Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. j. oral sci ; 22: e230438, Jan.-Dec. 2023. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1524320

RESUMO

Most patients require orthodontic treatment to improve the esthetics of their smile. Orthodontists must consider how some parameters of mini-esthetics can influence the patient's esthetic perception. Methods: A photograph of the smile of a young female was taken and some modifications were made to the buccal corridor, gingival exposure, smile arc and midline position to assess the influence of these variables on smile attractiveness. Two hundred examiners were selected from four groups: orthodontists (O), dental students (DS), orthodontic patients (OP) and surgical-orthodontic patients (SOP). Each examiner was asked to complete the questionnaire with an approval rating from 1 to 10. Significant level was set at P ≤ 0.05. Results: Only orthodontists considered buccal corridors of 4mm and midline deviation of 1mm as non-esthetic; all other examiners considered gingival exposures ≥3 mm and midline angulation as non-esthetic. All examiners assigned higher satisfaction values to the photo with the concordant smile arc and defined as non-esthetic the covered smile and the reverse smile arc. Patients perceived as non-esthetic only midline deviations of 4mm. The surgical orthodontic patients assigned lower values to the photos and showed greater attention to evaluating the esthetics of the smile than the orthodontic patients. Conclusion: Smile arc, gingival exposure and midline angulation influence smile esthetics; the role of buccal corridors and midline deviation is dependent on the type of examiner


Assuntos
Pacientes , Percepção , Sorriso , Estudantes de Odontologia , Estética Dentária , Ortodontistas
3.
Sci Rep ; 11(1): 2843, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33531610

RESUMO

Aim of this study is the evaluation of the periodontal status of impacted canines treated by closed approach with ultrasonic surgery and orthodontic treatment compared with contralateral spontaneously erupted teeth. The periodontal conditions of the teeth adjacent to the canines (lateral incisors and first premolar) were also considered. 17 patients (9 females and 8 males; mean age: 15.2 years) with unilateral palatal impaction of maxillary canine were selected. All patients were treated by closed-flap surgery with ultrasonic instruments. Periodontal status was evaluated by assessing probing depth (PD), gingival recession and width of keratinized tissue (KT) 4.6 months after the end of the orthodontic treatment, on average. Test group was composed by impacted elements and adjacent teeth and control group by contralateral spontaneously erupted canines and adjacent teeth. Student's t-test was used to compare test and control group values of PD and width of KT. Significance threshold for Student's t-test was set at p < 0.05. The average probing depth values show no significant clinical differences between the test and control groups. Probing depths recorded at the mesiovestibular and distopalatal sides of the impacted canine were statistically significant compared to the control elements (p < 0.05). No gingival recession was detected on the treated canines. The measurement of KT did not differ significantly between the test and the control groups. In conclusion, the ultrasonic surgery for disinclusion associated with a closed approach and orthodontic traction allows the alignment of an impacted palatal canine without damaging the periodontium.


Assuntos
Dente Canino/cirurgia , Ortodontia Corretiva/efeitos adversos , Periodonto/lesões , Dente Impactado/cirurgia , Procedimentos Cirúrgicos Ultrassônicos/efeitos adversos , Adolescente , Processo Alveolar/cirurgia , Criança , Feminino , Humanos , Masculino , Maxila/cirurgia , Ortodontia Corretiva/métodos , Índice Periodontal , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Ultrassônicos/métodos , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-33291253

RESUMO

(1) Background: Ozone (O3) proved to oxidize organic and inorganic compounds, and its efficacy against bacteria, viruses and fungi plasma membranes was of interest. Ozone vehicle can be a gaseous form, ozonated water or ozonized oil. The aim of this in-vitro study was to evaluate the efficacy of ozonated olive oil against Streptococcus mutans. (2) Methods: Two different commercial mouthwashes were tested: Ialozon Blu (IB) (Gemavip, Cagliari, Italy), with ozonated olive oil, and Ialozon Rose (IR) (Gemavip, Cagliari, Italy), with ozonated olive oil, hyaluronic acid and vitamin E. All formulates were analyzed in a dilution range from 2- to 256-folds in saline solution, as to reproduce the salivary dilution. Streptococcus mutans CIP103220 strain was used for the antimicrobial susceptibility test, and the Kirby-Bauer inhibition method was performed to evaluate the Minimum Inhibitory (MIC), Minimum Bactericidal (MBC), and Minimum Biofilm Inhibitory Concentration (MBIC). (3) Results: Both formulates showed the same antimicrobial activity. MIC, MBC, and MBIC were observed for dilution factors of 1/32, 1/8 and 1/8, respectively. The mean value of inhibition zone diameter was 16.5 mm for IB, and 18 mm for IR. (4) Conclusions: The results suggested that ozonized olive oil formulates were able to inactivate Streptococcus mutans avoiding the salivary dilution effect in the oral cavity.


Assuntos
Cárie Dentária , Antissépticos Bucais , Azeite de Oliva , Streptococcus mutans , Cárie Dentária/prevenção & controle , Humanos , Itália , Testes de Sensibilidade Microbiana , Antissépticos Bucais/farmacologia
5.
J Craniofac Surg ; 26(4): e311-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26080244

RESUMO

Lateral cephalometric radiograph produces a two-dimensional image with several drawbacks. Cone beam computed tomography (CBCT) allows obtaining a three-dimensional representation of the craniofacial structures and seems to overcome the problems of superimposition and magnification, providing more precision than two-dimensional methods. The aim of the current study was to test the intraobserver and interobserver reliability of linear and angular measurements performed on two-dimensional conventional cephalometric images and CBCT-generated cephalograms, and to evaluate if there is a statistically significant difference between the 2 methods of measurements. The sample group consisted of 24 adolescents with a pretreatment digital lateral radiograph and a corresponding CBCT image. A total of 16 cephalometric landmarks were identified and 17 widely used measurements (9 angular and 8 linear) were recorded by 2 independent observers. Intraobserver and interobserver reliability were assessed by calculating Pearson correlation coefficient. Student t-test was used to compare the 2 methods. The threshold for significance was set at P ≤ 0.05.Concerning the intraobserver and interobserver reliability, data showed a statistically significant correlation between all two-dimensional and three-dimensional measurements. The linear and angular measurements of two-dimensional and three-dimensional cephalometry were not statistically different. The results of the current study showed the reliability of both conventional two-dimensional and three-dimensional cephalometry. Linear and angular measurements from CBCT were found also to be similar to conventional measurements. Considering that conventional images deliver the lowest radiation doses to patients, the use of CBCT for orthodontic purposes should be limited.


Assuntos
Cefalometria/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Adolescente , Feminino , Humanos , Masculino , Curva ROC , Reprodutibilidade dos Testes
6.
Ann Stomatol (Roma) ; 4(3-4): 259-62, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24611091

RESUMO

AIM: The manual files are still widely used for initial canal negotiation prior the use of nickel-titanium shaping instruments, to determine working length and to verify patency. A mechanical glide path can be performed using manual files with handpieces, such as M4 Handpiece (SybronEndo, USA) that allows a 30°/30° reciprocating motion. The Pathfinders (SybronEndo, USA) are hand files designed to negotiate complex canals, made from stainless steel (SS) or carbon steel (CS) alloys. The aim of this in vitro study was to compare cyclic fatigue resistance of these two different types of manual Pathfinder instruments used in a M4 reciprocating handpiece in double curved artificial canals. MATERIALS AND METHODS: Manual instruments designed for glide path (size #9 ISO .02 taper) made from different alloys were selected: Group SS -stainless steel Pathfinders (Sybron Endo) and Group CS - carbon steel Pathfinders size K2 (Sybron Endo). Ten instruments of each group were tested for resistance to cyclic fatigue with a reciprocating M4 handpiece inside an artificial S-shaped canal; the time to fracture was recorded for each file and data were statistically analyzed (ANOVA). RESULTS: Mean values (and SD) were 527 (± 89) seconds for the CS instruments and 548 (± 104) seconds for the SS files. No significant differences were observed between groups (p=0,062). CONCLUSIONS: According to the results, both carbon and stainless steel instruments presented similar fatigue resistance when used with M4 reciprocating handpiece in double curved canals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA