Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Global Spine J ; 13(2): 425-431, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33631976

RESUMO

STUDY DESIGN: Biomechanical Study. OBJECTIVE: The search for optimal spinal alignment has led to the development of sophisticated formulas and software for preoperative planning. However, preoperative plans are not always appropriately executed since rod contouring during surgery is often subjective and estimated by the surgeon. We aimed to assess whether rods contoured to specific angles with a French rod bender using a template guide will be more accurate than rods contoured without a template. METHODS: Ten experienced spine surgeons were requested to contour two 125 × 5.5 mm Ti64 rods to 40°, 60° and 80° without templates and then 2 more rods using 2D metallic templates with the same angles. Rod angles were then measured for accuracy and compared. RESULTS: Average angles for rods bent without a template to 40°, 60° and 80° were 60.2°, 78.9° and 97.5°, respectively. Without a template, rods were overbent by a mean of 18.9°. When using templates of 40°, 60° and 80°, mean bend angles were 41.5°, 59.1° and 78.7°, respectively, with an average underbend of 0.2°. Differences between the template and non-template groups for each target angle were all significant (p < 0.001). CONCLUSIONS: Without the template, surgeons tend to overbend rods compared to the desired angle, while surgeons improved markedly with a template guide. This tendency to overbend could have significant impact on patient outcomes and risk of proximal junctional failure and warrants further research to better enable surgeons to more accurately execute preoperative alignment plans.

2.
Int J Spine Surg ; 15(s2): S65-S73, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34675031

RESUMO

Robotic assistance in surgical procedures is a valuable tool that enhances the safety and efficacy of invasive surgeries. These devices are divided functionally into surgeon surrogates where the device operates under the direct control of an offsite surgeon, and surgeon adjuncts where the device is an intraoperative guidance tool used in a portion of the procedure. The current state of robotic spine surgery focuses on the latter, addressing the primary task of pedicle screw placement. We would like to share our experience with the Mazor Robotics devices to discuss the underlying concepts, strengths, weaknesses, and results as they pertain to pediatric spine deformity.

3.
Spine Deform ; 9(4): 1021-1027, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33738766

RESUMO

PURPOSE: Intraoperative methadone has been shown to decrease opioid medication requirement following posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS). No study to date has investigated the effect of methadone on opioid medication requirement when used in conjunction with an enhanced recovery after surgery (ERAS) protocol following PSF. METHODS: A retrospective cohort study was performed at a single, tertiary care pediatric hospital. Patients with AIS undergoing PSF were consecutively given a single intra-operative methadone dose and matched 1:2 to a AIS control group without methadone. Patients were matched for age, curve magnitude, levels fused, blood loss, and operating time. All children followed a standard ERAS protocol with methadone being the only change in the post-operative regimen. In-hospital data for opioid and non-opioid medication use, surgical, and patient variables were recorded and compared between cohorts. RESULTS: Twenty-six patients received methadone (average 15.1 ± 1.9 years) and were matched with 52 control patients without methadone (average 14.7 ± 2.2 years). There were no significant differences in total opioid usage at any time-interval prior to hospital discharge or in cumulative opioid usage. Additionally, patients had a similar VAS pain level at discharge (methadone: 4.0 ± 2.3 vs control: 3.8 ± 1.9; P = 0.572). Total opioid usage was correlated with LOS. There were no opioid-related medication complications in either cohort. CONCLUSION: There was no decrease of in-hospital opioid usage when methadone was used with an ERAS protocol. Total opioid usage is correlated with hospital LOS following PSF.


Assuntos
Recuperação Pós-Cirúrgica Melhorada , Escoliose , Fusão Vertebral , Adolescente , Analgésicos Opioides , Criança , Hospitais , Humanos , Metadona , Estudos Retrospectivos , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos
4.
Spine Deform ; 9(4): 1013-1019, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33460022

RESUMO

PURPOSE: Enhanced Recovery after Surgery (ERAS) pathways have been shown to decrease length of stay (LOS) after posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS). The aim of this study was to compare immediate post-operative outcomes following an ERAS pathway with a traditional pathway for AIS. METHODS: A prospective dual-center study of patients treated using an ERAS pathway (203 patients) or a traditional discharge (TD) pathway (73 patients) was performed with focus on pain at discharge, quality of life at one month, and return to school/work. RESULTS: LOS was 55% less in the ERAS group (4.8 days TD vs. 2.2 days ERAS, p < 0.001). Length of surgery (4.8 h TD vs. 2.8 h, p < 0.001) and EBL (500 cc vs. 240 cc, p < 0.001) were greater in the TD group, likely related to larger curve magnitudes ((62.0° TD vs. 54.0° ERAS, p < 0.001), a higher percentage of patients undergoing osteotomies (94% vs. 46%, p < 0.001) and more levels fused (11.4 ± 1.6 vs. 10.1 ± 2.6, p < 0.001) in the TD group. Regression analysis showed no difference in Visual Analog Score (VAS) score at discharge or quality of recovery using the QOR9 instrument between groups at follow up. There was no difference in return to school (p = 0.43) and parents' return to work (p = 0.61) between the groups. CONCLUSION: Patients managed with an ERAS pathway had similar pain scores at discharge than those managed with a TD pathway. Both groups showed evidence of rapid return to normalcy by the first follow up visit.


Assuntos
Recuperação Pós-Cirúrgica Melhorada , Escoliose , Fusão Vertebral , Adolescente , Humanos , Alta do Paciente , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Escoliose/cirurgia
5.
J Neurosurg Pediatr ; 27(2): 213-217, 2020 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-33157524

RESUMO

OBJECTIVE: Posterior spinal fusion (PSF) for adolescent idiopathic scoliosis (AIS) can be associated with significant blood loss. It has been suggested that blood loss is greater in different racial groups. The purpose of this study was to evaluate differences in blood loss between African American and Caucasian patients undergoing PSF for AIS. METHODS: A retrospective review was performed of patients aged 10-18 years with AIS who were treated with PSF from 2014 to 2017 at a single children's healthcare system. Patient demographic, radiographic, and operative data were obtained from medical records. Intraoperative blood loss was calculated using the formula described by Waters et al. Patients who declined reporting their race or had prior spinal surgery, neuromuscular or syndromic diagnoses, a history of cardiac or thoracic surgery, or a bleeding disorder were excluded. Blood loss variables were log-transformed for normality and modeled using multivariable linear regression. RESULTS: A total of 433 PSFs for AIS qualified for the analysis. The average age was 14.1 years, and 73.7% of the patients were female. With respect to race, 44.6% identified themselves as African American. There was no significant difference in blood loss (p = 0.31) or blood loss per level fused (p = 0.36) in African American patients. African American patients, however, did have significantly lower preoperative hemoglobin and hematocrit levels and greater operating room time than Caucasian patients (p < 0.001). There was no difference between race and transfusion rate. CONCLUSIONS: There appears to be no relationship between race and blood loss during PSF for AIS. Standardized protocols for minimizing perioperative blood loss can be applied to both Caucasian and African American patients.


Assuntos
Perda Sanguínea Cirúrgica/estatística & dados numéricos , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Adolescente , Negro ou Afro-Americano , Transfusão de Sangue/estatística & dados numéricos , Criança , Etnicidade , Feminino , Hematócrito , Hemoglobinas/análise , Humanos , Cifose , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos , População Branca
6.
J Bone Joint Surg Am ; 102(13): e66, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32618914

RESUMO

BACKGROUND: Closed reduction and percutaneous pinning (CRPP) of supracondylar humeral fractures is one of the most common procedures performed in pediatric orthopaedics. The use of full, standard preparation and draping with standard personal protective equipment (PPE) may not be necessary during this procedure. This is of particular interest in the current climate as we face unprecedented PPE shortages due to the current COVID-19 pandemic. METHODS: This is a retrospective chart review of 1,270 patients treated with CRPP of a supracondylar humeral fracture at 2 metropolitan pediatric centers by 10 fellowship-trained pediatric orthopaedic surgeons. One surgeon in the group did not wear a mask when performing CRPP of supracondylar humeral fractures, and multiple surgeons in the group utilized a semisterile preparation technique (no sterile gown or drapes). Infectious outcomes were compared between 2 groups: full sterile preparation and semisterile preparation. We additionally analyzed a subgroup of patients who had semisterile preparation without surgeon mask use. Hospital cost data were used to estimate annual cost savings with the adoption of the semisterile technique. RESULTS: In this study, 1,270 patients who underwent CRPP of a supracondylar humeral fracture and met inclusion criteria were identified. There were 3 deep infections (0.24%). These infections all occurred in the group using full sterile preparation and surgical masks. No clinically relevant pin-track infections were noted. There were no known surgeon occupational exposures to bodily fluid. It is estimated that national adoption of this technique in the United States could save between 18,612 and 22,162 gowns and masks with costs savings of $3.7 million to $4.4 million annually. CONCLUSIONS: We currently face critical shortages of PPE due to the COVID-19 pandemic. Data from this large series suggest that a semisterile technique during CRPP of supracondylar humeral fractures is a safe practice. We anticipate that this could preserve approximately 20,000 gowns and masks in the United States over the next year. Physicians are encouraged to reevaluate their daily practice to identify safe opportunities for resource preservation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Infecções por Coronavirus , Fixação de Fratura/normas , Alocação de Recursos para a Atenção à Saúde/organização & administração , Fraturas do Úmero/cirurgia , Pandemias , Equipamento de Proteção Individual/provisão & distribuição , Pneumonia Viral , Infecção da Ferida Cirúrgica/prevenção & controle , Betacoronavirus , Pinos Ortopédicos , COVID-19 , Criança , Pré-Escolar , Redução Fechada/efeitos adversos , Redução Fechada/normas , Feminino , Fixação de Fratura/efeitos adversos , Alocação de Recursos para a Atenção à Saúde/economia , Alocação de Recursos para a Atenção à Saúde/métodos , Humanos , Controle de Infecções/economia , Controle de Infecções/normas , Masculino , Equipamento de Proteção Individual/economia , Estudos Retrospectivos , SARS-CoV-2 , Infecção da Ferida Cirúrgica/etiologia , Estados Unidos/epidemiologia
7.
World J Orthop ; 10(11): 394-403, 2019 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-31840020

RESUMO

BACKGROUND: Magnetically controlled growing rods (MCGR) are a novel treatment option for early onset scoliosis (EOS). Although the complication profile with MCGR use has been reviewed, these reviews do not take into account important implants modifications, termed iterations, that were made due to early on postoperative complications is not well reported or understood. AIM: To assess the effect of MCGR implant iterations on post-operative complications in EOS. METHODS: A systematic review was performed to identify studies investigating MCGR specifically for the treatment of EOS, refined to those reporting the implant iteration, specifically the incorporation of the keeper plate to the implant design. Articles with mixed implant iteration usage were excluded. Complications following surgery were recorded as well as potential risk factors and compared between implant cohorts. RESULTS: Although 20 articles were identified for inclusion, 5 included mixed implant iteration leaving a total of 271 patients identified through 15 clinical studies that met inclusion criteria. The average follow-up was 25.4-mo. Pre-keeper plate implants were utilized in 3 studies with a total of 49 patients. Overall, 115 (42.4%) post-operative complications were identified, with 87% defined as major. The addition of the keeper plate significantly decreased the rate of post-operative complications per study (35.7% vs 80.6%, P = 0.036), and the rate of distraction failure (8.1% vs 40.8%, P = 0.02). Unplanned reoperation occurred in 69 (26.7%) patients but was not different between implant iteration cohorts (25.5% without keeper plate vs 27.1% with keeper plate, P = 0.92). CONCLUSION: MCGR for EOS has a cumulative complication rate of 42.4% but this is significantly reduced to 35.7% when reviewing only keeper-plate enabled implants. However, 25% of published articles included mixed implant iterations. Future studies should discern between implants iterations when reporting on the usage of MCGR for EOS.

8.
Prosthet Orthot Int ; 43(2): 158-162, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30101680

RESUMO

BACKGROUND:: Orthotic treatment for adolescent idiopathic scoliosis is a mainstay in nonoperative treatment to prevent progressive spinal deformity. OBJECTIVE:: To determine the effectiveness of the Providence orthosis in the treatment of adolescent idiopathic scoliosis. STUDY DESIGN:: Retrospective review. METHODS:: Patients treated with a Providence orthosis for adolescent idiopathic scoliosis were reviewed. Inclusion criteria included the following: age of 10-18 years; curve magnitude of 25°-40°; Risser stage of 0-2; and, if female, <1 year post menarche at the time of brace initiation. Failure was defined as curve magnitudes progressing >5° or to >45° or surgery. Radiographs and clinical information were recorded and compared between treatment success and failure cohorts. RESULTS:: 56 patients (51 female and 5 male; average of 12.26 years) were identified with average of 2.21-year follow-up and a 57.1% success rate for preventing curve progression. Factors associated with successful treatment included curve apex T10 and caudal and Risser sign ⩾ 1. Multivariate analysis identified Risser ⩾ 1 and curve apex T10 and caudal as independent predictors of successful treatment. CONCLUSION:: The Providence nighttime orthosis can be an effective treatment for adolescent idiopathic scoliosis. Curve Apex at T10 or caudal was an independent predictors of treatment success. CLINICAL RELEVANCE: This study identifies variables associated with treatment success using the Providence nighttime orthosis in a consecutive series of adolescent idiopathic scoliosis patients. This information provides the foundation for identifying ideal patients for nighttime bracing to guide clinical treatment.


Assuntos
Braquetes/estatística & dados numéricos , Aparelhos Ortopédicos , Escoliose/terapia , Adolescente , Análise de Variância , Criança , Ritmo Circadiano , Estudos de Coortes , Desenho de Equipamento , Feminino , Humanos , Vértebras Lombares/fisiopatologia , Região Lombossacral , Masculino , Cooperação do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Escoliose/diagnóstico , Vértebras Torácicas/fisiopatologia , Resultado do Tratamento
9.
Spine Deform ; 7(1): 158-162, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30587310

RESUMO

BACKGROUND: Children with congenital heart disease (CHD) have been reported to be at increased risk of developing scoliosis following cardiac surgery. Previous sample studies have reported that these patients may safely undergo posterior spinal fusion (PSF) with low complication rates. The goal of this study is to provide an updated analysis of the perioperative complication profile for posterior spinal fusion in a large cohort of pediatric patients with CHD, using a nationwide database. METHODS: A retrospective cohort study was conducted using 30-day perioperative outcomes data from the NSQIP-P database. Our inclusion criteria were all pediatric patients who underwent posterior spinal fusion by CPT code. Patients were subdivided into two groups: those with a history of cardiac surgery for CHD and those without. Postoperative complications were classified according to the Clavien-Dindo system. Risk factors were assessed in univariate and multivariate logistic regression analyses, with significance set at p < .05. RESULTS: Our results included 3,426 pediatric patients (68.2% female, 31.8% male) with a median age at spinal fusion of 13.7 ± 2.87 years. A CHD diagnosis was present in 312 patients, with 128 having had prior cardiac surgery. The overall complication rate was 6.68%, with a 10.9% rate in the prior cardiac surgery cohort (p = .068). The most common overall perioperative complications were unplanned readmission (3.5%), reoperation (2.6%), and superficial wound dehiscence (2.5%). Patients with a history of cardiac surgery were not at increased risk for postoperative complications; however, blood transfusion (p < .001), bronchopulmonary dysplasia (p < .001), combined bronchopulmonary dysplasia and previous cardiac surgery (p = .004), and a neuromuscular diagnosis (p < .001) were all risk factors for major postoperative complications in this cohort. CONCLUSIONS: Children with scoliosis who have undergone cardiac surgery to address CHD are not at an increased risk of perioperative complications within 30 days of undergoing a posterior spinal fusion. However, patients who underwent cardiac surgery for CHD who also had bronchopulmonary dysplasia or an associated neuromuscular diagnosis are at increased risk for perioperative complications. It is important for pediatric orthopedic spine surgeons to be familiar with an updated profile of potential perioperative obstacles they may face when treating these patients, as seen in a large and representative cohort. LEVEL OF EVIDENCE: Level III.


Assuntos
Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Cardiopatias Congênitas/cirurgia , Complicações Pós-Operatórias/etiologia , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Adolescente , Transfusão de Sangue/estatística & dados numéricos , Displasia Broncopulmonar/etiologia , Criança , Bases de Dados Factuais , Feminino , Cardiopatias Congênitas/complicações , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Doenças Neuromusculares/etiologia , Estudos Retrospectivos , Fatores de Risco , Escoliose/congênito , Resultado do Tratamento
10.
J Spine Surg ; 4(2): 187-194, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30069506

RESUMO

BACKGROUND: Screw malpositioning is an identifiable cause of intraoperative neurophysiologic changes. Although triggered screw electromyography (t-EMG) has been found to exhibit high sensitivity for identifying malpositioned screws, no previous study has assessed the utility of combining t-EMG with robotic-assisted pedicle screw placement for identifying malpositioned screws. We sought to evaluate the utility of t-EMG used in combination with robotic-assisted pedicle screw placement for identifying malpositioned screws in patients with adolescent idiopathic scoliosis (AIS). METHODS: Patients undergoing robotic-assisted posterior spinal fusion with pedicle screw fixation for AIS underwent retrospective review from a single surgeons prospectively collected database. Preoperative demographic data and curve characteristics were recorded. Computed tomography (CT) scans were reviewed, measuring pedicle width and classifying pedicle morphology using the channel classification system. Pedicle data was compared against intra-operative t-EMG data, with a minimal threshold of 8 mA used for screw removal and screw path examination and the rate of screw re-direction recorded. All pedicle screws were verified using image intensification. RESULTS: Forty-nine patients (11 males, 38 females, average age 14.49 years) with an average curve magnitude of 51 degrees and placement of 844 pedicle screws to attain an average curve correction of 67.7%. The incidence of an absent pedicle (type C or D morphology) was 2%. Overall, 24 screws (2.8%) were identified with an abnormal t-EMG threshold. All screws were found to have an intact medial wall upon probing and were reinserted without re-direction. No patient or curve characteristic was predictive of abnormal t-EMG amplitude but smaller pedicles correlated with smaller amplitudes. CONCLUSIONS: With precise pre-operative planning, robotic-assisted pedicle screw placement has shown to be a safe and effective method in treating AIS patients as shown by the lack of medial pedicle breach and malpositioned screws. We found no evidence to support combined use of t-EMG for identifying medially malpositioned screws.

11.
J Child Orthop ; 8(3): 257-63, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24770995

RESUMO

OBJECTIVE: To evaluate the clinical and economic impact of a novel postoperative pathway following posterior spinal fusion (PSF) in patients with adolescent idiopathic scoliosis (AIS). METHODS: Patient charts were reviewed for demographic data and to determine length of surgery, implant density, use of osteotomies, estimated blood loss, American Society of Anesthesiologists (ASA) score, length of hospital stay, and any subsequent complications. Hospital charges were divided by charge code to evaluate potential savings. RESULTS: Two hundred and seventy-nine of 365 patients (76.4 %) treated with PSF carried a diagnosis of AIS and had completed 6 months of clinical and radiologic follow-up, a period of time deemed adequate to assess early complications. There was no difference between groups in age at surgery, sex, number of levels fused, or length of follow-up. Patients managed under the accelerated discharge (AD) pathway averaged 1.36 (31.7 %) fewer days of inpatient stay. Operative time was associated with a shorter length of stay. There was no difference in complications between groups. Hospital charges for room and board were significantly less in the AD group ($1.885 vs. $2,779, p < 0.001). CONCLUSIONS: A pathway aimed to expedite discharge following PSF for AIS decreased hospital stay by nearly one-third without any increase in early complication rate. A small but significant decrease in hospital charges was seen following early discharge. Early discharge following PSF for AIS may be achieved without increased risk of complications, while providing a small cost savings.

12.
Spine (Phila Pa 1976) ; 35(24): 2109-15, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-21079498

RESUMO

STUDY DESIGN: Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. OBJECTIVE: To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SUMMARY OF BACKGROUND DATA: SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. METHODS: Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. RESULTS: Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. CONCLUSION: SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.


Assuntos
Parafusos Ósseos , Procedimentos Ortopédicos/instrumentação , Robótica , Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Desenho de Equipamento , Feminino , Fluoroscopia , Alemanha , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Procedimentos Ortopédicos/efeitos adversos , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Coluna Vertebral/diagnóstico por imagem , Cirurgia Assistida por Computador/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Estados Unidos , Adulto Jovem
13.
J Pediatr Orthop ; 30(8): 799-806, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21102204

RESUMO

BACKGROUND: The purpose of this study is to compare the efficacy of medial and lateral (crossed pin) and lateral-entry pin techniques for Gartland Type 3 supracondylar humerus fractures in children. METHODS: Six pediatric orthopaedists were divided into the 2 treatment groups (medial and lateral pins or lateral only pins) based on pre-study pinning technique preferences. Patients were randomized into 1 of the 2 pinning technique treatment groups based on which attending was on call at the time of patient presentation. One hundred and four patients met inclusion criteria. Forty-seven patients underwent lateral-entry pinning and 57 underwent crossed pinning. The 2 groups were similar with respect to age, sex, preoperative neurovascular injury, direction of fracture displacement, and timing of surgery. Outcome parameters measured included radiographic maintenance of reduction, iatrogenic neurovascular complications, and rate of infection. All radiographic measurements, and interobserver reliability, were determined by a 3 physician panel. RESULTS: The results of the interobserver reliability data showed a strong correlation and this data allowed 95% confidence that a change in Baumann's angle of more than 6 degrees and humerocapitellar angle of more than 10 degrees was significant. The lateral-entry patients experienced a median absolute change of Baumann's angle of 3.7 degrees with 12 patients having greater than 6 degrees loss of reduction; whereas those in the medial and lateral-pin group saw a median change of 2.9 degrees with 10 patients having greater than 6 degrees loss of reduction. In terms of the humerocapitellar angle, the lateral-entry patients experienced a median absolute change of 4.8 degrees with 11 patients having greater than 10 degrees loss of reduction; whereas those in the medial and lateral-pin groups saw a median change of 5.1 degrees with 17 patients having greater than 10 degrees loss of reduction. There was no significant difference in infection rate between the 2 groups but 2 cases of iatrogenic neurovascular injury occurred in patients who had a medial pin placed. CONCLUSIONS: We found no statistical difference in the radiographic outcomes between lateral-entry and medial and lateral-pin techniques for the management of Type 3 supracondylar fractures in children when evaluated in this prospective and surgeon-randomized trial, but 2 cases of iatrogenic injury to the ulnar nerve occurred with medially placed pins. LEVEL OF EVIDENCE: Level 2.


Assuntos
Pinos Ortopédicos , Fraturas do Úmero/cirurgia , Criança , Pré-Escolar , Feminino , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Humanos , Fraturas do Úmero/classificação , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA