1.
Int J Comput Assist Radiol Surg ; 18(11): 1977-1986, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37460915

RESUMO

PURPOSE: The use of robotics is emerging for performing interventional radiology procedures. Robots in interventional radiology are typically controlled using button presses and joystick movements. This study identified how different human-robot interfaces affect endovascular surgical performance using interventional radiology simulations. METHODS: Nine participants performed a navigation task on an interventional radiology simulator with three different human-computer interfaces. Using Simulation Open Framework Architecture we developed a simulation profile of vessels, catheters and guidewires. We designed and manufactured a bespoke haptic interventional radiology controller for robotic systems to control the simulation. Metrics including time taken for navigation, number of incorrect catheterisations, number of catheter and guidewire prolapses and forces applied to vessel walls were measured and used to characterise the interfaces. Finally, participants responded to a questionnaire to evaluate the perception of the controllers. RESULTS: Time taken for navigation, number of incorrect catheterisations and the number of catheter and guidewire prolapses, showed that the device-mimicking controller is better suited for controlling interventional neuroradiology procedures over joystick control approaches. Qualitative metrics also showed that interventional radiologists prefer a device-mimicking controller approach over a joystick approach. CONCLUSION: Of the four metrics used to compare and contrast the human-robot interfaces, three conclusively showed that a device-mimicking controller was better suited for controlling interventional neuroradiology robotics.


Assuntos
Procedimentos Endovasculares , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Cateterismo/métodos , Catéteres , Prolapso
2.
IEEE Robot Autom Lett ; 8(2): 1005-1012, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36733442

RESUMO

Soft robots that grow through eversion/apical extension can effectively navigate fragile environments such as ducts and vessels inside the human body. This paper presents the physics-based model of a miniature steerable eversion growing robot. We demonstrate the robot's growing, steering, stiffening and interaction capabilities. The interaction between two robot-internal components is explored, i.e., a steerable catheter for robot tip orientation, and a growing sheath for robot elongation/retraction. The behavior of the growing robot under different inner pressures and external tip forces is investigated. Simulations are carried out within the SOFA framework. Extensive experimentation with a physical robot setup demonstrates agreement with the simulations. The comparison demonstrates a mean absolute error of 10 - 20% between simulation and experimental results for curvature values, including catheter-only experiments, sheath-only experiments and full system experiments. To our knowledge, this is the first work to explore physics-based modelling of a tendon-driven steerable eversion growing robot. While our work is motivated by early breast cancer detection through mammary duct inspection and uses our MAMMOBOT robot prototype, our approach is general and relevant to similar growing robots.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA