Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiology ; 309(3): e230425, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38085082

RESUMO

Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.


Assuntos
Neuropatias Amiloides Familiares , Amiloidose , Estenose da Valva Aórtica , Cardiomiopatias , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Pré-Albumina , Estudos Prospectivos , Amiloidose/complicações , Tomografia Computadorizada por Raios X , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/diagnóstico por imagem
2.
Am Heart J ; 261: 51-54, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37011854

RESUMO

The aim of this retrospective analysis was to investigate the prevalence and prognostic importance of incidental malignancy detected during pre-TAVI computed tomography. Among 579 patients, CT-work-up for TAVI exposed previously undetected malignancy in 4.5% of patients. TAVI patients with a new malignancy had a 2.9-fold increased risk of death at 1 year, and a 16 month shorter mean survival time compared to patients with no malignancy.


Assuntos
Estenose da Valva Aórtica , Neoplasias , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Estudos Longitudinais , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes
3.
JAMA Netw Open ; 5(7): e2220689, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35797045

RESUMO

Importance: Noncardiac surgery after transcatheter aortic valve implantation (TAVI) is a clinical challenge with concerns about safety and optimal management. Objectives: To evaluate perioperative risk of adverse events associated with noncardiac surgery after TAVI by timing of surgery, type of surgery, and TAVI valve performance. Design, Setting, and Participants: This cohort study was conducted using data from a prospective TAVI registry of patients at the tertiary care University Hospital in Bern, Switzerland. All patients undergoing noncardiac surgery after TAVI were identified. Data were analyzed from November through December 2021. Exposures: Timing, clinical urgency, and risk category of noncardiac surgery were assessed among patients who had undergone TAVI and subsequent noncardiac surgery. Main Outcomes and Measures: A composite of death, stroke, myocardial infarction, and major or life-threatening bleeding within 30 days after noncardiac surgery. Results: Among 2238 patients undergoing TAVI between 2013 and 2020, 300 patients (mean [SD] age, 81.8 [6.6] years; 144 [48.0%] women) underwent elective (160 patients) or urgent (140 patients) noncardiac surgery after TAVI and were included in the analysis. Of these individuals, 63 patients (21.0%) had noncardiac surgery within 30 days of TAVI. Procedures were categorized into low-risk (21 patients), intermediate-risk (190 patients), and high-risk (89 patients) surgery. Composite end points occurred within 30 days of surgery among 58 patients (Kaplan-Meier estimate, 19.7%; 95% CI, 15.6%-24.7%). There were no significant differences in baseline demographics between patients with the 30-day composite end point and 242 patients without this end point, including mean (SD) age (81.3 [7.1] years vs 81.9 [6.5] years; P = .28) and sex (25 [43.1%] women vs 119 [49.2%] women; P = .37). Timing (ie, ≤30 days from TAVI to noncardiac surgery), urgency, and risk category of surgery were not associated with increased risk of the end point. Moderate or severe prosthesis-patient mismatch (adjusted hazard ratio [aHR], 2.33; 95% CI, 1.37-3.95; P = .002) and moderate or severe paravalvular regurgitation (aHR, 3.61; 95% CI 1.25-10.41; P = .02) were independently associated with increased risk of the end point. Conclusions and Relevance: These findings suggest that noncardiac surgery may be performed early after successful TAVI. Suboptimal device performance, such as prosthesis-patient mismatch and paravalvular regurgitation, was associated with increased risk of adverse outcomes after noncardiac surgery.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Criança , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA