Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
3D Print Med ; 10(1): 24, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037479

RESUMO

PURPOSE: Hepatocellular carcinoma (HCC) is one of the most common types of liver cancer that could potentially be surrounded by healthy arteries or veins that a surgeon would have to avoid during treatment. A realistic 3D liver model is an unmet need for HCC preoperative planning. METHODS: This paper presents a method to create a soft phantom model of the human liver with the help of a 3D-printed mold, silicone, ballistic gel, and a blender. RESULTS: For silicone, the elastic modulus of seven different ratios of base silicone and silicone hardener are tested; while for ballistic gel, a model using 20% gelatin and 10% gelatin is created for the tumor and the rest of the liver, respectively. It is found that the silicone modulus of elasticity matches with the real liver modulus of elasticity. It is also found that the 10% gelatin part of the ballistic gel model is an excellent emulation of a healthy human liver. CONCLUSION: The 3D flexible liver phantom made from a 10% gelatin-to-water mixture demonstrates decent fidelity to real liver tissue in terms of texture and elasticity. It holds significant potential for improving medical training, preoperative planning, and surgical research. We believe that continued development and validation of such models could further enhance their utility and impact in the field of hepatobiliary treatment planning and education.

2.
Cancer Med ; 12(13): 14225-14251, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37191030

RESUMO

BACKGROUND: Percutaneous thermal ablation has become the preferred therapeutic treatment option for liver cancers that cannot be resected. Since ablative zone tissue changes over time, it becomes challenging to determine therapy effectiveness over an extended period. Thus, an immediate post-procedural evaluation of the ablation zone is crucial, as it could influence the need for a second-look treatment or follow-up plan. Assessing treatment response immediately after ablation is essential to attain favorable outcomes. This study examines the efficacy of image fusion strategies immediately post-ablation in liver neoplasms to determine therapeutic response. METHODOLOGY: A comprehensive systematic search using PRISMA methodology was conducted using EMBASE, MEDLINE (via PUBMED), and Cochrane Library Central Registry electronic databases to identify articles that assessed the immediate post-ablation response in malignant hepatic tumors with fusion imaging (FI) systems. The data were retrieved on relevant clinical characteristics, including population demographics, pre-intervention clinical history, lesion characteristics, and intervention type. For the outcome metrics, variables such as average fusion time, intervention metrics, technical success rate, ablative safety margin, supplementary ablation rate, technical efficacy rate, LTP rates, and reported complications were extracted. RESULTS: Twenty-two studies were included for review after fulfilling the study eligibility criteria. FI's immediate technical success rate ranged from 81.3% to 100% in 17/22 studies. In 16/22 studies, the ablative safety margin was assessed immediately after ablation. Supplementary ablation was performed in 9 studies following immediate evaluation by FI. In 15/22 studies, the technical effectiveness rates during the first follow-up varied from 89.3% to 100%. CONCLUSION: Based on the studies included, we found that FI can accurately determine the immediate therapeutic response in liver cancer ablation image fusion and could be a feasible intraprocedural tool for determining short-term post-ablation outcomes in unresectable liver neoplasms. There are some technical challenges that limit the widespread adoption of FI techniques. Large-scale randomized trials are warranted to improve on existing protocols. Future research should emphasize improving FI's technological capabilities and clinical applicability to a broader range of tumor types and ablation procedures.


Assuntos
Técnicas de Ablação , Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/cirurgia , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Tomografia Computadorizada por Raios X/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
Comput Biol Med ; 153: 106478, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36603437

RESUMO

Liver Ultrasound (US) or sonography is popularly used because of its real-time output, low-cost, ease-of-use, portability, and non-invasive nature. Segmentation of real-time liver US is essential for diagnosing and analyzing liver conditions (e.g., hepatocellular carcinoma (HCC)), assisting the surgeons/radiologists in therapeutic procedures. In this paper, we propose a method using a modified Pyramid Scene Parsing (PSP) module in tuned neural network backbones to achieve real-time segmentation without compromising the segmentation accuracy. Considering widespread noise in US data and its impact on outcomes, we study the impact of pre-processing and the influence of loss functions on segmentation performance. We have tested our method after annotating a publicly available US dataset containing 2400 images of 8 healthy volunteers (link to the annotated dataset is provided); the results show that the Dense-PSP-UNet model achieves a high Dice coefficient of 0.913±0.024 while delivering a real-time performance of 37 frames per second (FPS).


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador
4.
Sci Rep ; 12(1): 14153, 2022 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-35986015

RESUMO

Segmentation of abdominal Computed Tomography (CT) scan is essential for analyzing, diagnosing, and treating visceral organ diseases (e.g., hepatocellular carcinoma). This paper proposes a novel neural network (Res-PAC-UNet) that employs a fixed-width residual UNet backbone and Pyramid Atrous Convolutions, providing a low disk utilization method for precise liver CT segmentation. The proposed network is trained on medical segmentation decathlon dataset using a modified surface loss function. Additionally, we evaluate its quantitative and qualitative performance; the Res16-PAC-UNet achieves a Dice coefficient of 0.950 ± 0.019 with less than half a million parameters. Alternatively, the Res32-PAC-UNet obtains a Dice coefficient of 0.958 ± 0.015 with an acceptable parameter count of approximately 1.2 million.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos
5.
BMC Med Imaging ; 22(1): 97, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610600

RESUMO

Clinical imaging (e.g., magnetic resonance imaging and computed tomography) is a crucial adjunct for clinicians, aiding in the diagnosis of diseases and planning of appropriate interventions. This is especially true in malignant conditions such as hepatocellular carcinoma (HCC), where image segmentation (such as accurate delineation of liver and tumor) is the preliminary step taken by the clinicians to optimize diagnosis, staging, and treatment planning and intervention (e.g., transplantation, surgical resection, radiotherapy, PVE, embolization, etc). Thus, segmentation methods could potentially impact the diagnosis and treatment outcomes. This paper comprehensively reviews the literature (during the year 2012-2021) for relevant segmentation methods and proposes a broad categorization based on their clinical utility (i.e., surgical and radiological interventions) in HCC. The categorization is based on the parameters such as precision, accuracy, and automation.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
6.
Chem Res Toxicol ; 34(9): 1984-2002, 2021 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-34397218

RESUMO

The inhalation toxicology of multifaceted particulate matter from the environment, cigarette smoke, and e-cigarette liquid vapes is a major research topic concerning the adverse effect of these items on lung tissue. In vitro air-liquid interface (ALI) culture models hold more potential in an inhalation toxicity assessment. Apropos to e-cigarette toxicity, the multiflavor components of the vapes pose a complex experimental bottleneck. While an appropriate ALI setup has been one part of the focus to overcome this, parallel attention towards the development of an ideal exposure system has pushed the field forward. With the advent of microfluidic devices, lung-on-chip (LOC) technologies show enormous opportunities in in vitro smoke-related inhalation toxicity. In this review, we provide a framework, establish a paradigm about smoke-related inhalation toxicity testing in vitro, and give a brief overview of breathing LOC experimental design concepts. The capabilities with optimized bioengineering approaches and microfluidics and their fundamental pros and cons are presented with specific case studies. The LOC model can imitate the structural, functional, and mechanical properties of human alveolar-capillary interface and are more reliable than conventional in vitro models. Finally, we outline current perspective challenges as well as opportunities of future development to smoking lungs-on-chip technologies based on advances in soft robotics, machine learning, and bioengineering.


Assuntos
Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Material Particulado/toxicidade , Produtos do Tabaco/toxicidade , Compostos Orgânicos Voláteis/toxicidade , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Pulmão/citologia , Microfluídica/instrumentação , Robótica
7.
ACS Chem Neurosci ; 12(11): 1835-1853, 2021 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-34008957

RESUMO

The blood-brain barrier (BBB) is a prime focus for clinicians to maintain the homeostatic function in health and deliver the theranostics in brain cancer and number of neurological diseases. The structural hierarchy and in situ biochemical signaling of BBB neurovascular unit have been primary targets to recapitulate into the in vitro modules. The microengineered perfusion systems and development in 3D cellular and organoid culture have given a major thrust to BBB research for neuropharmacology. In this review, we focus on revisiting the nanoparticles based bimolecular engineering to enable them to maneuver, control, target, and deliver the theranostic payloads across cellular BBB as nanorobots or nanobots. Subsequently we provide a brief outline of specific case studies addressing the payload delivery in brain tumor and neurological disorders (e.g., Alzheimer's disease, Parkinson's disease, multiple sclerosis, etc.). In addition, we also address the opportunities and challenges across the nanorobots' development and design. Finally, we address how computationally powered machine learning (ML) tools and artificial intelligence (AI) can be partnered with robotics to predict and design the next generation nanorobots to interact and deliver across the BBB without causing damage, toxicity, or malfunctions. The content of this review could be references to multidisciplinary science to clinicians, roboticists, chemists, and bioengineers involved in cutting-edge pharmaceutical design and BBB research.


Assuntos
Doença de Alzheimer , Nanopartículas , Inteligência Artificial , Transporte Biológico , Barreira Hematoencefálica , Sistemas de Liberação de Medicamentos , Humanos
8.
Int J Comput Assist Radiol Surg ; 14(12): 2165-2176, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31309385

RESUMO

BACKGROUND AND OBJECTIVES: Surgical procedures such as laparoscopic and robotic surgeries are popular since they are invasive in nature and use miniaturized surgical instruments for small incisions. Tracking of the instruments (graspers, needle drivers) and field of view from the stereoscopic camera during surgery could further help the surgeons to remain focussed and reduce the probability of committing any mistakes. Tracking is usually preferred in computerized video surveillance, traffic monitoring, military surveillance system, and vehicle navigation. Despite the numerous efforts over the last few years, object tracking still remains an open research problem, mainly due to motion blur, image noise, lack of image texture, and occlusion. Most of the existing object tracking methods are time-consuming and less accurate when the input video contains high volume of information and more number of instruments. METHODS: This paper presents a variational framework to track the motion of moving objects in surgery videos. The key contributions are as follows: (1) A denoising method using stochastic resonance in maximal overlap discrete wavelet transform is proposed and (2) a robust energy functional based on Bhattacharyya coefficient to match the target region in the first frame of the input sequence with the subsequent frames using a similarity metric is developed. A modified affine transformation-based registration is used to estimate the motion of the features following an active contour-based segmentation method to converge the contour resulted from the registration process. RESULTS AND CONCLUSION: The proposed method has been implemented on publicly available databases; the results are found satisfactory. Overlap index (OI) is used to evaluate the tracking performance, and the maximum OI is found to be 76% and 88% on private data and public data sequences.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Aneurisma Intracraniano/cirurgia , Cirurgia Assistida por Computador/métodos , Algoritmos , Humanos , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA