Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(9)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38731065

RESUMO

Background: This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period. Methods: Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient's eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control. Results: In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals (p < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group. Conclusions: XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

2.
J Glaucoma ; 33(5): 375-380, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38129940

RESUMO

PRCIS: This study showed that the XEN patency should be verified by OCT imaging in cases of encapsulated blebs. Although fibrosis plays the principal role, humor aqueous flow reduction could affect the "spacer" effect that inhibits the fibroblast attachments. PURPOSE: To evaluate the application of the anterior segment optical coherence tomography (AS-OCT) imaging in studying the relationship between a low flow rate through the XEN63 and the development of a cystic bleb. METHODS: Retrospective case series of 3 eyes presenting a cystic bleb after an XEN63 implantation for uncontrolled intraocular pressure (IOP). Demographic and clinical data were obtained from medical records. The imaging findings, complications, and managements following the surgery were evaluated. RESULTS: Three patients, with an average age of 67.3 years, initially showed a patent stent lumen and a functional bleb after surgery. The IOP of all eyes increased on average at 28.3 days from the surgery, with a mean value of 39.66 mm Hg. The slit lamp examination showed a cystic bleb. The AS-OCT imaging confirmed the previous finding and revealed either a partial or total occlusion of the stent internal ostium. A Nd:YAG laser, in proximity to the ostium, was performed to resolve the obstruction. Although the AS-OCT imaging showed the device patency and the IOP immediately decreased, the latter became elevated again. Consequently, in all the cases, a further needling procedure was needed to achieve an adequate IOP reduction. Six months after the two-step procedure, the IOP averaged 13.33 mm Hg, the XEN63 lumens appeared cleared, and the blebs showed a functional morphology. No adverse events were observed. CONCLUSION: The development of a cystic bleb may result from an altered balance between the flow rate through the XEN63 and the fibrosis development in the postoperative healing process. A proper follow-up based on slit lamp biomicroscopy, IOP measurement, and AS-OCT imaging is advisable to estimate and manage a cystic bleb following XEN63 implantation.


Assuntos
Segmento Anterior do Olho , Implantes para Drenagem de Glaucoma , Pressão Intraocular , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Segmento Anterior do Olho/diagnóstico por imagem , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/diagnóstico , Complicações Pós-Operatórias , Estudos Retrospectivos , Stents , Tomografia de Coerência Óptica/métodos , Tonometria Ocular
3.
BMC Ophthalmol ; 21(1): 446, 2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-34961501

RESUMO

BACKGROUND: Despite the XEN gel stent low-risk profile, various complications following the implant have been described, including internal and external occlusion, with a consequent postoperative rise in intraocular pressure (IOP). In this case report we aimed to present a XEN45 stent internal occlusion successfully treated by trimming in situ its proximal end with a 25 G vitreous scissors using a bimanual technique. CASE PRESENTATION: A 63-year-old male patient affected by primary open angle glaucoma (IOP = 25 mmHg) and a full thickness macular hole in his right eye, underwent ab-interno Xen gel stent implantation and, 1 month later, a 25 G vitrectomy surgery. Despite a significant IOP reduction after stent implant, 6 days after vitrectomy, IOP increased (25 mmHg) and the conjunctival bleb flattened following occlusion of stent internal ostium by a clot of presumed fibrinous material. The Nd:YAG laser failed to remove the clot, so that we decided to snip a small bit of the proximal end of the Xen tube (about 0,5 mm length) with a 25 G vitreous scissors, using a bimanual technique. In the postoperative day 1 and month 1, the IOP was 8 mmHg and 12 mmHg, respectively. The Anterior Segment OCT confirmed a functional, layered, filtering bleb, and the normal appearance and patency of the XEN proximal segment. No side effects from the intervention were observed. CONCLUSIONS: Ab interno trimming with vitreous scissors of the occluded proximal end of the XEN stent may represent a safe, rapid and efficient method to restore aqueous humor subconjunctival drainage.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Stents , Tonometria Ocular , Resultado do Tratamento
4.
Am J Ophthalmol Case Rep ; 22: 101070, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33763622

RESUMO

PURPOSE: To report an unusual non-iatrogenic case of central macular and posterior full-thickness retinal holes (FTRHs). OBSERVATIONS: A 60-year-old man presented with a progressive visual loss in the right eye. A complete ophthalmological evaluation including best corrected visual acuity (BCVA) measurement, fundus examination and spectral - domain optical coherence tomography (SD-OCT) was performed.Fundus examination and SD-OCT confirmed the presence of simultaneous macular and posterior FTRHs. A 25-gauge vitrectomy was performed and the internal limiting membrane (ILM) was grasped and peeled off around the two holes. A fragment of the peeled-off ILM anchored on the FTRHs edges was left and inserted into the gaps.Closure of both retinal holes was achieved at 1-month, and BCVA improved from 20/630 at baseline to 20/63 at month 3. No intraoperative or postoperative complications were recorded. CONCLUSIONS AND IMPORTANCE: Inverted ILM flap technique represents a good treatment option in this rare non-iatrogenic condition, allowing a good anatomical and functional recovery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA