Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coron Artery Dis ; 32(5): 391-396, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33060529

RESUMO

OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.


Assuntos
Ligas de Cromo/farmacologia , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso , Materiais Biocompatíveis/farmacologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Análise de Sobrevida
2.
Nutr Metab Cardiovasc Dis ; 30(11): 1899-1913, 2020 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-32912793

RESUMO

BACKGROUND AND AIMS: There is poor knowledge on characteristics, comorbidities and laboratory measures associated with risk for adverse outcomes and in-hospital mortality in European Countries. We aimed at identifying baseline characteristics predisposing COVID-19 patients to in-hospital death. METHODS AND RESULTS: Retrospective observational study on 3894 patients with SARS-CoV-2 infection hospitalized from February 19th to May 23rd, 2020 and recruited in 30 clinical centres distributed throughout Italy. Machine learning (random forest)-based and Cox survival analysis. 61.7% of participants were men (median age 67 years), followed up for a median of 13 days. In-hospital mortality exhibited a geographical gradient, Northern Italian regions featuring more than twofold higher death rates as compared to Central/Southern areas (15.6% vs 6.4%, respectively). Machine learning analysis revealed that the most important features in death classification were impaired renal function, elevated C reactive protein and advanced age. These findings were confirmed by multivariable Cox survival analysis (hazard ratio (HR): 8.2; 95% confidence interval (CI) 4.6-14.7 for age ≥85 vs 18-44 y); HR = 4.7; 2.9-7.7 for estimated glomerular filtration rate levels <15 vs ≥ 90 mL/min/1.73 m2; HR = 2.3; 1.5-3.6 for C-reactive protein levels ≥10 vs ≤ 3 mg/L). No relation was found with obesity, tobacco use, cardiovascular disease and related-comorbidities. The associations between these variables and mortality were substantially homogenous across all sub-groups analyses. CONCLUSIONS: Impaired renal function, elevated C-reactive protein and advanced age were major predictors of in-hospital death in a large cohort of unselected patients with COVID-19, admitted to 30 different clinical centres all over Italy.


Assuntos
Betacoronavirus , Doenças Cardiovasculares/etiologia , Infecções por Coronavirus/mortalidade , Mortalidade Hospitalar , Aprendizado de Máquina , Pneumonia Viral/mortalidade , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Proteína C-Reativa/análise , COVID-19 , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Análise de Sobrevida , Adulto Jovem
3.
BMJ Case Rep ; 20102010 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-22778110

RESUMO

Iatrogenic pseudoaneurysms of the brachial artery are rare complications of haemodialysis access procedures and can lead to substantial morbidity and mortality if not managed promptly; however, surgery is also associated with the potential risk of severe complications. We describe the clinical and radiological findings relating to a dialysed patient who developed a huge iatrogenic pseudoaneurysm of the brachial artery (due to an inadvertent artery puncture), which was successfully treated by means of the percutaneous implantation of a polytetrafluoroethylene (PTFE)-covered stent.


Assuntos
Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Procedimentos Endovasculares/métodos , Doença Iatrogênica , Stents , Dispositivos de Acesso Vascular/efeitos adversos , Idoso , Falso Aneurisma/diagnóstico por imagem , Artéria Braquial , Seguimentos , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Masculino , Radiografia , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Medição de Risco , Resultado do Tratamento
5.
Am J Cardiol ; 97(4): 489-93, 2006 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-16461043

RESUMO

The Ultegra Rapid Platelet Function Assay was used to measure the inhibition of platelet aggregation at baseline and 10 minutes and 8 hours after starting therapy in 114 patients undergoing high-risk percutaneous coronary intervention with the planned use of a glycoprotein IIb/IIIa inhibitor. The abciximab-treated patients received a 0.25 mg/kg bolus, followed by a 0.125 microg/kg/min infusion for 12 hours; the eptifibatide-treated patients received 2 boluses of 180 microg/kg administered 10 minutes apart, followed by a 2 microg/kg/min infusion for 24 hours; the tirofiban-treated patients received a 25 microg/kg bolus, followed by a 0.15 microg/kg/min infusion for 18 hours. Ten minutes after starting therapy, the mean level of platelet inhibition was 86 +/- 9% for abciximab, 92 +/- 6% for eptifibatide, and 95 +/- 5% for tirofiban (p <0.001); > or =95% platelet inhibition was achieved in 29% of the patients treated with abciximab, 44% of those receiving eptifibatide, and 68% of the those receiving tirofiban (p = 0.02). In conclusion, at the evaluated doses, tirofiban seemed to be the most effective drug in achieving "optimal" platelet inhibition very early after percutaneous coronary intervention.


Assuntos
Angioplastia Coronária com Balão , Anticorpos Monoclonais/administração & dosagem , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Peptídeos/administração & dosagem , Agregação Plaquetária/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Complexo Glicoproteico GPIb-IX de Plaquetas/antagonistas & inibidores , Glicoproteínas da Membrana de Plaquetas/antagonistas & inibidores , Tirosina/análogos & derivados , Abciximab , Idoso , Eptifibatida , Feminino , Humanos , Masculino , Tirofibana , Tirosina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA