Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Pers Med ; 13(2)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36836433

RESUMO

Breast cancer patients undergoing neoadjuvant chemotherapy with anthracyclines or trastuzumab can suffer cardiotoxic issues. Nowadays, the markers of cardiac damage are still not reliable, and extracellular volume (ECV) calculated from CT could be a promising cardiotoxic marker. Eighty-two patients, treated with two different chemotherapy regimens based on doxorubicin (DOX) or epirubicin-trastuzumab (EPI-TRAS), were retrospectively selected and the variations in extracellular volume (ECV) values were measured and analyzed. Whole Body CT (WB-CT) scans were acquired after 1 min, in the portal phase (PP), and after 5 min, in the delayed phases (DP), at the baseline (T0), after one year (T1) and after five years (T5) from the end of chemotherapies. The values measured by two radiologists with different levels of experience were evaluated in order to assess the inter-reader reproducibility assessment (ICC = 0.52 for PP and DP). Further, we performed a population-based analysis and a drug-oriented subgroup analysis in 54 DOX-treated and 28 EPI-TRAS-treated patients. In the general cohort of women treated with any of the two drugs, we observed in the lapse T0-T1 a relative increase (RI) of 25% vs. 20% (PP vs. DP, p < 0.001) as well as in the lapse T0-T5 an RI of 17% vs. 15% (PP vs. DP, p < 0.01). The DOX-treated patients reported in the lapse T0-T1 an RI of 22% (p < 0.0001) in PP and an RI of 16% (p = 0.018) in the DP, with ECV values remaining stably high at T5 both in PP (RI 14.0%, p < 0.0001) and in DP (RI 17%, p = 0.005) highlighting a possible hallmark of a persisting CTX sub-damage. On the other hand, ECV measured in EPI-TRAS-treated women showed an RI in T0-T1 of 18% (p = 0.001) and 29% (p = 0.006) in PP and DP, respectively, but the values returned to basal levels in T5 both in the PP (p = 0.12) and in DP setting (p = 0.13), suggesting damage in the first-year post-treatment and a possible recovery over time. For the 82 patients, an echocardiography was performed at T0, T1= 12 m + 3 m and T5 = 60 m + 6 m with LVEF values at T0 (64% ± 5%), T1 (54% ± 6%) and T5 (53% ± 8%). WB-CT-derived ECV values could provide a valid imaging marker for the early diagnosis of cardiotoxic damage in BC patients undergoing oncological treatments. We detected different patterns during the follow-up, with stably high values for DOX, whereas EPI-TRAS showed a peak within the first year, suggesting different mechanisms of cardiac damage.

2.
J Cardiovasc Med (Hagerstown) ; 23(9): 575-588, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994705

RESUMO

Transcatheter procedures for heart valve repair or replacement represent a valid alternative for treating patients who are inoperable or at a high risk for open-heart surgery. The transcatheter approach has become predominant over surgical intervention for aortic valve disease, but it is also increasingly utilized for diseases of the 'other valves', that is the mitral and, to a lesser extent, tricuspid and pulmonary valve. Preprocedural imaging is essential for planning the transcatheter intervention and computed tomography has become the main imaging modality by providing information that can guide the type of treatment and choice of device as well as predict outcome and prevent complications. In particular, preprocedural computed tomography is useful for providing anatomic details and simulating the effects of device implantation using 3D models. Transcatheter mitral valve replacement is indicated for the treatment of mitral regurgitation, either primary or secondary, and computed tomography is crucial for the success of the procedure. It allows evaluating the mitral valve apparatus, the surrounding structures and the left heart chambers, identifying the best access route and the landing zone and myocardial shelf, and predicting obstruction of the left ventricular outflow tract, which is the most frequent postprocedural complication. Tricuspid valve regurgitation with or without stenosis and pulmonary valve stenosis and regurgitation can also be treated using a transcatheter approach. Computer tomography provides information on the tricuspid and pulmonary valve apparatus, the structures that are spatially related to it and may be affected by the procedure, the right heart chambers and the right ventricular outflow tract.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Cateterismo Cardíaco , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
In Vivo ; 36(2): 853-858, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35241542

RESUMO

BACKGROUND/AIM: Despite the popularity of contrast enhanced spectral mammography (CESM), univocal classification of the background parenchymal enhancement (BPE), a bilateral enhancement of the normal breast parenchyma after contrast administration, is lacking. The present study aimed to evaluate the application of BPE Breast Imaging Reporting and Data System Magnetic Resonance (BI-RADS-MR) score for the CESM BPE. Moreover, a pictorial review of four different cases with CESM is provided. PATIENTS AND METHODS: A single-center, retrospective study from a prospectively maintained database of all women undergoing digital mammography (DM) and CESM in our institution between 2016 and 2019. DM and CESM were classified by two experienced radiologists. RESULTS: No statistically significant difference between DM breast density and BPE CESM classification was found. Agreement between readers ranged from substantial to almost perfect. CONCLUSION: BIRADS-RM score for the CESM BPE represents a handy option for radiologists with high inter-reader and DM agreement.


Assuntos
Neoplasias da Mama , Meios de Contraste , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Estudos Retrospectivos
4.
Radiol Case Rep ; 16(12): 3703-3707, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34630805

RESUMO

Infective endocarditis can have peri-annular spread and involve the valvular annulus and adjacent cardiac structures, leading to tissue necrosis and peri-annular abscess. This process may cause pseudoaneurysm formation and other rare and potentially life-threatening complications, so their identification and correct diagnosis are crucial. We describe a case of an 81-year-old woman, with a history of aortic valve replacement and worsening of symptoms, that presents at the imaging a pseudoaneurysm of the aortic root complicated at the same time by 2 life-threatening conditions: fistulization in the Right Ventricular Outflow Tract (RVOT) and the compression of Right Coronary Artery (RCA). This case underlines the importance of imaging, especially Coronary Computed Tomography Angiography (CCTA), in the diagnosis and follow-up of infective endocarditis and its complications, especially in a patient not eligible for surgery.

5.
Am J Case Rep ; 22: e929309, 2021 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-34226439

RESUMO

BACKGROUND Extranodal non-Hodgkin lymphomas (NHL) are low-grade B-cell lymphomas and the breast is not a common site for this condition. This case report describes a 62-year-old woman with a primary NHL and ductal carcinoma in situ (DCIS) of the left breast diagnosed by a magnetic resonance imaging (MRI)-guided vacuum-assisted breast biopsy. The simultaneous diagnosis of breast cancer and NHL is rare, with few cases described in the literature. Primary breast lymphomas account only for 0.04% to 0.5% of breast malignancies. CASE REPORT In November 2016, a 62-year-old woman was treated for a peripheral T-cell lymphoma (follicular helper T-cell phenotype) of the left upper central breast; later she underwent periodic breast imaging follow-ups. In October 2018, MRI revealed a focal 33-mm non-mass contrast enhancement (according to the Breast Imaging Reporting and Data System -MRI lexicon of the American College of Radiology) in the lower external quadrant of the left breast. Neither mammography nor ultrasonography demonstrated any suspicious features. The multidisciplinary medical team performed an MRI-guided vacuum-assisted breast biopsy and the histological analysis confirmed the diagnosis of a DCIS. Subsequently, she underwent surgery resulting in eradication of the disease and has had regular follow-ups, including mammography, ultrasonography, and MRI. CONCLUSIONS This is a rare case of both a primary NHL of the breast and DCIS, which was detected only by MRI. It highlights the role of an MRI-guided vacuum-assisted breast biopsy, which allows an accurate and economic diagnosis in case of suspicious findings on MRI. We recommend the use of MRI in follow-ups for patients with previous breast lymphomas (high-risk patients).


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Linfoma de Células T Periférico , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Feminino , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade
6.
Radiol Case Rep ; 16(7): 1749-1753, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34007396

RESUMO

In this paper, we describe a rare case of coronary artery aneurysms occasionally found on a pre interventional Coronary Computed Tomography Angiography performed on a 67-year-old man with a history of aneurysm of the ascending aorta previously treated with Bentall surgery, who arrived at our hospital to have a percutaneous valve-in-valve implantation procedure. Even though the patient was considered not eligible for the procedure, due to his many comorbidities, and conservatively managed, at 1-year followup his angiographic condition remained stable.

7.
J Med Case Rep ; 14(1): 167, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-32972458

RESUMO

BACKGROUND: An ascending aortic pseudoaneurysm is a severe and rare complication following cardiothoracic surgery. This case report demonstrates its possible misinterpretation and the consequent importance of multidisciplinary evaluation. CASE PRESENTATION: We present a case of an 18-year-old Caucasian man with Marfan syndrome who developed an ascending aortic pseudoaneurysm about 1 year after undergoing cardiac surgery with the Bentall procedure. Computed tomographic examination of the thoracic aorta and positron emission tomography-computed tomography initially suggested a lymphomatous pathology. However, these imaging results were in contrast to the transesophageal echocardiogram and the laboratory data that showed negative results for hematological pathology. A second computed tomographic scan redirected the diagnosis toward a pseudoaneurysm. CONCLUSION: This case demonstrates the utility of close communication and interdisciplinary consultation between cardiovascular radiologists and the cardiac surgery team, which are mandatory in order to maximize their diagnostic skills in identifying postoperative complications.


Assuntos
Falso Aneurisma , Linfoma , Adolescente , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Aorta/diagnóstico por imagem , Erros de Diagnóstico , Humanos , Masculino , Tomografia Computadorizada por Raios X
8.
Anticancer Res ; 40(3): 1719-1729, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32132080

RESUMO

AIM: To assess the ability of ultrasound (US)-guided vacuum-assisted breast excision (VAE) to remove Breast Imaging Reporting and Data System (BI-RADS) ≥3 breast lesions in order to analyze US features most frequently associated with complete excision. MATERIALS AND METHODS: A total of 266 BI-RADS ≥3 lesions without microcalcifications underwent US-VAE. US-VAE and gold standard pathological results were compared. US features of lesions were analyzed. RESULTS: The complete excision rate was 93.61%; the VAE agreement rate was 99.62%. Circumscribed margins, regular shape, parallel orientation, and the absence of posterior features were favorable US features associated with complete excision. Lesions completely excised were: BI-RADS 3 ≤21.10 mm and BI-RADS 4 ≤18.70 mm with one unfavorable US characteristic, and BI-RADS 4 lesions ≤13.5 mm with two unfavorable US features hindered complete removal. Two atypical ductal hyperplasias (<10 mm, one unfavorable feature) and eight ductal carcinomas in situ (≤8.7 mm, one/two unfavorable features) were completely removed. CONCLUSION: US-VAE is highly accurate for diagnostic purpose and, in some cases, highly successful for complete lesion excision. This success also depends on the US characteristics and size of the lesion.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Ultrassonografia Mamária/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
Radiol Case Rep ; 14(8): 1056-1061, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31333807

RESUMO

Urinary collecting system rupture is an uncommon condition that usually occurs with symptoms of acute abdomen, secondary to peritoneal irritation by urine leaking. We report a case of a 49-year-old man admitted to our emergency department because of a worsening deep lower abdominal pain started 3 days before. The abdominal computed tomography revealed urine extravasation suggesting for urinoma. Because of patient pathological history of lymphoma, despite its apparent state of remission, he underwent a positron emission tomography - computed tomography with 18[F]-FDG and magnetic resonance in order to rule out a recurrence. Imaging supported the diagnostic hypothesis of a lymphatic recurrence that had compressed "ab-extrinseco" the urinary tract so much to break it. Based on our experience we can suggest that nontraumatic calyceal-pelvic rupture is an extremely rare manifestation of an onset of lymphoma.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA