1.
Adv Sci (Weinh) ; 6(10): 1802066, 2019 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-31131190

RESUMO

Iron single atom catalysts (Fe SACs) are the best-known nonprecious metal (NPM) catalysts for the oxygen reduction reaction (ORR) of polymer electrolyte membrane fuel cells (PEMFCs), but their practical application has been constrained by the low Fe SACs loading (<2 wt%). Here, a one-pot pyrolysis method is reported for the synthesis of iron single atoms on graphene (FeSA-G) with a high Fe SAC loading of ≈7.7 ± 1.3 wt%. The as-synthesized FeSA-G shows an onset potential of 0.950 V and a half-wave potential of 0.804 V in acid electrolyte for the ORR, similar to that of Pt/C catalysts but with a much higher stability and higher phosphate anion tolerance. High temperature SiO2 nanoparticle-doped phosphoric acid/polybenzimidazole (PA/PBI/SiO2) composite membrane cells utilizing a FeSA-G cathode with Fe SAC loading of 0.3 mg cm-2 delivers a peak power density of 325 mW cm-2 at 230 °C, better than 313 mW cm-2 obtained on the cell with a Pt/C cathode at a Pt loading of 1 mg cm-2. The cell with FeSA-G cathode exhibits superior stability at 230 °C, as compared to that with Pt/C cathode. Our results provide a new approach to developing practical NPM catalysts to replace Pt-based catalysts for fuel cells.

2.
Anal Chim Acta ; 851: 78-86, 2014 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-25440668

RESUMO

Three new calixarene Tl(+) ionophores have been utilized in Tl(+) ion-selective electrodes (ISEs) yielding Nernstian response in the concentration range of 10(-2)-10(-6)M TlNO3 with a non-optimized filling solution in a conventional liquid contact ISE configuration. The complex formation constants (logßIL) for two of the calixarene derivatives with thallium(I) (i.e. 6.44 and 5.85) were measured using the sandwich membrane technique, with the other ionophore immeasurable due to eventual precipitation of the ionophore during these long-term experiments. Furthermore, the unbiased selectivity coefficients for these ionophores displayed excellent selectivity against Zn(2+), Ca(2+), Ba(2+), Cu(2+), Cd(2+) and Al(3+) with moderate selectivity against Pb(2+), Li(+), Na(+), H(+), K(+), NH4(+) and Cs(+), noting that silver was the only significant interferent with these calixarene-based ionophores. When optimizing the filling solution in a liquid contact ISE, it was possible to achieve a lower limit of detection of approximately 8nM according to the IUPAC definition. Last, the new ionophores were also evaluated in four solid-contact (SC) designs leading to Nernstian response, with the best response noted with a SC electrode utilizing a gold substrate, a poly(3-octylthiophene) (POT) ion-to-electron transducer and a poly(methyl methacrylate)-poly(decyl methacrylate) (PMMA-PDMA) co-polymer membrane. This electrode exhibited a slope of 58.4mVdecade(-1) and a lower detection limit of 30.2nM. Due to the presence of an undesirable water layer and/or leaching of redox mediator from the graphite redox buffered SC, a coated wire electrode on gold and graphite redox buffered SC yielded grossly inferior detection limits against the polypyrrole/PVC SC and POT/PMMA-PDMA SC ISEs that did not display signs of a water layer or leaching of SC ingredients into the membrane.


Assuntos
Calixarenos/química , Eletrodos Seletivos de Íons , Tálio/análise , Acrilamidas/química , Interações Hidrofóbicas e Hidrofílicas , Ionóforos/química , Limite de Detecção , Membranas Artificiais , Polimetil Metacrilato/química , Tálio/química
3.
Anal Chim Acta ; 744: 39-44, 2012 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-22935372

RESUMO

A nitrate ion-selective electrode (ISE) employing a permeable tubular membrane impregnated with a conventional ISE cocktail has been used successfully in the coulometric analysis of nitrate in fresh waters. The liquid ISE membrane comprising a nitrate ionophore [tridodecylmethylammonium nitrate (TDMAN)], lipophilic electrolyte [tetradodecyl-ammoniumtetrakis(4-chlorophenyl)borate (ETH 500)] and plasticizer [bis(3-ethyl-hexyl)sebacate (DOS)] was supported on a porous polypropylene tube. Coulometric analysis with the tubular membrane ISE showed that nitrate could be detected in the range 10-100 µM with a precision of 2.3% relative standard deviation (RSD), limit of detection of 1.1 µM and relative accuracy of 4.4% compared to a certified reference material (CRM) Lake sample.

4.
Anal Chem ; 82(14): 6203-7, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20557118

RESUMO

This paper reports on three-dimensional synchrotron radiation/Fourier transform-infrared microspectroscopy (SR/FT-IRM) imaging studies of water inclusions at the buried interface of solid-contact-ion-selective electrodes (SC-ISEs). It is our intention to describe a nondestructive method that may be used in surface studies of the buried interfaces of materials, especially multilayers of polymers. Herein, we demonstrate the power of SR/FT-IRM for studying water inclusions at the buried interfaces of SC-ISEs. A poly(methyl methacrylate)-poly(decyl methacyrlate) [PMMA-PDMA] copolymer revealed the presence of micrometer sized inclusions of water at the gold/membrane interface, while a coupling of a hydrophobic solid contact of poly(3-octylthiophene 2,5-diyl) (POT) prevented the accumulation of water at the buried interface. A similar study with a poly (3,4-ethylenedioxythiophene)/poly (styrenesulfonate) [PEDOT/PSS] solid contact also revealed an absence of distinct micrometer-sized pools of water; however, there were signs of absorption of water accompanied by swelling of the PEDOT/PSS underlayer, and these membrane zones are enriched with respect to water.


Assuntos
Polímeros/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Síncrotrons , Água/química , Ouro/química , Eletrodos Seletivos de Íons , Tiofenos/química
5.
Talanta ; 75(5): 1234-9, 2008 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18585207

RESUMO

A bielectrode array comprising a jalpaite membrane (i.e., Ag(1.5)Cu(0.5)S) copper(II) ion-selective electrode (ISE) and chalcogenide glass membrane (i.e., Fe(2.5)(Se(60)Ge(28)Sb(12))(97.5)) iron(III) ISE has been assembled by individually wiring each solid-state sensor into a single electrode body. Furthermore, a dual metal ion buffer calibration standard incorporating copper(II) and iron(III) coordinating ligands to regulate the levels of free copper(II) and iron(III) in the buffer has been developed to enable simultaneous calibration of the bielectrode ISE array. In this work, the bielectrode ISE array has been employed in the continuous flow analysis (CFA) of free copper(II) and iron(III) in seawater media. It is shown that the individual electrodes displayed Nernstian response in the metal ion buffer calibration standard over a wide dynamic range (viz., 10(-15) to 10(-5) M aCu(2+) and 10(-21) to 10(-11) M aFe(3+)), and the results of repetitive CFA analyses of free copper(II) and iron(III) in seawater are commensurate with the typical values found in coastal seawater samples. Clearly, the bielectrode ISE array may be used in the simultaneous analysis of free copper(II) and iron(III) in seawater without fear of cross-interference between the solid-state sensors.


Assuntos
Técnicas Biossensoriais/métodos , Cobre/análise , Ferro/análise , Água do Mar/análise , Cloreto de Sódio/química , Técnicas Biossensoriais/instrumentação , Soluções Tampão , Calibragem , Cátions , Calcogênios/química , Cobre/química , Eletroquímica , Vidro/química , Eletrodos Seletivos de Íons , Ferro/química , Membranas Artificiais , Água do Mar/química , Prata/química
6.
Talanta ; 57(1): 115-21, 2002 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-18968611

RESUMO

It is shown that the iron(III) chalcogenide glass membrane ion-selective electrode (ISE) can be calibrated in continuous flow analysis (CFA) using acidified iron(III) nitrate standards, yielding a 60+/-3 mV per decade change in activity of Fe(3+) response in the range 10(-7)-10(-2) M total iron(III). Extended ageing of the iron(III) ISE in 2 M zinc(II) sulphate did not alter the potentiometric response characteristics of the electrode. Furthermore, electrochemical impedance spectroscopy and X-ray photoelectron spectroscopy in the presence and absence of zinc(II) sulphate failed to detect a zinc(II) interference on the iron(III) ISE. CFA/ISE determined activities of Fe(3+) in synthetic zinc electrolyte containing 2x10(-3)-2x10(-1) M total iron(III) yielded results falling within +/-0.2logaFe(3+) unit of the corresponding iron speciation data calculated using the minteqa2 program.