Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
1.
J Am Coll Cardiol ; 84(1): 130-136, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38754705

RESUMO

Iatrogenic aortic dissection is a rare but life-threatening complication of coronary artery bypass surgery. We report a case with incidentally detected iatrogenic aortic dissection related to aorta cross-clamping that was successfully managed with watchful follow-up. The decision making was based on 3-dimensional holographic and fluid dynamic analysis guidance.


Assuntos
Dissecção Aórtica , Ponte de Artéria Coronária , Holografia , Doença Iatrogênica , Imageamento Tridimensional , Humanos , Dissecção Aórtica/etiologia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Holografia/métodos , Ponte de Artéria Coronária/efeitos adversos , Masculino , Tomografia Computadorizada por Raios X , Idoso , Hidrodinâmica , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Feminino
2.
Eur Heart J ; 45(20): 1804-1815, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38583086

RESUMO

BACKGROUND AND AIMS: In patients with three-vessel disease and/or left main disease, selecting revascularization strategy based on coronary computed tomography angiography (CCTA) has a high level of virtual agreement with treatment decisions based on invasive coronary angiography (ICA). METHODS: In this study, coronary artery bypass grafting (CABG) procedures were planned based on CCTA without knowledge of ICA. The CABG strategy was recommended by a central core laboratory assessing the anatomy and functionality of the coronary circulation. The primary feasibility endpoint was the percentage of operations performed without access to the ICA. The primary safety endpoint was graft patency on 30-day follow-up CCTA. Secondary endpoints included topographical adequacy of grafting, major adverse cardiac and cerebrovascular (MACCE), and major bleeding events at 30 days. The study was considered positive if the lower boundary of confidence intervals (CI) for feasibility was ≥75% (NCT04142021). RESULTS: The study enrolled 114 patients with a mean (standard deviation) anatomical SYNTAX score and Society of Thoracic Surgery score of 43.6 (15.3) and 0.81 (0.63), respectively. Unblinding ICA was required in one case yielding a feasibility of 99.1% (95% CI 95.2%-100%). The concordance and agreement in revascularization planning between the ICA- and CCTA-Heart Teams was 82.9% with a moderate kappa of 0.58 (95% CI 0.50-0.66) and between the CCTA-Heart Team and actual treatment was 83.7% with a substantial kappa of 0.61 (95% CI 0.53-0.68). The 30-day follow-up CCTA in 102 patients (91.9%) showed an anastomosis patency rate of 92.6%, whilst MACCE was 7.2% and major bleeding 2.7%. CONCLUSIONS: CABG guided by CCTA is feasible and has an acceptable safety profile in a selected population of complex coronary artery disease.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Doença da Artéria Coronariana , Estudos de Viabilidade , Humanos , Ponte de Artéria Coronária/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estudos Prospectivos , Grau de Desobstrução Vascular/fisiologia
3.
Med Phys ; 51(3): 1754-1762, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37698346

RESUMO

BACKGROUND: Breast microcalcifications (MCs) are considered to be a robust marker of breast cancer. A machine learning model can provide breast cancer diagnosis based on properties of individual MCs - if their characteristics are captured at high resolution and in 3D. PURPOSE: The main purpose of the study was to explore the impact of image resolution (8 µm, 16 µm, 32 µm, 64 µm) when diagnosing breast cancer using radiomics features extracted from individual high resolution 3D micro-CT MC images. METHODS: Breast MCs extracted from 86 female patients were analyzed at four different spatial resolutions: 8 µm (original resolution) and 16 µm, 32 µm, 64 µm (simulated image resolutions). Radiomic features were extracted at each image resolution in an attempt, to find a compact feature signature allowing to distinguish benign and malignant MCs. Machine learning algorithms were used for classifying individual MCs and samples (i.e., patients). For sample diagnosis, a custom-based thresholding approach was used to combine individual MC results into sample results. We conducted classification experiments when using (a) the same MCs visible in 8 µm, 16 µm, 32 µm, and 64 µm resolution; (b) the same MCs visible in 8 µm, 16 µm, and 32 µm resolution; (c) the same MCs visible in 8 µm and 16 µm resolution; (d) all MCs visible in 8 µm, 16 µm, 32 µm, and 64 µm resolution. Accuracy, sensitivity, specificity, AUC, and F1 score were computed for each experiment. RESULTS: The individual MC results yielded an accuracy of 77.27%, AUC of 83.83%, F1 score of 77.25%, sensitivity of 80.86%, and specificity of 72.2% at 8 µm resolution. For the individual MC classifications we report for the F1 scores: a 2.29% drop when using 16 µm instead of 8 µm, a 4.01% drop when using 32 µm instead of 8 µm, a 10.69% drop when using 64 µm instead of 8 µm. The sample results yielded an accuracy and F1 score of 81.4%, sensitivity of 80.43%, and specificity value of 82.5% at 8 µm. For the sample classifications we report for F1 score values: a 6.3% drop when using 16 µm instead of 8 µm, a 4.91% drop when using 32 µm instead of 8 µm, and a 6.3% drop when using 64 µm instead of 8 µm. CONCLUSIONS: The highest classification results are obtained at the highest resolution (8 µm). If breast MCs characteristics could be visualized/captured in 3D at a higher resolution compared to what is used nowadays in digital mammograms (approximately 70 µm), breast cancer diagnosis will be improved.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Calcinose , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Microtomografia por Raio-X , Mamografia/métodos , Calcinose/diagnóstico por imagem
4.
J Cardiovasc Comput Tomogr ; 18(2): 120-136, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37923578

RESUMO

BACKGROUND: Since the initial attempt to adapt the anatomical SYNTAX score (aSS) to coronary computed tomography angiography (CCTA), CCTA imaging technology has evolved, and is currently used as a "decision-maker" for revascularization strategy in complex coronary artery disease (CAD) and has rendered necessary some updating of the aSS to the CCTA modality. OBJECTIVES: The aim is to provide updated definitions of the aSS derived from CCTA in patients with complex CAD undergoing CABG. METHODS: The modifications of CCTA-aSS are the following; (i) updated definition and detection criteria of total occlusion (TO) in CCTA based on length assessment, (ii) inclusion of scoring points for serial bifurcations located in one single coronary segment. (iii) inclusion of weighing score points for lesions located distal to a TO, not visualized on conventional coronary angiography, but visible in CCTA, (iv) removal of thrombus and bridging collateral items from the weighing score, considering the limited diagnostic capability of CCTA in detecting these specific lesion characteristics. RESULTS: the updated CCTA-aSS was tested in a first-in-man study using the sole guidance of CCTA for the planning and performance of bypass surgery in complex CAD (n â€‹= â€‹114). An interobserver analysis showed excellent reproducibility (ICC â€‹= â€‹0.96, 95 â€‹% confidence interval 0.94-0.97). CONCLUSION: The updated CCTA-aSS was implemented in a cohort of patients with complex CAD undergoing CABG with the sole guidance of CCTA and FFRCT and the Inter-reproducibility of the analysis of the updated score was found excellent. The prognostic value of the modified CCTA-aSS will be examined in future studies.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia por Tomografia Computadorizada , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
5.
Int J Cardiovasc Imaging ; 39(12): 2531-2543, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37921898

RESUMO

To describe the updated coronary computed tomographic angiography (CCTA)-based coronary artery bypass graft (CABG) anatomic SYNTAX Score (aSS) and assess its utility and reproducibility for assessing the completeness of revascularization after CABG. The CCTA-CABG aSS is a visual assessment using CCTA post-CABG which quantifies the failure in effectively grafting stenotic coronary segments, and therefore assesses the completeness of surgical revascularization. It is calculated by subtracting the aSS of successfully anastomosed coronary segments from the aSS of the native coronary tree. The inter-observer reproducibility of the CCTA-CABG aSS was evaluated in 45 consecutive patients with three-vessel disease with or without left main disease who underwent a CCTA 30 days (± 7 days) after CABG. The CCTA-CABG aSS was evaluated in 45 consecutive patients with 117 bypass grafts and 152 anastomoses. The median native coronary aSS was 35.0 [interquartile range (IQR) 27.0-41.0], whilst the median CCTA-CABG aSS was 13.0 (IQR 9.0-20.5). The inter-observer level of agreement for the native coronary aSS and the CCTA-CABG aSS were both substantial with respective Kappas of 0.67 and 0.61. The CCTA-CABG aSS was feasible in all patients who underwent CABG for complex coronary artery disease with substantial inter-observer reproducibility, and therefore can be used to quantify the completeness of revascularization after CABG.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Ponte de Artéria Coronária/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
6.
Thyroid Res ; 16(1): 33, 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37592295

RESUMO

BACKGROUND: The literature considers sclerotherapy to be a safe and effective treatment for benign thyroid cysts. No subsequent diagnostic problems have been reported as a complication. We report the occurrence of focal inflammation after said therapy, mimicking a thyroid malignancy. CASE PRESENTATION: We report a case of a young male with a solitary strongly suspicious lesion in the thyroid. The patient had undergone prior sclerotherapy of a thyroid cyst with Doxycycline. The lesion appeared to be a focal area of inflammation and thus iatrogenic in nature. Systemic use of doxycycline is known to sometimes cause a non-immune chemical thyroiditis, dubbed as black thyroid due to the intense black discoloration of the thyroid. It might be that the instillation of doxycycline was responsible for a similar, more localized area of thyroiditis. CONCLUSIONS: For the work-up of a solitary suspicious thyroid lesion, the medical history of the patient should always be considered. In case of prior ipsilateral sclerotherapy, a reactive inflammatory response may mimic thyroid malignancy. A fine needle aspiration should be performed to exclude thyroid cancer. Treatment is not necessary; the process appears to be self-limiting as evidenced in the follow-up of this case.

7.
Eur Radiol Exp ; 7(1): 44, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37491549

RESUMO

Critical limb ischemia is associated with high mortality and major amputations. Intra-arterial digital subtraction angiography (IADSA) has been the reference standard but has some shortcomings including the two-dimensional projection and the lack of tissue perfusion information. The aim of this exploratory study is to examine four-dimensional computed tomography (4DCT) angiography and perfusion imaging using low-volume intra-arterial contrast injections for an improved anatomic and hemodynamic assessment in patients with foot ulcers. Three patients underwent a low-volume (2 mL) intra-arterial contrast-enhanced 4DCT examination combined with a diagnostic IADSA. An automated assessment of blood flow and tissue perfusion from the 4DCT data was performed. Vascular structures and corresponding blood flows were successfully assessed and correlated well with the IADSA results. Perfusion values of the affected tissue were significantly higher compared to the unaffected tissue. The proposed 4DCT protocol combined with the minimal usage of contrast agent (2 mL) provides superior images compared to IADSA as three phases (arterial, perfusion, and venous) are captured. The obtained parameters could allow for an improved diagnosis of critical limb ischemia as both the proximal vasculature and the extent of the perfusion deficit in the microvasculature can be assessed.Relevance statementIntra-arterial 4DCT allows for assessing three phases (arterial, perfusion and venous) using minimal contrast (2 mL). This method could lead to an improved diagnosis of critical limb ischemia as both proximal vasculature and the extent of the perfusion deficit are assessed.Trial registrationISRCTN, ISRCTN95737449. Registered 14 March 2023-retrospectively registered, https://www.isrctn.com/ISRCTN95737449 Key points• Three phases (arterial, perfusion, and venous) are obtained from 2 mL intra-arterial 4DCT.• The obtained hemodynamic parameters correlated well with the IADSA findings.• 4DCT surpassed IADSA in terms of assessment of venous blood flow and inflammatory hyperperfusion.• The assessment of tissue perfusion could lead to optimizing the revascularization strategy.


Assuntos
Diabetes Mellitus , Pé Diabético , Humanos , Pé Diabético/diagnóstico por imagem , Tomografia Computadorizada Quadridimensional , Isquemia Crônica Crítica de Membro , Hemodinâmica , Perfusão
8.
Acta Radiol ; 64(8): 2387-2392, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37138465

RESUMO

BACKGROUND: Iodine contrast agent (CA) is widely used in cardiac computed tomography (CT). The CA can increase the organ radiation doses due to the photoelectric effect. PURPOSE: To investigate the impact of CA on radiation dose in cardiac CT by comparing the radiation dose between contrast coronary CT angiography (CCTA) and non-contrast calcium scoring CT (CSCT). MATERIAL AND METHODS: Radiation doses were computationally calculated for 30 individual patients who received CSCT and CCTA in the same exam session. The geometry and acquisition parameters were modeled in the simulations based on individual patient CT images and acquisitions. Doses in the presence and absence of CA were obtained in the aorta, left ventricle (LV), right ventricle (RV), and myocardial tissue (MT). The dose values were normalized by size-specific dose estimate (SSDE). The dose enhancement factors (DEFSSDE) were calculated as the ratio of doses in CCTA over doses in CSCT. RESULTS: Compared to the CSCT scans, doses increase in the CCTA scans in the aorta (DEFSSDE = 2.14 ± 0.20), LV (DEFSSDE = 1.78 ± 0.26), and RV (DEFSSDE = 1.31 ± 0.22). A linear relation is observed between the local CA concentrations and the dose increase in the heart; DEFSSDE = 0.07*I(mg/mL) + 0.80 (R2 = 0.8; p < 0.01). The DEFSSDE in the MT (DEFSSDE = 0.96 ± 0.08) showed no noticeable impact of CA on the dose in this tissue. In addition, patient variability in the dose distributions was observed. CONCLUSION: A linear causal relation exists between local CA concentration and increase in radiation dose in cardiac CT. For the same CT exposure, dose to the heart is on average 55% higher in contrast cardiac CT.


Assuntos
Cálcio , Meios de Contraste , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
9.
Biomed Phys Eng Express ; 9(3)2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-36975189

RESUMO

Objective.To test and compare different intensity standardization approaches for whole-body multi-parametric MR images, aiming to compensate voxel intensity differences between scans. These differences, common for magnetic resonance imaging, pose problems in image quantification, assessment of changes between a baseline and follow-up scan, and hinder performance of image processing and machine learning algorithms.Approach.In this work, we present a comparison on the accuracy of intensity standardization approaches with increasing complexity, for intra- and inter-patient multi-parametric whole-body MRI. Several approaches were used: z-scoring of the intensities, piecewise linear mapping and deformable mapping of intensity distributions into established reference intensity space. For each method, the impact on standardization algorithm on the use of single image or average population distribution reference; as well as, whole image and region of interest were additionally investigated. All methods were validated on a data set of 18 whole-body anatomical and diffusion-weighted MR scans consisting of baseline and follow-up examinations acquired from advanced prostate cancer patients and healthy volunteers.Main results.The piecewise linear intensity standardisation approach provided the best compromise between standardization accuracy and method stability, with average deviations in intensity profile of 0.011-0.027 and mean absolute difference of 0.29-0.37 standard score (intra-patient) and 0.014-0.056 (inter-patient), depending on the type of used MR modality.Significance.Linear piecewise approaches showed the overall best performance across multiple validation metrics, mostly because of its robustness. The inter-patient standardization proved to perform better when using population average reference image; in contrary to intra-patient approach, where the best results were achieved by standardizing towards a reference image taken as the baseline scan.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Padrões de Referência , Algoritmos , Aprendizado de Máquina
10.
Cardiovasc Revasc Med ; 50: 34-40, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36639338

RESUMO

BACKGROUND: Personalized long term vital prognosis plays a key role in deciding between percutaneous coronary intervention (PCI) and CABG in patients with complex coronary artery disease. The FASTTRACK CABG trial enrolls patients with the sole guidance of coronary computed tomographic angiography (CCTA) and fractional flow reserve CCTA (FFRCT). The feasibility/non-feasibility of this approach is determined by the surgeon request to have access to the invasive coronary angiography. METHODS: This interim analysis, which was requested by the Data and Safety Monitoring Board (DSMB), compared the treatment decision of the "on site" Heart team to the recommended treatment as per the SYNTAX Score II 2020 (SS-2020), which was prospectively assessed by the central core laboratory in the first 57 consecutive patients (half of the planned population) enrolled in this First in Man study. RESULTS: The average anatomical SYTAX Score is 35.6 ± 11.5. The SS-2020 predicted 5-year MACE and 10-year all-cause mortality are 14.7 % and 21.6 % following CABG, and 23.0 % and 30.4 % following PCI. Among the enrolled patients the SS-2020 predicts long-term PCI outcomes similar to CABG (absolute risk difference ≤0 % in favor of PCI) in only two patients whilst the remaining 55 patients had a predicted survival benefit with CABG. CONCLUSIONS: According to the SS-2020, the first 57 patients recruited into the FASTTRACK CABG trial received the appropriate modality of revascularization and the DSMB allowed the investigators to complete the study.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Ponte de Artéria Coronária , Seleção de Pacientes , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
11.
J Appl Clin Med Phys ; 24(1): e13867, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36537145

RESUMO

BACKGROUND: Unoptimized coronary CT angiography (CTA) exams typically result in a highly variable arterial enhancement (HUa ) across patients. This study aimed at harmonizing arterial enhancement by implementing a patient-, contrast- and kV-tailored injection protocol. METHODS: First, the optimal body size metric to predict HUa was identified by retrospectively analysing images of 76 patients, acquired with 70 ml contrast media (G1). Second, using phantom experiments, correction factors for the effect of kV and contrast concentration on HUa were determined. Third, a model was developed, prescribing the optimal contrast dose to be injected to obtain a diagnostically appropriate arterial target enhancement HUtarget . The model was then validated on 278 prospectively collected patients, in two groups with two different HUtarget : 525 HU (207 patients, G2A) and 425 HU (71 patients, G2B). The HUa histograms were compared among groups and to the target enhancement through their mean and standard deviation (SD) at 100 kVp reference level. Also, signal-to-noise ratio was obtained and compared among the groups. RESULTS: Fat free mass (FFM) showed the highest correlation with HUa (r = 0.69). KVp correction factors ranged from 0.65 at 70 kVp to 1.22 at 140 kVp. The obtained model reduced the group heterogeneity (SD) from 101HU for reference G1 to 75HU (p < 0.001) for G2A and 68HU (p < 0.001) for G2B. The mean HUa of 506HU in G2A was slightly below HUtarget  = 525HU (p = 0.01) whereas in G2B, the mean HUa of 414HU was not significantly different from HUtarget  = 425HU (p = 0.54). The total iodine dose was lowered from 19.5 g-I to 17.6 g-I and 14.2 g-I from G1 to G2A and G2B, on average. CONCLUSION: A contrast injection model, based on patient's fat free mass and accounting for the contrast agent concentration and the planned CT-scan tube voltage, harmonized arterial enhancement among patients towards a predefined target enhancement in coronary CTA scanning, without affecting the bolus timing.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Doses de Radiação
12.
Eur Heart J Cardiovasc Imaging ; 24(7): 972-981, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-36562390

RESUMO

AIMS: To identify predictors of individual late pulmonary vein (PV) reconnection after second-generation cryoballoon (CB2) ablation. Anatomic indicators of late pulmonary vein reconnection (LPVR) post-CB2 ablation have not yet been studied on an individual PV level, nor weighed against clinical and procedural factors. METHODS AND RESULTS: Clinical, procedural, and PV anatomic data from 125 patients with a repeat procedure for arrhythmia recurrence after index CB2 ablation were analyzed. Preprocedural computed tomography (CT) evaluated 486 PVs for measurement of size; shape (ovality index); carina width; and orientation angle in frontal (superior/inferior) and transversal (anterior/posterior) plane (with horizontal line 0° as reference and upper/lower half circle as positive/negative value, respectively). Durable isolation in all PVs was demonstrated in 50/125 (40%) patients. Late reconnection rates at the different PVs were as follows: 16% left superior (LS), 12% left inferior (LI), 17% right superior (RS), and 31% right inferior (RI) PV. Multivariable analysis performed per vein showed following independent determinants predicting LPVR: ovality index [odds ratio (OR) 1.61, 95% confidence interval (CI) 1.07-2.41, P = 0.022] and carina width (OR 0.75, CI 0.59-0.96, P = 0.024) for LSPV; carina width (OR 0.71, CI 0.53-0.95, P = 0.020) for LIPV; frontal angle (OR 0.91, CI 0.87-0.95, P < 0.001) for RIPV; and transversal angle (OR 1.15, CI 1.03-1.31, P = 0.032) for RSPV. CONCLUSION: Cardiac CT-based evaluation of anatomic PV characteristics presented higher predictive value compared to clinical and procedural variables for individual LPVR after CB2 ablation. Pre-procedural identification of unfavourable PV anatomy might be important to tailor the ablation approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Recidiva , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
13.
J Belg Soc Radiol ; 106(1): 69, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35936106

RESUMO

We studied the US imaging findings of lipomatosis of nerve and macrodystrophia lipoma in three patients. Three patients were seen at three affiliated institutions with an enlarged digit. They all underwent US, subsequently followed by an MRI study. The nerves showed marked enlargement and extension over a length of 9-16 cm. Digital branches were always involved. The appearance on cross section was an enlarged hyperechoic endoneurium with inlying thickened and hypoechoic fascicles. On transverse images this resulted in a 'chocolate cookie' aspect and in the long axis a 'spaghetti-like' image. The US appearance of lipomatosis of nerve, not unlike MRI, is rather typical. With US, care should be taken in areas that are more difficult to assess as the sole of the foot, or where the 'chocolate cookie' appearance is not so obvious, such as the digits.

14.
Int J Biomed Imaging ; 2022: 2984789, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35646108

RESUMO

A multiphase 4DCT technique can be useful for the detection of parathyroid adenomas. Up to 16 different phases can be obtained without significant increase of exposure dose using wide beam axial scanning. This technique also allows for the calculation of perfusion parameters in suspected lesions. We present data on 19 patients with histologically proven parathyroid adenomas. We find a strong correlation between 2 perfusion parameters when comparing parathyroid adenomas and thyroid tissue: parathyroid adenomas show a 55% increase in blood flow (BF) (p < 0.001) and a 50% increase in blood volume (BV) (p < 0.001) as compared to normal thyroid tissue. The analysis of the ROC curve for the different perfusion parameters demonstrates a significantly high area under the curve for BF and BV, confirming these two perfusion parameters to be a possible discriminating tool to discern between parathyroid adenomas and thyroid tissue. These findings can help to discern parathyroid from thyroid tissue and may aid in the detection of parathyroid adenomas.

15.
Case Rep Radiol ; 2022: 2953579, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35535304

RESUMO

Dermatofibrosarcoma protuberans is a low-grade cutaneous sarcoma typically located on the trunk or proximal extremities. Less common locations include the head, face, and neck area. This tumour is slow growing with variable clinical appearance. It is known for its locally invasive nature and low metastatic propensity. Because imaging findings are rather nonspecific, biopsy is needed for definite diagnosis. This case describes an unusually large example of dermatofibrosarcoma protuberans in the less common preauricular region.

16.
Eur J Radiol ; 150: 110227, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35344915

RESUMO

PURPOSE: To determine the normal thickness and MRI appearance of the Tibialis Posterior Tendon near the navicular insertion in normal volunteers. MATERIALS AND METHODS: By using a 3T MRI system 41 ankles were imaged, and PD weighted images with fat saturation were acquired in the three orthogonal planes. Symptoms of tendon pathology and history of trauma or surgery of the tendon were used as volunteer exclusion criteria. Two different measurement points were determined to evaluate hyperintensity and thickness. Two radiologists assessed the internal signal of the Tibialis Posterior Tendon independently by using axial and coronal images. Tendon hyperintensity was classified from homogenously dark to different degrees of hyperintense signal, where 0 means no internal hyperintensity, 1 - minimal hyperintensity, 2 - moderate and 3 - marked. Correlations between the two observers were obtained by Cohen's kappa. Descriptive statistics were also obtained. RESULTS: Eight men and 13 women (total 21) volunteers, age range 19-43(average 24.7)years were included in the study. At measurement point-1 on the coronal images, observer-1 and observer-2 evaluated hyperintensity (mostly minimal) respectively in 90.5% and 95.3% of tendons with a Cohen's kappa coefficient of 0.701 (moderate agreement) for the right foot and in 60% and 70% of tendons with a Cohen's kappa coefficient of 0.624 (moderate agreement) for the left foot. On axial images both observers assessed hyperintensity (mostly marked) in 100% of the tendons with a coefficient of 0.763 (moderate agreement) for the right foot, and in 95% of tendons with a coefficient of 0.839 (strong agreement) for the left foot. At measurement point-2 on coronal images, both observers rated any degree of hyperintensity in 33.3% of tendons with a coefficient of 1.00 (perfect agreement) for the right foot, in 38.9% of tendons with a coefficient of 0.766 (moderate agreement) for the left foot. On axial images both observers evaluated hyperintensity (mostly minimal) in 100% of tendons with a kappa coefficient of 0.702 (moderate agreement) for the right foot, in 95% of tendons with a coefficient of 0.790 (moderate- to strong agreement) for the left foot. CONCLUSION: The Tibialis Posterior Tendon, near the navicular insertion (navicular tendon and tarsometatarsal tendon), exhibits an apparent thickening and most importantly hyperintensity which should be regarded as a normal finding, and not lead to an erroneous diagnosis of tendinopathy. This observation was almost always the case for the navicular insertion and less so for the tarsometatarsal tendon.


Assuntos
Tendinopatia , Tendões , Adulto , Feminino , Pé/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Tendões/diagnóstico por imagem , Adulto Jovem
17.
Interact Cardiovasc Thorac Surg ; 34(2): 176-184, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34542612

RESUMO

OBJECTIVES: The aim of this study was to determine Syntax scores based on coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) and to assess whether heavy coronary calcification significantly limits the CCTA evaluation and the impact of severe calcification on heart team's treatment decision and procedural planning in patients with three-vessel coronary artery disease (CAD) with or without left main disease. METHODS: SYNTAX III was a multicentre, international study that included patients with three-vessel CAD with or without left main disease. The heart teams were randomized to either assess coronary arteries with coronary CCTA or ICA. We stratified the patients based on the presence of at least 1 lesion with heavy calcification defined as arc of calcium >180° within the lesion using CCTA. Agreement on the anatomical SYNTAX score and treatment decision was compared between patients with and without heavy calcifications. RESULTS: Overall, 222 patients with available CCTA and ICA were included in this trial subanalysis (104 with heavy calcification, 118 without heavy calcification). The mean difference in the anatomical SYNTAX score (CCTA derived-ICA derived) was lower in patients without heavy calcifications [mean (-1.96 SD; +1.96 SD) = 1.5 (-19.3; 22.4) vs 5.9 (-17.5; +29.3), P = 0.004]. The agreement on treatment decision did not differ between patients with (Cohen's kappa 0.79) or without coronary calcifications (Cohen's kappa 0.84). The agreement on the treatment planning did not differ between patients with (concordance 80.3%) or without coronary calcifications (concordance 82.8%). CONCLUSIONS: An overall good correlation between CCTA- and ICA-derived Syntax score was found. The presence of heavy coronary calcification moderately influenced the agreement between CCTA and ICA on the anatomical SYNTAX score. However, agreement on the treatment decision and planning was high and irrespective of the presence of calcified lesions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Estenose Coronária/etiologia , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos
18.
Med Phys ; 48(11): 7526-7533, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34564862

RESUMO

PURPOSE: To investigate the contrast media iodine dose dependency of radiation-induced DNA double-strand breaks (DSBs) during a coronary computed tomography angiography (CCTA) scan. METHODS: This prospective patient study was approved by the ethical committee. Between November 2018 and July 2019, 50 patients (31 males and 19 females, mean age 64 years) were included in the study, 45 CCTA and five noncontrast-enhanced (NCE) cardiac computed tomography (CT) patients. A single-heartbeat scan protocol with a patient-tailored contrast media injection protocol was used, administering a patient-specific iodine dose. DNA double-strand breaks were quantified using a γH2AX foci assay on peripheral blood lymphocytes. The net amount of γH2AX/cell was normalized to the individual patient CT dose by the size-specific dose estimate (SSDE). Correlation between the administered and blood-iodine dose and the SSDE normalized amount of DNA DSBs was investigated using a Pearson correlation test. RESULTS: CCTA patients were scanned with a mean CTDIvol of 10.6 ± 5.6 mGy, corresponding to a mean SSDE of 11.3 ± 5.3 mGy while the NCE cardiac CT patients were scanned with a mean CTDIvol of 6.00 ± 1.8 mGy, corresponding to a mean SSDE of 6.6 ± 2.7 mGy. The administered iodine dose ranged from 16.5 to 34.0 gI in the CCTA patients, resulting in a blood-iodine dose range from 5.1 to 15.0 gI in the exposed blood volume. A significant linear relationship (r = 0.79, p-value < 0.001) was observed between the blood iodine dose and SSDE normalized radiation-induced DNA DSBs. A similar significant linear relationship (r = 0.62, p-value < 0.001) was observed between the administered iodine dose and SSDE normalized radiation-induced DNA DSBs. CONCLUSIONS: This study shows that contrast media iodine dose increases the level of radiation-induced DNA DSBs in peripheral blood lymphocytes in a linear dose-dependent manner with CCTA. Importantly, the level of DNA DSBs can be reduced by lowering the administered iodine dose.


Assuntos
Quebras de DNA de Cadeia Dupla , Iodo , Angiografia por Tomografia Computadorizada , Meios de Contraste , Angiografia Coronária , DNA , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
19.
J Endocr Soc ; 5(10): bvab132, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34458658

RESUMO

4-Dimensional computed tomography (4DCT) for the detection of (an) enlarged parathyroid(s) is a commonly performed examination in the management of primary hyperparathyroidism. In our center, we introduced a high-frequency multiphase 4DCT protocol obtaining 16 phases, including 11 different arterial phases. Exposure to this multiphase 4DCT technique is similar to that for classic helical 4DCT. In this pictorial essay we reconstructed our multiphase 4DCT series in the manner of a classic helical 4DCT and compare both techniques. We illustrate how multiphase 4DCT may aid in the detection of parathyroid adenomas. We found 17 out of 19 lesions demonstrating a type A pattern of enhancement, therefore suggesting this pattern could be more prevalent than previously thought. Some parathyroid adenomas may be mistaken for enlarged lymph nodes using classic 4DCT whereas high-frequency multiphase 4DCT can detect a temporary rise in enhancement, thus suggesting the lesions in question to be of parathyroid origin. Smaller lesions may prove more obvious as the difference in enhancement between parathyroid and thyroid can become more prominent. KEY POINT: Using high-frequency multiphase 4DCT an arterial phase with maximum enhancement of parathyroid tissue can be defined. This phase may aid in the detection of parathyroid adenomas.

20.
Radiol Res Pract ; 2021: 6614406, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34094599

RESUMO

OBJECTIVE: 4DCT for the detection of (an) enlarged parathyroid(s) is a commonly performed examination in the management of primary hyperparathyroidism. Protocols are often institution-specific; this review aims to summarize the different protocols and explore the reported sensitivity and specificity of different 4DCT protocols as well as the associated dose. MATERIALS AND METHODS: A literature study was independently conducted by two radiologists from April 2020 until May 2020 using the Medical Literature Analysis and Retrieval System Online (MEDLINE) database. Articles were screened and assessed for eligibility. From eligible studies, data were extracted to summarize different parameters of the scanning protocol and observed diagnostic attributes. RESULTS: A total of 51 articles were included and 56 scanning protocols were identified. Most protocols use three (n = 25) or four different phases (n = 23). Almost all authors include noncontrast enhanced imaging and an arterial phase. Arterial images are usually obtained 25-30 s after administration of contrast, and less agreement exists concerning the timing of the venous phase(s). A mean contrast bolus of 100 mL is administered at 3-4 mL/s. Bolus tracking is not often used (n = 3). A wide range of effective doses are reported, up to 28 mSv. A mean sensitivity of 81.5% and a mean specificity of 86% are reported. CONCLUSION: Many different 4DCT scanning protocols for the detection of parathyroid adenomas exist in the literature. The number of phases does not appear to affect sensitivity or specificity. A triphasic approach, however, seems preferable, as three patterns of enhancement of parathyroid adenomas are described. Bolus tracking could help to reduce the variability of enhancement. Sensitivity and specificity also do not appear to be affected by other scan parameters like tube voltage or tube current. To keep the effective dose within limits, scanning at a lower fixed tube current seems preferable. Lowering tube voltage from 120 kV to 100 kV may yield similar image contrast but would also help lower the dose.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA