1.
J Chromatogr A ; 1654: 462464, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34438302

RESUMO

The effect of adding ethoxylated sorbitan ester surfactants (Tweens®) to poly(ethylene glycol) diacrylate-based monolithic recipes was investigated. Five different Tweens® have been evaluated to investigate the exact role of non-ionic surfactants in poly(ethylene glycol) diacrylate-based monolith preparations. These monoliths were characterized by scanning electron microscopy, infrared spectroscopy, and nitrogen physisorption analysis. Different morphological features, and surface areas were observed when different types of Tween® were included in the recipe; Tween® 20 and 85 showed small globules, while Tween® 40, 60 and 80 exhibited larger globular structures with different sizes and degrees of coalescence. The different Tween®-based monoliths were investigated for the chromatographic separation of mixtures consisting of hydroxybenzoic acids and alkylbenzenes. These columns were mechanically stable, except for Tween® 80. The highest methylene selectivity and the best overall performance were achieved by Tween® 60. The efficiency was increased by increasing the concentration of the Tween® 60 and the amount of poly(ethylene glycol) diacrylate Mn 700 in the recipes up to 30 wt%, each. Further increases in either Tween® 60 or poly(ethylene glycol) diacrylate Mn 700 led to formation of non-permeable columns. The optimized column was successfully used for separation of mixtures of nonsteroidal anti-inflammatory and sulfa drugs, with a maximum efficiency of 60,000 plates/m.


Assuntos
Técnicas de Química Analítica , Cromatografia , Ésteres , Polissorbatos , Tensoativos , Anti-Inflamatórios não Esteroides/isolamento & purificação , Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Cromatografia/instrumentação , Cromatografia/normas , Ésteres/química , Hidroxibenzoatos , Polissorbatos/química
2.
J Sep Sci ; 36(17): 2782-92, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23813673

RESUMO

Polymer monoliths were prepared in 150 µm id capillaries by thermally initiated polymerization of PEG diacrylate for rapid hydrophobic interaction chromatography of immunoglobulin G (IgG) subclasses and related variants. Using only one monomer in the polymerization mixture allowed ease of optimization and synthesis of the monolith. The performance of the monolith was demonstrated by baseline resolution of IgG subclasses and variants, including mixtures of the κ variants of IgG1, IgG2, and IgG3 as well as the κ and λ variants associated with IgG1 and IgG2. The effect of eluent concentration and pH on the separation efficiency of studied proteins was also explored, allowing almost baseline resolution to be achieved for mixtures of the κ variants of IgG1, IgG2, IgG3, and IgG4 but also for the κ and λ variants of IgG1 and IgG2. The results showed significant improvement in the separations in terms of the tradeoff between analysis time and resolution, while maintaining a simple methodology, in comparison to previous reports. The synthesized monolith was also used for the separation of isoforms of a therapeutic monoclonal antibody.


Assuntos
Cromatografia Líquida/instrumentação , Imunoglobulina G/isolamento & purificação , Polietilenoglicóis/química , Anticorpos Monoclonais/imunologia , Cromatografia Líquida/métodos , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Imunoglobulina G/classificação , Imunoglobulina G/imunologia , Microscopia Eletrônica de Varredura