Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37103590

RESUMO

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/métodos , Estudos de Viabilidade , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Catéteres
2.
Neurol Sci ; 44(3): 979-988, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36383264

RESUMO

BACKGROUND: Subclinical atrial fibrillation (SCAF) may represent a cause of embolic stroke of undetermined source (ESUS) and its detection has important implications for secondary prevention with anticoagulation. Indications to implantable cardiac monitors (ICM) include SCAF detection. The aims of this study were to (1) evaluate the frequency of ICM-detected SCAF; (2) determine predictors of SCAF; and (3) identify patients who would benefit most from ICM implantation. METHODS: Between February 2017 and November 2020, all consecutive patients referred for ICM implantation after a diagnosis of ESUS and without previous history of atrial fibrillation or atrial flutter were included in this study. SCAF was diagnosed if the ICM electrogram demonstrated an episode of irregularly irregular rhythm without distinct P waves lasting > 2 min. RESULTS: We enrolled 109 patients (age 66, SD = 13 years; 36% females). During a median follow-up of 19.2 (IQR 11.0-27.5) months, SCAF episodes were detected in 36 (33%) patients. Only abnormal P wave terminal force in lead V1, left atrial end-systolic indexed volume > 34 ml/m2, and BMI > 25 kg/m2 were independently associated with an increased risk of SCAF (HR 2.44, 95% CI 1.14-5.21, p = 0.021; HR 2.39, 95% CI 1.11-5.13, p = 0.026; and HR 2.64, 95% CI 1.06-6.49, p = 0.036 respectively). The ROC curve showed that the presence of all three parameters had the best accuracy (74%) to predict SCAF detection (sensitivity 39%, specificity 91%). CONCLUSION: A multiparametric evaluation has the best accuracy to predict SCAF in ESUS patients and may help identifying those who would benefit most from ICM.


Assuntos
Fibrilação Atrial , AVC Embólico , Acidente Vascular Cerebral , Feminino , Humanos , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , AVC Embólico/complicações , Fatores de Risco , Eletrocardiografia/efeitos adversos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico
3.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
4.
Am J Cardiol ; 181: 45-54, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35973836

RESUMO

Management of ventricular arrhythmias (VAs) beyond implantable cardioverter-defibrillator positioning in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) is challenging. Catheter ablation of the ventricular substrate often requires a combination of endocardial and epicardial approaches, with disappointing outcomes due to the progressive nature of the disease. We report the Universitair Ziekenhuis Brussel experience through a case series of 16 patients with drug-refractory ARVC, who have undergone endocardial and/or epicardial catheter ablation of VAs with a thoracoscopic hybrid-approach. After a mean follow-up time of 5.16 years (SD 2.9 years) from the first hybrid-approach ablation, VA recurrence was observed in 5 patients (31.25%): among these, patients 4 patients (80%) received a previous ablation and 1 of 11 patients (9.09%) who had a hybrid ablation as first approach had a VA recurrence (80% vs 9.09%; log-rank p = 0.04). Despite the recurrence rate of arrhythmic events, all patients had a significant reduction in the arrhythmic burden after ablation, with a mean of 4.65 years (SD 2.9 years) of freedom from clinically significant arrhythmias, defined as symptomatic VAs or implantable cardioverter-defibrillator-delivered therapies. In conclusion, our case series confirms that management of VAs in patients with ARVC is difficult because patients do not always respond to antiarrhythmic medications and can require multiple invasive procedures. A multidisciplinary approach involving cardiologists, cardiac surgeons, and cardiac electrophysiologists, together with recent cardiac mapping techniques and ablation tools, might mitigate these difficulties and improve outcomes.


Assuntos
Displasia Arritmogênica Ventricular Direita , Ablação por Cateter , Taquicardia Ventricular , Displasia Arritmogênica Ventricular Direita/cirurgia , Ablação por Cateter/métodos , Humanos , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
5.
J Am Heart Assoc ; 11(15): e026290, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35862178

RESUMO

Background Pharmacological treatment of atrial fibrillation (AF) in the setting of Brugada syndrome (BrS) is challenging. In addition, patients with BrS with an implantable cardioverter-defibrillator (ICD) might experience inappropriate shocks for fast AF. Long-term outcome of pulmonary vein isolation in BrS has not been well established yet, and it is still unclear whether pulmonary vein triggers are the only pathophysiological mechanism of AF in BrS. The aim of the study is to assess the long-term outcomes in patients with BrS undergoing pulmonary vein isolation for paroxysmal AF compared with a matched cohort of patients without BrS. Methods and Results Sixty patients with BrS undergoing pulmonary vein isolation with cryoballoon catheter ablation for paroxysmal AF were matched with 60 patients without BrS, who underwent the same procedure. After a mean follow-up of 58.2±31.7 months, freedom from atrial tachyarrhythmias was achieved in 61.7% in the BrS group and in 78.3% in the non-BrS group (log-rank P=0.047). In particular, freedom from AF was 76.7% in the first group and in 83.3% in the second (P=0.27), while freedom from atrial tachycardia/atrial flutter was 85% and 95% (P=0.057). In the BrS group, 29 patients (48.3%) had an ICD and 8 (27.6%) had a previous ICD-inappropriate shock for fast AF. In the BrS cohort, ICD-inappropriate interventions for AF were significantly reduced after ablation (3.4% versus 27.6%; P=0.01). Conclusions Pulmonary vein isolation in patients with BrS was associated with higher rate of arrhythmic recurrence. Despite this, catheter ablation significantly reduced inappropriate ICD interventions in BrS patients and can be considered a therapeutic strategy to prevent inappropriate device therapies.


Assuntos
Fibrilação Atrial , Flutter Atrial , Síndrome de Brugada , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Síndrome de Brugada/complicações , Síndrome de Brugada/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA