Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Arch Cardiovasc Dis ; 110(3): 179-187, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28117244

RESUMO

BACKGROUND: Literature suggests that radial access is associated with higher radiation doses than femoral access. AIMS: To compare patient radiation exposure during coronary angiography (CA) and percutaneous coronary intervention (PCI) with radial versus femoral access. METHODS: RAY'ACT is a nationwide, multicentre, French survey evaluating patient radiation in interventional cardiology. Variables of patient exposure from 21,675 CAs and 17,109 PCIs performed at 44 centres during 2010 were analysed retrospectively. RESULTS: Radial access was used in 71% of CAs and 69% of PCIs. Although median fluoroscopy times were longer for radial versus femoral access (CA, 3.8 vs 3.5minutes [P<0.001]; PCI, 10.4 vs 10.1minutes [P=0.001]), the Kerma-area product (KAP) was lower with radial access (CA, 26.8 vs 28.1Gy·cm2; PCI, 55.6 vs 59.4Gy·cm2; both P=0.001). Differences in KAP remained significant in the multivariable analysis (P<0.01), and in a propensity score-matched analysis (P=0.01). A significant interaction was found between KAP and the percentage of procedures with radial access by centre (P<0.001). KAP was higher by radial versus femoral access in low-radial-volume centres, and lower in high-radial-volume centres. Radiation protection techniques, such as the use of low frame rates (7.5 frame/s), were used more frequently in high-radial-volume radial centres. CONCLUSIONS: In this multicentre study, radial access was associated with lower radiation doses to patient than femoral access in high-radial-volume centres. Provided that radioprotection methods are implemented, radial access could be associated with lower patient radiation exposure.


Assuntos
Cateterismo Periférico/métodos , Angiografia Coronária/métodos , Artéria Femoral , Hospitais com Alto Volume de Atendimentos , Intervenção Coronária Percutânea/métodos , Artéria Radial , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , França , Hospitais com Baixo Volume de Atendimentos , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Pontuação de Propensão , Punções , Artéria Radial/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA