Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Ann Thorac Surg ; 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38802036

RESUMO

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) provides detailed understanding on pediatric patients supported with ventricular assist devices (VADs). We sought to identify important variables affecting the incidence of stroke in pediatric VADs. METHODS: Between 2012 and 2022, 1463 devices in 1219 patients were reported to Pedimacs from 40 centers in patients aged <19 years at their first VAD implantation. Multiphase parametric hazard modeling was used to identify risk factors for stroke among all device types. RESULTS: Of the 1219 patients, the most common devices were implantable continuous (472 [39%]), followed by paracorporeal pulsatile (342 [28%]), and paracorporeal continuous (327 [27%]). Overall freedom from stroke at 6 months was higher in the recent era (2012-2016; 80.2% [95% CI, 77.1%-82.9%] vs 2017-2023; 87.9% [95% CI, 86.2%-89.4%], P = .009). Implantable continuous VADs had the highest freedom from stroke at 3 months (92.7%; 95% CI, 91.1%-93.9%) and 6 months (91.1%; 95% CI, 89.3%-92.6%), followed by paracorporeal pulsatile (87.0% [95% CI, 84.8%-88.9%] and 82.8% [95% CI, 79.8%-85.5%], respectively), and paracorporeal continuous (76.0% [95% CI, 71.8%-79.5%] and 69.5% [95% CI, 63.4%-74.8%], respectively) VADs. Parametric modeling identified risk factors for stoke early after implant and later. Overall, and particularly for paracorporeal pulsatile devices, early stroke risk has decreased in the most recent era (hazard ratio, 5.01). Among implantable continuous devices, cardiogenic shock was the major risk factor. For patients <10 kg, early hazard was only seen in the previous era. For congenital patients, early hazard was seen in nonimplantable device use and use of extracorporeal membrane oxygenation. CONCLUSIONS: The overall stroke rate has decreased from 20% to 15% at 6 months, with particular improvement among paracorporeal pulsatile devices. Risk factor analyses offer insights for identification of higher stroke risk subsets and further management refinements.

2.
Eye (Lond) ; 38(4): 680-686, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38302533

RESUMO

BACKGROUND/OBJECTIVES: A national study was undertaken through the British ophthalmology surveillance unit (BOSU) to determine the incidence, presenting features and management of essential infantile esotropia (EIE) in the UK. METHODS: Data from a prospective national observational study of newly diagnosed EIE presenting to clinicians in the United Kingdom over a 12-month period were collected. Cases with a confirmed diagnosis by a clinician of a constant, non-accommodative esotropia ≥20 prism dioptres (PD), presenting at ≤12 months, with no neurological or ocular abnormalities were identified through BOSU. Follow-up data were collected at 12 months. RESULTS: A total of 57 cases were reported giving an incidence of EIE of 1 in 12,828 live births. The mean age of diagnosis and intervention were 7.05 ± 2.6 months (range 2-12) and 14.7 ± 4.9 months (range 6.5-28.1), respectively. Management was surgical in 59.6%, botulinum toxin alone in 22.8%, and 17.5% were observed. The preoperative angle of esotropia was smaller in the observation group (P = 0.04). The postoperative angle of esotropia was not statistically significant between botulinum toxin or surgery (P = 0.3), although the age of intervention was earlier in the botulinum group (P = 0.007). Early intervention (before 12 months of age) did not influence the post-intervention motor outcomes between 0 and 10 prism dioptres of esotropia (P = 0.78). CONCLUSIONS: The incidence of EIE in the UK is considerably lower than reported in other population-based studies. The preferred method of treatment was surgical with earlier intervention in those treated with botulinum toxin. An early age of intervention (<12 months) did not influence motor outcomes.


Assuntos
Toxinas Botulínicas Tipo A , Esotropia , Oftalmologia , Humanos , Lactente , Esotropia/diagnóstico , Esotropia/epidemiologia , Esotropia/terapia , Toxinas Botulínicas Tipo A/uso terapêutico , Incidência , Estudos Prospectivos , Visão Binocular , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Resultado do Tratamento , Reino Unido/epidemiologia , Estudos Retrospectivos
3.
Ann Thorac Surg ; 117(4): 690-703, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38123046

RESUMO

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), supported by The Society of Thoracic Surgeons, provides detailed information on pediatric patients supported with ventricular assist devices (VADs). METHODS: From September 19, 2012, to December 31, 2022, 1463 devices in 1219 patients aged <19 years were reported to the registry from 40 North American hospitals. RESULTS: Cardiomyopathy remains the most common underlying etiology (59%), followed by congenital heart disease (26%) and myocarditis (8%). Implantable continuous devices were most common (39%) type, followed by paracorporeal pulsatile (28%) and paracorporeal continuous (27%) devices. At 6 months after VAD implantation, a favorable outcome (transplant, recovery, or alive on device) was achieved in 85% of patients, which was greatest among those on implantable continuous VADs (92%) and least for paracorporeal continuous VADs (68%), although the patient population supported on these devices is different. CONCLUSIONS: This Seventh Pedimacs Report demonstrates the continued importance of VADs in the treatment of children. With the complexity of cardiac physiologies and sizes of patients, multiple types of devices are used, including paracorporeal continuous, paracorporeal pulsatile, and implantable continuous devices. The preoperative risk factors and differences in patient populations may account for some of the differences in survival observed among these devices. This report, along with other collaborative work, continues to advance the care of this challenging and vulnerable population.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Cirurgiões , Criança , Humanos , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento , Sistema de Registros , Estudos Retrospectivos
4.
Ann Thorac Surg ; 116(5): 972-979, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37573991

RESUMO

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) provides detailed understanding on pediatric patients supported with ventricular assist devices (VADs). We sought to identify important variables affecting mortality in pediatric VADs. METHODS: Patients aged <19 years, from 2012 to 2021, were included. Survival analyses were performed using Kaplan-Meier. Parametric hazard modeling was used to identify risk factors for death. RESULTS: Of the 1109 patients, the most common devices were implantable continuous (IC, 448 [40%]), followed by paracorporeal pulsatile (PP, 306 [28%]), paracorporeal continuous (PC, 293 [26%]), and percutaneous (58 [5%]). Patients with percutaneous device, infants, congenital heart disease, biventricular support, and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 had worse overall survival at 6 months. Positive outcome was 83% at 6 months. Consistent with their cohort composition, device type positive outcomes at 6 months were IC, 92%; PP, 84%; and PC, 69%. Parametric hazard modeling for overall survival showed an early hazard for death with biventricular support, congenital heart disease (CHD), intubation before implantation, PC device, and renal impairment, whereas a constant hazard was associated with ascites. For patients <10 kg, parametric modeling showed an early hazard for CHD, intubation, and renal impairment. Modeling in CHD patients showed an early hazard for biventricular support, renal impairment, and use of PC/PP devices. CONCLUSIONS: This multivariable analysis of the complete Pedimacs database demonstrates that illness at VAD implantation, diagnosis, and strategy of support affect survival and differ by device type. We hope this is the first step in creating a predictive tool to help providers and families have informed expectations.

5.
World J Pediatr Congenit Heart Surg ; 14(4): 530-532, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37192747

RESUMO

We report a case of symptomatic myocardial bridge in an adolescent with dynamic right ventricular outflow tract obstruction and history of congenital pulmonary valve stenosis as well as hypertrophic cardiomyopathy. Definitive treatment was surgical infundibular myectomy and coronary unroofing, resulting in improvement in right ventricular outflow tract gradient and ischemic symptoms.


Assuntos
Cardiomiopatia Hipertrófica , Obstrução da Via de Saída Ventricular Direita , Obstrução do Fluxo Ventricular Externo , Humanos , Adolescente , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Miocárdio , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia
6.
J Thorac Cardiovasc Surg ; 165(2): 431-433, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36008182
7.
Ann Thorac Surg ; 115(5): 1098-1108, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36402175

RESUMO

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), supported by The Society of Thoracic Surgeons, provides detailed information on pediatric patients supported with ventricular assist devices (VADs). METHODS: From September 19, 2012, to December 31, 2021, there were 1355 devices in 1109 patients (<19 years) from 42 North American Hospitals. RESULTS: Cardiomyopathy was the most common underlying cause (59%), followed by congenital heart disease (25%) and myocarditis (9%). Regarding device type, implantable continuous (IC) VADs were most common at 40%, followed by paracorporeal pulsatile (PP; 28%) and paracorporeal continuous (PC; 26%). Baseline demographics differed, with the PC cohort being younger, smaller, more complex (ie, congenital heart disease), and sicker at implantation (P < .0001). At 6 months after VAD implantation, a favorable outcome (transplantation, recovery, or alive on device) was achieved in 84% of patients, which was greatest among those on IC VADs (92%) and least for PC VADs (69%). Adverse events were not uncommon, with nongastrointestinal bleeding (incidence of 14%) and neurologic dysfunction (11% [stroke, 4%]), within 2 weeks after implantation being the most prevalent. Stroke and bleeding had negative impacts on overall survival (P = .002 and P < .001, respectively). CONCLUSIONS: This Sixth Pedimacs Report demonstrates the continued evolution of the pediatric field. The complexity of cardiac physiologies and anatomic constraint mandates the need for multiple types of devices used (PC, PP, IC). Detailed analyses of each device type in this report provide valuable information to further advance the care of this challenging and vulnerable population.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Cirurgiões , Criança , Humanos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Cardiopatias Congênitas/etiologia , Sistema de Registros , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos
10.
Ann Thorac Surg ; 113(3): 1026-1035, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34826386

RESUMO

BACKGROUND: Research evaluating hemostatic agents for the treatment of clinically significant bleeding has been hampered by inconsistency and lack of standardized primary clinical trial outcomes. Clinical trials of hemostatic agents in both cardiac surgery and mechanical circulatory support, such as extracorporeal membrane oxygenation and ventricular assist devices, are examples of studies that lack implementation of universally accepted outcomes. METHODS: A subgroup of experts convened by the National Heart, Lung, and Blood Institute and the US Department of Defense developed consensus recommendations for primary outcomes in cardiac surgery and mechanical circulatory support. RESULTS: For cardiac surgery the primary efficacy endpoint of total allogeneic blood products (units vs mL/kg for pediatric patients) administered intraoperatively and postoperatively through day 5 or hospital discharge is recommended. For mechanical circulatory support outside the perioperative period the recommended primary outcome for extracorporeal membrane oxygenation is a 5-point ordinal score of thrombosis and bleeding severity adapted from the Common Terminology Criteria for Adverse Events version 5.0. The recommended primary endpoint for ventricular assist device is freedom from disabling stroke (Common Terminology Criteria for Adverse Events AE ≥ grade 3) through day 180. CONCLUSIONS: The proposed composite risk scores could impact the design of upcoming clinical trials and enable comparability of future investigations. Harmonizing and disseminating global consensus definitions and management guidelines can also reduce patient heterogeneity that would confound standardized primary outcomes in future research.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Hemostáticos , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemostasia , Humanos , Resultado do Tratamento
11.
Ann Thorac Surg ; 112(6): 1763-1774, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34648810

RESUMO

BACKGROUND: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs) provides detailed information on pediatric patients supported with ventricular assist devices (VADs). METHODS: From September 19, 2012, to December 31, 2020, 1229 devices in 1011 patients were reported to the registry from 47 North American Hospitals in patients aged younger than 19 years. RESULTS: Cardiomyopathy was the most common underlying etiology (58%), followed by congenital heart disease (CHD; 25%) and myocarditis (10%). The most common devices implanted were implantable continuous (IC; 419 [41%]), followed by paracorporeal pulsatile (PP; 269 [27%]), paracorporeal continuous (PC; 263 [26%]), and percutaneous (53 [5%]). Overall, at 6 months after VAD implantation, 83% had a positive outcome (transplant, explant, or alive on device). The freedom from stroke at 3 months was highest in IC VADs (93%), compared with PP VADs (84%) and with PC VADs (75%). There were differences in survival by device type, with patients on IC VADs having the best overall survival and those on PC having the lowest overall survival, though the patient populations being supported by each VAD type differed significantly from each other. CONCLUSIONS: This Fifth Pedimacs Report demonstrates the continued robust growth of VADs in the pediatric community, now with more than 1000 patients reported to the registry. The multiple available device types (PC, PP, IC) serve different populations with different pre-VAD risk profiles, which may account for differences in survival and adverse events between device types.


Assuntos
Cardiopatias Congênitas/terapia , Coração Auxiliar/estatística & dados numéricos , Sistema de Registros , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos
12.
Ann Thorac Surg ; 112(3): e185-e188, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33482162

RESUMO

Mechanical support of patients with superior cavopulmonary connection is challenging; multiple factors contribute to failure: elevated pulmonary vascular resistance, aortopulmonary collateral flow, venovenous collaterals, ventricular dysfunction, and atrioventricular valve regurgitation. We report 2 cases of conversion from a single ventricle circulation to biventricular mechanical support by reestablishing caval continuity. Both patients have demonstrated recovery of end-organ function and participation in rehabilitation. This method of support results in improved systemic venous pressures and pulmonary blood flow compared with systemic mechanical circulatory support with a cavopulmonary connection and transfers some of the complexity of the transplant to the ventricular assist device implant.


Assuntos
Técnica de Fontan , Insuficiência Cardíaca/terapia , Coração Auxiliar , Complicações Pós-Operatórias/terapia , Pré-Escolar , Feminino , Humanos , Lactente , Masculino
13.
Pediatr Cardiol ; 41(6): 1115-1124, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32388668

RESUMO

Elective closure of atrial septal defect (ASD) is usually recommended during preschool ages. However, ASD may contribute to deteriorating health in the presence of significant comorbidity and, thus, may need earlier closure. There is a lack of clarity regarding the indications for and outcomes after ASD closure in infancy and early childhood. We investigated the benefits and safety of surgical ASD closure in symptomatic patients under 2 years of age. Retrospective chart review was conducted in patients who underwent surgical ASD closure within the first 2 years of life. Of 31 symptomatic ASD patients, 22 had persistent respiratory symptoms, 24 failure to thrive, and 9 pulmonary hypertension. Overall, 26 patients (84.0%) showed clinical improvement after ASD closure, including improved respiratory status (17/22; 77.3%), resumption of normal growth (15/24; 62.5%), and resolution of pulmonary hypertension (7/7; 100%, 2 patients unable to assess postoperatively). Two medically complicated patients died a few months after surgery unrelated to surgical complications. Four out of 8 ventilator-dependent patients were weaned from mechanical ventilation within 1 month after ASD closure. Closure of ASD did not improve those patients with highly advanced lung disease and/or medically complex conditions including underlying genetic abnormalities. Surgical complications were uncommon. Postoperative hospital stay was 4 to 298 days (median 8 days). The majority of our patients demonstrated significant clinical improvement after ASD closure. Early ASD closure is safe and beneficial for symptomatic infants and young children with associated underlying pulmonary abnormalities, especially bronchopulmonary dysplasia.


Assuntos
Comunicação Interatrial/cirurgia , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/fisiopatologia , Cateterismo Cardíaco/métodos , Pré-Escolar , Feminino , Comunicação Interatrial/complicações , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Lactente , Tempo de Internação , Masculino , Estudos Retrospectivos , Resultado do Tratamento
15.
J Thorac Cardiovasc Surg ; 160(5): 1301-1308.e2, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31948738

RESUMO

OBJECTIVE: Patients with biventricular assist devices (BiVADs) have worse outcomes than those with left ventricular assist devices (LVADs). It is unclear whether these outcomes are due to device selection or patient factors. We used propensity score matching to reduce patient heterogeneity and compare outcomes in pediatric patients supported with BiVADs with a similar LVAD cohort. METHODS: The Pedimacs registry was queried for patients who were supported with BiVAD or LVAD. Patients were analyzed by BiVAD or LVAD at primary implant and the 2 groups were compared before and after using propensity score matching. RESULTS: Of 363 patients who met inclusion criteria, 63 (17%) underwent primary BiVAD support. After propensity score matching, differences between cohorts were reduced. Six months after implant, in the BiVAD cohort (LVAD cohort) 52.5% (42.5%) had been transplanted; 32.5% (40%) were alive with device, and 15% (10%) had died. Survival was similar between cohorts (P = .31, log-rank), but patients with BiVADs were more likely to experience a major adverse event in the form of bleeding (P = .04, log-rank). At 1 week and 1 and 3 months' postimplant, the percentage of patients on mechanical ventilation, on dialysis, or with elevated bilirubin was similar between the 2 groups. CONCLUSIONS: When propensity scores were used to reduce differences in patient characteristics, there were no differences in survival but more major adverse events in the patients with BiVADs, particularly bleeding. Differences in unmatched patient outcomes between LVAD and BiVAD cohorts likely represent differences in severity of illness rather than mode of support.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Implantação de Prótese , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/mortalidade , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pontuação de Propensão , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade
16.
Ann Thorac Surg ; 110(1): 205-206, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31866484
17.
Pediatr Cardiol ; 41(2): 334-340, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31865441

RESUMO

Data are limited on outcomes associated with mitral valve surgery in infants. Prior studies report high mortality and increased risk for late cardiac failure particularly for those with mitral stenosis. We sought to evaluate outcomes in patients with mitral stenosis (MS) or regurgitation (MR) who had mitral valvuloplasty or replacement in the first year of life. A retrospective analysis of all patients in a single institution who underwent mitral valvuloplasty or replacement in their first year of life from 2004 to 2016 (n = 25), excluding patients with single ventricle pathology or those undergoing surgery for atrioventricular canal defect, was carried out. Median age and weight at surgery were 76.5 days (range 2-329) and 4.5 kg (range 3.0-10.1), respectively. The primary mitral pathology was MR in 16 and MS in 9 patients. Median follow-up among living patients was 4 years (range 106 days-12.3 years). Overall survival was 96% at 30 days and 87.8% at 1, 5, and 10 years. There were three early deaths (12%), all within 6 weeks of surgery. There were no late deaths. Three patients required valve replacement, 1 of which had a primary mitral valve replacement and died within 30 days of surgery. Re-intervention-free survival (surgical and catheter based) was 83.8%, 73.3%, and 48.9% at 1, 5, and 10 years per Kaplan-Meier estimates. There was no difference in re-intervention-free survival between patients with MR versus MS. No risk factors for death or re-intervention were identified. Mitral valvuloplasty and replacement can be performed in infants under 1 year of age with acceptable survival and need for re-intervention.


Assuntos
Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Feminino , Humanos , Lactente , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
J Cardiovasc Magn Reson ; 21(1): 67, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31672164

RESUMO

BACKGROUND: Injury to vital structures posterior to the sternum is a complication associated with redo sternotomy in congenital cardiac surgery. The goal of our study was a novel evaluation of real-time cine cardiovascular magnetic resonance (CMR) to predict the presence of significant retrosternal adhesions of cardiac and vascular structures prior to redo sternotomy in patients with congenital heart disease. METHODS: Twenty-three patients who had prior congenital heart surgery via median sternotomy had comprehensive CMR studies prior to redo sternotomy. The real time cine (RTC) sequence that was used is an ungated balanced steady-state free precession (bSSFP) sequence using SENSitivity Encoding for acceleration with real-time reconstruction. Spontaneously breathing patients were instructed to take deep breaths during the acquisition whilst increased tidal volumes were delivered to mechanically ventilated patients. All patients underwent redo cardiac surgery subsequently and the presence and severity of retrosternal adhesions were noted at the time of the redo sternotomies. RESULTS: Median age at the time of CMR and operation were 5.5 years (range, 0.2-18.4y) and 6.1 years (range, 0.3-18.8y) respectively. There were 15 males and 8 females in the study group. Preoperative retrosternal adhesions were identified on RTC in 13 patients and confirmed in 11 (85%) at the time of surgery. In only 2 patients, no adhesions were identified on CMR but were found to have significant retrosternal adhesions at surgery; false positive rate 15% (CI 0.4-29.6%), false negative rate 20% (CI 3.7-36.4%). The total classification error of the real time cine sequence was 17% (CI 1.7-32.4%) with an overall accuracy of 83% (CI 67.7-98.4%). Standard breath-hold cine images correlated poorly with surgical findings and did not increase the diagnostic yield. CONCLUSIONS: RTC imaging can predict the presence of significant retrosternal adhesions and thus help in risk assessment prior to redo sternotomy. These findings complement the surgical planning and potentially reduce surgical complications .


Assuntos
Cardiopatias Congênitas/cirurgia , Imagem Cinética por Ressonância Magnética , Esternotomia/efeitos adversos , Doenças Torácicas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Doenças Torácicas/etiologia , Aderências Teciduais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA