Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Sci Transl Med ; 14(666): eabo3357, 2022 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-36223449

RESUMO

Substantial advances in biotherapeutics are distinctly lacking for musculoskeletal diseases. Musculoskeletal diseases are biomechanically complex and localized, highlighting the need for novel therapies capable of addressing these issues. All frontline treatment options for arthrofibrosis, a debilitating musculoskeletal disease, fail to treat the disease etiology-the accumulation of fibrotic tissue within the joint space. For millions of patients each year, the lack of modern and effective treatment options necessitates surgery in an attempt to regain joint range of motion (ROM) and escape prolonged pain. Human relaxin-2 (RLX), an endogenous peptide hormone with antifibrotic and antifibrogenic activity, is a promising biotherapeutic candidate for musculoskeletal fibrosis. However, RLX has previously faltered through multiple clinical programs because of pharmacokinetic barriers. Here, we describe the design and in vitro characterization of a tailored drug delivery system for the sustained release of RLX. Drug-loaded, polymeric microparticles released RLX over a multiweek time frame without altering peptide structure or bioactivity. In vivo, intraarticular administration of microparticles in rats resulted in prolonged, localized concentrations of RLX with reduced systemic drug exposure. Furthermore, a single injection of RLX-loaded microparticles restored joint ROM and architecture in an atraumatic rat model of arthrofibrosis with clinically derived end points. Finally, confirmation of RLX receptor expression, RXFP1, in multiple human tissues relevant to arthrofibrosis suggests the clinical translational potential of RLX when administered in a sustained and targeted manner.


Assuntos
Doenças Musculoesqueléticas , Relaxina , Animais , Preparações de Ação Retardada , Fibrose , Humanos , Doenças Musculoesqueléticas/tratamento farmacológico , Ratos , Relaxina/metabolismo , Relaxina/uso terapêutico
2.
Eur J Radiol Open ; 9: 100411, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35265737

RESUMO

Imaging plays a key role in the assessment and management of traumatic shoulder injuries, and it is important to understand how the imaging details help guide orthopedic surgeons in determining the role for surgical treatment. Imaging is also crucial in preoperative planning, the longitudinal assessment after surgery and the identification of complications after treatment. This review discusses the mechanisms of injury, key imaging findings, therapeutic options and associated complications for the most common shoulder injuries, tailored to the orthopedic surgeon's perspective.

3.
BMC Musculoskelet Disord ; 23(1): 139, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35148741

RESUMO

OBJECTIVE: Medial patellofemoral ligament (MPFL) injury occurs in the majority of the cases of acute patellar dislocation. The role of concomitant lateral retinaculum release with MPFL reconstruction is not clearly understood. Even though the lateral retinaculum plays a role in both medial and lateral patellofemoral joint stability in MPFL intact knees, studies have shown mixed clinical outcomes following its release during MPFL reconstruction surgery. Better understanding of the biomechanical effects of the release of the lateral retinaculum during MPFL reconstruction is warranted. We hypothesize that performing a lateral release concurrent with MPFL reconstruction will disrupt the patellofemoral joint biomechanics and result in lateral patellar instability. METHODS: A previously developed and validated finite element (FE) model of the patellofemoral joint was used to understand the effect of lateral retinaculum release following MPFL reconstruction. Contact pressure (CP), contact area (CA) and lateral patellar displacement were recorded. abstract. RESULTS: FE modeling and analysis demonstrated that lateral retinacular release following MPFL reconstruction with tibial tuberosity-tibial groove distance (TT-TG) of 12 mm resulted in a 39% decrease in CP, 44% decrease in CA and a 20% increase in lateral patellar displacement when compared to a knee with an intact MPFL. In addition, there was a 45% decrease in CP, 44% decrease in CA and a 21% increase in lateral displacement when compared to a knee that only had an MPFL reconstruction. CONCLUSION: This FE-based analysis exhibits that concomitant lateral retinaculum release with MPFL reconstruction results in decreased PF CA, CP and increased lateral patellar displacement with increased knee flexion, which may increase the risk of patellar instability.


Assuntos
Instabilidade Articular , Luxação Patelar , Articulação Patelofemoral , Humanos , Instabilidade Articular/cirurgia , Ligamentos Articulares , Patela , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia
4.
Arthroscopy ; 38(3): 953-964, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34411682

RESUMO

PURPOSE: The purpose of this study was to develop and validate a finite element (FE) model of the patellofemoral (PF) joint to characterize patellofemoral instability, and to highlight the effect of lateral retinacular release in combination with tibial tuberosity transfer with respect to contact pressures (CP), contact area (CA), and kinematics during knee flexion. METHODS: A comprehensive, dynamic FE model of the knee joint was developed and validated through parametric comparison of PF kinematics, CP, and CA between FE simulations and in vitro, cadaveric experiments. Using this FE model, we characterized the effect of patellar instability, lateral retinacular release (LR), and tibial tuberosity transfer (TTT) in the setting of medial patellofemoral ligament injury during knee flexion. RESULTS: There was a high level of agreement in CP, CA, lateral patellar displacement, anterior patellar displacement, and superior patellar displacement between the FE model and the in vitro data (P values 0.19, 0.16, 0.81, 0.10, and 0.36, respectively). Instability conditions demonstrated the greatest CP compared to all of the other conditions. During all degrees of flexion, TTT and concomitant lateral release (TTT + LR) decreased CP significantly. TTT alone shows a consistently lower CA compared to nonrelease conditions with subsequent lateral release further decreasing CA. CONCLUSIONS: The results of this study demonstrate that the FE model described reliably simulates PF kinematics and CP within 1 SD in uncomplicated cadaveric specimens. The FE model is able to show that tibial tubercle transfer in combination with lateral retinacular release markedly decreases patellofemoral CP and CA and increases lateral patellar displacement that may decrease bony stabilization of the patella within the trochlear groove and promote lateral patellar instability. CLINICAL RELEVANCE: The goal of surgical correction for patellar instability focuses on reestablishing normal PF kinematics. By developing an FE model that can demonstrate patient PF kinematics and the results of different surgical approaches, surgeons may tailor their treatment to the best possible outcome. Of the surgical approaches that have been described, the biomechanical effects of the combination of TTT with lateral retinacular release have not been studied. Thus, the FE analysis will help shed light on the effect of the combination of TTT with lateral retinacular release on PF kinematics.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Modelos Anatômicos , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Tíbia/cirurgia
5.
Am J Sports Med ; 48(9): 2252-2259, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32551965

RESUMO

BACKGROUND: There is a lack of evidence regarding the optimum extensor-sided fixation method for medial patellofemoral ligament (MPFL) reconstruction. There is increased interest in avoiding patellar drilling via soft tissue-only fixation to the distal quadriceps, thus reconstructing the medial quadriceps tendon-femoral ligament (MQTFL). The biomechanical implications of differing extensor-sided fixation constructs remain unknown. HYPOTHESIS: The null hypothesis was there would be no differences between traditional MPFL reconstruction and MQTFL reconstruction with respect to resistance to lateral translation, patellar position, or patellofemoral contact pressures. STUDY DESIGN: Controlled laboratory study. METHODS: Nine adult knee specimens were mounted on a jig that applied static, physiologic loads to the quadriceps tendons. Patellar position and orientation, knee flexion angle, and patellofemoral pressure were recorded at 8 different flexion angles between 0° and 110°. Additionally, a lateral patellar excursion test was conducted wherein a load was applied directly to the patella in the lateral direction with the knee at 30° of flexion and subjected to 2-N quadriceps loads. Testing was conducted under 4 conditions: intact, transected MPFL, MQTFL reconstruction, and MPFL reconstruction. For MQTFL reconstruction, the surgical technique established by Fulkerson was employed. For MPFL reconstruction, a traditional technique was utilized. RESULTS: The patellar excursion test showed no significant difference between the MQTFL and intact states with respect to lateral translation. MPFL reconstruction led to significantly less lateral translation (P < .05) than all other states. There were no significant differences between MPFL and MQTFL reconstructions with respect to peak patellofemoral contact pressure. MPFL and MQTFL reconstructions both resulted in increased internal rotation of the patella with the knee in full extension. CONCLUSION: Soft tissue-only extensor-sided fixation to the distal quadriceps (MQTFL) during patella stabilization appears to re-create native stability in this time 0 cadaver model. Fixation to the patella (MPFL) was associated with increased resistance to lateral translation. CLINICAL RELEVANCE: Evolving anatomic knowledge and concern for patellar fracture has led to increased interest in MQTFL reconstruction. Both MQTFL and MPFL reconstructions restored patellofemoral stability to lateral translation without increasing contact pressures under appropriate graft tensioning, with MQTFL more closely restoring native resistance to lateral translation at the time of surgery.


Assuntos
Ligamentos Articulares/cirurgia , Articulação Patelofemoral , Tendões/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Pessoa de Meia-Idade , Patela , Articulação Patelofemoral/cirurgia
6.
Injury ; 50(4): 926-930, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30885393

RESUMO

INTRODUCTION: Implant cut-out remains a common cause of cephalomedullary nail (CMN) failure and patient morbidity following surgical treatment of intertrochanteric femur fractures. Recent studies have suggested an increased rate of CMN cut-out with helical blades as opposed to lag screws. We compared rates of overall cut-out between helical blades and lag screws and used bivariate and multivariate analysis to determine the role of proximal fixation method among other variables on risk for cut-out. Subgroup analysis was performed on the basis of failure mechanism; superior migration (Fig. 2) versus medial perforation (Fig. 3). METHODS: Three-hundred and thirteen patient charts were retrospectively reviewed over an 8-year period; 245 patients were treated with helical blades and 68 with lag screws. Radiographs were reviewed for fracture pattern, Tip-Apex Distance (TAD), Parker's Ratio (PR) and reduction quality. Rate of implant cut-out was compared between groups and multiple logistic regression was used to analyze the ability of several independent variables to predict implant cut-out. RESULTS: Twenty cut-outs occurred; 15 with helical blades and 5 with lag screws. No difference in the rate of cut-out was observed between the two groups (p = 0.45). Poor fracture reduction was found to be a significant predictor of implant failure via bivariate and multiple logistic regression analysis (p = <0.01, OR 23.573). Helical blade fixation, fracture instability, TAD ≥ 25, and PR ≥ 0.45 were not predictive of implant cut-out during multivariate analysis. Similarly, patient smoking status and surgeon trauma fellowship training did not significantly increase the odds of implant cut-out. Failure by medial perforation occurred in 12 instances, all involving helical blades. Failure by superior migration occurred at a significantly higher rate with lag screws than helical blades (p = 0.02). CONCLUSION: CMN cutout is likely multifactorial. A direct association between helical blade fixation and implant cut-out was not observed in our study. Amongst modifiable risk factors for implant failure, poorer fracture reduction was predictive of failure by cut-out. Subgroup analysis highlights differing modes of failure between lag screws and helical blades which warrants further investigation. Ideal TAD during helical blade fixation remains unknown.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos/efeitos adversos , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Estudos Retrospectivos
7.
J Biomech ; 82: 280-290, 2019 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-30514628

RESUMO

BACKGROUND: Numerous biomechanical studies have addressed normal shoulder function and the factors that affect it. While these investigations include a mix of in-vivo clinical reports, ex-vivo cadaveric studies, and computer-based simulations, each has its own strengths and limitations. A robust methodology is essential in cadaveric work but does not always come easily. Precise quantitative measurements are difficult in in-vivo studies, and simulation studies require validation steps. This review focuses on ex-vivo cadaveric studies to emphasize the best research methodologies available to simulate physiologically and clinically relevant shoulder motion. METHODS: A PubMed and Web of Science search was conducted in March 2017 (and updated in May 2018) to identify the cadaveric studies focused on the shoulder and its function. The key words for this search included rotator cuff (RC) injuries, RC surgery, and their synonyms. The protocol of the study was registered on PROSPERO and is accessible at CRD42017068873. RESULTS: Thirty one studies consisting of 167 specimens with various biomechanical methods met our inclusion criteria. All studies were level V cadaveric studies. Cadaveric biomechanical models are widely used to study shoulder instability and RC repair. These models are commonly limited to the glenohumeral joint by a fixed scapula, passively and discretely move the humerus, and statically load the RC without regard for the integrity of the glenohumeral capsule. CONCLUSION: All studies captured in this review evaluated shoulder biomechanics. Recent studies in patients suggest that some assumptions made in this space may not fully characterize motion of the human shoulder. With reproducible scapular positioning, dynamic RC activation, and preservation of glenohumeral capsule integrity, cadaveric studies can facilitate proper validation for simulation models and broaden our understanding of the shoulder environment during motion in healthy and disease states.


Assuntos
Fenômenos Mecânicos , Manguito Rotador/fisiopatologia , Manguito Rotador/cirurgia , Ombro/fisiopatologia , Fenômenos Biomecânicos , Cadáver , Humanos
8.
BMJ Open Sport Exerc Med ; 4(1): e000212, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29682310

RESUMO

OBJECTIVE: To review existing biomechanical and clinical evidence regarding postoperative weight-bearing and range of motion restrictions for patients following meniscal repair surgery. METHODS AND DATA SOURCES: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline, we searched MEDLINE using following search strategy: (((("Weight-Bearing/physiology"[Mesh]) OR "Range of Motion, Articular"[Mesh]) OR "Rehabilitation"[Mesh])) AND ("Menisci, Tibial"[Mesh]). Additional articles were derived from previous reviews. Eligible studies were published in English and reported a rehabilitation protocol following meniscal repair on human. We summarised rehabilitation protocols and patients' outcome among original studies. RESULTS: Seventeen clinical studies were included in this systematic review. There was wide variation in rehabilitation protocols among clinical studies. Biomechanical evidence from small cadaveric studies suggests that higher degrees of knee flexion and weight-bearing may be safe following meniscal repair and may not compromise the repair. An accelerated protocol with immediate weight-bearing at tolerance and early motion to non-weight-bearing with immobilising up to 6 weeks postoperatively is reported. Accelerated rehabilitation protocols are not associated with higher failure rates following meniscal repair. CONCLUSIONS: There is a lack of consensus regarding the optimal postoperative protocol following meniscal repair. Small clinical studies support rehabilitation protocols that allow early motion. Additional studies are needed to better clarify the interplay between tear type, repair method and optimal rehabilitation protocol.

9.
J Shoulder Elbow Surg ; 26(4): 669-673, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27765501

RESUMO

BACKGROUND: Computed tomography (CT) scan is the standard for the preoperative assessment of glenoid version and morphology before total shoulder arthroplasty. However, the capacity of magnetic resonance imaging (MRI) to visualize bone morphology has improved with advancing technology. The purpose of this study was to compare the accuracy of MRI to CT for assessment of glenoid version and Walch classification. METHODS: Three fellowship-trained shoulder surgeons assessed glenoid version and Walch classification of 30 patients with primary shoulder osteoarthritis who received both CT and MRI scans before total shoulder arthroplasty. Version measurements, Walch classification, and observer agreement were compared. RESULTS: Mean glenoid version was -15.5° and -18.6° by CT and MRI, respectively (P = .17). Interobserver reliability coefficients were good for both imaging modalities (CT, 0.73; MRI, 0.62). Intraobserver coefficients were good to excellent for CT (range, 0.76-0.87) and good for MRI (range, 0.75-0.79). For Walch classification, interobserver reliability for both modalities was merely fair, whereas intraobserver reliability was moderate to good. Although identification of type A1, A2, and B1 was nearly identical between CT and MRI, there was observer disagreement on type B2 (P = .001) and C glenoids (P = .03). Specifically, MRI underidentified type B2 and overidentified type C compared with CT. CONCLUSIONS: MRI is largely comparable to CT scan for evaluation of the glenoid, with similar measurements of version and identification of less extreme Walch glenoids. However, MRI is less accurate at distinguishing between type B2 and C glenoids.


Assuntos
Cavidade Glenoide/diagnóstico por imagem , Imageamento por Ressonância Magnética , Osteoartrite/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Artroplastia do Ombro , Humanos , Variações Dependentes do Observador , Osteoartrite/cirurgia , Reprodutibilidade dos Testes , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X/métodos
10.
Arthroscopy ; 33(3): 617-624, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27956232

RESUMO

PURPOSE: To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. METHODS: Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). RESULTS: The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P < .03). There was approximately a 70% increase in contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P < .05). Partial meniscectomy and subtotal meniscectomy significantly increased average peak contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P < .05). CONCLUSIONS: The presence of a horizontal cleavage tear in the medial meniscus causes a significant reduction in contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. CLINICAL RELEVANCE: Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology.


Assuntos
Articulação do Joelho/fisiopatologia , Meniscos Tibiais/fisiopatologia , Lesões do Menisco Tibial/fisiopatologia , Lesões do Menisco Tibial/cirurgia , Idoso , Fenômenos Biomecânicos/fisiologia , Cadáver , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Meniscos Tibiais/cirurgia , Pressão , Amplitude de Movimento Articular/fisiologia , Estresse Mecânico
11.
Arthroscopy ; 31(3): 428-34, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25442653

RESUMO

PURPOSE: A device for all-inside suture-based meniscal repairs has been introduced (NovoStitch; Ceterix, Menlo Park, CA) that passes the suture vertically through the meniscus, thereby encircling the tear, and does not require an additional incision or extra-capsular anchors. Our aim was to compare this all-inside suture-based repair with an inside-out suture repair and an all-inside anchor-based repair (FasT-Fix 360°; Smith & Nephew, Andover, MA). METHODS: Longitudinal tears were created in 36 fresh-frozen porcine menisci. Repairs were performed using an all-inside suture-based meniscal repair device, an all-inside anchor-based repair, and an inside-out suture repair. They were tested with cyclic loading and load-to-failure testing. The displacement, response to cyclic loading (100, 300, and 500 cycles), and mode of failure were recorded. The stiffness of the constructs was calculated as well. RESULTS: The all-inside suture-based repairs and the inside-out repairs showed significantly higher loads to failure than the all-inside anchor-based repairs. The stiffness values for the 3 repairs were not different. There were no differences in initial displacement. After 100, 300, and 500 cycles, the inside-out repair had higher gap formation (displacement) than the other 2 groups. Suture failure was the predominant mode of failure across all repair techniques. CONCLUSIONS: The all-inside suture-based repairs and inside-out repairs did not exhibit different load-to-failure values. In addition, the all-inside suture-based repairs and the all-inside anchor-based repairs did not exhibit different displacement values during cyclic loading. CLINICAL RELEVANCE: When addressing a longitudinal meniscal tear, surgeons should consider biomechanical data of various repair devices and techniques in their decision-making process to maximize the mechanical strength and healing probability of the repair.


Assuntos
Meniscos Tibiais/cirurgia , Técnicas de Sutura/instrumentação , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Feminino , Meniscos Tibiais/fisiopatologia , Estresse Mecânico , Suínos , Lesões do Menisco Tibial
12.
Knee Surg Sports Traumatol Arthrosc ; 23(5): 1434-41, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24253375

RESUMO

PURPOSE: Proximal biceps tenodesis is one method for treating biceps-related pain. Tenodesis protects the length-tension relationship of the biceps muscle, maintains strength, and provides a better cosmetic appearance than tenotomy. The purpose of this investigation was to compare the mechanical properties of a unicortical metal button and an interference screw in proximal biceps tenodesis. METHODS: Six pairs of fresh-frozen shoulders were dissected, leaving the proximal biceps tendon as a free graft. On each pair of shoulders, a biceps tenodesis was performed using an interference screw or a unicortical metal button. The specimens were mounted and a cyclic load (10-60 N) was applied at 1 Hz for 200 cycles, followed by an axial load to failure. The displacement, ultimate load to failure, and mode of failure were recorded. RESULTS: Displacement in response to cyclic loading was 3.7 ± 2.2 mm for the interference screw and 1.9 ± 1.0 mm for the cortical button (P = 0.03). Load at failure for the interference screw was 191 ± 64 N (stiffness: 24 ± 11 N/mm) and 183 ± 61 N (stiffness: 24 ± 7. N/mm) for the unicortical button (P = n.s. for both cases). CONCLUSIONS: As a novel technique for subpectoral biceps tenodesis, a unicortical button demonstrated significantly less displacement in response to cyclic loading than the interference screw. The ultimate load to failure and stiffness for the two methods were not different. In this way, a unicortical button may provide a reliable alternative method of fixation with a potentially lower risk of post-operative humeral fracture and a construct that permits early mobilization following biceps tenodesis.


Assuntos
Parafusos Ósseos , Bursite/cirurgia , Músculo Esquelético/cirurgia , Procedimentos de Cirurgia Plástica/instrumentação , Âncoras de Sutura , Tendões/cirurgia , Tenodese/métodos , Idoso , Fenômenos Biomecânicos , Bursite/fisiopatologia , Cadáver , Humanos , Músculo Esquelético/fisiopatologia , Tendões/fisiopatologia , Tenotomia/métodos
13.
Arthroscopy ; 31(2): 293-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25312766

RESUMO

PURPOSE: The purpose of this study was to compare gap formation, strength, and stiffness of repaired radial tears of the meniscus treated using a new all-inside technique versus a traditional inside-out suture technique. METHODS: Radial tears were created in 36 fresh-frozen porcine menisci. Repairs were performed using a novel all-inside suture-based meniscal repair device or an inside-out technique. The repairs were tested for cyclic loading and load to failure. The displacement, response to cyclic loading (100, 300, and 500 cycles), and mode of failure were recorded, and the construct's stiffness was calculated. RESULTS: The all-inside repairs using the novel device resulted in a significantly lower displacement (gap formation) after 100, 300, and 500 cycles (P = .002, P = .001, and P = .001, respectively). The ultimate load to failure was significantly greater for the all-inside repairs (111.61 N v 95.01 N; P = .03). The all-inside repairs showed greater stiffness (14.53 N/mm v 11.19 N/mm; P = .02). The all-inside repairs failed most often by suture breakage (suture failure). The inside-out repairs failed most commonly when the suture pulled through the tissue (tissue failure) (P < .001). CONCLUSIONS: For repair of radial tears of the meniscus, the vertical suture configuration created by the all-inside technique resulted in lower displacement, higher load to failure, and greater stiffness compared with the horizontal inside-out technique. CLINICAL RELEVANCE: In a porcine specimen meniscus repair model, the biomechanical properties of a vertical all-inside technique were superior to that of a horizontal inside-out technique. Future studies of biomechanical and clinical outcomes in human meniscal repairs with this device are warranted to explore whether this repair method is valuable to clinical practice and patient outcomes.


Assuntos
Traumatismos do Joelho/cirurgia , Meniscos Tibiais/cirurgia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Traumatismos do Joelho/fisiopatologia , Meniscos Tibiais/fisiopatologia , Técnicas de Sutura , Suínos , Lesões do Menisco Tibial , Cicatrização
14.
Am J Sports Med ; 42(1): 194-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24114752

RESUMO

BACKGROUND: Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. PURPOSE: To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. STUDY DESIGN: Controlled laboratory study. METHODS: Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. RESULTS: The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. CONCLUSION: With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. CLINICAL RELEVANCE: The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.


Assuntos
Meniscos Tibiais/cirurgia , Técnicas de Sutura/instrumentação , Animais , Artroscopia , Fenômenos Biomecânicos , Cadáver , Suínos , Lesões do Menisco Tibial
15.
J Orthop Surg Res ; 8: 24, 2013 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-23883431

RESUMO

BACKGROUND: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy. METHODS: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously. RESULTS: We evaluated this automated system's capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear. DISCUSSION: The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.


Assuntos
Amplitude de Movimento Articular/fisiologia , Robótica/instrumentação , Articulação do Ombro/fisiologia , Fenômenos Biomecânicos/fisiologia , Desenho de Equipamento , Humanos , Fotogrametria/instrumentação , Fotogrametria/métodos , Reprodutibilidade dos Testes , Robótica/métodos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador , Articulação do Ombro/fisiopatologia
16.
J Shoulder Elbow Surg ; 22(7): 986-92, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23313371

RESUMO

HYPOTHESIS: In this study, we aim to test whether scapular winging results in a significant change in glenohumeral translation in the initial phase of the throwing motion. METHODS: Six shoulders underwent an abbreviated throwing motion (ATM) from late cocking to the end of acceleration by use of a validated robotic system. The intact specimens were tested to establish a baseline. The position of the scapula was then affected to simulate scapular winging by placing a cylindrical wedge under the inferior angle of the scapula, and the ATM was performed again. For both conditions, the average glenohumeral translations and scapular rotations were plotted over time to calculate the area under the curve, as a representative of the overall glenohumeral translations and scapular rotations observed during the ATM. RESULTS: Throughout the motion, the winged scapulae showed, on average, 7.7° more upward rotation, 1.6° more internal rotation, and 5.3° more anterior tipping as compared with the baseline. The scapular position relative to the hanging arm was significantly different between the baseline and scapular winging conditions in all arm positions, except for maximal external rotation and the neutral position. Comparing the area under the curve at baseline and with scapular winging indicated that scapular winging significantly increased anterior translation of the glenohumeral joint whereas translation in the superior/inferior and medial/lateral directions did not result in a change in translation. DISCUSSION: These results may suggest a more important role of abnormalities in scapular position in predisposing throwing athletes to shoulder injuries of the anterior capsulolabral structures and consecutive glenohumeral instability.


Assuntos
Instabilidade Articular/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Escápula/anormalidades , Escápula/fisiopatologia , Articulação do Ombro/fisiologia , Esportes , Traumatismos em Atletas/prevenção & controle , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Curva ROC , Rotação
17.
Clin Orthop Relat Res ; 470(7): 1917-24, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22451335

RESUMO

BACKGROUND: Before the US Patient Protection and Affordable Care Act of 2010, there were documented insurance-based disparities in access to orthopaedic surgeons and care of orthopaedic conditions. While Massachusetts passed healthcare reform in 2007 with many similar provisions, it is unknown whether the disparities were present during the period of the law's enactment. QUESTIONS/PURPOSES: We asked whether differences in rates of surgery between patients with novel government-subsidized healthcare plans and other forms of insurance, and between uninsured and insured patients, were similar after institution of the Massachusetts reform laws. METHODS: We identified 7577 patients diagnosed with upper extremity injuries between January 1, 2007 and October 1, 2010. From an institutional administrative database, we extracted demographics, insurance status, and plan of care. Insurance categories included government-subsidized healthcare plan (Commonwealth Care), private insurance, workers compensation, military-related (TriCare), Medicare, Medicaid (MassHealth), non-Commonwealth Care, and other insured and uninsured. After adjusting for age, gender, and diagnosis, we compared the proportions of patients who underwent elective surgery. RESULTS: Of 7577 patients, 1685 (22%) underwent elective upper extremity surgery. The adjusted rates of surgery were similar across most insurance categories, with higher rates in the workers compensation and TriCare categories compared with Commonwealth Care. Uninsured patients were as likely to undergo surgery as insured patients. CONCLUSION: In a population with near-universal health insurance, a government-run health insurance exchange, and novel, government-subsidized, managed care plans, we found few insurance-based differences in rates of elective upper extremity orthopaedic surgery in a cohort of patients after healthcare reform.


Assuntos
Reforma dos Serviços de Saúde/estatística & dados numéricos , Seguro Saúde/estatística & dados numéricos , Pessoas sem Cobertura de Seguro de Saúde/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Patient Protection and Affordable Care Act/estatística & dados numéricos , Extremidade Superior/cirurgia , Adulto , Idoso , Análise de Variância , Boston , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Feminino , Programas Governamentais/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Reforma dos Serviços de Saúde/economia , Reforma dos Serviços de Saúde/legislação & jurisprudência , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Disparidades em Assistência à Saúde/estatística & dados numéricos , Humanos , Seguro Saúde/economia , Seguro Saúde/legislação & jurisprudência , Modelos Logísticos , Masculino , Pessoas sem Cobertura de Seguro de Saúde/legislação & jurisprudência , Medicare/estatística & dados numéricos , Pessoa de Meia-Idade , Razão de Chances , Procedimentos Ortopédicos/economia , Procedimentos Ortopédicos/legislação & jurisprudência , Patient Protection and Affordable Care Act/economia , Patient Protection and Affordable Care Act/legislação & jurisprudência , Setor Privado/estatística & dados numéricos , Estados Unidos , Indenização aos Trabalhadores/estatística & dados numéricos
18.
Arthroscopy ; 26(5): 592-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20434655

RESUMO

PURPOSE: The aim of this study was to assess the contact pressure, force, and area over time for 4 common arthroscopic rotator cuff repair techniques. METHODS: The transosseous-equivalent, single-row, triangle double-row, and suture-chain transosseous repair techniques were used to repair a full-thickness tear of the supraspinatus in 16 cadaveric shoulders. Continuous data points were collected immediately after repair and for 160 minutes at set time intervals by use of a custom thin film pressure sensor. RESULTS: Each of the 4 rotator cuff repair techniques showed decreased contact force, pressure, and area 160 minutes after the repair was performed. The transosseous-equivalent construct had the highest contact pressure and force initially and at all time points up to 160 minutes. Although the 3 double-row constructs had greater pressure and force at all time points compared with the single-row repair, only the transosseous-equivalent group showed a statistically greater pressure and force when compared with single-row repair (P < .05). CONCLUSIONS: Contact pressure, force, and pressurized footprint area decrease 160 minutes after repair regardless of repair technique. The transosseous-equivalent group had the highest contact pressure and force at all time points. CLINICAL RELEVANCE: The decrease in contact pressure and force after rotator cuff repair may have important implications in evaluating tendon-to-bone healing and determining the optimal rehabilitation protocol.


Assuntos
Artroscopia/métodos , Manguito Rotador/cirurgia , Lesões do Ombro , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Manguito Rotador/fisiopatologia , Ruptura , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia , Transferência Tendinosa/métodos , Fatores de Tempo
19.
J Surg Orthop Adv ; 18(3): 115-21, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19843435

RESUMO

Achilles tendon ruptures commonly affect middle-aged athletes and can result in considerable functional impairment. While the cause is multifactorial, the greatest risk is present for athletes involved in sports that involve sudden acceleration and deceleration. A thorough history and physical examination can accurately yield a diagnosis, but when question remains, magnetic resonance imaging is superior to ultrasound-guided evaluation. The best evidence available suggests that operative treatment has a lower rate of rerupture, a higher rate of return to the same level of sport participation, and a higher complication rate, if an open technique is used. Percutaneous methods of fixation have lower complication rates without an increase in the rate of rerupture when compared with open methods. Augmentation of an Achilles tendon repair has demonstrated no clinical benefit. Rehabilitation with early mobilization leads to improved patient-reported outcomes.


Assuntos
Tendão do Calcâneo/lesões , Traumatismos em Atletas/terapia , Procedimentos Ortopédicos/métodos , Tendão do Calcâneo/anatomia & histologia , Tendão do Calcâneo/cirurgia , Adulto , Traumatismos em Atletas/diagnóstico , Traumatismos em Atletas/fisiopatologia , Braquetes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Procedimentos Ortopédicos/reabilitação , Ruptura
20.
J Surg Orthop Adv ; 18(2): 59-68, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19602332

RESUMO

Traumatic glenohumeral instability represents a commonly encountered clinical scenario. Two case vignettes are presented along with an evidence-based review of epidemiology, pathophysiology, diagnosis, and treatment options.


Assuntos
Traumatismos em Atletas/etiologia , Instabilidade Articular/etiologia , Lesões do Ombro , Traumatismos em Atletas/epidemiologia , Traumatismos em Atletas/terapia , Humanos , Incidência , Instabilidade Articular/epidemiologia , Instabilidade Articular/terapia , Procedimentos Ortopédicos/métodos , Prevalência , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA