Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
3.
PLoS One ; 15(12): e0243207, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33264359

RESUMO

BACKGROUND: Intramyocardial hemorrhage following reperfusion is strongly associated with major adverse cardiovascular events in myocardial infarction (MI) patients; yet the mechanisms contributing to these outcomes are not well understood. Large animal models have been used to investigate intramyocardial hemorrhage, but they are exorbitantly expensive and difficult to use for mechanistic studies. In contrast, rat models are widely used to investigate mechanistic aspects of cardiovascular physiology, but a rat model that consistently recapitulates the characteristics of an hemorrhagic MI does not exist. To bridge this gap, we investigated the physiological conditions of MI that would create intramyocardial hemorrhage in rats so that a reliable model of hemorrhagic MI would become available for basic research. METHODS & RESULTS: Sprague-Dawley rats underwent either a 90-minute (90-min) ischemia and then reperfusion (I/R) (n = 22) or 30-minute (30-min) I/R (n = 18) of the left anterior descending coronary artery. Sham rats (n = 12) were used as controls. 90-min I/R consistently yielded hemorrhagic MI, while 30-min I/R consistently yielded non-hemorrhagic MI. Twenty-four hours post-reperfusion, ex-vivo late-gadolinium-enhancement (LGE) and T2* cardiac MRI performed on excised hearts from 90-min I/R rats revealed colocalization of iron deposits within the scarred tissue; however, in 30-min I/R rats scar was evident on LGE but no evidence of iron was found on T2* CMR. Histological studies verified tissue damage (H&E) detected on LGE and the presence of iron (Perl's stain) observed on T2*-CMR. At week 4 post-reperfusion, gene and protein expression of proinflammatory markers (TNF-α, IL-1ß and MMP-9) were increased in the 90-min I/R group when compared to 30-min I/R groups. Further, transmission electron microscopy performed on 90-min I/R myocardium that were positive for iron on T2* CMR and Perl's stain showed accumulation of granular iron particles within the phagosomes. CONCLUSION: Ischemic time prior to reperfusion is a critical factor in determining whether a MI is hemorrhagic or non-hemorrhagic in rats. Specifically, a period of 90-min of ischemia prior to reperfusion can produce rat models of hemorrhagic MI, while 30-minutes of ischemia prior to reperfusion can ensure that the MIs are non-hemorrhagic. Hemorrhagic MIs in rats result in marked increase in iron deposition, proinflammatory burden and adverse left-ventricular remodeling compared to rats with non-hemorrhagic MIs.


Assuntos
Biomarcadores/metabolismo , Hemorragia/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/complicações , Animais , Modelos Animais de Doenças , Gadolínio/administração & dosagem , Hemorragia/etiologia , Hemorragia/genética , Hemorragia/metabolismo , Interleucina-1beta/genética , Interleucina-1beta/metabolismo , Imagem Cinética por Ressonância Magnética , Masculino , Metaloproteinase 9 da Matriz/genética , Metaloproteinase 9 da Matriz/metabolismo , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/genética , Infarto do Miocárdio/metabolismo , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/metabolismo , Regulação para Cima
4.
Radiology ; 295(1): 82-93, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32096705

RESUMO

Background Despite advances, blood oxygen level-dependent (BOLD) cardiac MRI for myocardial perfusion is limited by inadequate spatial coverage, imaging speed, multiple breath holds, and imaging artifacts, particularly at 3.0 T. Purpose To develop and validate a robust, contrast agent-unenhanced, free-breathing three-dimensional (3D) cardiac MRI approach for reliably examining changes in myocardial perfusion between rest and adenosine stress. Materials and Methods A heart rate-independent, free-breathing 3D T2 mapping technique at 3.0 T that can be completed within the period of adenosine stress (≤4 minutes) was developed by using computer simulations, ex vivo heart preparations, and dogs. Studies in dogs were performed with and without coronary stenosis and validated with simultaneously acquired nitrogen 13 (13N) ammonia PET perfusion in a clinical PET/MRI system. The MRI approach was also prospectively evaluated in healthy human volunteers (from January 2017 to September 2017). Myocardial BOLD responses (MBRs) between normal and ischemic myocardium were compared with mixed model analysis. Results Dogs (n = 10; weight range, 20-25 kg; mongrel dogs) and healthy human volunteers (n = 10; age range, 22-53 years; seven men) were evaluated. In healthy dogs, T2 MRI at adenosine stress was greater than at rest (mean rest vs stress, 38.7 msec ± 2.5 [standard deviation] vs 45.4 msec ± 3.3, respectively; MBR, 1.19 ± 0.08; both, P < .001). At the same conditions, mean rest versus stress PET perfusion was 1.1 mL/mg/min ± 0.11 versus 2.3 mL/mg/min ± 0.82, respectively (P < .001); myocardial perfusion reserve (MPR) was 2.4 ± 0.82 (P < .001). The BOLD response and PET MPR were positively correlated (R = 0.67; P < .001). In dogs with coronary stenosis, perfusion anomalies were detected on the basis of MBR (normal vs ischemic, 1.09 ± 0.05 vs 1.00 ± 0.04, respectively; P < .001) and MPR (normal vs ischemic, 2.7 ± 0.08 vs 1.7 ± 1.1, respectively; P < .001). Human volunteers showed increased myocardial T2 at stress (rest vs stress, 44.5 msec ± 2.6 vs 49.0 msec ± 5.5, respectively; P = .004; MBR, 1.1 msec ± 8.08). Conclusion This three-dimensional cardiac blood oxygen level-dependent (BOLD) MRI approach overcame key limitations associated with conventional cardiac BOLD MRI by enabling whole-heart coverage within the standard duration of adenosine infusion, and increased the magnitude and reliability of BOLD contrast, which may be performed without requiring breath holds. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Almeida in this issue.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Frequência Cardíaca , Coração/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Tomografia por Emissão de Pósitrons , Adenosina , Adulto , Amônia , Animais , Meios de Contraste , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Cães , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Adulto Jovem
5.
J Nucl Med ; 58(6): 953-960, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28254864

RESUMO

Myocardial blood flow (MBF) is the critical determinant of cardiac function. However, its response to increases in partial pressure of arterial CO2 (PaCO2), particularly with respect to adenosine, is not well characterized because of challenges in blood gas control and limited availability of validated approaches to ascertain MBF in vivo. Methods: By prospectively and independently controlling PaCO2 and combining it with 13N-ammonia PET measurements, we investigated whether a physiologically tolerable hypercapnic stimulus (∼25 mm Hg increase in PaCO2) can increase MBF to that observed with adenosine in 3 groups of canines: without coronary stenosis, subjected to non-flow-limiting coronary stenosis, and after preadministration of caffeine. The extent of effect on MBF due to hypercapnia was compared with adenosine. Results: In the absence of stenosis, mean MBF under hypercapnia was 2.1 ± 0.9 mL/min/g and adenosine was 2.2 ± 1.1 mL/min/g; these were significantly higher than at rest (0.9 ± 0.5 mL/min/g, P < 0.05) and were not different from each other (P = 0.30). Under left-anterior descending coronary stenosis, MBF increased in response to hypercapnia and adenosine (P < 0.05, all territories), but the effect was significantly lower than in the left-anterior descending coronary territory (with hypercapnia and adenosine; both P < 0.05). Mean perfusion defect volumes measured with adenosine and hypercapnia were significantly correlated (R = 0.85) and were not different (P = 0.12). After preadministration of caffeine, a known inhibitor of adenosine, resting MBF decreased; and hypercapnia increased MBF but not adenosine (P < 0.05). Conclusion: Arterial blood CO2 tension when increased by 25 mm Hg can induce MBF to the same level as a standard dose of adenosine. Prospectively targeted arterial CO2 has the capability to evolve as an alternative to current pharmacologic vasodilators used for cardiac stress testing.


Assuntos
Adenosina/administração & dosagem , Dióxido de Carbono/sangue , Estenose Coronária/sangue , Estenose Coronária/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Animais , Cães , Teste de Esforço/métodos , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vasodilatadores
6.
Circ Cardiovasc Imaging ; 9(11)2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27903536

RESUMO

BACKGROUND: Emerging evidence indicates that persistent microvascular obstruction (PMO) is more predictive of major adverse cardiovascular events than myocardial infarct (MI) size. But it remains unclear how PMO, a phenomenon limited to the acute/subacute period of MI, drives adverse remodeling in chronic MI setting. We hypothesized that PMO resolves into chronic iron crystals within MI territories, which in turn are proinflammatory and favor adverse remodeling post-MI. METHODS AND RESULTS: Canines (n=40) were studied with cardiac magnetic resonance imaging to characterize the spatiotemporal relationships among PMO, iron deposition, infarct resorption, and left ventricular remodeling between day 7 (acute) and week 8 (chronic) post-MI. Histology was used to assess iron deposition and to examine relationships between iron content with macrophage infiltration, proinflammatory cytokine synthesis, and matrix metalloproteinase activation. Atomic resolution transmission electron microscopy was used to determine iron crystallinity, and energy-dispersive X-ray spectroscopy was used to identify the chemical composition of the iron composite. PMO with or without reperfusion hemorrhage led to chronic iron deposition, and the extent of this deposition was strongly related to PMO volume (r>0.8). Iron deposits were found within macrophages as aggregates of nanocrystals (≈2.5 nm diameter) in the ferric state. Extent of iron deposits was strongly correlated with proinflammatory burden, collagen-degrading enzyme activity, infarct resorption, and adverse structural remodeling (r>0.5). CONCLUSIONS: Crystallized iron deposition from PMO is directly related to proinflammatory burden, infarct resorption, and adverse left ventricular remodeling in the chronic phase of MI in canines. Therapeutic strategies to combat adverse remodeling could potentially benefit from taking into account the chronic iron-driven inflammatory process.


Assuntos
Circulação Coronária , Compostos Férricos/metabolismo , Mediadores da Inflamação/metabolismo , Microcirculação , Infarto do Miocárdio/complicações , Traumatismo por Reperfusão Miocárdica/etiologia , Miocárdio/metabolismo , Função Ventricular Esquerda , Remodelação Ventricular , Animais , Cristalização , Modelos Animais de Doenças , Cães , Macrófagos/metabolismo , Macrófagos/patologia , Imageamento por Ressonância Magnética , Microscopia Eletrônica de Transmissão , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miocárdio/patologia , Espectrometria por Raios X , Fatores de Tempo
8.
J Am Heart Assoc ; 5(2)2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26857066

RESUMO

BACKGROUND: Infusion of allogeneic cardiosphere-derived cells (allo-CDCs) postreperfusion elicits cardioprotective cellular postconditioning in pigs with acute myocardial infarction. However, the long-term effects of allo-CDCs have not been assessed. We performed a placebo-controlled pivotal study for long-term evaluation, as well as shorter-term mechanistic studies. METHODS AND RESULTS: Minipigs underwent 1.5-hour mid-left anterior descending balloon occlusion followed by reperfusion and were randomized to receive intracoronary allo-CDCs or vehicle 30 minutes postreperfusion. Left ventriculography (LVG) demonstrated preserved ejection fraction (EF) and attenuation of LV remodeling in CDC-treated pigs. Pigs underwent cardiac magnetic resonance imaging (MRI) and LVG 1 hour and 8 weeks after therapy to evaluate efficacy. MRI showed improvement of EF and attenuation of LV remodeling immediately after allo-CDC infusion. In addition, allo-CDCs improved regional function and decreased hypertrophy 2 months post-treatment. Histological analysis revealed increased myocardial salvage index, enhanced vascularity, sustained reductions in infarct size/area at risk and scar transmurality, and attenuation of collagen deposition in the infarct zone of allo-CDC-treated pigs at 2 months. Allo-CDCs did not evoke lymphohistiocytic infiltration or systemic humoral memory response. Short-term experiments designed to probe mechanism revealed antiapoptotic effects of allo-CDCs on cardiomyocytes and increases in cytoprotective macrophages, but no increase in overall inflammatory cell infiltration 2 hours after cell therapy. CONCLUSIONS: Allo-CDC infusion postreperfusion is safe, improves cardiac function, and attenuates scar size and remodeling. The favorable effects persist for at least 2 months after therapy. Thus, cellular postconditioning confers not only acute cardioprotection, but also lasting structural and functional benefits.


Assuntos
Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Reperfusão Miocárdica , Miocárdio/patologia , Miócitos Cardíacos/transplante , Animais , Apoptose , Biópsia , Células Cultivadas , Modelos Animais de Doenças , Macrófagos/patologia , Imageamento por Ressonância Magnética , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Reperfusão Miocárdica/efeitos adversos , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miócitos Cardíacos/patologia , Volume Sistólico , Suínos , Porco Miniatura , Fatores de Tempo , Transplante Homólogo , Função Ventricular Esquerda , Remodelação Ventricular
9.
Artigo em Inglês | MEDLINE | ID: mdl-26259581

RESUMO

BACKGROUND: Recent canines studies have shown that iron deposition within chronic myocardial infarction (CMI) influences the electric behavior of the heart. To date, the link between the iron deposition and malignant ventricular arrhythmias in humans with CMI is unknown. METHODS AND RESULTS: Patients with CMI (n=94) who underwent late-gadolinium-enhanced cardiac magnetic resonance imaging before implantable cardioverter-defibrillator implantation for primary and secondary preventions were retrospectively analyzed. The predictive values of hypointense cores (HIC) in balanced steady-state free precession images and conventional cardiac magnetic resonance imaging and ECG malignant ventricular arrhythmia parameters for the prediction of primary combined outcome (appropriate implantable cardioverter-defibrillator therapy, survived cardiac arrest, or sudden cardiac death) were studied. The use of HIC within CMI on balanced steady-state free precession as a marker of iron deposition was validated in a canine MI model (n=18). Nineteen patients met the study criteria with events occurring at a median of 249 (interquartile range of 540) days after implantable cardioverter-defibrillator placement. Of the 19 patients meeting the primary end point, 18 were classified as HIC+, whereas only 1 was HIC-. Among the cohort in whom the primary end point was not met, there were 28 HIC+ and 47 HIC- patients. Receiver operating characteristic curve analysis demonstrated an additive predictive value of HIC for malignant ventricular arrhythmias with an increased area under the curve of 0.87 when added to left ventricular ejection fraction (left ventricular ejection fraction alone, 0.68). Both cardiac magnetic resonance imaging and histological validation studies performed in canines demonstrated that HIC regions in balanced steady-state free precession images within CMI likely result from iron depositions. CONCLUSIONS: Hypointense cores within CMI on balanced steady-state free precession cardiac magnetic resonance imaging can be used as a marker of iron deposition and yields incremental information toward improved prediction of malignant ventricular arrhythmias.


Assuntos
Ferro/metabolismo , Imageamento por Ressonância Magnética , Infarto do Miocárdio/complicações , Miocárdio/metabolismo , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia , Idoso , Animais , Área Sob a Curva , Meios de Contraste , Desfibriladores Implantáveis , Cães , Cardioversão Elétrica/instrumentação , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Miocárdio/patologia , Compostos Organometálicos , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/metabolismo , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/prevenção & controle , Função Ventricular Esquerda
10.
Magn Reson Med ; 74(6): 1661-74, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26052843

RESUMO

PURPOSE: To develop and test the feasibility of a new method for non-ECG-gated first-pass perfusion (FPP) cardiac MR capable of imaging multiple short-axis slices at the same systolic cardiac phase. METHODS: A magnetization-driven pulse sequence was developed for non-ECG-gated FPP imaging without saturation-recovery preparation using continuous slice-interleaved radial sampling. The image reconstruction method, dubbed TRACE, used self-gating based on reconstruction of a real-time image-based navigator combined with reference-constrained compressed sensing. Data from ischemic animal studies (n = 5) was used in a simulation framework to evaluate temporal fidelity. Healthy subjects (n = 5) were studied using both the proposed approach and the conventional method to compare the myocardial contrast-to-noise ratio (CNR). Patients (n = 2) underwent adenosine stress studies using the proposed method. RESULTS: Temporal fidelity of the developed method was shown to be sufficient at high heart-rates. The healthy volunteers studies demonstrated normal perfusion and no dark-rim artifacts. Compared with the conventional scheme, myocardial CNR for the proposed method was slightly higher (8.6 ± 0.6 versus 8.0 ± 0.7). Patient studies showed stress-induced perfusion defects consistent with invasive angiography. CONCLUSION: The presented methods and results demonstrate feasibility of the proposed approach for high-resolution non-ECG-gated FPP imaging of 3 myocardial slices at the same systolic phase, and indicate its potential for achieving desirable image quality (high CNR and no dark-rim artifacts).


Assuntos
Doença da Artéria Coronariana/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Isquemia Miocárdica/patologia , Imagem de Perfusão do Miocárdio/métodos , Adulto , Algoritmos , Animais , Técnicas de Imagem de Sincronização Cardíaca , Cães , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
11.
Radiology ; 272(2): 397-406, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24749715

RESUMO

PURPOSE: To examine whether controlled and tolerable levels of hypercapnia may be an alternative to adenosine, a routinely used coronary vasodilator, in healthy human subjects and animals. MATERIALS AND METHODS: Human studies were approved by the institutional review board and were HIPAA compliant. Eighteen subjects had end-tidal partial pressure of carbon dioxide (PetCO2) increased by 10 mm Hg, and myocardial perfusion was monitored with myocardial blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging. Animal studies were approved by the institutional animal care and use committee. Anesthetized canines with (n = 7) and without (n = 7) induced stenosis of the left anterior descending artery (LAD) underwent vasodilator challenges with hypercapnia and adenosine. LAD coronary blood flow velocity and free-breathing myocardial BOLD MR responses were measured at each intervention. Appropriate statistical tests were performed to evaluate measured quantitative changes in all parameters of interest in response to changes in partial pressure of carbon dioxide. RESULTS: Changes in myocardial BOLD MR signal were equivalent to reported changes with adenosine (11.2% ± 10.6 [hypercapnia, 10 mm Hg] vs 12% ± 12.3 [adenosine]; P = .75). In intact canines, there was a sigmoidal relationship between BOLD MR response and PetCO2 with most of the response occurring over a 10 mm Hg span. BOLD MR (17% ± 14 [hypercapnia] vs 14% ± 24 [adenosine]; P = .80) and coronary blood flow velocity (21% ± 16 [hypercapnia] vs 26% ± 27 [adenosine]; P > .99) responses were similar to that of adenosine infusion. BOLD MR signal changes in canines with LAD stenosis during hypercapnia and adenosine infusion were not different (1% ± 4 [hypercapnia] vs 6% ± 4 [adenosine]; P = .12). CONCLUSION: Free-breathing T2-prepared myocardial BOLD MR imaging showed that hypercapnia of 10 mm Hg may provide a cardiac hyperemic stimulus similar to adenosine.


Assuntos
Circulação Coronária/fisiologia , Hipercapnia/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adenosina/farmacologia , Animais , Cães , Eletrocardiografia , Humanos , Aumento da Imagem/métodos , Oximetria , Reprodutibilidade dos Testes , Vasodilatadores/farmacologia
12.
Circulation ; 128(25): 2764-75, 2013 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-24061088

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) in the CArdiosphere-Derived aUtologous stem CElls to reverse ventricUlar dySfunction (CADUCEUS) trial revealed that cardiosphere-derived cells (CDCs) decrease scar size and increase viable myocardium after myocardial infarction (MI), but MRI has not been validated as an index of regeneration after cell therapy. We tested the validity of contrast-enhanced MRI in quantifying scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. METHODS AND RESULTS: Yucatan minipigs underwent induction of MI and 2-3 weeks later were randomized to receive intracoronary infusion of 12.5×10(6) mismatched allogeneic CDCs or vehicle. Allogeneic CDCs induced mild local mononuclear infiltration but no systemic immunogenicity. MRI revealed that allogeneic CDCs attenuated remodeling, improved global and regional function, decreased scar size, and increased viable myocardium compared with placebo 2 months post-treatment. Extensive histological analysis validated quantitatively the MRI measurements of scar size, scar mass, and viable mass. CDCs neither altered gadolinium contrast myocardial kinetics nor induced changes in vascular density or architecture in viable and scarred myocardium. Histology demonstrated that CDCs lead to cardiomyocyte hyperplasia in the border zone, consistent with the observed stimulation of endogenous regenerative mechanisms (cardiomyocyte cycling, upregulation of endogenous progenitors, angiogenesis). CONCLUSIONS: Contrast-enhanced MRI accurately measures scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. MRI represents a useful tool for assessing dynamic changes in the infarct and monitoring regenerative efficacy.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos , Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/terapia , Miocárdio/patologia , Regeneração/fisiologia , Animais , Cicatriz/patologia , Modelos Animais de Doenças , Gadolínio , Sistema Imunitário/fisiopatologia , Masculino , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Suínos , Porco Miniatura , Fatores de Tempo , Resultado do Tratamento
13.
PLoS One ; 8(9): e73193, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24066038

RESUMO

PURPOSE: Iron deposition has been shown to occur following myocardial infarction (MI). We investigated whether such focal iron deposition within chronic MI lead to electrical anomalies. METHODS: Two groups of dogs (ex-vivo (n = 12) and in-vivo (n = 10)) were studied at 16 weeks post MI. Hearts of animals from ex-vivo group were explanted and sectioned into infarcted and non-infarcted segments. Impedance spectroscopy was used to derive electrical permittivity ([Formula: see text]) and conductivity ([Formula: see text]). Mass spectrometry was used to classify and characterize tissue sections with (IRON+) and without (IRON-) iron. Animals from in-vivo group underwent cardiac magnetic resonance imaging (CMR) for estimation of scar volume (late-gadolinium enhancement, LGE) and iron deposition (T2*) relative to left-ventricular volume. 24-hour electrocardiogram recordings were obtained and used to examine Heart Rate (HR), QT interval (QT), QT corrected for HR (QTc) and QTc dispersion (QTcd). In a fraction of these animals (n = 5), ultra-high resolution electroanatomical mapping (EAM) was performed, co-registered with LGE and T2* CMR and were used to characterize the spatial locations of isolated late potentials (ILPs). RESULTS: Compared to IRON- sections, IRON+ sections had higher[Formula: see text], but no difference in[Formula: see text]. A linear relationship was found between iron content and [Formula: see text] (p<0.001), but not [Formula: see text] (p = 0.34). Among two groups of animals (Iron (<1.5%) and Iron (>1.5%)) with similar scar volumes (7.28% ± 1.02% (Iron (<1.5%)) vs 8.35% ± 2.98% (Iron (>1.5%)), p = 0.51) but markedly different iron volumes (1.12% ± 0.64% (Iron (<1.5%)) vs 2.47% ± 0.64% (Iron (>1.5%)), p = 0.02), QT and QTc were elevated and QTcd was decreased in the group with the higher iron volume during the day, night and 24-hour period (p<0.05). EAMs co-registered with CMR images showed a greater tendency for ILPs to emerge from scar regions with iron versus without iron. CONCLUSION: The electrical behavior of infarcted hearts with iron appears to be different from those without iron. Iron within infarcted zones may evolve as an arrhythmogenic substrate in the post MI period.


Assuntos
Ferro/metabolismo , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia , Animais , Cães , Capacitância Elétrica , Eletrocardiografia , Sistema de Condução Cardíaco , Imageamento por Ressonância Magnética
14.
Circ Cardiovasc Imaging ; 6(2): 218-28, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23403335

RESUMO

BACKGROUND: Intramyocardial hemorrhage frequently accompanies large reperfused myocardial infarctions. However, its influence on the makeup and the ensuing effect on the infarcted tissue during the chronic phase remain unexplored. METHODS AND RESULTS: Patients (n=15; 3 women), recruited after successful percutaneous coronary intervention for first segment-elevation myocardial infarction, underwent cardiovascular magnetic resonance imaging on day 3 and month 6 after percutaneous coronary intervention. Patients with hemorrhagic (Hemo+) infarctions, as determined by T2* cardiovascular magnetic resonance on day 3 (n=11), showed persistent T2* losses colocalized with scar tissue on the follow-up scans, suggesting chronic iron deposition. T2* values of Hemo+ territories were significantly higher than nonhemorrhagic (Hemo-) and remote territories (P<0.001); however, T2* values of nonhemorrhagic (Hemo-) and remote territories were not different (P=0.51). Canines (n=20) subjected to ischemia-reperfusion injury (n=14) underwent cardiovascular magnetic resonance on days 3 and 56 after ischemia-reperfusion injury. Similarly, sham-operated animals (Shams; n=3) were imaged using cardiovascular magnetic resonance at similar time points. Subsequently, hearts were explanted and imaged ex vivo, and samples of Hemo+, Hemo-, remote, and Sham myocardium were isolated and stained. The extent of iron deposition ([Fe]) within each sample was measured using mass spectrometry. Hemo+ infarcts showed significant T2* losses compared with the other (control) groups (P<0.001), and Perls stain confirmed localized iron deposition. Mean [Fe] of Hemo+ was nearly an order of magnitude greater than that of the control groups (P<0.001), but no significant differences were observed among the control groups. A strong linear relationship was observed between log(T2*) and -log([Fe]); R(2)=0.7 and P<0.001. The monoclonal antibody Mac387 stains, along with Perls stains, showed preferential localization of newly recruited macrophages at the site of chronic iron deposition. CONCLUSIONS: Hemorrhagic myocardial infarction can lead to iron depositions within the infarct zones, which can be a source of prolonged inflammatory burden in the chronic phase of myocardial infarction.


Assuntos
Hemorragia/diagnóstico , Ferro/metabolismo , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/diagnóstico , Miocárdio/metabolismo , Miocárdio/patologia , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Animais , Modelos Animais de Doenças , Cães , Feminino , Hemorragia/etiologia , Hemorragia/metabolismo , Hemorragia/patologia , Humanos , Modelos Lineares , Macrófagos/metabolismo , Macrófagos/patologia , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Análise Multivariada , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Valor Preditivo dos Testes , Fatores de Risco , Fatores de Tempo
15.
J Magn Reson Imaging ; 35(6): 1338-48, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22246681

RESUMO

PURPOSE: To investigate whether a statistical analysis of myocardial blood-oxygen-level-dependent (mBOLD) signal intensities can lead to the identification and quantification of the ischemic area supplied by the culprit artery. MATERIALS AND METHODS: Cardiac BOLD images were acquired in a canine model (n = 9) with controllable LCX stenosis at rest and during adenosine infusion on a 1.5T clinical scanner. Statistical distributions of myocardial pixel-intensities derived from BOLD images were used to compute an area metric (ischemic extent, IE). True myocardial perfusion was estimated from microsphere analysis. IE was compared against a standard metric (segment-intensity-response, SIR). Additional animals (n = 3) were used to investigate the feasibility of the approach for identifying ischemic territories due to LAD stenosis from mBOLD images. RESULTS: Regression analyses showed that IE and myocardial flow ratio between rest and adenosine infusion (MFR) were exponentially related (R(2) > 0.70, P < 0.001, for end-systole and end-diastole), while SIR and MFR were linearly related to end-systole (R(2) = 0.51, P < 0.04) and unrelated to end-diastole (R(2) ≈ 0, P = 0.91). Receiver-operating-characteristic analysis that IE was superior to SIR for detecting critical stenosis (MFR ≤ 2) in end-systole and end-diastole. Feasibility studies on LAD narrowing demonstrated that the proposed approach could also identify oxygenation changes in the LAD territories. CONCLUSION: The proposed evaluation of cardiac BOLD magnetic resonance imaging (MRI) offers marked improvement in sensitivity and specificity for detecting critical coronary stenosis at 1.5T compared to the mean segmental intensity approach. Patient studies are now warranted to determine its clinical utility.


Assuntos
Estenose Coronária/sangue , Estenose Coronária/diagnóstico , Imageamento por Ressonância Magnética/métodos , Isquemia Miocárdica/sangue , Isquemia Miocárdica/diagnóstico , Oxigênio/sangue , Animais , Biomarcadores/sangue , Estenose Coronária/complicações , Cães , Isquemia Miocárdica/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
16.
J Cardiovasc Magn Reson ; 12: 20, 2010 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-20356402

RESUMO

BACKGROUND: As myocardial oxygenation may serve as a marker for ischemia and microvascular dysfunction, it could be clinically useful to have a non-invasive measure of changes in myocardial oxygenation. However, the impact of induced blood flow changes on oxygenation is not well understood. We used oxygenation-sensitive CMR to assess the relations between myocardial oxygenation and coronary sinus blood oxygen saturation (SvO2) and coronary blood flow in a dog model in which hyperemia was induced by intracoronary administration of vasodilators. RESULTS: During administration of acetylcholine and adenosine, CMR signal intensity correlated linearly with simultaneously measured SvO2 (r2 = 0.74, P < 0.001). Both SvO2 and CMR signal intensity were exponentially related to coronary blood flow, with SvO2 approaching 87%. CONCLUSIONS: Myocardial oxygenation as assessed with oxygenation-sensitive CMR imaging is linearly related to SvO2 and is exponentially related to vasodilator-induced increases of blood flow. Oxygenation-sensitive CMR may be useful to assess ischemia and microvascular function in patients. Its clinical utility should be evaluated.


Assuntos
Circulação Coronária , Hiperemia/sangue , Imagem Cinética por Ressonância Magnética , Microcirculação , Miocárdio/metabolismo , Consumo de Oxigênio , Oxigênio/sangue , Acetilcolina , Adenosina , Animais , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Modelos Animais de Doenças , Cães , Gadolínio DTPA , Hiperemia/induzido quimicamente , Hiperemia/fisiopatologia , Fatores de Tempo , Vasodilatadores
17.
Mol Imaging ; 8(5): 254-63, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19796603

RESUMO

Negative contrast magnetic resonance imaging (MRI) methods using magnetic susceptibility shifting agents have become one of the most important approaches in cellular imaging research. However, visualizing and tracking labeled cells on the basis of negative contrast is often met with limited specificity and sensitivity. Here we report on a MRI method for cellular imaging that generates a new contrast with a distinct topology for identifying labeled cells that has the potential to significantly improve both the sensitivity and the specificity. Specifically, we show that low flip-angle steady-state free precession MRI can be used to generate fast three-dimensional images of tissue that can be rapidly processed to generate quantitative metrics enabling color overlays indicative of regions containing labeled cells. The technique substantially improves the ability of MRI for detecting labeled cells by overcoming the fundamental limits that currently plague negative contrast methods.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Animais , Linhagem Celular Tumoral , Ratos , Ratos Endogâmicos F344
18.
Mol Imaging ; 8(3): 148-55, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19723472

RESUMO

The objectives of this study were to investigate the feasibility of imaging green fluorescent protein (GFP)-expressing cells labeled with iron oxide nanoparticles with the fast low-angle positive contrast steady-state free precession (FLAPS) method and to compare them with the traditional negative contrast technique. The GFP-R3230Ac cell line (GFP cell) was incubated for 24 hours using 20 microg Fe/mL concentration of superparamagnetic iron oxide (SPIO) and ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. Cell samples were prepared for iron content analysis and cell function evaluation. The labeled cells were imaged using positive contrast with FLAPS imaging, and FLAPS images were compared with negative contrast T2*-weighted images. The results demonstrated that SPIO and USPIO labeling of GFP cells had no effect on cell function or GFP expression. Labeled cells were successfully imaged with both positive and negative contrast magnetic resonance imaging (MRI). The labeled cells were observed as a narrow band of signal enhancement surrounding signal voids in FLAPS images and were visible as signal voids in T2*-weighted images. Positive contrast and negative contrast imaging were both valuable for visualizing labeled GFP cells. MRI of labeled cells with GFP expression holds potential promise for monitoring the temporal and spatial migration of gene markers and cells, thereby enhancing the understanding of cell- and gene-based therapeutic strategies.


Assuntos
Compostos Férricos/química , Proteínas de Fluorescência Verde/química , Proteínas de Fluorescência Verde/genética , Imageamento por Ressonância Magnética/métodos , Magnetismo , Nanopartículas Metálicas/química , Análise de Variância , Animais , Linhagem Celular Tumoral , Sobrevivência Celular , Meios de Contraste , Compostos Férricos/metabolismo , Expressão Gênica , Proteínas de Fluorescência Verde/metabolismo , Microscopia Confocal , Ratos , Coloração e Rotulagem
19.
Magn Reson Imaging ; 27(7): 961-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19520536

RESUMO

The feasibility of imaging macrophages labeled with ultrasmall superparamagnetic iron-oxide nanoparticles (USPIO) with fast low-angle positive contrast steady-state free precession (FLAPS) was investigated through theory and in vitro experiment. Human macrophage cells were labeled with USPIO and imaged at 1.5 T. The metric "visibility," which combines magnitude and spatial extent of positive contrast, was used to evaluate the images. Negative contrast steady-state free precession (SSFP) and gradient-echo (GRE) imaging were also evaluated. Positive contrast was observed for relatively high concentrations of labeled cells for flip angles less than alpha=25 degrees . Theoretical and experimental results indicate that positive visibility (VIS(POS)) was maximized at alpha=10 degrees and 15 degrees. Low flip angle SSFP also provided negative contrast comparable to standard SSFP and GRE imaging. Results suggest that USPIO-labeled macrophages are capable of producing the conditions necessary for positive contrast with FLAPS at clinical field strength (1.5 T) and resolution (0.8x0.8x3 mm(3)).


Assuntos
Algoritmos , Dextranos , Óxido Ferroso-Férrico , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Macrófagos/citologia , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Células Cultivadas , Simulação por Computador , Meios de Contraste , Humanos , Nanopartículas de Magnetita , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos
20.
Nanomedicine ; 4(3): 201-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18567541

RESUMO

Nanoconjugates composed of titanium dioxide (TiO2) nanoparticles, DNA oligonucleotides, and a gadolinium (Gd) contrast agent were synthesized for use in magnetic resonance imaging. Transfection of cultured cancer cells with these nanoconjugates showed them to be superior to the free contrast agent of the same formulation with regard to intracellular accumulation, retention, and subcellular localization. Our results have shown that 48 hours after treatment, the concentration of Gd in nanoconjugate-treated cells was 1000-fold higher than in cells treated with contrast agent alone. Consequently, T1-weighted contrast enhancements were observed in cells treated with nanoconjugates but not in cells treated by the contrast agent alone. This type of nanoconjugate with increased retention time, Gd accumulation, and intracellular delivery may find its use in Gd neutron-capture cancer therapy.


Assuntos
Meios de Contraste/química , Gadolínio , Compostos Heterocíclicos/química , Oligonucleotídeos/química , Compostos Organometálicos/química , Titânio/química , Linhagem Celular Tumoral , Meios de Contraste/metabolismo , Dopamina/química , Compostos Heterocíclicos/metabolismo , Humanos , Imageamento por Ressonância Magnética , Nanoestruturas , Oligonucleotídeos/metabolismo , Compostos Organometálicos/metabolismo , Ácido Poliglutâmico/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA