vevo 2100 ultrasound system. The non-linear contrast signal from intravenously injected GVs compared with peak enhancement was measured during contrast wash-out and on reperfusion after a contrast burst sequence. Disrupting the RES by saturating the macrophage population or chemically inhibiting the Kupffer cell population with gadolinium or Intralipid preserves 62%-88% of GVs' contrast enhancement relative to peak during the wash-out phase and 32%-56% on reperfusion compared with 38% and 14%, respectively, for no disruption of the RES, indicating longer circulation of GVs in the tumor. Additionally, coating the GVs with 2-, 5- or 10-kDa polyethylene glycol (PEG) chains resulted in >70% contrast signal retention in the tumors during wash-out and, for 5- or 10-kDa PEG chains, a return to >45% of peak contrast signal on reperfusion. These findings indicate that GVs can be used as a contrast agent for tumor imaging and that disruption of the RES improved recirculation and maintained contrast enhancement caused by GVs in the tumors.
Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Gases , Microbolhas , Sistema Fagocitário Mononuclear/metabolismo , Neoplasias/diagnóstico por imagem , Linhagem Celular Tumoral , Humanos , Neoplasias/patologia , Polietilenoglicóis , Ultrassonografia/métodosRESUMO
BACKGROUND: Image-guided surgery has become standard practice during surgical resection, using preoperative magnetic resonance imaging. Intraoperative ultrasound (IoUS) has attracted interest because of its perceived safety, portability, and real-time imaging. This report is a meta-analysis of intraoperative ultrasound in gliomas. METHODS: Critical literature review and meta-analyses, using the MEDLINE/PubMed service. The list of references in each article was double-checked for any missing references. We included all studies that reported the use of ultrasound to guide glioma-surgery. The meta-analyses were conducted according to statistical heterogeneity between the studies using Open MetaAnalyst Software. If there was no heterogeneity, fixed effects model was used for meta-analysis; otherwise, a random effect model was used. Statistical heterogeneity was explored by χ(2) and inconsistency (I(2)) statistics; an I(2) value of 50% or more represented substantial heterogeneity. RESULTS: A wide search yielded 19,109 studies that might be relevant, of which 4819 were ultrasound in neurosurgery; 756 studies used ultrasound in cranial surgery, of which 24 studies used intraoperative ultrasound to guide surgical resection and 74 studies used it to guide biopsy. Fifteen studies fulfilled our stringent inclusion criteria, giving a total of 739 patients. The estimated average gross total resection rate was 77%. Furthermore, the relationship between extent of surgical resection and study population was not linear. Gross total resection was more likely under IoUS when the lesion was solitary and subcortical, with no history of surgery or radiotherapy. IoUS image quality, sensitivity, specificity, and positive and negative predictive values deteriorated as surgical resection proceeded. CONCLUSION: IoUS-guided surgical resection of gliomas is a useful tool for guiding the resection and for improving the extent of resection. IoUS can be used in conjunction with other complementary technologies that can improve anatomic orientation during surgery. Real-time imaging, improved image quality, small probe sizes, repeatability, portability, and relatively low cost make IoUS a realistic, cost-effective tool that complements any existing tools in any neurosurgical operating environment.
Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Glioma/diagnóstico por imagem , Glioma/cirurgia , Procedimentos Neurocirúrgicos/métodos , Bases de Dados Bibliográficas/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética , Monitorização Intraoperatória , UltrassonografiaRESUMO
Image-guided surgery is today considered to be of significant importance in neurosurgical applications. However, one of its major shortcomings is its reliance on preoperative image data, which does not account for brain deformations and displacements that occur during surgery. In this work, we propose to tackle this issue through the incorporation of an ultrasound device within the type of biopsy needles commonly used as an interventional tool to provide immediate feedback to neurosurgeons during surgical procedures. To identify the most appropriate path to access a targeted tissue site, single-element transducers that look either forward or sideways have been designed and fabricated. Micromolded 1-3 piezocomposites were adopted as the active materials for feasibility tests and epoxy lenses have been applied to focus the ultrasound beam. Electrical impedance analysis, pulse-echo testing, and wire phantom scanning have been carried out, demonstrating the functionality of the needle transducers at [Formula: see text]. The capabilities of these transducers for intraoperative image guidance were demonstrated by imaging within soft-embalmed cadaveric human brain and fresh porcine brain.