Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Methods Mol Biol ; 2804: 91-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753142

RESUMO

Circulating tumor cells (CTCs) isolated directly from whole blood opens new perspectives for cancer monitoring and the development of personalized treatments. However, due to their rarity among the multitude of blood cells, it remains a challenge to recover them alive with high level of purity, i.e., with few remaining white blood cells, and in a time frame compatible with the clinical context. Microfluidic chips have emerged as promising tools to address these challenges. We propose a two-step workflow including a pre-enrichment step, performed by a size-based pre-enrichment system, and a purification step, performed by an immunomagnetic chip. Here, we describe the protocol for the fabrication of the immunomagnetic microchip, the preparation of the sample, and the procedure for injection into the microchip allowing the sorting of the CTCs.


Assuntos
Separação Imunomagnética , Dispositivos Lab-On-A-Chip , Células Neoplásicas Circulantes , Células Neoplásicas Circulantes/patologia , Separação Imunomagnética/métodos , Humanos , Separação Celular/métodos , Separação Celular/instrumentação , Neoplasias/patologia , Neoplasias/sangue , Linhagem Celular Tumoral , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
2.
Micromachines (Basel) ; 15(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38542626

RESUMO

Given the growing importance of lab-on-a-chip in a number of fields, such as medical diagnosis or environmental analysis, the fact that the current fabrication process relies mainly on oil-based polymers raises an ecological concern. As an eco-responsible alternative, we presented, in this article, a manufacturing process for microfluidic devices from chitosan, a bio-sourced, biodegradable, and biocompatible polysaccharide. From chitosan powder, we produced thick and rigid films. To prevent their dissolution and reduce their swelling when in contact with aqueous solutions, we investigated a film neutralization step and characterized the mechanical and physical properties of the resulting films. On these neutralized chitosan films, we compared two micropatterning methods, i.e., hot embossing and mechanical micro-drilling, based on the resolution of microchannels from 100 µm to 1000 µm wide. Then, chitosan films with micro-drilled channels were bonded using a biocompatible dry photoresist on a glass slide or another neutralized chitosan film. Thanks to this protocol, the first functional chitosan microfluidic devices were prepared. While some steps of the fabrication process remain to be improved, these preliminary results pave the way toward a sustainable fabrication of lab-on-a-chip.

3.
Lab Chip ; 22(21): 4151-4166, 2022 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-36148526

RESUMO

The isolation of circulating tumor cells (CTCs) directly from blood, as a liquid biopsy, could lead to a paradigm shift in cancer clinical care by providing an earlier diagnosis, a more accurate prognosis, and personalized treatment. Nevertheless, CTC-specific challenges, including their rarity and heterogeneity, have hampered the wider use of CTCs in clinical studies. Microfluidic-based isolation technologies have emerged as promising tools to circumvent these limitations but still fail to meet the constraints of high purity and short processing time required to ensure compatibility with clinical follow-up. In this study, we developed an immunomagnetic-based microfluidic device, the MagPure chip, to achieve the negative selection of CTCs through the depletion of white blood cells (WBCs) and provide highly purified samples for subsequent analysis. We demonstrate that the MagPure chip depletes all magnetically labeled WBCs (85% of WBCs were successfully labeled) and ensures a CTC recovery rate of 81%. In addition, we show its compatibility with conventional biological studies, including 2D and 3D cell culture, as well as phenotypic and genotypic analyses. Finally, we successfully implemented a two-step separation workflow for whole blood processing by combining a size-based pre-enrichment system (ClearCell FX1®) with the MagPure chip as a subsequent purification step. The total workflow led to high throughput (7.5 mL blood in less than 4 h) and high purity (947 WBCs per mL remaining, 99.99% depletion rate), thus enabling us to quantify CTC heterogeneity in size and tumor marker expression level. This tumor-marker-free liquid biopsy workflow could be used in a clinical context to assess phenotype aggressiveness and the prognosis rate.


Assuntos
Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patologia , Dispositivos Lab-On-A-Chip , Separação Celular , Linhagem Celular Tumoral , Biópsia Líquida , Biomarcadores Tumorais
4.
Int J Mol Sci ; 23(4)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35216097

RESUMO

The selection of circulating tumor cells (CTCs) directly from blood as a real-time liquid biopsy has received increasing attention over the past ten years, and further analysis of these cells may greatly aid in both research and clinical applications. CTC analysis could advance understandings of metastatic cascade, tumor evolution, and patient heterogeneity, as well as drug resistance. Until now, the rarity and heterogeneity of CTCs have been technical challenges to their wider use in clinical studies, but microfluidic-based isolation technologies have emerged as promising tools to address these limitations. This review provides a detailed overview of latest and leading microfluidic devices implemented for CTC isolation. In particular, this study details must-have device performances and highlights the tradeoff between recovery and purity. Finally, the review gives a report of CTC potential clinical applications that can be conducted after CTC isolation. Widespread microfluidic devices, which aim to support liquid-biopsy-based applications, will represent a paradigm shift for cancer clinical care in the near future.


Assuntos
Biópsia Líquida/métodos , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Células Neoplásicas Circulantes/patologia , Humanos , Dispositivos Lab-On-A-Chip
5.
Biosens Bioelectron ; 197: 113770, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34768065

RESUMO

Cancer is one of the leading cause of death worldwide. Lung cancer (LCa) and prostate cancer (PCa) are the two most common ones particularly among men with about 20% of aggressive metastatic form leading to shorter overall survival. In recent years, circulating tumor cells (CTCs) have been investigated extensively for their role in metastatic progression and their involvement in reduced overall survival and treatment responses. Analysis of these cells and their associated biomarkers as "liquid biopsy" can provide valuable real-time information regarding the disease state and can be a potential avenue for early-stage detection and possible selection of personalized treatments. This review focuses on the role of CTCs and their associated biomarkers in lung and prostate cancer, as well as the shortcomings of conventional methods for their isolation and analysis. To overcome these drawbacks, biosensors are an elegant alternative because they are capable of providing valuable multiplexed information in real-time and analyzing biomarkers at lower concentrations. A comparative analysis of different transducing elements specific for the analysis of cancer cell and cancer biomarkers have been compiled in this review.


Assuntos
Técnicas Biossensoriais , Células Neoplásicas Circulantes , Neoplasias da Próstata , Biomarcadores Tumorais , Humanos , Pulmão , Masculino , Neoplasias da Próstata/diagnóstico
6.
Biomicrofluidics ; 9(5): 054104, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26392836

RESUMO

Enrichment of rare cell populations such as Circulating Tumor Cells (CTCs) is a critical step before performing analysis. This paper presents a polymeric microfluidic device with integrated thick Carbon-PolyDimethylSiloxane composite (C-PDMS) electrodes designed to carry out dielectrophoretic (DEP) trapping of low abundance biological cells. Such conductive composite material presents advantages over metallic structures. Indeed, as it combines properties of both the matrix and doping particles, C-PDMS allows the easy and fast integration of conductive microstructures using a soft-lithography approach while preserving O2 plasma bonding properties of PDMS substrate and avoiding a cumbersome alignment procedure. Here, we first performed numerical simulations to demonstrate the advantage of such thick C-PDMS electrodes over a coplanar electrode configuration. It is well established that dielectrophoretic force ([Formula: see text]) decreases quickly as the distance from the electrode surface increases resulting in coplanar configuration to a low trapping efficiency at high flow rate. Here, we showed quantitatively that by using electrodes as thick as a microchannel height, it is possible to extend the DEP force influence in the whole volume of the channel compared to coplanar electrode configuration and maintaining high trapping efficiency while increasing the throughput. This model was then used to numerically optimize a thick C-PDMS electrode configuration in terms of trapping efficiency. Then, optimized microfluidic configurations were fabricated and tested at various flow rates for the trapping of MDA-MB-231 breast cancer cell line. We reached trapping efficiencies of 97% at 20 µl/h and 78.7% at 80 µl/h, for 100 µm thick electrodes. Finally, we applied our device to the separation and localized trapping of CTCs (MDA-MB-231) from a red blood cells sample (concentration ratio of 1:10).

7.
Biomicrofluidics ; 8(5): 054103, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25332740

RESUMO

This paper reports the use of a recent composite material, noted hereafter i-PDMS, made of carbonyl iron microparticles mixed in a PolyDiMethylSiloxane (PDMS) matrix, for magnetophoretic functions such as capture and separation of magnetic species. We demonstrated that this composite which combine the advantages of both components, can locally generate high gradients of magnetic field when placed between two permanent magnets. After evaluating the magnetic susceptibility of the material as a function of the doping ratio, we investigated the molding resolution offered by i-PDMS to obtain microstructures of various sizes and shapes. Then, we implemented 500 µm i-PDMS microstructures in a microfluidic channel and studied the influence of flow rate on the deviation and trapping of superparamagnetic beads flowing at the neighborhood of the composite material. We characterized the attraction of the magnetic composite by measuring the distance from the i-PDMS microstructure, at which the beads are either deviated or captured. Finally, we demonstrated the interest of i-PDMS to perform magnetophoretic functions in microsystems for biological applications by performing capture of magnetically labeled cells.

8.
Ann Thorac Surg ; 96(5): e111-3, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24182507

RESUMO

Syphilitic cardiovascular disease has been described since the 19th century, mainly on autopsy series. Major clinical manifestations are aortic aneurysm, aortic insufficiency, and coronary ostial stenosis. The diagnosis of syphilitic cardiovascular disease is based mainly on positive serologic tests and overt clinical manifestations. We present here a rare and unusual clinical presentation of a tertiary syphilis with recurrent tamponade and type B aortic dissection, whose positive diagnosis was made by polymerase chain reaction on pericardial fluid analysis.


Assuntos
Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Tamponamento Cardíaco/etiologia , Sífilis/complicações , Feminino , Humanos , Pessoa de Meia-Idade , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA