Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Colloids Surf B Biointerfaces ; 212: 112342, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35085937

RESUMO

Biodegradable magnesium (Mg) based implants have considerable interest in the biomedical field as their use nullifies the necessity for implant removal surgery and avoids the long-standing adverse reaction of permanent bioimplants. The degradation resistance and biocompatibility of the Mg alloys can be improved by coating them with a suitable thin film. Here, thin films of niobium and niobium oxide were developed on the AZ31B Mg alloy by sputtering technique and their biocompatibility and corrosion resistance was examined. X-ray diffraction (XRD) and Transmission electron microscope (TEM) techniques confirmed the crystallinity of the thin films. Subsequently, scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) techniques were employed to evaluate the morphology and chemical composition of the thin film surfaces, respectively. Thin-film coated Mg alloys revealed good corrosion resistance compared to their uncoated bare counterparts in simulated body fluid (SBF). The contact angle study was performed on the coated specimens to investigate their wettability which revealed their hydrophobic character. The cell viability studies on thin-film coated specimens exhibited significant cell proliferation, and cell morphological studies showed good cell attachment and growth. The in vitro MTT assay on mouse osteoblast precursor cells (MC3T3-E1) indicated that the Nb-based coatings are cytocompatible and promote cell proliferation.


Assuntos
Implantes Absorvíveis , Nióbio , Ligas/química , Ligas/farmacologia , Animais , Materiais Revestidos Biocompatíveis/química , Corrosão , Teste de Materiais , Camundongos , Nióbio/química , Óxidos
2.
Nanomedicine ; 18: 157-168, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30844575

RESUMO

Two distinct surface topographies consisting of micro- and nano-surface were developed using laser texturing (LT) and anodization process respectively and their effect on the surface-related properties of Ti-6Al-4V fabricated using Laser Engineered Net Shaping (LENS) were determined. The topographies developed using laser texturing (25, 50 and 75% overlap) were examined using 3D profilometer, whereas, Field Emission Scanning Electron Microscopy (FE-SEM) was used to analyze Titania NanoTubes (TNT) formed using anodization. Though all the surface modified specimens exhibited hydrophilic behavior, least contact angle values were observed for the specimen surface modified with TNT. 25LT and 50LT specimens offered about 8 fold higher corrosion resistance than TNT specimens. All the surface modified samples exhibited non-toxicity to blood cells as well as to the mesenchymal stem cells (hMSCs) with a higher rate of proliferation and differentiation hMSCs observed on 75LT specimens and TNT specimen.


Assuntos
Lasers , Teste de Materiais , Nanopartículas/química , Ortopedia/métodos , Titânio/química , Adulto , Fosfatase Alcalina/metabolismo , Ligas , Espectroscopia Dielétrica , Técnicas Eletroquímicas , Dureza , Hemólise/efeitos dos fármacos , Humanos , Masculino , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/enzimologia , Células-Tronco Mesenquimais/ultraestrutura , Nanopartículas/ultraestrutura , Propriedades de Superfície , Titânio/farmacologia
3.
J Biomed Mater Res B Appl Biomater ; 106(2): 569-577, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28245086

RESUMO

Medical grade 316L stainless steel was laser surface melted (LSM) using continuous wave Nd-YAG laser in argon atmosphere at 1 and 5 mm/s. The treated surfaces were characterized using electron backscatter diffraction to study the influence of top surface crystallographic orientation and type of grain boundaries on corrosion resistance, wettability, and biocompatibility. The laser scan velocity was found to have a marginal influence on the surface roughness and the type of grain boundaries. However, the crystal orientation density was found to be relatively high in 1 mm/s samples. The LSM samples showed a higher concentration of {101} and {123} planes parallel to the sample surface as well as a higher fraction of low-angle grain boundaries. The LSM samples were found to exhibit better surface wettability and enhanced the viability and proliferation of human fetal osteoblast cells in vitro when compared to the untreated samples. Further, the corrosion protection efficiency of 316L stainless steel was improved up to 70% by LSM in as-processed condition. The increased concentration of {101} and {123} planes on surfaces of LSM samples increases their surface energy, which is believed to be responsible for the improved in vitro cell proliferation. Further, the increased lattice spacing of these planes and high concentration of low-energy grain boundaries in LSM samples would have contributed to the better in vitro corrosion resistance than untreated 316L stainless steel. Our results indicate that LSM can be a potential treatment option for 316L stainless steel-based biomedical devices to improve biocompatibility and corrosion resistance. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 569-577, 2018.


Assuntos
Lasers , Teste de Materiais , Aço Inoxidável/química , Aço Inoxidável/farmacologia , Molhabilidade , Argônio/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Corrosão , Humanos , Soluções Isotônicas/química , Soluções Isotônicas/farmacologia , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Água/química
4.
J Mech Behav Biomed Mater ; 65: 584-599, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27721175

RESUMO

AISI 316L is a well known biocompatible, austenitic stainless steel (SS). It is thus a bio-steel. Considering its importance as a bio-prosthesis material here we report the plasma nitriding of AISI 316L (SS) followed by its microstructural and nanotribological characterization. Plasma nitriding of the SS samples was carried out in a plasma reactor with a hot wall vacuum chamber. For ease of comparison these plasma nitrided samples were termed as SSPN. The experimental results confirmed the formations of an embedded nitrided metal layer zone (ENMLZ) and an interface zone (IZ) between the ENMLZ and the unnitrided bulk metallic layer zone (BMLZ) in the SSPN sample. These ENMLZ and IZ in the SSPN sample were richer in iron nitride (FeN) chromium nitride (CrN) along with the austenite phase. The results from nanoindentation, microscratch, nanoscratch and sliding wear studies confirmed that the static contact deformation resistance, the microwear, nanowear and sliding wear resistance of the SSPN samples were much better than those of the SS samples. These results were explained in terms of structure-property correlations.


Assuntos
Materiais Biocompatíveis/análise , Teste de Materiais , Aço Inoxidável/análise , Gases em Plasma
5.
Mater Sci Eng C Mater Biol Appl ; 39: 336-9, 2014 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-24863233

RESUMO

The aim of the present work is to chemically and physically characterize the synthesized Hydroxyapatite (HAp) micro and nanoparticles and to explore the inhibitory effect of nano-HAps on the in vitro growth of human colon cancerous cells HCT116. HAp powder was synthesized using three different routes to achieve micro and nanosized powders, with different morphologies and crystallinity. The synthesized powders were characterized using X-ray diffraction, FTIR spectroscopy and scanning electron microscope. The results showed that the average crystallite size of HAp powder varies from 11nm to 177nm and respective crystallinity of powder found to be in the range of 0.12 and 0.92. The effect of these physico-chemical properties of HAp powders on human colon cancer HCT116 cells inhibition was determined in vitro. It was found that decreasing the HAp powder crystallite size between 11nm and 22nm significantly increases the HCT116 cell inhibition. Our results demonstrate that apart from HAp powder size their crystallinity and morphology also play an important role in cellular inhibition of human colon cancer cells.


Assuntos
Materiais Biocompatíveis/química , Proliferação de Células/efeitos dos fármacos , Cristalização , Durapatita/química , Células HCT116 , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Nanopartículas/química , Tamanho da Partícula , Pós/química , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
6.
Mater Sci Eng C Mater Biol Appl ; 33(8): 4594-8, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24094165

RESUMO

Laser-engineered net shaping (LENS™), a commercial additive manufacturing process, was used to modify the surfaces of 316 L stainless steel with bioactive hydroxyapatite (HAP). The modified surfaces were characterized in terms of their microstructure, hardness and apatite forming ability. The results showed that with increase in laser energy input from 32 J/mm(2) to 59 J/mm(2) the thickness of the modified surface increased from 222±12 µm to 355±6 µm, while the average surface hardness decreased marginally from 403±18 HV0.3 to 372±8 HV0.3. Microstructural studies showed that the modified surface consisted of austenite dendrites with HAP and some reaction products primarily occurring in the inter-dendritic regions. Finally, the surface-modified 316 L samples immersed in simulated body fluids showed significantly higher apatite precipitation compared to unmodified 316 L samples.


Assuntos
Materiais Biocompatíveis/química , Durapatita/química , Lasers , Aço Inoxidável/química , Dureza , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA