Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Heart Rhythm ; 11(10): 1721-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25016148

RESUMO

BACKGROUND: Both type 1 myotonic dystrophy (MD1) and Brugada syndrome (BrS) may be complicated by conduction disturbances and sudden death. Spontaneous BrS has been observed in MD1 patients, but the prevalence of drug-induced BrS in MD1 is unknown. OBJECTIVE: The purpose of this study was to prospectively assess the prevalence of type 1 ST elevation as elicited during pharmacologic challenge with Class 1C drugs in a subgroup of MD1 patients and to further establish correlations with ECG and electrophysiologic variables and prognosis. METHODS: From a group of unselected 270 MD1 patients, ajmaline or flecainide drug challenge was performed in a subgroup of 44 patients (27 men, median age 43 years) with minor depolarization/repolarization abnormalities suggestive of possible BrS. The presence of type 1 ST elevation after drug challenge was correlated to clinical, ECG, and electrophysiologic variables. RESULTS: Eight of 44 patients (18%) presented with BrS after drug challenge. BrS was seen more often in men (26% vs 6%, P = .09) and was related to younger age (35 vs 48 years, P = .07). BrS was not correlated to symptoms, baseline ECG, HV interval, results of signal-averaged ECG, or abnormalities on ambulatory recordings. MD1 patients with BrS had longer corrected QT intervals, greater increase in PR interval after drug challenge, and higher rate of inducible ventricular arrhythmias (62% vs 21%, P = .03). Twelve patients were implanted with a pacemaker and 5 with an implantable cardioverter-defibrillator. Significant bradycardia did not occur in any patients, and malignant ventricular arrhythmia never occurred during median 7-year follow-up (except 1 hypokalemia-related ventricular fibrillation). CONCLUSION: BrS is elicited by a Class 1 drug in 18% of MD1 patients presenting with minor depolarization/repolarization abnormalities at baseline, but the finding seems to be devoid of a prognostic role.


Assuntos
Ajmalina/efeitos adversos , Síndrome de Brugada/induzido quimicamente , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia/efeitos dos fármacos , Flecainida/efeitos adversos , Distrofia Miotônica/tratamento farmacológico , Adulto , Ajmalina/uso terapêutico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Feminino , Flecainida/uso terapêutico , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Distrofia Miotônica/complicações , Distrofia Miotônica/fisiopatologia , Prevalência , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Bloqueadores do Canal de Sódio Disparado por Voltagem
2.
Eur Heart J ; 35(22): 1479-85, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24536081

RESUMO

AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/mortalidade , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Volume Sistólico/fisiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Adulto Jovem
3.
Pacing Clin Electrophysiol ; 35(12): 1413-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22897428

RESUMO

BACKGROUND: T-wave alternans (TWA) is an accepted marker of risk for malignant ventricular arrhythmias, for which prognosis value has been established in different populations. Short QT syndrome (SQTS) is a very rare primary electrical disease carrying the risk of ventricular fibrillation. TWA in SQTS has not been evaluated yet. METHODS: Thirteen patients with SQTS (QT = 308 ± 16 ms, QTc = 329 ± 10 ms, heart rate = 69 ± 8 beats/min) underwent microvolt TWA measurement using spectral analysis. TWA testing was performed using Heartwave II (Cambridge Heart™, Inc., Bedford, MA, USA) during bicycle exercice and classified as negative, positive, or indeterminate according to the published standards for clinical interpretation. RESULTS: Twelve patients were male (mean age 23 ± 5 years). Five were asymptomatic, three presented with aborted sudden cardiac death, and five with unexplained syncope. Six patients belonged to two unrelated families, while familial cases of SQTS were present for two other patients. A familial history of sudden death (SD) was present for seven patients. Ventricular fibrillation was inducible in three patients. Four patients were implanted with an implantable cardioverter-defibrillator and one presented with polymorphic ventricular tachycardia during follow-up. TWA was negative in each but one patient (indeterminate). Maximal negative heart rate was 118 ± 12 beats/min. Patients with previous SD displayed significant shorter QT and higher resting heart rate compared to the remaining cases. CONCLUSIONS: TWA testing is negative in 12 of 13 SQTS patients, even in the symptomatic or inducible ones. Measurement of TWA using conventional protocol and criteria for risk stratification in SQTS seems therefore useless.


Assuntos
Arritmias Cardíacas/fisiopatologia , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Arritmias Cardíacas/genética , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Estatísticas não Paramétricas , Síncope/genética , Síncope/fisiopatologia , Síndrome , Fibrilação Ventricular/genética , Fibrilação Ventricular/fisiopatologia
4.
Am J Cardiol ; 110(9): 1302-8, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22819431

RESUMO

Early repolarization pattern (ERP) has recently been associated with idiopathic ventricular fibrillation and with cardiovascular mortality in the general population. We aimed to identify electrocardiographic tools to differentiate the "malignant" form of ERP from benign ERP in a population-based study. We retrospectively assessed the prevalence of ERP by recording electrocardiograms in 1,161 southwestern French subjects 35 to 64 years old. ERP was defined by an elevation of the J point ≥1 mm in 2 consecutive leads excluding leads V(1) through V(3). We categorized ERP as notching or slurring pattern as located in inferior and/or lateral leads and measured the J-point elevation amplitude. ST segment after ERP was categorized as ascendant or horizontal/nonascendant and T waves as negative or positive. Association of ERP with all-cause and cardiovascular mortalities was assessed by adjusted Cox proportional hazard models. ERP was found in 157 subjects (13.3%). During a mean follow-up of 14.2 ± 2 years, 77 subjects died (6.6%), of whom 24 (2.1%) died from cardiovascular causes. Subjects with ERP had an increased hazard ratios for all-cause mortality (2.45, 95% confidence interval [CI] 1.44 to 4.15, p = 0.001) and cardiovascular mortality (5.60, 95% CI 2.27 to 11.8, p = 0.001). The highest risk was found for notching ERP and ERP with a nonascendant/horizontal ST segment, yielding when associated increased hazard ratios of 3.84 (95% CI 2.14 to 6.92, p = 0.001) and 8.75 (95% CI 3.48 to 22.0, p = 0.001) for all-cause and cardiovascular mortalities, respectively. Conversely, a slurring ERP or ascendant ST segment was not associated with increased mortality. ERP localization, J-point elevation amplitude, or T-wave morphology did not distinguish benign from malignant forms of ERP. In conclusion, ERP with notching pattern and horizontal/descendant ST segments was associated with the highest risk of all-cause and cardiovascular deaths. These electrocardiographic patterns may be used for risk stratification in subjects with ERP.


Assuntos
Causas de Morte , Morte Súbita Cardíaca/patologia , Eletrocardiografia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Estudos de Casos e Controles , Intervalos de Confiança , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prevalência , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo , Fibrilação Ventricular/fisiopatologia
5.
Arch Cardiovasc Dis ; 104(5): 325-31, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21693369

RESUMO

BACKGROUND: A programme for quality assurance and prevention of infection risk during implantation of cardiac medical devices (pacemakers and defibrillators) was set up in our hospital. AIM: We sought to assess surgical site infection rate and compliance with infection-control practices (principally antibiotic prophylaxis). METHODS: Surgical site infections associated with implanted medical devices were monitored in patients during a 6-month period and a 1-year follow-up. Professional practices concerning the use of prophylactic antibiotics in surgery were assessed. RESULTS: The surgical site infection rate was 2.3%. Overall compliance was 45% for the use of antibiotic prophylaxis. CONCLUSIONS: Optimal compliance with antibiotic prophylaxis was not reached in the present series, which demonstrated a surgical site infection rate of 2.3%. More effort must be made to achieve full compliance with preventive measures in the implantation of medical devices.


Assuntos
Antibioticoprofilaxia/normas , Infecção Hospitalar/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Controle de Infecções/normas , Marca-Passo Artificial/efeitos adversos , Prática Profissional/normas , Infecções Relacionadas à Prótese/prevenção & controle , Garantia da Qualidade dos Cuidados de Saúde/normas , Infecção da Ferida Cirúrgica/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos Locais/uso terapêutico , Competência Clínica/normas , Infecção Hospitalar/etiologia , Feminino , França , Fidelidade a Diretrizes , Desinfecção das Mãos/normas , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Medição de Risco , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento
6.
Arch Cardiovasc Dis ; 103(11-12): 585-94, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21147443

RESUMO

BACKGROUND: Differences in the duration of the excitable gap along the reentry circuit during typical atrial flutter are poorly known. AIM: To prospectively evaluate and compare the duration and composition of the excitable gap during typical counterclockwise atrial flutter in different parts of the circuit all around the tricuspid annulus. METHODS: The excitable gap was determined by introducing a premature stimulus at various sites around the tricuspid annulus during typical counterclockwise atrial flutter in 34 patients. Excitable gap was calculated as the difference between the longest resetting coupling interval and the effective atrial refractory period. RESULTS: The duration of the excitable gap, the effective atrial refractory period and the resetting coupling interval differed significantly along the tricuspid annulus. Duration of excitable gap was significantly longer at the low lateral right atrium (79±22 ms) than at the cavotricuspid isthmus (66±23 ms; P=0.002). The effective atrial refractory period was significantly longer at the cavotricuspid isthmus (160±26 ms) than at the high lateral right atrium (149±29 ms; P=0.004). Other locations, such as coronary sinus ostium, right atrial septum and atrial roof displayed intermediate values. CONCLUSION: The duration of the excitable gap differed significantly along the tricuspid annulus, with a larger excitable gap at the lateral right atrium and a shorter excitable gap at the cavotricuspid isthmus, because of longer refractory periods at the isthmus.


Assuntos
Flutter Atrial/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Valva Tricúspide/fisiopatologia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Período Refratário Eletrofisiológico , Reoperação , Fatores de Tempo , Resultado do Tratamento
7.
J Interv Card Electrophysiol ; 29(1): 63-7, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20393793

RESUMO

We report the first case of percutaneous radio-frequency (RF) ablation procedure in a patient implanted with a HeartMate II left ventricular assist device for refractory heart failure. This procedure was performed for poorly tolerated recurrent atrial arrhythmias. No harmful consequence happened during or after the procedure despite the potential electromagnetic interferences existing between the RF delivery and the functioning of the device.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Flutter Atrial/complicações , Flutter Atrial/diagnóstico , Eletrocardiografia , Seguimentos , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
8.
Cardiology ; 110(1): 17-28, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17934265

RESUMO

OBJECTIVES: Complete bidirectional cavo-tricuspid isthmus (CTI) block is mandatory for radio-frequency (RF) ablation of typical atrial flutter (AF). CTI block can be assessed by a simplified method using two catheters and the technique of differential pacing, but long-term results in large series are poorly known. METHODS: CTI RF ablation was performed in 255 consecutive patients with typical AF, using one quadripolar catheter, and the ablation catheter, in association with the technique of differential pacing. RESULTS: Procedural success, as defined by documentation of complete bidirectional CTI block using limited activation mapping, positive differential pacing together with termination of ongoing AF, was achieved in 80% of patients. AF recurred in 37 patients (14%) over a mean follow-up period of 15 +/- 9 months. Two hundred and forty-one patients (94%) were finally cured, with 1.1 procedures/patient. The recurrence rate was related to the achievement of complete CTI bidirectional block (12% vs. 29%, p = 0.01). CONCLUSIONS: Long-term results of CTI ablation, employing a simplified method using the differential pacing technique, are similar to those for the standard methods using multipolar catheters. Therefore, this technique compares favorably to other established methods for such common RF procedures, especially due to its lower cost.


Assuntos
Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Bloqueio Cardíaco/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/mortalidade , Feminino , Seguimentos , Sistema de Condução Cardíaco , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Probabilidade , Estudos Prospectivos , Recidiva , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide
10.
Circulation ; 108(8): 925-8, 2003 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-12925452

RESUMO

BACKGROUND: The long-QT and Brugada syndromes are important substrates of malignant ventricular arrhythmia. The feasibility of mapping and ablation of ventricular arrhythmias in these conditions has not been reported. METHODS AND RESULTS: Seven patients (4 men; age, 38+/-7 years; 4 with long-QT and 3 with Brugada syndrome) with episodes of ventricular fibrillation or polymorphic ventricular tachycardia and frequent isolated or repetitive premature beats were studied. These premature beats were observed to trigger ventricular arrhythmias and were localized by mapping the earliest endocardial activity. In 4 patients, premature beats originated from the peripheral right (1 Brugada) or left (3 long-QT) Purkinje conducting system and were associated with variable Purkinje-to-muscle conduction times (30 to 110 ms). In the remaining 3 patients, premature beats originated from the right ventricular outflow tract, being 25 to 40 ms ahead of the QRS. The accuracy of mapping was confirmed by acute elimination of premature beats after 12+/-6 minutes of radiofrequency applications. During a follow-up of 17+/-17 months using ambulatory monitoring and defibrillator memory interrogation, no patients had recurrence of symptomatic ventricular arrhythmia but 1 had persistent premature beats. CONCLUSIONS: Triggers from the Purkinje arborization or the right ventricular outflow tract have a crucial role in initiating ventricular fibrillation associated with the long-QT and Brugada syndromes. These can be eliminated by focal radiofrequency ablation.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter , Síndrome do QT Longo/diagnóstico , Fibrilação Ventricular/diagnóstico , Adulto , Arritmias Cardíacas/complicações , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/cirurgia , Masculino , Síncope/etiologia , Síndrome , Resultado do Tratamento , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA