Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Gastrointest Oncol ; 13(11): 1781-1790, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34853650

RESUMO

BACKGROUND: Albumin-bound paclitaxel (ABP) has been used as second- and higher-line treatments for advanced esophageal cancer, and its efficacy and safety have been well demonstrated. Lobaplatin (LBP) is a third-generation platinum antitumor agent; compared with the first two generations of platinum agents, it has lower toxicity and has been approved for the treatment of breast cancer, small cell lung cancer, and chronic granulocytic leukemia. However, its role in the treatment of esophageal cancer warrants further investigations. AIM: To investigate the efficacy and safety of induction chemotherapy with ABP plus LBP followed by concurrent radiochemotherapy (RCT) for locally advanced esophageal cancer. METHODS: Patients with pathologically confirmed advanced esophageal squamous cell carcinoma (ESCC) at our hospital were enrolled in this study. All patients were treated with two cycles of induction chemotherapy with ABP plus LBP followed by concurrent RCT: ABP 250 mg/m2, ivgtt, 30 min, d1, every 3 wk; and LBP, 30 mg/m2, ivgtt, 2 h, d1, every 3 wk. A total of four cycles were scheduled. The dose of the concurrent radiotherapy was 56-60 Gy/28-30 fractions, 1.8-2.0 Gy/fraction, and 5 fractions/wk. RESULTS: A total of 29 patients were included, and 26 of them completed the treatment protocol. After the induction chemotherapy, the objective response rate (ORR) was 61.54%, the disease control rate (DCR) was 88.46%, and the progressive disease (PD) rate was 11.54%; after the concurrent RCT, the ORR was 76.92%, the DCR was 88.46%, and the PD rate was 11.54%. The median progression-free survival was 11.1 mo and the median overall survival was 15.83 mo. Cox multivariate analysis revealed that two cycles of induction chemotherapy followed by concurrent RCT significantly reduced the risk of PD compared with two cycles of chemotherapy alone (P = 0.0024). Non-hematologic toxicities were tolerable, and the only grade 3 non-hematologic toxicity was radiation-induced esophagitis (13.79%). The main hematologic toxicity was neutropenia, and no grade 4 adverse event occurred. CONCLUSION: Induction chemotherapy with ABP plus LBP followed by concurrent RCT is effective in patients with locally advanced ESCC, with mild adverse effects. Thus, this protocol is worthy of clinical promotion and application.

2.
World J Clin Cases ; 8(24): 6315-6321, 2020 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-33392312

RESUMO

BACKGROUND: In recent years, neoadjuvant chemoradiotherapy (NCRT) combined with surgery has been gradually applied in patients with locally advanced thoracic esophageal cancer, but its effectiveness and safety remains unclear. In this clinical trial, we prospectively investigated the efficacy and safety of NCRT plus surgery in the treatment of thoracic esophageal squamous cell carcinoma (TESCC). AIM: To investigate the efficacy and safety of NCRT combined with surgery in the treatment of potentially resectable TESCC. METHODS: Thirty patients with advanced TESCC hospitalized in our hospital from July 2016 to June 2019 were prospectively studied. All patients received NCRT, which included intensity modulated conformal radiotherapy (40-44 Gy/20-22f, 2 Gy/f) and chemotherapy (paclitaxel 150-175 mg/m2d1, 22 + lobaplatin 25-30 mg/m2d2, 23 for two cycles). Surgery was performed after radiotherapy and chemotherapy. The effectiveness and safety of these treatments were observed. RESULTS: Among these 30 patients, complete response was achieved in two cases (6.7%) and partial response in 26 cases (86.7%), yielding an objective response rate of 100%. All patients underwent radical surgery successfully. The R0 resection rate was 100%, and the pathologic complete response rate was 33.3%. The incidence of grade III- IV granulocytopenia was 10% during the NCRT, and anastomotic leakage occurred in one patient after surgery. CONCLUSION: For patients with potentially resectable TESCC, NCRT can effectively reduce the tumor size, increase R0 resection rate, and achieve obvious pathological degradation, with mild adverse reactions. Thus, it is worthy of wider clinical application.

3.
Chin Med J (Engl) ; 124(11): 1667-71, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21740774

RESUMO

BACKGROUND: Helical tomotherapy (HT) is a new image-guided intensity-modulated radiation therapy (IMRT) technique. It is reported that HT plan for non-small-cell lung cancer (NSCLC) can give better dose uniformity, dose gradients, and protection for the lung than IMRT plan. We compared the dosimetric characteristics of HT for NSCLC with those of conventional IMRT to observe the superiority of HT. METHODS: There was a comparative case series comprising 10 patients with NSCLC. Computed tomographic (CT) images of delineated targets were transferred to the PrecisePlan planning system (IMRT) and Tomo planning system (HT). The prescription doses were 70 Gy/33F for the gross tumor volume (GTV) and the visible lymph nodes (GTVnd), and 60 Gy/33F for the clinical target volume (CTV) and the clinical target volume of the visible lymph nodes (CTVnd). The dose restrictions for organs at risk were as follows: the maximum dose to spinal cord ≤ 45 Gy, V20 to the total lungs < 30%, V50 to the heart < 50%, and V55 to the esophagus < 50%. Both plans were evaluated by means of the dose coverage of the targets, dose-volume histograms (DVHs), and other dosimetric indices. RESULTS: The dose coverage, conformity, and homogeneity of the targets' volumes were found to be satisfactory in both plans, but the homogeneity of the HT plan was better than that of IMRT. The high-dose radiation volume (V20-V30) to the lung and the mean lung dose (MLD) decreased (P < 0.05), but the low-dose radiation volume (V5-V10) increased slightly in the HT plan (P > 0.05). The maximum doses to the spinal cord, heart, esophagus and trachea in the HT plan were lower than those in the IMRT plan, but the differences were not statistically significant. CONCLUSIONS: The HT plan provids better dose uniformity, dose gradients, and protection for the organs at risk. It can reduce the high-dose radiation volume for lung and the MLD, but may deliver a larger lung volume of low-dose radiation.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Dosagem Radioterapêutica , Resultado do Tratamento
4.
Ai Zheng ; 28(8): 886-9, 2009 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-19664339

RESUMO

BACKGROUND & OBJECTIVE: During the helical tomotherapy process, megavoltage computed tomography (MVCT) images are usually used for guiding the precise setup of patients before/after treatment delivery, which would certainly increase the total dose for patients. This study was to investigate the imaging dose of MVCT using the body and head phantom on a tomotherapy machine. METHODS: A set of cylindrical body and head phantoms was adopted for scanning with different pitch values (1.0/2.0/3.0), lengths (4.8/7.2/9.6/12/14.4 cm) and patient setups on the couch of tomotherapy system. The average MVCT imaging doses were measured using A1SL chambers inserted in the phantoms with preset geometry. The dose uniformity was qualitatively analyzed. RESULTS: The MVCT scanning dose for the body phantom was between 0.599 and 2.876 cGy during each treatment delivery, while the dose for the head phantom was between 0.913 and 3.231 cGy. Two major parameters, the assigned pitch numbers and scanning lengths, were the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. With respect to the scanning length, the doses responded differently along the radial direction of the phantoms with different setup criteria. CONCLUSION: The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra doses to patient.


Assuntos
Imagens de Fantasmas , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Doses de Radiação , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA