Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Atherosclerosis ; 395: 118520, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38944545

RESUMO

BACKGROUND: Patients with myocardial ischemia without obstructive coronary artery disease often have coronary microvascular dysfunction (CMD) and associated increased risk of cardiovascular (CV) events and anginal hospitalizations. Epicardial adipose tissue (EAT) covers much of the myocardium and coronary arteries and when dysfunctional, secretes proinflammatory cytokines and is associated with CV events. While oxidative stress and systemic inflammation are associated with CMD, the relationship between EAT and CMD in women is not well known. METHODS: Women diagnosed with CMD (n = 21) who underwent coronary computed tomography with coronary artery calcium (CAC) scoring were compared to a reference group (RG) of women referred for CAC screening for preventive risk assessment (n = 181). EAT attenuation (Hounsfield units (HU)) was measured adjacent to the proximal right coronary artery, along with subcutaneous adipose tissue (SCAT). Two-sample t-tests with unequal variances were utilized. RESULTS: Mean age of the CMD group was 56 ± 8 years and body mass index (BMI) was 31.6 ± 6.8 kg/m2. CV risk factors in the CMD group were prevalent: 67 % hypertension, 44 % hyperlipidemia, and 33 % diabetes. Both CMD and RG had similar CAC score (25.86 ± 59.54 vs. 24.17 ± 104.6; p = 0.21. In the CMD group, 67 % had a CAC of 0. Minimal atherosclerosis (CAD-RADS 1) was present in 76 % of women with CMD. The CMD group had lower EAT attenuation than RG (-103.3 ± 6.33 HU vs. -97.9 ± 8.3 HU, p = 0.009, respectively). There were no differences in SCAT attenuation. Hypertension, smoking history, age, BMI, and CAC score did not correlate with EAT in either of the groups. CONCLUSIONS: Women with CMD have decreased EAT attenuation compared to RG women. EAT-mediated inflammation and changes in vascular tone may be a mechanistic contributor to abnormal microvascular reactivity. Clinical trials testing therapeutic strategies to decrease EAT may be warranted in the management of CMD.


Assuntos
Tecido Adiposo , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Circulação Coronária , Vasos Coronários , Microcirculação , Pericárdio , Humanos , Feminino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Projetos Piloto , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Idoso , Fatores de Risco de Doenças Cardíacas , Microvasos/diagnóstico por imagem , Microvasos/fisiopatologia , Valor Preditivo dos Testes , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Tecido Adiposo Epicárdico
2.
Med Res Arch ; 11(4)2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37484871

RESUMO

Objective: Coronary heart disease is a leading cause of death and disability. Although psychological stress has been identified as an important potential contributor, mechanisms by which stress increases risk of heart disease and mortality are not fully understood. The purpose of this study was to assess mechanisms by which stress acts through the brain and heart to confer increased CHD risk. Methods: Coronary Heart Disease patients (N=10) underwent cardiac imaging with [Tc-99m] sestamibi single photon emission tomography at rest and during a public speaking mental stress task. Patients returned for a second day and underwent positron emission tomography imaging of the brain, heart, bone marrow, aorta (indicating inflammation) and subcutaneous adipose tissue, after injection of [18F]2-fluoro-2-deoxyglucose for assessment of glucose uptake followed mental stress. Patients with (N=4) and without (N=6) mental stress-induced myocardial ischemia were compared for glucose uptake in brain, heart, adipose tissue and aorta with mental stress. Results: Patients with mental stress-induced ischemia showed a pattern of increased uptake in the heart, medial prefrontal cortex, and adipose tissue with stress. In the heart disease group as a whole, activity increase with stress in the medial prefrontal brain and amygdala correlated with stress-induced increases in spleen (r=0.69, p=0.038; and r=0.69, p=0.04 respectfully). Stress-induced frontal lobe increased uptake correlated with stress-induced aorta uptake (r=0.71, p=0.016). Activity in insula and medial prefrontal cortex was correlated with post-stress activity in bone marrow and adipose tissue. Activity in other brain areas not implicated in stress did not show similar correlations. Increases in medial prefrontal activity with stress correlated with increased cardiac glucose uptake with stress, suggestive of myocardial ischemia (r=0.85, p=0.004). Conclusions: These findings suggest a link between brain response to stress in key areas mediating emotion and peripheral organs involved in inflammation and hematopoietic activity, as well as myocardial ischemia, in Coronary Heart Disease patients.

3.
Open Forum Infect Dis ; 9(12): ofac629, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36570965

RESUMO

Background: Latent tuberculosis infection (LTBI) has been associated with increased cardiovascular risk. We investigated the activation and pro-inflammatory profile of monocytes in individuals with LTBI and their association with coronary artery disease (CAD). Methods: Individuals 40-70 years old in Lima, Peru, underwent QuantiFERON-TB testing to define LTBI, completed a coronary computed tomography angiography to evaluate CAD, and provided blood for monocyte profiling using flow cytometry. Cells were stimulated with lipopolysaccharide to assess interleukin-6 (IL-6) and tumor necrosis factor (TNF)-α responses. Results: The clinical characteristics of the LTBI (n = 28) and non-LTBI (n = 41) groups were similar. All monocyte subsets from LTBI individuals exhibited higher mean fluorescence intensity (MFI) of CX3CR1 and CD36 compared with non-LTBI individuals. LTBI individuals had an increased proportion of nonclassical monocytes expressing IL-6 (44.9 vs 26.9; P = .014), TNF-α (62.3 vs 35.1; P = .014), and TNF-α+IL-6+ (43.2 vs 36.6; P = .042). Among LTBI individuals, CAD was associated with lower CX3CR1 MFI on classical monocytes and lower CD36 MFI across all monocyte subsets. In multivariable analyses, lower CD36 MFI on total monocytes (b = -0.17; P = .002) and all subsets remained independently associated with CAD in LTBI. Conclusions: Individuals with LTBI have distinct monocyte alterations suggestive of an exacerbated inflammatory response and tissue migration. Whether these alterations contribute to cardiovascular disease pathogenesis warrants further investigation.

5.
Eur J Radiol ; 150: 110116, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34996651

RESUMO

Positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (18F-FDG) has become the method of choice for tumor staging in lung cancer patients with improved diagnostic accuracy for the evaluation of lymph node involvement and distant metastasis. Due to its spectral capabilities, dual-energy CT (DECT) employs a material decomposition algorithm enabling precise quantification of iodine concentrations in distinct tissues. This technique enhances the characterization of tumor blood supply and has demonstrated promising results for the assessment of therapy response in patients with lung cancer. Several studies have demonstrated that DECT provides additional value to the PET-based evaluation of glycolytic activity, especially for the evaluation of therapy response and follow-up of patients with lung cancer. The combination of PET and DECT in a single scanner system enables the simultaneous assessment of glycolytic activity and iodine enhancement, offering further insight to the characterization of tumorous tissues. Recently a new approach of a novel integrated PET/DECT was investigated in a pilot study on patients with non-small cell lung cancer (NSCLC). The study showed a moderate correlation between PET-based standard uptake values (SUV) and DECT-based iodine densities in the evaluation of lung tumorous tissue but with limited assessment of lymph nodes. The following review on tumorous tissue characterization using PET and DECT imaging describes the strengths and limitations of this novel technique.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Iodo , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Estadiamento de Neoplasias , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos
6.
Nutr Metab (Lond) ; 18(1): 73, 2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-34271946

RESUMO

BACKGROUND: Despite the worldwide burden of diverticular disease, the connections between diverticular disease and dietary habits remain poorly understood, particularly in an asymptomatic representative sample. We investigated the association between asymptomatic diverticular disease as assessed by magnetic resonance imaging (MRI) and dietary habits in a Western study cohort. METHODS: Participants from a cross-sectional sample of a population-based cohort study underwent whole-body 3T-MRI including an isotropic VIBE-Dixon sequence. The presence and extent of diverticular disease was assessed in blinded fashion. Habitual dietary intake was recorded using a blended approach, applying 24-h food lists and a food-frequency questionnaire. Traditional cardiometabolic risk factors were obtained by interviews and medical examination. Univariate and multivariate associations were calculated. RESULTS: A total of 308 subjects were included in this analysis (56% male, 56.4 ± 9.1 years). 39.9% had any form of diverticular disease and 15.3% had advanced asymptomatic diverticular disease. After adjustment for age, sex and total energy intake a higher intake of fiber and vegetables was associated with a lower odds for asymptomatic diverticular disease (fiber: OR 0.68 95% CI [0.48, 0.95]; vegetables: OR 0.72 95% CI [0.53, 0.97]) and an increased intake of meat was associated with an approximately two-fold higher odds for advanced asymptomatic diverticular disease (OR 1.84 95% CI [1.13, 2.99]). However, after additional adjustment for body-mass-index (BMI), alcohol consumption, smoking behavior and physical activity only a high fiber and vegetables intake remained significantly associated with lower odds of asymptomatic diverticular disease. CONCLUSION: Our results indicate that a high-fiber diet and increased intake of vegetables is associated with lower odds of having asymptomatic diverticular disease, independent of age, sex, total energy intake, BMI and other life-style factors.

7.
J Thorac Imaging ; 36(6): 382-388, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34029282

RESUMO

PURPOSE: The aim of this pilot study was to prospectively evaluate the first integrated positron emission tomography (PET)/dual-energy computed tomography (DECT) system performance in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: In this single-center, prospective trial, consecutive patients with NSCLC referred for a PET study between May 2017 and June 2018 were enrolled. All patients received contrast-enhanced imaging on a clinical PET/DECT system. Data analysis included PET-based standard uptake values (SUVmax) and DECT-based iodine densities of tumor masses, lymph nodes, and distant metastases. Results were analyzed using correlation tests and receiver operating characteristics curves. RESULTS: The study population was composed of 21 patients (median age 62 y, 14 male patients). A moderate positive correlation was found between iodine density values (2.2 mg/mL) and SUVmax (10.5) in tumor masses (ρ=0.53, P<0.01). Iodine density values (2.3 mg/mL) and SUVmax (5.4) of lymph node metastases showed a weak positive correlation (ρ=0.23, P=0.14). In addition, iodine quantification analysis provided no added value in differentiating between pathologic and nonpathologic lymph nodes with an area under the curve (AUC) of 0.55 using PET-based SUVmax as the reference standard. A weak positive correlation was observed between iodine density (2.2 mg/mL) and SUVmax in distant metastases (14.9, ρ=0.23, P=0.52). CONCLUSIONS: The application of an integrated PET/DECT system in lung cancer might provide additional insights in the assessment of tumor masses. However, the added value of iodine density quantification for the evaluation of lymph nodes and distant metastases seems limited.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Linfonodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
8.
J Thorac Imaging ; 36(6): 345-352, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205821

RESUMO

OBJECTIVES: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging. MATERIALS AND METHODS: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial. All patients underwent coronary CT angiography and CT-MPI with hyperemia induced by the intravenous administration of regadenoson (0.4 mg/5 mL). Patient experience and findings on CT-MPI images were compared to SPECT imaging. RESULTS: Patient experience and safety were similar between CT-MPI and SPECT procedures and no serious adverse events due to the administration of regadenoson occurred. SPECT resulted in a higher number of mild adverse events than CT-MPI. Patient radiation exposure was similar during the combined coronary computed tomography angiography and CT-MPI (4.4 [2.7] mSv) and SPECT imaging (5.6 [1.7] mSv) (P-value 0.401) procedures. Using SPECT as the reference standard, CT-MPI analysis showed a sensitivity of 58.3% (95% confidence interval [CI]: 27.7-84.8), a specificity of 100% (95% CI: 73.5-100), and an accuracy of 79.1% (95% CI: 57.9-92.87). Low apparent sensitivity occurred when the SPECT defects were small and highly suspicious for artifacts. CONCLUSIONS: This study demonstrated that CT-MPI is safe, well tolerated, and can be performed with comparable radiation exposure to SPECT. CT-MPI has the benefit of providing both complete anatomic coronary evaluation and assessment of myocardial perfusion.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Purinas , Pirazóis , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
9.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
J Nucl Cardiol ; 27(3): 1030-1039, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32026327

RESUMO

BACKGROUND: Coronary physiology assessments have been shown by multiple trials to add clinical value in detecting significant coronary artery disease and predicting cardiovascular outcomes. Fractional flow reserve (FFR) obtained during invasive coronary angiography (ICA) has become the new reference standard for hemodynamic significance detection. Absolute myocardial blood flow (MBF) quantification by means of dynamic positron emission tomography (dPET) has high diagnostic and prognostic values. FFR is an invasive measure and as such cannot be applied broadly, while MBF quantification is commonly performed on standard vascular territories intermixing normal flow from normal regions with abnormal flow from abnormal regions and consequently limiting its diagnostic power. OBJECTIVE: The aim of this study is to provide physicians with reliable software tools for the non-invasive assessment of lesion-specific physiological significance for the entire coronary tree by combining PET-derived absolute flow data and coronary computed tomography angiography (CTA)-derived anatomy and coronary centerlines. METHODS: The dynamic PET/CTA myocardial blood flow assessment with fused imagery (DEMYSTIFY) study is an observational prospective clinical study to develop algorithms and software tools to fuse coronary anatomy data obtained from CTA with dPET data to non-invasively measure absolute MBF, myocardial flow reserve, and relative flow reserve across specific coronary lesions. Patients (N = 108) will be collected from 4 institutions (Emory University Hospital, USA; Chonnam National University Hospital, South Korea; Samsung Medical Center, South Korea; Seoul National University Hospital, South Korea). These results will be compared to those obtained invasively in the catheterization laboratory and to a relatively novel non-invasive technique to estimate FFR based on CTA and computational fluid dynamics. CONCLUSIONS: Success of these developments should lead to the following benefits: (1) eliminate unnecessary invasive coronary angiography in patients with no significant lesions, (2) avoid stenting physiologically insignificant lesions, (3) guide percutaneous coronary interventions process to the location of significant lesions, (4) provide a flow-color-coded 3D roadmap of the entire coronary tree to guide bypass surgery, and (5) use less radiation and lower the cost from unnecessary procedures. TRIAL REGISTRY: The DEMYSTIFY study has been registered on ClinicalTrials.gov with registration number NCT04221594.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Circulação Coronária , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Bases de Dados Factuais , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica , Humanos , Microcirculação , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Padrões de Referência , Reprodutibilidade dos Testes , República da Coreia , Sensibilidade e Especificidade , Software , Estados Unidos
11.
J Thorac Imaging ; 35 Suppl 1: S3-S10, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32073539

RESUMO

The field of artificial intelligence (AI) is currently experiencing a period of extensive growth in a wide variety of fields, medicine not being the exception. The base of AI is mathematics and computer science, and the current fame of AI in industry and research stands on 3 pillars: big data, high performance computing infrastructure, and algorithms. In the current digital era, increased storage capabilities and data collection systems, lead to a massive influx of data for AI algorithm. The size and quality of data are 2 major factors influencing performance of AI applications. However, it is highly dependent on the type of task at hand and algorithm chosen to perform this task. AI may potentially automate several tedious tasks in radiology, particularly in cardiothoracic imaging, by pre-readings for the detection of abnormalities, accurate quantifications, for example, oncologic volume lesion tracking and cardiac volume and image optimization. Although AI-based applications offer great opportunity to improve radiology workflow, several challenges need to be addressed starting from image standardization, sophisticated algorithm development, and large-scale evaluation. Integration of AI into the clinical workflow also needs to address legal barriers related to security and protection of patient-sensitive data and liability before AI will reach its full potential in cardiothoracic imaging.


Assuntos
Inteligência Artificial , Radiologia/métodos , Algoritmos , Humanos
12.
Radiology ; 293(2): 260-271, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502938

RESUMO

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities. Low-kiloelectron-volt VM imaging may be useful for salvaging CT studies with suboptimal contrast material delivery or providing additional information on the arterial vasculature obtained from venous phase acquisitions. For patients with renal impairment, substantial reductions in the use of iodinated contrast material can be achieved by using lower-energy VM imaging. The authors recommend routine reconstruction of VM images at 50 keV when using dual-energy CT to exploit the increased contrast properties. For reduction of beam-hardening artifacts, VM imaging at 120 keV is useful for the initial assessment.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Doenças Cardiovasculares/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Neoplasias/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
13.
J Cardiovasc Comput Tomogr ; 13(1): 81-84, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30377090

RESUMO

ObjectiveTo assess the feasibility of dual energy CT (DECT) to derive myocardial extracellular volume (ECV) and detect myocardial ECV differences without a non-contrast acquisition, compared to single energy CT (SECT). MethodsSubjects (n = 35) with focal fibrosis (n = 17), diffuse fibrosis (n = 10), and controls (n = 9) underwent non-contrast and delayed acquisitions to calculate SECT-ECV. DECT-ECV was calculated using the delayed acquisition and the derived virtual non-contrast images. In the control and diffuse fibrotic groups, the entire myocardium of the left ventricle was used to calculate ECV. Two ROIs were placed in the focal fibrotic group, one in normal and one in fibrotic myocardium. ResultsMedian ECV was 33.4% (IQR, 30.1-37.4) using SECT and 34.9% (IQR, 31.2-39.2) using DECT (p = 0.401). For both techniques, focal and diffuse fibrosis had significantly higher ECV values (all p < 0.021) than normal myocardium. There was no systematic bias between DECT and SECT (p = 0.348). SECT had a higher radiation dose (1.1 mSv difference) than DECT (p < 0.001). ConclusionECV can be measured using a DECT approach with only a delayed acquisition. The DECT approach provides similar results at a lower radiation dose compared to SECT.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cardiomiopatias/patologia , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Fibrose , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/efeitos adversos
14.
Eur Radiol ; 29(3): 1094-1103, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30151643

RESUMO

OBJECTIVES: Diverticular disease represents an increasing pathology and healthcare burden worldwide. Our aim was to study the prevalence, extent and distribution of asymptomatic diverticular disease assessed by magnetic resonance imaging (MRI) in a sample of a Western population. METHODS: Subjects from a population-based cohort study who underwent 3-T MRI were analyzed for the prevalence and extent of diverticula of the colon using an isotropic VIBE-Dixon gradient-echo sequence. The extent of diverticular disease was categorized according to the number of diverticula in each colonic segment. Univariate and adjusted analyses were performed to assess associated characteristics and risk factors. RESULTS: Among 393 subjects included in the analysis (56.4 ± 9.2 years, 57.5% males), 164 (42%) had diverticular disease, with the highest prevalence in the left-sided colonic segments (93% diverticular disease in the descending and sigmoid segment). Subjects with advanced diverticular disease were older (62.1 vs. 54.4 years) and had a higher body mass index (BMI), LDL cholesterol levels and systolic blood pressure (30.2 ± 5.1 vs. 27.8 ± 4.9 kg/m2, 149.8 ± 29.3 vs. 135.2 ± 32.9 mg/dl and 128.2 ± 14.1 vs. 118.4 ± 16.1 mmHg, respectively; all p > 0.003) compared with subjects without diverticular disease. In contrast, no significant correlation could be found for gender, physical activity, smoking status and alcohol consumption (all p > 0.31). Intra-rater reliability was excellent for all colonic segments (intra-class correlation [ICC] = 0.99-1.00), and inter-rater reliability was excellent for left- and right-sided colonic segments (ICC = 0.84-0.97). CONCLUSIONS: These findings provide insights into the disease mechanism of asymptomatic diverticular disease and may help to improve prevention of diverticulosis and its associated complications. KEY POINTS: • Overall prevalence of asymptomatic diverticular disease assessed by MRI was 42%, affecting predominantly the left-sided colon. • Asymptomatic diverticular disease was associated with age and cardiometabolic risk factors. • Magnetic resonance imaging reveals insights into the pathophysiologic mechanism of asymptomatic diverticular disease.


Assuntos
Colo/patologia , Doenças Diverticulares/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso , Índice de Massa Corporal , Estudos de Coortes , Doenças Diverticulares/epidemiologia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco
15.
Expert Rev Cardiovasc Ther ; 16(6): 441-453, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29734858

RESUMO

INTRODUCTION: Computed tomographic (CT) coronary artery calcium scoring (CAC) has been validated as a well-established screening method for cardiovascular risk stratification and treatment management that is used in addition to traditional risk factors. The purpose of this review is to present an update on current and future applications of CAC. Areas covered: The topic of CAC is summarized from its introduction to current application with focus on the validation and clinical integration including cardiovascular risk prediction and outcome, cost-effectiveness, impact on downstream medical testing, and the technical advances in scanner and software technology that are shaping the future of CAC. Furthermore, this review aims to provide guidance for the appropriate clinical use of CAC. Expert commentary: CAC is a well-established screening test in preventive care that is underused in daily clinical practice. The widespread clinical implementation of CAC will be decided by future technical advances in CT image acquisition, cost-effectiveness, and reimbursement status.


Assuntos
Cálcio/metabolismo , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Vasos Coronários/patologia , Análise Custo-Benefício , Humanos , Medição de Risco/métodos , Fatores de Risco
16.
Eur Radiol ; 28(8): 3393-3404, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460075

RESUMO

OBJECTIVES: To assess the image quality and diagnostic accuracy of a noise-optimized virtual monoenergetic imaging (VMI+) algorithm compared with standard virtual monoenergetic imaging (VMI) and linearly-blended (M_0.6) reconstructions for the detection of hypervascular liver lesions in dual-energy CT (DECT). METHODS: Thirty patients who underwent clinical liver MRI were prospectively enrolled. Within 60 days of MRI, arterial phase DECT images were acquired on a third-generation dual-source CT and reconstructed with M_0.6, VMI and VMI+ algorithms from 40 to 100 keV in 5-keV intervals. Liver parenchyma and lesion contrast-to-noise-ratios (CNR) were calculated. Two radiologists assessed image quality. Lesion sensitivity, specificity and area under the receiver operating characteristic curves (AUCs) were calculated for the three algorithms with MRI as the reference standard. RESULTS: VMI+ datasets from 40 to 60 keV provided the highest liver parenchyma and lesion CNR (p ≤0.021); 50 keV VMI+ provided the highest subjective image quality (4.40±0.54), significantly higher compared to VMI and M_0.6 (all p <0.001), and the best diagnostic accuracy in < 1-cm diameter lesions (AUC=0.833 vs. 0.777 and 0.749, respectively; p ≤0.003). CONCLUSIONS: 50-keV VMI+ provides superior image quality and diagnostic accuracy for the detection of hypervascular liver lesions with a diameter < 1cm compared to VMI or M_0.6 reconstructions. KEY POINTS: • Low-keV VMI+ are characterized by higher contrast resulting from maximum iodine attenuation. • VMI+ provides superior image quality compared with VMI or M_0.6. • 50-keV_VMI+ provides higher accuracy for the detection of hypervascular liver lesions < 1cm.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
17.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
18.
Int J Cardiovasc Imaging ; 34(6): 921-929, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29305739

RESUMO

To develop a quantitative T1-mapping-based synthetic inversion recovery (IRsynth) approach to calculate the optimal inversion time (TI0) for late gadolinium enhancement (LGE) imaging. Prospectively enrolled patients (n = 130, 58 ± 16 years) underwent cardiac MRI on a 1.5T system including Look-Locker TI-scout (LL), modified LL IR (MOLLI)-based T1-mapping, and LGE acquisitions. Patients were randomized into two groups: LL group (TI-scout followed T1-mapping) or MOLLI group (T1-mapping followed TI-scout). In both groups, the second acquisition was used to determine the TI0 for LGE. IRsynth images were generated from T1-maps between TI = 200-400 ms in 5 ms increments. Image quality was rated on a 3-point scale and the remote/background signal intensity ratio (SIR) was calculated. In the LL group (n = 53), the TI-scout-based TI0 was significantly shorter compared to IRsynth [230 ms (219-242) vs. 280 ms (263-297), P < 0.0001]. The TI0 used for LGE was set 30-40 ms longer [261 ms (247-276), P < 0.0001] than the TI-scout-based TI0, resulting in a TI0 ~ 20 ms shorter than what was obtained by IRsynth (P = 0.0156). In the MOLLI group (n = 63), IRsynth-based TI0 was significantly longer than the TI-scout-based TI0 [298 ms (262-334) vs. 242 ms (217-267), P = 0.0313]. The quality of myocardial nulling was rated higher [2.4 (2.2-2.5) vs. 2.0 (1.8-2.1), P = 0.0042] and the remote/background SIR was found to be more optimal (1.6 [1.1-2.1] vs. 2.6 [1.8-3.3], P = 0.0256) in the MOLLI group. T1-based IRsynth selects TI0 for LGE more accurately than conventional TI-scout imaging. IRsynth improves TI0 selection by providing excellent visualization of the representative image contrast for LGE images, reducing operator dependence in LGE acquisition.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem Cardíaca/métodos , Técnicas de Imagem Cardíaca/normas , Doença Crônica , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
19.
Invest Radiol ; 53(2): 103-109, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29016370

RESUMO

OBJECTIVES: The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS: Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-energy coronary computed tomography angiography were retrospectively included in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study. Linearly blended (M_0.6) and calcium-subtracted images were reconstructed. Two independent observers assessed luminal visualization of the coronary arteries in a segment-based analysis, subjective image quality, and diagnostic confidence using 5-point Likert scales. Contrast-to-noise ratios for both data sets were calculated. Wilcoxon testing and Cohen's κ were used for statistical comparisons. RESULTS: Calcium-subtracted image series showed improved lumen visualization of the coronary arteries (P = 0.008), with excellent interreader agreement (mean score, 3.3; κ = 0.82), compared with M_0.6 series (mean score, 2.9; κ = 0.77). The calcium subtraction algorithm improved diagnostic confidence compared with the M_0.6 reconstructions (mean scores, 4.0 and 3.1, respectively; all P ≤ 0.002). The image quality analysis showed no significant differences between calcium-subtracted and M_0.6 data sets (subjectively: mean scores, 4.1 and 4.2, respectively, P = 0.442; objectively: mean contrast-to-noise ratio, 37.0 and 38.2, respectively, P = 0.733). CONCLUSIONS: A prototype algorithm for calcium subtraction improves coronary lumen visualization and diagnostic confidence in patients with heavy coronary calcifications without differences in conventional subjective and objective measures of image quality.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Eur J Radiol ; 91: 29-34, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28629567

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of CT coronary artery calcium scoring (CACS) with tin pre-filtration (Sn100kVp) using iterative beam-hardening correction (IBHC) calcium material reconstruction compared to the standard 120kVp acquisition. BACKGROUND: Third generation dual-source CT (DSCT) CACS with Sn100kVp acquisition allows significant dose reduction. However, the Sn100kVp spectrum is harder with lower contrast compared to 120kVp, resulting in lower calcium score values. Sn100kVp spectral correction using IBHC-based calcium material reconstruction may restore comparable calcium values. METHODS: Image data of 62 patients (56% male, age 63.9±9.2years) who underwent a clinically-indicated CACS acquisition using the standard 120kVp protocol and an additional Sn100kVp CACS scan as part of a research study were retrospectively analyzed. Datasets of the Sn100kVp scans were reconstructed using a dedicated spectral IBHC CACS reconstruction to restore the spectral response of 120kVp spectra. Agatston scores were derived from 120kVp and IBHC reconstructed Sn100kVp studies. Pearson's correlation coefficient was assessed and Agatston score categories and percentile-based risk categorization were compared. RESULTS: Median Agatston scores derived from IBHC Sn100kVp scans and 120kVp acquisition were 31.7 and 34.1, respectively (p=0.057). Pearson's correlation coefficient showed excellent correlation between the acquisitions (r=0.99, p<0.0001). Agatston score categories and percentile-based cardiac risk categories showed excellent agreement (ĸ=1.00 and ĸ=0.99), resulting in a low cardiac risk reclassification of 1.6% with the use of IBHC CACS reconstruction. Image noise was 24.9±3.6HU in IBHC Sn100kVp and 17.1±3.9HU in 120kVp scans (p<0.0001). The dose-length-product was 13.2±3.4mGycm with IBHC Sn100kVp and 59.1±22.9mGycm with 120kVp scans (p<0.0001), resulting in a significantly lower effective radiation dose (0.19±0.07mSv vs. 0.83±0.33mSv, p<0.0001) for IBHC Sn100kVp scans. CONCLUSION: Low voltage CACS with tin filtration using a dedicated IBHC CACS material reconstruction algorithm shows excellent correlation and agreement with the standard 120kVp acquisition regarding Agatston score and cardiac risk categorization, while radiation dose is significantly reduced by 75% to the level of a chest x-ray.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Cálcio , Feminino , Filtração , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Estanho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA