Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Sport Nutr Exerc Metab ; 29(4): 388­396, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30507256

RESUMO

Low urinary luteinizing hormone (LH) values have been discussed as a marker to detect steroid abuse. However, suppressed LH concentrations related to highly diluted urine samples could be a misleading indication of anabolic steroid abuse. One aim of the present study was to examine the effect of hyperhydration on the interpretation of LH findings during doping control analysis and to investigate different possibilities to correct volume-related changes in urinary LH concentrations. Seven healthy, physically active, nonsmoking White males were examined for a 72-hr period, using water and a commercial sports drink as hyperhydration agents (20 ml/kg body weight). Urine samples were collected and analyzed according to the World Anti-Doping Agency's technical documents. Baseline urinary LH concentrations, expressed as the mean ± SD for each individual, were within the acceptable physiological range (7.11 ± 5.42 IU/L). A comparison of the measured LH values for both hyperhydration phases (Phase A: 4.24 ± 5.60 IU/L and Phase B: 4.74 ± 4.72 IU/L) with the baseline ("normal") values showed significant differences (Phase A: p < .001 and Phase B: p < .001), suggesting the clear effect of urine dilution due to hyperhydration. However, an adjustment of urinary LH concentrations by specific gravity based on a reference value of 1.020 seems to adequately correct the hyperhydration-induced decrease on the LH levels.


Assuntos
Dopagem Esportivo , Hormônio Luteinizante/urina , Estado de Hidratação do Organismo , Adulto , Atletas , Água Potável/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Gravidade Específica
2.
Artigo em Inglês | MEDLINE | ID: mdl-28850889

RESUMO

This paper presents the development and validation of a high-resolution full scan (FS) electron impact ionization (EI) gas chromatography coupled to quadrupole Time-of-Flight mass spectrometry (GC/QTOF) platform for screening anabolic androgenic steroids (AAS) in human urine samples. The World Antidoping Agency (WADA) enlists AAS as prohibited doping agents in sports, and our method has been developed to comply with the qualitative specifications of WADA to be applied for the detection of sports antidoping prohibited substances, mainly for AAS. The method also comprises of the quantitative analysis of the WADA's Athlete Biological Passport (ABP) endogenous steroidal parameters. The applied preparation of urine samples includes enzymatic hydrolysis for the cleavage of the Phase II glucuronide conjugates, generic liquid-liquid extraction and trimethylsilyl (TMS) derivatization steps. Tandem mass spectrometry (MS/MS) acquisition was applied on few selected ions to enhance the specificity and sensitivity of GC/TOF signal of few compounds. The full scan high resolution acquisition of analytical signal, for known and unknown TMS derivatives of AAS provides the antidoping system with a new analytical tool for the detection designer drugs and novel metabolites, which prolongs the AAS detection, after electronic data files' reprocessing. The current method is complementary to the respective liquid chromatography coupled to mass spectrometry (LC/MS) methodology widely used to detect prohibited molecules in sport, which cannot be efficiently ionized with atmospheric pressure ionization interface.


Assuntos
Anabolizantes/urina , Dopagem Esportivo/prevenção & controle , Cromatografia Gasosa-Espectrometria de Massas/métodos , Androsterona/urina , Criança , Epitestosterona/urina , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA