Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
2.
Antibiotics (Basel) ; 12(7)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37508278

RESUMO

In our hospital, adherence to the guidelines for peri-operative antimicrobial prophylaxis (PAP) is suboptimal, with overly long courses being common. This practice does not offer any incremental benefit, and it only adds to the burden of antimicrobial consumption, promotes the emergence of antimicrobial resistance, and it is associated with adverse events. Our objective was to study the effect of an electronic reminder on the adherence to each element of PAP after cardiac surgery. We conducted a single center, before and after intervention, prospective cohort study from 1 June 2014 to 30 September 2017. The intervention consisted of a reminder of the hospital guidelines when ordering PAP through the hospital information system. The primary outcome was adherence to the suggested duration of PAP, while secondary outcomes included adherence to the other elements of PAP and incidence of surgical site infections (SSI). We have studied 1080 operations (400 pre-intervention and 680 post-intervention). Adherence to the appropriate duration of PAP increased significantly after the intervention [PRE 4.0% (16/399) vs. POST 15.4% (105/680), chi-square p < 0.001]; however, it remained inappropriately low. Factors associated with inappropriate duration of PAP were pre-operative hospitalization for <3 days, and duration of operation >4 h, while there were significant differences between the chief surgeons. Unexpectedly, the rate of SSIs increased significantly during the study (PRE 2.8% (11/400) vs. POST 5.9% (40/680), chi-square p < 0.019). The implemented intervention achieved a relative increase in adherence to the guideline-recommended PAP duration; however, adherence was still unacceptably low and further efforts to improve adherence are needed.

3.
Semin Thorac Cardiovasc Surg ; 34(1): 123-132, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33460764

RESUMO

The impairment of intracellular calcium homeostasis plays an essential role during ischemia-reperfusion injury. Calcium release from sarcoplasmic reticulum which is triggered by myocardial ischemia is mainly mediated by ryanodine receptors. Dantrolene sodium is a ryanodine receptor antagonist. The objective of the present study was to evaluate the in-vivo impact of dantrolene sodium on myocardial ischemia-reperfusion injury in swine models. An in vivo, experimental trial comparing 10 experimental animals which received dantrolene sodium with 9 control swine models was conducted. Their left anterior descending coronary artery was temporarily occluded for 75 minutes via a vessel tourniquet, which was then released. Myocardial reperfusion was allowed for 24 hours. Dantrolene was administered at the onset of the reperfusion period and levels of troponin, creatine phosphokinase and creatine kinase myocardial band between the two groups were compared. Additionally, various other hemodynamic parameters and left ventricular morphology and function were examined. There were significantly lower values of troponin, creatine phosphokinase and creatine kinase myocardial band in the dantrolene group indicating less ischemia-reperfusion injury. Moreover, the postischemic cardiac index was also greater in the dantrolene group, whereas viable myocardium was also better preserved. In conclusion, the in vivo cardioprotective role of dantrolene sodium against ischemia-reperfusion injury in swine models was indicated in this study. Therefore, dantrolene sodium administration could be a promising treatment against ischemia-reperfusion injury in humans. However, large randomized clinical studies should be firstly carried out to prove this hypothesis.


Assuntos
Isquemia Miocárdica , Traumatismo por Reperfusão Miocárdica , Animais , Cálcio/metabolismo , Creatina Quinase/metabolismo , Dantroleno/farmacologia , Dantroleno/uso terapêutico , Homeostase , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Miocárdio/metabolismo , Rianodina , Canal de Liberação de Cálcio do Receptor de Rianodina , Suínos , Resultado do Tratamento , Troponina
4.
Indian J Thorac Cardiovasc Surg ; 37(5): 584-587, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34511770

RESUMO

Hybrid arch replacement is a well-accepted method for the treatment of lesions involving the aortic arch, though its benefits compared to classic surgical techniques remain controversial. Multiple surgical approaches have been analyzed in the literature for the treatment of such a challenging pathology. In this case report, we describe the surgical management of a 72-year-old man presenting with a complicated aortic arch rupture. The patient was treated urgently with a type I hybrid arch replacement in two stages, with total preservation of cerebral and systemic perfusion. Our case shows that hybrid arch methods are applicable even in emergency cases.

5.
J Cardiovasc Surg (Torino) ; 62(6): 625-631, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34014059

RESUMO

Aortic valve replacement is the treatment of choice concerning aortic valve disease. Excellent short- and long-term clinical results are reported. Patients referred for aortic valve replacement are getting older and older, so bioprosthetic valves play a more central role worldwide. However, patient comorbidities are also increased more often rendering patients unsuitable for open conventional aortic valve replacement. As a result, transcatheter aortic valve implantation has become the treatment of choice in patients at very high surgical risk. However, the percutaneous technique is related to major disadvantages provided that the diseased native valve is left in place. Its durability is also uncertain. More recently, sutureless Perceval S valve bioprosthesis has gained ground in the field of aortic stenosis therapy filling the gap between conventional aortic valve replacement and transcatheter approach. Excellent hemodynamic and clinical results are reported. Its deployment is performed under direct view and ischemic and overall operative times are significantly decreased. Five-year follow-up results are also optimal. However, the "Achilles' heel" of sutureless technology is increased rates of postoperative permanent pacemaker implantation requirement compared to conventional approach. The incidence of this complication varies in literature. Patient-related factors such as preoperative conduction disorders, older age and short membranous septum are predictors of postoperative pacemaker requirement. However, several technical modifications regarding manufacturer recommendations can be adopted to mitigate this complication. Appropriate annular decalcification, higher guiding sutures placement, reduced balloon pressure and duration and avoiding of oversizing can contribute to prevent from this complication.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Arritmias Cardíacas/prevenção & controle , Bioprótese , Próteses Valvulares Cardíacas , Procedimentos Cirúrgicos sem Sutura , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Hemodinâmica , Humanos , Marca-Passo Artificial , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Ann Card Anaesth ; 24(2): 247-249, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33884987

RESUMO

Coronary artery bypass grafting is the mainstay of revascularization worldwide. However, the most widely used saphenous vein grafts are related to a number of late sequelae. Aortocoronary saphenous vein graft aneurysms mainly diagnosed incidentally are one of these complications. Although rare, given the fatal risk of rupture if left untreated, management either with percutaneous intervention or open redo surgery should be considered. However, no guidelines are established in current scarce literature. Hereby, we present the successful percutaneous management of a huge saphenous vein graft aneurysm via coiling, avoiding the risks of repeat sternotomy.


Assuntos
Aneurisma Aórtico , Veia Safena , Aorta Torácica , Ponte de Artéria Coronária , Erros de Diagnóstico , Humanos , Veia Safena/diagnóstico por imagem
8.
In Vivo ; 34(3 Suppl): 1603-1611, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32503818

RESUMO

The aim of this systematic review was to identify the challenges imposed on medical and surgical education by the COVID-19 pandemic, and the proposed innovations enabling the continuation of medical student and resident training. A systematic review on the MEDLINE and EMBASE databases was performed on April 18th, 2020, and yielded 1288 articles. Sixty-one of the included manuscripts were synthesized in a qualitative description focused on two major axes, "challenges" and "innovative solutions", and two minor axes, "mental health" and "medical students in the frontlines". Shortage of personal protective equipment, suspension of clinical clerkships and observerships and reduction in elective surgical cases unavoidably affect medical and surgical education. Interesting solutions involving the use of virtual learning, videoconferencing, social media and telemedicine could effectively tackle the sudden cease in medical education. Furthermore, trainee's mental health should be safeguarded, and medical students can be involved in the COVID-19 clinical treatment if needed.


Assuntos
Infecções por Coronavirus , Educação Médica/organização & administração , Cirurgia Geral/educação , Medicina Interna/educação , Pandemias , Pneumonia Viral , Estudantes de Medicina/psicologia , COVID-19 , Infecções por Coronavirus/prevenção & controle , Educação a Distância , Avaliação Educacional , Mão de Obra em Saúde/estatística & dados numéricos , Humanos , Internato e Residência , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Equipamentos de Proteção/provisão & distribuição , Treinamento por Simulação , Mídias Sociais , Telemedicina , Realidade Virtual , Carga de Trabalho
9.
J Vasc Surg ; 69(4): 996-1002.e3, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30528410

RESUMO

OBJECTIVE: The aim of the study was to present the results for patients with atherosclerotic aneurysm of the descending thoracic aorta (DTA) treated with a novel thoracic stent graft. METHODS: A single-center retrospective review of prospectively collected data was performed. We extracted demographic variables as well as atherosclerotic comorbidities and operation-related and imaging-related data from patients' medical records. We estimated technical success rate, in-hospital and 30-day mortality, and mortality at the end of follow-up as well as complication and reintervention rate in our study cohort. Follow-up computed tomography angiography was performed after 1 month and 6 months and yearly thereafter. RESULTS: A total of 30 patients (80% male; mean age, 73.7 ± 6.33 years) were treated with Ankura Thoracic Stent Graft (Lifetech, Shenzhen, China) for DTA aneurysm from February 2014 until June 2017. Technical success of the thoracic endovascular aortic repair (TEVAR) was 97% (29/30 patients). A surgical conduit was required in one patient; in three patients, we intentionally covered the left subclavian artery because of insufficient proximal landing zone. No aorta-related deaths were recorded during follow-up. During the early postoperative period, two patients (7%) with long DTA coverage developed paralysis or paraparesis, which immediately resolved after lumbar drainage. No renal complications requiring dialysis were observed. One patient (3%) developed postoperative pulmonary infection, whereas access site complications were 7%. Two symptomatic patients treated outside instructions for use (7%) developed early type IA endoleak and one patient (3%) developed type IB endoleak; type II endoleak was recorded in 3% of the study cohort. During the 30-day postoperative period, two patients died of non-TEVAR-related causes, one of gastrointestinal bleeding and the other of pulmonary infection. During a median follow-up of 31.7 (range, 38.4) months, two more patients also died of non-TEVAR-related causes, one of stroke from carotid artery disease and the other of motor vehicle trauma. In the rest of the cohort, no other adverse events were noted. CONCLUSIONS: This novel endograft showed early evidence of a safe, effective, and durable endoprosthesis for the treatment of DTA aneurysms.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Cardiovasc J Afr ; 29(1): e6-e8, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29582882

RESUMO

Adult cardiac surgery is associated with significant perioperative morbidity and mortality rates, mainly in elderly patients with co-morbidities. A series of postoperative complications may arise and delay the recovery of patients undergoing cardiac surgery. Such complications also increase the burden of resource use and may affect late survival rates. Neurological complications appear mainly as stroke of varying degrees, with impairment of mobility and ability of the patient. We describe a rare case of progressive paraparesis after on-pump coronary artery bypass grafting, and review its aetiology, diagnosis and management.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Síndrome de Guillain-Barré/etiologia , Paraparesia/etiologia , Compressão da Medula Espinal/etiologia , Isquemia do Cordão Espinal/etiologia , Idoso , Edema Encefálico/etiologia , Ponte Cardiopulmonar/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Evolução Fatal , Síndrome de Guillain-Barré/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Paraparesia/diagnóstico por imagem , Posicionamento do Paciente/efeitos adversos , Choque Séptico/etiologia , Compressão da Medula Espinal/diagnóstico por imagem , Isquemia do Cordão Espinal/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
11.
Indian J Surg ; 80(1): 68-76, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29581688

RESUMO

Essential Skills in the Management of Surgical Cases (ESMSC) is an international wet lab simulation course aimed at undergraduate students. It combines basic science workshops, case-based lectures and ex vivo skills modules, as well as in vivo dissections using a swine model. This study aims to evaluate the effectiveness of high-fidelity In Vivo Simulation-Based Learning for undergraduate level trainees. Also our goal was to compare the skill-based performance of final year students vs. more junior-level ones. Forty undergraduate delegates at clinical rotation level (male = 28, female = 12, mean age = 23.12, 22-24, SD = 0.69) attended this 2-day course in Athens. N = 1 (2.5 %) was year 3, N = 4 (10 %) were year 4, N = 23 (57.5 %) were year 5 and N = 12 (30 %) were year 6. N = 30 (75 %) came from Hellenic universities, N = 8 (20 %) from the UK and N = 2 (5 %) from Germany. N = 20 (50 %) attended the in vivo dissections module first, and then the ex vivo one (type A rotation), whereas N = 20 followed the reverse training sequence with the ex vivo dissection first, followed by the in vivo one (type B rotation). The mean global rating scores for type A rotation were better in both the in vivo by 0.10 (2.40 vs. 2.30) and ex vivo modules by 0.15 (2.85 vs. 2.70), though it did not reach statistical significance (p > 0.05). Furthermore, the mean improvement of performance, in the laparoscopic skills station for the type A rotation, was better compared to type B by 0.351 (2.00 vs. 1.65, p = 0.003). Year 6 students performed better in the laparoscopic station (2.00 vs. 1.75, p = 0.059), whereas years 3, 4 and 5 performed better in the in vivo (2.42 vs. 2.16, p = 0.157) as well as the ex vivo dissections (2.78 vs. 2.75, p = 0.832), though none of those comparisons reached statistical significance. Delegates seemed to appreciate and enjoy the in vivo dissections as reflected in the feedback (8.67/10, min = 6 and max = 10, SD = 1.79). Although medical students seem to appreciate in vivo dissections modules, currently, further evidence is needed to support their recommendation in the undergraduate level. Surgical skills should be part of the undergraduate curriculum to improve final year students' performance in the theatre.

13.
Ann Card Anaesth ; 20(Supplement): S70-S72, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28074827

RESUMO

We would like to present in this paper a patient with severe aortic valve stenosis referred to our department for surgical aortic valve replacement. In this patient, it was intraoperatively detected an unexpected heavily calcified porcelain ascending aorta. We present the treatment options in this situation, the difficulties affronted intraoperatively, the significance of the preoperative chest computed tomography scan and the use of the Perceval S aortic valve as ideal bioprosthesis implantation. This is a self-expanding, self-anchoring, and sutureless valve with a wide indication in all patients requiring aortic bioprosthesis.


Assuntos
Aorta/cirurgia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese , Calcinose/diagnóstico por imagem , Ecocardiografia , Humanos , Masculino , Radiografia Torácica
14.
J Invest Surg ; 30(2): 71-77, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27611894

RESUMO

BACKGROUND: Undergraduate Surgical Education is becoming an essential element in the training of the future generation of safe and efficient surgeons. Essential Skills in the Management of Surgical Cases (ESMSC), is an international, joint applied surgical science and simulation-based learning wet lab course. METHODS: We performed a review of the existing literature on the topic of undergraduate surgical education. Following that, we analyzed the feedback questionnaire received 480 from 2 recent series of ESMSC courses (May 2015, n = 49 and November 2015, n = 40), in order to evaluate European Union students' (UK, Germany, Greece) views on the ESMSC course, as well as on the undergraduate surgical education. Results Using a 10 point graded scale, the overall ESMSC concept was positively evaluated, with a mean score of 9.41 ± 0.72 (range: 8-10) and 8.94 ± 1.1 (range: 7-10). The majority of delegates from both series [9.86 ± 0.43 (range: 8-10) and 9.58 ± 0.91 (range: 6-10), respectively] believed that ESMSC should be incorporated in the undergraduate surgical curriculum. Comparison of responses from the UK to the Greek Medical Student, as well as the findings from the third and fourth year versus the fifth and sixth year Medical Students, revealed no statistically significant differences pertaining to any of the questions (p > 0.05). CONCLUSIONS: Current evidence in the literature supports the enhancement of surgical education through the systematic use of various modalities that provide Simulation-Based Training (SBT) hands-on experience, starting from the early undergraduate level. The findings of the present study are in agreement with these previous reports.


Assuntos
Currículo , Educação de Graduação em Medicina/métodos , Cirurgia Geral/educação , Treinamento por Simulação , Adulto , Feminino , Alemanha , Grécia , Humanos , Masculino , Inquéritos e Questionários , Reino Unido , Adulto Jovem
15.
J Cardiol ; 69(1): 46-56, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27727088

RESUMO

A hybrid strategy, firstly performed in the 1990s, is a combination of tools available only in the catheterization laboratory with those available only in the operating room in order to minimize surgical morbidity and face with any cardiovascular lesion. The continuous evolution of stent technology along with the adoption of minimally invasive surgical approaches, make hybrid approaches an attractive alternative to standard surgical or transcatheter techniques for any given set of cardiovascular lesions. Examples include hybrid coronary revascularization, when an open surgical anastomosis of the left internal mammary artery to the left anterior descending coronary artery is performed along with stent implantation in non-left anterior descending coronary vessels, open heart valve surgery combined with percutaneous coronary interventions to coronary lesions, hybrid aortic arch debranching combined with endovascular grafting for thoracic aortic aneurysms, hybrid endocardial and epicardial atrial fibrillation procedures, and carotid artery stenting along with coronary artery bypass grafting. The cornerstone of success for all of these methods is the productive collaboration between cardiac surgeons and interventional cardiologists. The indications and patient selection of these procedures are still to be defined. However, high-risk patients have already been shown to benefit from hybrid approaches.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Doenças Cardiovasculares/cirurgia , Terapia Combinada/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Stents
16.
J Surg Res ; 207: 164-173, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27979473

RESUMO

BACKGROUND: The adverse effects of myocardial ischemia and reperfusion during cardiopulmonary bypass (CPB) have been thoroughly described. Lazaroid U-74389G, a 21 aminosteroid, has been shown to attenuate ischemia and reperfusion injury and improve recovery in a variety of experimental models. METHODS: Sixteen male swine were randomly divided in two groups. All animals underwent 45 min of ischemic cardioplegic arrest, with U-74389G addition to the standard cardioplegic solution, whereas controls underwent the same procedure without U-74389G. Creatine kinase-MB isoenzyme (CK-MB) and cardiac troponin T levels were measured immediately before CPB (time point 0), during the ischemic period (time point 1) and 30 (time point 2), 60 (time point 3), and 120 (time point 4) min after reperfusion. Myocardial biopsies were obtained at time points 0 and 4. RESULTS: CK-MB levels (in U/L) at time points 0-4 were 205 (186-235) versus 219 (196-269; P = 0.72), 215 (167-248) versus 253 (193-339; P = 0.23), 234 (198-255) versus 338 (249-441; P = 0.02), 244 (217-272) versus 354 (269-496; P = 0.01), and 285 (230-321) versus 439 (432-530; P < 0.01) in lazaroid-treated animals versus controls, respectively. Cardiac troponin T levels (in ng/L) at time points 0-4 were 58 (26-287) versus 237 (26-395; P = 0.72), 129 (61-405) versus 265 (145-525; P = 0.23), 261 (123-467) versus 474 (427-1604; P = 0.04), 417 (204-750) versus 841 (584-1818; P = 0.11), and 643 (353-1259) versus 1600 (1378-2313; P < 0.01), respectively. Necrosis grades at time point 4 were 0.0 (0.0-1.0) versus 1.5 (1.0-2.0; P < 0.01) in lazaroid-treated animals versus controls, respectively. CONCLUSIONS: The present study, in addition to reconfirming the well-described adverse effects of CPB, demonstrates the efficacy of the newer generation lazaroid U-74389G in alleviating these effects.


Assuntos
Cardiotônicos/uso terapêutico , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Pregnatrienos/uso terapêutico , Animais , Biomarcadores/metabolismo , Biópsia , Masculino , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Miocárdio/metabolismo , Miocárdio/patologia , Necrose , Distribuição Aleatória , Suínos , Resultado do Tratamento
18.
Ann Card Anaesth ; 19(2): 363-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27052087

RESUMO

We would like to describe a case with a complex aortic disease treated in hybrid fashion. We present an interesting case of a 65-year-old man with a medical history of hypertension, hyperlipidemia, and coronary artery disease percutaneously treated. An acute Type B aortic dissection occurred and treated with the implantation of a stent-graft which occluded the left subclavian artery due to its extension to the aortic arch. This event required a carotid-subclavian artery bypass due to ischemia of the left arm. An aneurysm in the innominate artery also detected, was treated with another stent-graft implantation 3 months later. At 5-year follow-up, an aneurysm of the thyreocervical trunk was found while the stent-graft of the aorta was well-tolerated without endoleak and the carotid-subclavian graft was patent. The aneurysm was asymptomatic but considering the risk of spontaneous rupture of an aneurysm of this size, elective surgery was indicated. Because the aneurysm was very close to the brachiocephalic bifurcation, open surgical repair would require a sternotomy. The right common carotid artery and right subclavian artery were exposed. The thyrocervical trunk, right internal mammary artery and right vertebral artery were occluded by ligations to isolate the aneurysm. An 8-mm Dacron graft was anastomosed end-to-end to the distal part of subclavian artery. We would like through this case, discuss the role of the hybrid cardiovascular surgery to minimize the postoperative complications in complex cardiovascular pathology. We also discuss the international bibliography about the thyreocervical trunk aneurysm and the treatment options.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Idoso , Anastomose Cirúrgica , Aneurisma/patologia , Aneurisma/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular , Artérias Carótidas/cirurgia , Circulação Cerebrovascular , Humanos , Masculino , Stents , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/patologia , Artéria Subclávia/cirurgia , Tomografia Computadorizada por Raios X , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/patologia , Artéria Vertebral/cirurgia
19.
J Cardiothorac Surg ; 11(1): 54, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27066903

RESUMO

BACKGROUND: The aim of this study is to see how the sutureless, stentless, Perceval S aortic valves behave when implanted in elderly patients with small aortic root and the comparison with a second group of patients with similar characteristics where a conventional stented bioprosthesis was implanted. This is a prospective randomized institutional study. METHODS: Our material is composed from 25 patients who underwent aortic valve replacement with sutureless self-anchoring Perceval S valve implantation (LivaNova), compared with 25 patients with conventional stented biological prosthesis implanted (soprano LivaNova group). The two groups of patients have similar demographic and medical characteristics with severe aortic stenosis. The study was conducted from January 2012 to June 2014. Preoperative, intraoperative and postoperative parameters were studied in order to investigate the utility of the Perceval S valves in this group of patients. RESULTS: The Perceval S valve implantation seems to be an interesting biological valve with good hemodynamic characteristics as compared with the typical biological prosthesis providing shorter ischemia time (40 ± 5.50 min vs 86 ± 15.86 min; p < 0.001), shorter extracorporeal circulation time (73.75 ± 8.12 min vs 120.36 ± 28.31 min p < 0.001), less operation time (149.38 ± 15.22 min vs 206.64 ± 42.85 min; p < 0.001) and better postoperative recovery. The postoperative gradients were 23.5 ± 19.20 mmHg vs 24.5 ± 19.90 mmHg respectively. The postoperative effective orifice area in these two groups were respectively 1.5 =/-0.19 cm(2) vs 1.1=/-0.5 cm(2) (p 0.002). Among the 25 patients of the Soprano stented valve, 3 (12 %) came back in 6 months with New York Heart Association (NYHA) 3. The PPM of these patients was the cause of readmission in the Hospital required diuresis and supplementary treatment. CONCLUSIONS: Aortic valve replacement with Perceval aortic valves in geriatric patients with comorbidities and small aortic annulus seems to be an alternative, safe and "fast" intervention with excellent short and mid-term results which provides a better effective orifice area.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Bioprótese , Superfície Corporal , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Desenho de Prótese , Stents , Procedimentos Cirúrgicos sem Sutura/instrumentação , Procedimentos Cirúrgicos sem Sutura/métodos
20.
Ann Card Anaesth ; 19(1): 162-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26750694

RESUMO

We would like to present an interesting case operated on in our department and discuss the international bibliography about this issue. We also present some interesting images of this case. Our material is composed from a 68-year-old woman treated by the authors. She presented with a small murmur in the auscultation while she was asymptomatic and then she diagnosed with a tumor on of the left coronary cusp of the aortic valve with the characteristics of papillary fibroelastoma. On the basis of the potential embolic risk either of the mass itself or of associated thrombus and the possibility of further enlargement, the patient although asymptomatic at the time of diagnosis was referred for elective surgical excision of the mass. She underwent on median sternotomy and through extracorporeal circulation the mass has been excised with the preservation of the well-functioning valve. Through this case, we would like to discuss the bibliography for the decision making in these cases. Hence, the aim of our study is that we have to keep in mind that this kind of friable mass may be the cause of embolism, stroke or coronary artery occlusion and must be excided in a conservative setting, sparing the aortic valve.


Assuntos
Neoplasias Cardíacas/patologia , Idoso , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/cirurgia , Humanos , Infarto do Miocárdio/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA