Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Acta Orthop Belg ; 87(4): 795-803, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35172450

RESUMO

Dynesys® is a dynamic device used for posterior stabilization of the lumbar spine. The objective of this study was to analyze the clinical and radiological outcomes at a 2-year minimum follow-up. In this retrospective study, patients operated between 2009 and 2016 with Dynesys® stabilization were included. 5 different etiologies were included: disc herniation, lumbar stenosis, revision for adjacent seg- ment disease (ASD), spondylolisthesis, and scoliosis. Clinical and radiological evaluations were performed. Postoperative complications and revisions were recorded. 136 patients were included: 34 for lumbar spinal stenosis, 19 for disc herniation, 29 degenerative spon- dylolisthesis, 41 revisions for ASD, and 13 scoliosis. Mean age was 64.8. Average clinical follow-up was 46 months. Postoperative clinical results showed a mean lumbar VAS of 3.07, a mean radicular VAS of 3.01 and an ODI score of 31.8%. The ASD rate was 16.2%, and overall revision rate was 11.8%. 2 cases (1.5%) of screw loosening were identified. Clinical outcomes, ASD rate and revision rate were more favorable in the spondylolisthesis and disc herniation groups. This study has one of the largest Dynesys® cohort in literature. Spinal dynamic stabilization by Dynesys® presents good long-term clinical and radiological out- comes with a lower rate of complications than pre- viously published cohorts and lumbar fusions. Best indications seem to be degenerative spondylolisthesis.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Estenose Espinal , Espondilolistese , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Fusão Vertebral/métodos , Estenose Espinal/diagnóstico por imagem , Estenose Espinal/cirurgia , Espondilolistese/diagnóstico por imagem , Espondilolistese/cirurgia , Resultado do Tratamento
2.
Clin Orthop Relat Res ; 474(2): 520-7, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26341897

RESUMO

BACKGROUND: Poor survival of THA implants in very young patients has been attributed to use of cemented implants, wear of conventional polyethylene, and the presence of morphologic deformities in the proximal femur or in the acetabulum. Few studies have reported the long-term results of ceramic-on-ceramic implants in THAs in patients younger than 20 years. QUESTION/PURPOSES: We determined: (1) the proportion of patients who experienced complications related to the ceramic bearing (squeaking, fracture); (2) the survivorship free from loosening and free from revision for any reason; (3) whether patients with osteonecrosis had inferior survivorship compared with patients whose surgical indication was all other diagnoses including sequelae of pediatric hip disorders (developmental dysplasia of the hip, Legg-Calvé-Perthes disease, slipped capital femoral epiphysis); and (4) clinical function. METHODS: Between 1979 and 2013, we performed 113 primary THAs in 91 patients younger than 20 years at the time of surgery. Of those, 105 THAs (83 patients) were done with ceramic-on-ceramic bearings (91% of the 91 patients); during that period, a ceramic-on-ceramic bearing couple was indicated in all patients younger than 20 years. In eight patients (eight hips), a cemented polyethylene cup was implanted because the diameter of the acetabulum was smaller than the smallest available ceramic cup (46 mm), or because adequate fixation of a ceramic press-fit cup could not be achieved despite careful reaming of the acetabulum. The most common diagnosis indicating THA was avascular necrosis of the femoral head (56.2%; 59 hips). Thirty-five patients (40 hips) had undergone previous operations before the replacement. Three patients (4%; four hips) died from unrelated causes, nine patients (11%; 13 hips) were lost to followup, and four patients (five hips) had a followup greater than 8.5 years but have not been seen in the last 5 years. Patients were assessed clinically (using the Merle d'Aubigne-Postel score, Hip disability and Osteoarthritis Outcome score (HOOS), and the SF-12(®) Health Survey, and radiographically for signs of radiolucencies, subsidence, or osteolysis on plain films. The mean followup was 8.8 ± 6.1 years (range, 2-34.4 years). RESULTS: Five patients experienced transient noise generation, defined as a snap in four patients and squeaking in one. Seventeen hips underwent revision surgery-16 for aseptic loosening and one for septic loosening. The implant survival rate at 10 years with aseptic loosening as the endpoint was 90.3% (95% CI, 82.4%-98.9%). No hip had acetabular or femoral osteolysis. Survivorship in patients with osteonecrosis did not differ from survivorship in patients with other diagnoses. The Merle d'Aubigne-Postel score increased from 10.1 ± 4.0 to 17.6 ± 1.1 (p < 0.01); the mean HOOS score was 79.3 ± 13.8 (range, 50.6-100); the mean SF-12(®) physical and mental component scores were 48.1 ± 7.9 (range, 21.4-57.6), and 47.4 ± 12.2 (range, 24.5-99.4), respectively. CONCLUSIONS: We found that patient-reported outcomes scores improved in most patients undergoing THA in this very young study group. Underlying diagnosis did not affect long-term survivorship. However, the revision-free survival rate at 10 years is lower than published estimates in older patients, and with 11% of patients lost to followup, our estimates may represent a best-case scenario. Therefore, we believe THA should be performed as a last resort in this population. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Articulação do Quadril/cirurgia , Prótese de Quadril , Adolescente , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Cimentos Ósseos/uso terapêutico , Avaliação da Deficiência , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Desenho de Prótese , Falha de Prótese , Radiografia , Recuperação de Função Fisiológica , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA