Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Cardiovasc Med (Hagerstown) ; 21(4): 292-298, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32068573

RESUMO

INTRODUCTION: Atrial fibrillation ablation has historically been guided by fluoroscopy, with the related enhanced risk deriving from radiation. Fluoroscopy exposure may be confined to guide the transseptal puncture. Small sample size study presented a new methodology to perform a totally fluoroless atrial fibrillation ablation in the case of a patent foramen ovale (PFO). We evaluated this methodology in a large sample size of patients and a multicentre experience. METHODS AND RESULTS: Two hundred and fifty paroxysmal atrial fibrillation patients referred for first atrial fibrillation ablation with a CARTO3 electroanatomic mapping system were enrolled. In 58 out of 250 patients, a PFO allowed crossing of the interatrial septum, and a completely fluoroless ablation was performed applying the new method (Group A). In the remaining patients, a standard transseptal puncture was performed (Group B). Pulmonary vein isolation was achieved in all patients with comparable procedural and clinical outcomes at short- and long-term follow-up. CONCLUSION: The presence of a PFO may allow a completely fluoroless well tolerated and effective atrial fibrillation ablation. Probing the fossa ovalis looking for the PFO during the procedure is desirable, as it is not time-consuming and can potentially be done in every patient undergoing atrial fibrillation ablation.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Forame Oval Patente , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Forame Oval Patente/diagnóstico por imagem , Frequência Cardíaca , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Cirurgia Assistida por Computador/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
J Interv Card Electrophysiol ; 48(3): 333-341, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27943134

RESUMO

PURPOSE: Catheter ablation of the slow pathway is the most effective treatment for atrioventricular nodal reentrant tachycardia (AVNRT). Cryoenergy, compared to radiofrequency, relates to lower heart block risk but higher incidence of AVNRT recurrences. The aims of this study are to confirm the safety and efficacy of AVNRT cryoablation and to identify predictors of long-term recurrences. METHODS: Among 241 patients undergoing AVNRT cryoablation, 239 (99.2%) experienced acute effective cryoablation of the slow pathway, and no procedure-related complications were reported. RESULTS: After a follow-up of 44.9 ± 31.7 months, 28 (11.7%) patients presented AVNRT recurrences. A shorter preablation (p = 0.05) and postablation anterograde Wenckebach cycle length (p < 0.01), a shorter postablation atrioventricular node refractory period (p = 0.04), and persistence of the crossover sign (p = 0.03) were associated with higher incidence of long-term recurrences. Considering cooling dynamics, a longer time to reach temperature ≤-70 °C (p = 0.03) and a higher minimal temperature during ablation (p = 0.04) were related to recurrences. Patients without residual markers of dual AV node physiology (AH jump, single atrial echo beat, crossover) reported a lower recurrence rate (p = 0.05) compared to those without. At multivariate analysis, a longer time to -70 °C was the strongest independent predictor of long-term recurrence (OR 1.75, 95% CI 1.01-3.03, p = 0.04). CONCLUSIONS: AVNRT cryoablation is safe and effective. Long-term recurrence rate was 11.7%. An ablation approach directed to the complete elimination of dual AV node physiology, along with assessment of the tissue's cooling dynamics, holds the potential to improve long-term AVNRT cryoablation efficacy.


Assuntos
Criocirurgia/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Taquicardia por Reentrada no Nó Atrioventricular/epidemiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Criocirurgia/métodos , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Recidiva , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 38(6): 675-81, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25727697

RESUMO

BACKGROUND: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients. METHODS: We included 44 patients (mean age: 13.1 ± 3.3 years); nine of 44 presented concealed AP. An electrophysiological study with a three-dimensional EAM reconstruction was performed in every patient with a venous transfemoral direct right atrium approach or an arterial transfemoral retrograde approach to reach the mitral annulus. In two patients with left-sided AP, the ablation was performed via a patent foramen ovale. RESULTS: A total of 47 APs were present, left sided in 45% (21/47) of cases (15 lateral, one anterior, three posteroseptal, and two posterolateral) and right sided in 55% (26/47; one anterior, three anterolateral, one posterolateral, three lateral, five para-Hisian, 12 posteroseptal, and one anteroseptal). Ablation without the use of fluoroscopy was successfully performed in every patient (33 with RF and in 11 with cryoenergy). No complication occurred. At a mean follow-up of 16.0 ± 11.7 months, we observed seven recurrences, three of them successfully re-ablated without fluoroscopy. In one case cryoablation of a para-Hisian AP was ineffective in the long term. CONCLUSIONS: Three-dimensional EAM allowed a safe and effective fluoroless AP ablation procedure in a pediatric population both with RF and cryoenergy.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Adolescente , Criança , Criocirurgia , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Segurança do Paciente , Ondas de Rádio , Resultado do Tratamento
4.
Europace ; 16(12): 1800-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24843050

RESUMO

AIMS: Atrial tachycardias are common after repair of atrial septal defect (ASD). Although ablation has shown promising results in the short and mid-term follow-up, little data regarding the very long-term success exist. Our aim was to assess very long-term follow-up in patients who have undergone electroanatomic-guided radiofrequency (RF) ablation of late-onset atrial arrhythmias after ASD surgery. METHODS AND RESULTS: Forty-six consecutive patients with surgically repaired ASD were referred for atrial tachycardia ablation. Electrophysiological (EP) study and ablation procedure with the aid of an electroanatomic mapping (EAM) system were performed. Mean age was 49 ± 13 years (females 61%). The presenting arrhythmias were typical atrial flutter (48%), atypical atrial flutter (35%), and atrial tachycardia (17%). In 41% of patients, atrial fibrillation was also present. The EP study showed a right atrial macroreentrant circuit in all the patients. In 12 of 46 (26%), the circuit was localized in the cavo-tricuspid isthmus, whereas in the remaining 34 patients (74%) was atriotomy-dependent. Acute success was 100%. Clinical arrhythmia recurred in 24% of the patients. Nine patients underwent a second and two a third ablation procedure, reaching an overall efficacy of 87% (40 of 46) at a mean follow-up of 7.3 ± 3.8 years since the last procedure. With antiarrhythmic drugs the success rate increased to 96% (44 of 46). No complications occurred. CONCLUSION: In patients with surgically corrected ASD, EAM-guided RF ablation of late-onset macroreentrant atrial arrhythmias demonstrated a high success rate in a very long-term follow-up. Therefore, RF ablation could be considered early in the management of late-onset macroreentrant atrial tachycardias.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Comunicação Interatrial/cirurgia , Cirurgia Assistida por Computador/métodos , Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 36(12): 1460-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23713835

RESUMO

BACKGROUND: Anatomical considerations and risks related to x-ray exposure make atrioventricular nodal reentrant tachycardia (AVNRT) ablation in pediatric patients a concerning procedure. We aimed to evaluate the feasibility, safety, and efficacy of performing fluoroless slow-pathway cryoablation guided by the electroanatomic (EA) mapping in children and adolescents. METHODS: Twenty-one consecutive patients (mean age 13.5 ± 2.4 years) symptomatic for AVNRT were prospectively enrolled to right atrium EA mapping and electrophysiological study prior to cryoablation. Cryoablation was guided by slow-pathway potential and performed using a 4-mm-tip catheter. RESULTS: Sustained slow-fast AVNRT was inducible in all the patients with a dual AV nodal physiology in 95%. Acute success was achieved in 100% of the patients with a median of two cryo-applications. Fluoroless ablation was feasible in 19 patients, while in two subjects 50 seconds and 45 seconds of x-ray were needed due to difficult progression of the catheters along the venous system. After a mean follow-up of 25 months, AVNRT recurred in five patients. All the recurrences were successfully treated with a second procedure. In three patients, a fluoroless cryoablation with a 6-mm-tip catheter was successfully performed, while in the remaining two patients, a single pulse of 60 seconds of radiofrequency energy was applied under fluoroscopic monitoring. No complications occurred. CONCLUSIONS: Combination of EA mapping systems and cryoablation may allow to perform fluoroless slow-pathway ablation for AVNRT in children and adolescents in the majority of patients. Fluoroless slow-pathway cryoablation showed a high efficacy and safety comparable to conventional fluoroscopy guided procedures.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Criocirurgia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Criança , Criocirurgia/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
7.
Europace ; 13(7): 955-62, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21421574

RESUMO

AIMS: Atrial fibrillation (AF) ablation still requires long procedural time and high radiation exposure with its related risk for the patient and the operators. This study was designed to compare three different approaches of AF ablation to verify the hypothesis that image integration with electroanatomic mapping allows minimal use of fluoroscopy. Therefore, we evaluated the procedure and fluoroscopy times of ablation using three imaging modalities: conventional fluoroscopy, image integration electroanatomic mapping, and a new electroanatomic mapping system that provides visualization of multiple catheters. METHODS AND RESULTS: One hundred and twenty patients with symptomatic refractory AF were enrolled in the study. Patients were randomly assigned to fluoroscopy alone (Group A, 40 patients), electroanatomic integration (Cartomerge®, Group B, 40 patients), and electroanatomic integration plus catheters visualization (Carto® 3 System, Group C, 40 patients) guided procedures. The ablation procedure aimed at isolating the pulmonary veins and creating lesion lines at the left atrial roof and left isthmus. Procedure and fluoroscopy parameters were recorded in all patients. Total procedure time and skin to catheter positioning time did not significantly differ between the groups. Total fluoroscopy time was statistically different between all three groups (Group A, 18'09″±5'00″; Group B, 9'48″±3'41″; Group C, 2'28″±1'40″; P<0.001). A significant difference was noted in ablation fluoroscopy time between all groups (P<0.001), mainly due to shortened fluoroscopy time in Group B (7'34″±3'15″) and Group C (0'21″±0'31″) when compared with Group A (16'07″±5'04″). CONCLUSION: Image integration and, to a larger extent, visualization of multiple catheters allowed a minimal use of fluoroscopy in transcatheter AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Raios X/efeitos adversos , Idoso , Fibrilação Atrial/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Lesões por Radiação/prevenção & controle , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Cardiovasc Med (Hagerstown) ; 7(11): 785-92, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17060803

RESUMO

OBJECTIVE: Cryoenergy is a new valuable treatment option to perform ablation close to the atrioventricular (AV) node in the cure of supraventricular tachycardias because of its favourable properties, such as the possibility of creating reversible lesions. The aim of this study was to report our experience on the effectiveness and safety of catheter cryoablation performed in "critical areas" to treat a large cohort of patients with supraventricular arrhythmias. METHODS: One hundred and thirty-one patients suffering from supraventricular tachycardias underwent catheter cryoablation using a 7F catheter. Eighty-seven patients presented with AV nodal re-entrant tachycardia (AVNRT), 39 had accessory pathways (APs) either manifest or concealed (15 midseptal, 24 parahissian), three had ectopic right atrial tachycardia (AT), and two patients had a permanent junctional reciprocating tachycardia (PJRT). When the optimal parameters were recorded, ice mapping at -30 degrees C was performed for 80 s to validate the ablation site. If the expected result occurred, cryoablation was carried out by lowering the temperature to -75 degrees C for 4 min. RESULTS: In two patients cryoablation was not performed because of technical reasons. Cryoablation was acutely successful in 84 out of 85 patients with AVNRT, in 37 of 39 with APs and in all patients with AT and PJRT. No complications occurred in any patient. Transient AV conduction impairment occurred in seven patients with midseptal APs and in two patients with AVNRT. In particular, in these patients no late permanent AV block was observed at follow-up. At a mean follow-up of 27 +/- 12.9 months, clinical success rate was 87%. CONCLUSIONS: Cryoablation is a safe and effective technique with a high success rate in the long term. It may be particularly useful when performing ablation close to the AV node or His bundle owing to the possibility of validating the ablation site with ice mapping, which creates only a reversible lesion, mainly in the midseptal APs.


Assuntos
Ablação por Cateter/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Septos Cardíacos/cirurgia , Taquicardia Supraventricular/cirurgia , Adolescente , Adulto , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Criocirurgia/efeitos adversos , Eletrocardiografia , Feminino , Fluoroscopia , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Projetos de Pesquisa , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Paroxística/fisiopatologia , Taquicardia Paroxística/cirurgia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
9.
Ital Heart J ; 4(1): 35-43, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12690919

RESUMO

BACKGROUND: Radiofrequency catheter ablation is nowadays a widely used technique for the treatment of arrhythmias; however, due to the possible complications such as atrioventricular block when radiofrequency is delivered in the septal area, this type of energy is not optimal. In contrast, cryoenergy has several positive features; first of all, it allows for the creation of reversible lesions and hence to test the effects of the ablation while the lesion is still forming thus reducing the number of ineffective and useless lesions. In addition, it also allows for the evaluation of the acute effects on the structures adjacent to the ablation site. The aim of the present study was to analyze the effectiveness and safety of catheter cryoablation in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT). METHODS: Thirty-two patients presenting with AVNRT underwent catheter cryoablation using a 7F catheter. When the optimal parameters were recorded, "ice mapping" at -30 degrees C was performed for 80 s to validate the ablation site by means of a reversible lesion. If the expected result was achieved, the cryoablation was carried out lowering the temperature to -75 degrees C for 4 min thus creating a permanent lesion. RESULTS: Slow pathway ablation guided by a slow pathway potential was successfully performed in 31 out of the 32 patients with a mean of 2.6 +/- 1.0 cryoapplications. No complications occurred in any patients. Transient AH prolongation was observed in 2 patients in a midseptal site during the ice mapping phase of AVNRT ablation. CONCLUSIONS: Cryoablation is a safe and effective technique for AVNRT ablation. It may be useful particularly when the ablation must be performed close to the atrioventricular node or His bundle, due to the possibility of validating the site of ablation by means of ice mapping that creates only a reversible lesion.


Assuntos
Ablação por Cateter/métodos , Criocirurgia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adolescente , Adulto , Estudos de Coortes , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA