Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 41(10): 2722-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26215492

RESUMO

The purpose of this study was to assess the potential for ultrasound shear wave elastography (SWE) to measure tissue elasticity and ultimate stress in both intact and healing tendons. The lateral gastrocnemius (Achilles) tendons of 41 New Zealand white rabbits were surgically severed and repaired with growth factor coated sutures. SWE imaging was used to measure shear wave speed (SWS) in both the medial and lateral tendons pre-surgery, and at 2 and 4 wk post-surgery. Rabbits were euthanized at 4 wk, and both medial and lateral tendons underwent mechanical testing to failure. SWS significantly (p < 0.001) decreased an average of 17% between the intact and post-surgical state across all tendons. SWS was significantly (p < 0.001) correlated with both the tendon elastic modulus (r = 0.52) and ultimate stress (r = 0.58). Thus, ultrasound SWE is a potentially promising non-invasive technology for quantitatively assessing the mechanical integrity of pre-operative and post-operative tendons.


Assuntos
Modelos Biológicos , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/fisiopatologia , Tendões/diagnóstico por imagem , Tendões/fisiologia , Ultrassonografia/métodos , Animais , Simulação por Computador , Módulo de Elasticidade , Feminino , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Coelhos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Resistência à Tração , Ondas Ultrassônicas , Cicatrização/fisiologia
2.
Phys Med Biol ; 57(8): 2273-86, 2012 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-22459948

RESUMO

Recent advances in elastography have provided several imaging modalities capable of quantifying the elasticity of tissue, an intrinsic tissue property. This information is useful for determining tumour margins and may also be useful for diagnosing specific tumour types. In this study, we used dynamic compression testing to quantify the viscoelastic properties of 16 human hepatic primary and secondary malignancies and their corresponding background tissue obtained following surgical resection. Two additional backgrounds were also tested. An analysis of the background tissue showed that F4-graded fibrotic liver tissue was significantly stiffer than F0-graded tissue, with a modulus contrast of 4:1. Steatotic liver tissue was slightly stiffer than normal liver tissue, but not significantly so. The tumour-to-background storage modulus contrast of hepatocellular carcinomas, a primary tumour, was approximately 1:1, and the contrast decreased with increasing fibrosis grade of the background tissue. Ramp testing showed that the background stiffness increased faster than the malignant tissue. Conversely, secondary tumours were typically much stiffer than the surrounding background, with a tumour-to-background contrast of 10:1 for colon metastases and 10:1 for cholangiocarcinomas. Ramp testing showed that colon metastases stiffened faster than their corresponding backgrounds. These data have provided insights into the mechanical properties of specific tumour types, which may prove beneficial as the use of quantitative stiffness imaging increases.


Assuntos
Força Compressiva , Elasticidade , Neoplasias Hepáticas/patologia , Fenômenos Biomecânicos , Fígado Gorduroso/complicações , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Estresse Mecânico , Viscosidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-22293748

RESUMO

Thermal ablation procedures are commonly used to treat hepatic cancers and accurate ablation representation on shear wave velocity images is crucial to ensure complete treatment of the malignant target. Electrode vibration elastography is a shear wave imaging technique recently developed to monitor thermal ablation extent during treatment procedures. Previous work has shown good lateral boundary delineation of ablated volumes, but axial delineation was more ambiguous, which may have resulted from the assumption of lateral shear wave propagation. In this work, we assume both lateral and axial wave propagation and compare wave velocity images to those assuming only lateral shear wave propagation in finite element simulations, tissue-mimicking phantoms, and bovine liver tissue. Our results show that assuming bidirectional wave propagation minimizes artifacts above and below ablated volumes, yielding a more accurate representation of the ablated region on shear wave velocity images. Area overestimation was reduced from 13.4% to 3.6% in a stiff-inclusion tissue-mimicking phantom and from 9.1% to 0.8% in a radio-frequency ablation in bovine liver tissue. More accurate ablation representation during ablation procedures increases the likelihood of complete treatment of the malignant target, decreasing tumor recurrence.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Terapia a Laser/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Processamento de Sinais Assistido por Computador , Cirurgia Assistida por Computador/métodos , Animais , Artefatos , Bovinos , Simulação por Computador , Técnicas de Imagem por Elasticidade/instrumentação , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Vibração
4.
IEEE Trans Biomed Eng ; 59(3): 728-35, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22167553

RESUMO

Elastographic imaging can be used to monitor ablation procedures; however, confident and clear determination of the ablation boundary is essential to ensure complete treatment of the pathological target. To investigate the potential for ablation boundary representation on elastographic images, local variations in the viscoelastic properties in radiofrequency-ablated regions that were formed in vivo in porcine liver tissue were quantified using dynamic indentation. Spatial stiffness maps were then correlated to stained histology, the gold standard for the determination of the ablation periphery or boundary. Regions of interest in 11 radiofrequency ablation samples were indented at 18-24 locations each, including the central zone of complete necrosis and more peripheral transition zones including normal tissue. Storage modulus and the rate of stiffening were both greatest in the central ablation zone and decreased with radial distance away from the center. The storage modulus and modulus contrast at the ablation outer transition zone boundary were 3.1 ± 1.0 kPa and 1.6 ± 0.4, respectively, and 36.2 ± 9.1 kPa and 18.3 ± 5.5 at the condensation boundary within the ablation zone. Elastographic imaging modalities were then compared to gross pathology in ex vivo bovine liver tissue. Area estimated from strain, shear-wave velocity, and gross pathology images were 470, 560, and 574 mm(2), respectively, and ablation widths were 19.4, 20.7, and 23.0 mm. This study has provided insights into spatial stiffness distributions within radiofrequency ablations and suggests that low stiffness contrast on the ablation periphery leads to the observed underestimation of ablation extent on elastographic images.


Assuntos
Ablação por Cateter , Técnicas de Imagem por Elasticidade/métodos , Fígado/cirurgia , Algoritmos , Animais , Módulo de Elasticidade , Feminino , Processamento de Imagem Assistida por Computador , Modelos Animais , Necrose , Estresse Mecânico , Suínos
5.
IEEE Trans Med Imaging ; 30(3): 666-78, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21075719

RESUMO

This paper presents a new shear wave velocity imaging technique to monitor radio-frequency and microwave ablation procedures, coined electrode vibration elastography. A piezoelectric actuator attached to an ablation needle is transiently vibrated to generate shear waves that are tracked at high frame rates. The time-to-peak algorithm is used to reconstruct the shear wave velocity and thereby the shear modulus variations. The feasibility of electrode vibration elastography is demonstrated using finite element models and ultrasound simulations, tissue-mimicking phantoms simulating fully (phantom 1) and partially ablated (phantom 2) regions, and an ex vivo bovine liver ablation experiment. In phantom experiments, good boundary delineation was observed. Shear wave velocity estimates were within 7% of mechanical measurements in phantom 1 and within 17% in phantom 2. Good boundary delineation was also demonstrated in the ex vivo experiment. The shear wave velocity estimates inside the ablated region were higher than mechanical testing estimates, but estimates in the untreated tissue were within 20% of mechanical measurements. A comparison of electrode vibration elastography and electrode displacement elastography showed the complementary information that they can provide. Electrode vibration elastography shows promise as an imaging modality that provides ablation boundary delineation and quantitative information during ablation procedures.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatectomia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Bovinos , Técnicas de Imagem por Elasticidade/instrumentação , Eletrodos , Hepatectomia/instrumentação , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Cirurgia Assistida por Computador/instrumentação , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA