Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diabetes Obes Metab ; 25(12): 3709-3715, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37681278

RESUMO

AIM: To provide a preliminary evaluation of the accuracy and safety of Gluclas decision support system suggestions in a hypoglycaemic clamp study. METHODS: This analysis was performed using data from 32 participants (four groups with different glucose-insulin regulation: post Roux-en-Y gastric bypass with and without postprandial hypoglycaemia syndrome, postsleeve gastrectomy and non-operated controls) undergoing Gluclas-assisted hypoglycaemic clamps (target: 2.5 mmol/L for 20 minutes at 150 minutes after oral glucose ingestion). Gluclas provided glucose infusion rate suggestions upon manual entry of blood glucose values (every 5 minutes), which were either followed or overruled by investigators after critical review. Accuracy and safety were evaluated by mean absolute error (MAE), mean absolute percentage error (MAPE), average glucose level, coefficient of variation (CV) and minimal glucose level during the 20-minute hypoglycaemic period. RESULTS: Investigators accepted 84% of suggestions, with a mean deviation of 30.33 mg/min. During the hypoglycaemic period, the MAE was 0.16 (0.12-0.24) (median [interquartile range]) mmol/L and the MAPE was 6.12% (4.80%-9.29%). CV was 4.90% (3.58%-7.27%), with 5% considered the threshold for sufficient quality. The minimal glucose level was 2.40 (2.30-2.50) mmol/L. CONCLUSIONS: Gluclas achieved sufficiently high accuracy with minimal safety risks in a population with differences in glucose-insulin dynamics, underscoring its applicability to various patient groups.


Assuntos
Hipoglicemia , Insulinas , Humanos , Glicemia , Glucose , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina
2.
Diabetologia ; 66(4): 741-753, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36648553

RESUMO

AIMS/HYPOTHESIS: Post-bariatric hypoglycaemia is an increasingly recognised complication of bariatric surgery, manifesting particularly after Roux-en-Y gastric bypass. While hyperinsulinaemia is an established pathophysiological feature, the role of counter-regulation remains unclear. We aimed to assess counter-regulatory hormones and glucose fluxes during insulin-induced postprandial hypoglycaemia in patients with post-bariatric hypoglycaemia after Roux-en-Y gastric bypass vs surgical and non-surgical control individuals. METHODS: In this case-control study, 32 adults belonging to four groups with comparable age, sex and BMI (patients with post-bariatric hypoglycaemia, Roux-en-Y gastric bypass, sleeve gastrectomy and non-surgical control individuals) underwent a postprandial hypoglycaemic clamp in our clinical research unit to reach the glycaemic target of 2.5 mmol/l 150-170 min after ingesting 15 g of glucose. Glucose fluxes were assessed during the postprandial and hypoglycaemic period using a dual-tracer approach. The primary outcome was the incremental AUC of glucagon during hypoglycaemia. Catecholamines, cortisol, growth hormone, pancreatic polypeptide and endogenous glucose production were also analysed during hypoglycaemia. RESULTS: The rate of glucose appearance after oral administration, as well as the rates of total glucose appearance and glucose disappearance, were higher in both Roux-en-Y gastric bypass groups vs the non-surgical control group in the early postprandial period (all p<0.05). During hypoglycaemia, glucagon exposure was significantly lower in all surgical groups vs the non-surgical control group (all p<0.01). Pancreatic polypeptide levels were significantly lower in patients with post-bariatric hypoglycaemia vs the non-surgical control group (median [IQR]: 24.7 [10.9, 38.7] pmol/l vs 238.7 [186.3, 288.9] pmol/l) (p=0.005). Other hormonal responses to hypoglycaemia and endogenous glucose production did not significantly differ between the groups. CONCLUSIONS/INTERPRETATION: The glucagon response to insulin-induced postprandial hypoglycaemia is lower in post-bariatric surgery individuals compared with non-surgical control individuals, irrespective of the surgical modality. No significant differences were found between patients with post-bariatric hypoglycaemia and surgical control individuals, suggesting that impaired counter-regulation is not a root cause of post-bariatric hypoglycaemia. TRIAL REGISTRATION: ClinicalTrials.gov NCT04334161.


Assuntos
Derivação Gástrica , Hipoglicemia , Obesidade Mórbida , Adulto , Humanos , Glucagon , Polipeptídeo Pancreático , Estudos de Casos e Controles , Hipoglicemia/complicações , Glucose , Insulina , Hipoglicemiantes , Glicemia , Gastrectomia/efeitos adversos , Obesidade Mórbida/cirurgia
3.
Pacing Clin Electrophysiol ; 43(12): 1554-1563, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33111985

RESUMO

BACKGROUND: Catheter-delivered radiofrequency (RF) lesion formation is a complex phenomenon, and few studies have explored the effect of catheter orientation on lesion size and catheter orientation behavior during pulmonary vein isolation (PVI) procedures. We evaluated the influence of catheter orientation on lesion dimensions in an in vitro experimental setting and investigated the catheter orientation behavior during PVI. METHODS AND RESULTS: 72 lesions were created in vitro on a porcine heart using a contact force catheter in a parallel, oblique, and perpendicular tip to tissue orientation. The superficial lesion length (SLL) increased shifting the catheter from perpendicular to parallel orientation. The intratissue absolute maximal lesion length (AML) was greater with an oblique catheter orientation. The lesion depth (LD) and the superficial lesion width (SLW) resulted similar with any orientation. Data from 21 PVI procedures in patients with paroxysmal atrial fibrillation using the "wide antral circumferential RF ablation" (WACA) technique were retrospectively analyzed. The mean contact angle among 1130 RF lesions was 28 ± 20°. A prevalent parallel orientation was noted in the anterior WACA segments, whereas it resulted more perpendicular in the posterior segments. Significant differences in catheter orientation between the three operators were found only in few WACA segments. CONCLUSIONS: In an in vitro setting, catheter orientation affects SLL and AML, but not LD and SLW. During PVI procedures, catheter orientation resulted mostly parallel to the endocardium. Catheter orientation varied among different WACA segments, but only small differences were found between three operators when considering similar WACA segments.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Animais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA