Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Intern Med ; 289(6): 831-839, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33615623

RESUMO

Recent evidence suggests that carpal tunnel syndrome (CTS) and brachial biceps tendon rupture (BBTR) represent red flags for ATTR cardiac amyloidosis (ATTR-CA). The prevalence of upper limb tenosynovial complications in conditions entering differential diagnosis with CA, such as HCM or Anderson-Fabry disease (AFD), and hence their predictive accuracy in this setting, still remains unresolved. OBJECTIVE: To investigate the prevalence of CTS and BBTR in a consecutive cohort of ATTR-CA patients, compared with patients with HCM or AFD and with individuals without cardiac disease history. PARTICIPANTS: Consecutive patients with a diagnosis of ATTR-CA, HCM and AFD were evaluated. A control group of consecutive patients was recruited among subjects hospitalized for noncardiac reasons and no cardiac disease history. The presence of BBTR, CTS or prior surgery related to these conditions was ascertained. RESULTS: 342 patients were prospectively enrolled, including 168 ATTR-CA (141 ATTRwt, 27 ATTRm), 81 with HCM/AFD (N = 72 and 9, respectively) and 93 controls. CTS was present in 75% ATTR-CA patients, compared with 13% and 10% of HCM/AFD and controls (P = 0.0001 for both comparisons). Bilateral CTS was present in 60% of ATTR-CA patients, while it was rare (2%) in the other groups. BBTR was present in 44% of ATTR-CA patients, 8% of controls and 1% in HCM/AFD. CONCLUSIONS: CTS and BBTR are fivefold more prevalent in ATTR-CA patients compared with cardiac patients with other hypertrophic phenotypes. Positive predictive accuracy for ATTR-CA is highest when involvement is bilateral. Upper limb assessment of patients with HCM phenotypes is a simple and effective way to raise suspicion of ATTR-CA.


Assuntos
Amiloidose , Cardiomiopatia Hipertrófica , Síndrome do Túnel Carpal , Doença de Fabry , Amiloidose/diagnóstico , Amiloidose/epidemiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/epidemiologia , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/epidemiologia , Doença de Fabry/diagnóstico , Doença de Fabry/epidemiologia , Humanos , Fenótipo
2.
Artigo em Inglês | MEDLINE | ID: mdl-32336975

RESUMO

BACKGROUND: Mepolizumab (MEP) is the first anti Interleukin (IL)-5 add-on therapy approved for the treatment of severe refractory eosinophilic asthma. CASE PRESENTATION: We describe here the case of a 49 years-old woman with Aspirin-exacerbated respiratory disease (AERD), chronic rhinosinusitis, nasal polyposis and eosinophilic gastroenteritis successfully treated with MEP. Several laboratory and clinical items improved during therapy; moreover MEP showed to be useful as steroid sparing agent. CONCLUSIONS: This case supports that the use of mepolizumab can be effective also in other eosinophilic conditions different from asthma and this opens to new therapeutic perspectives.

3.
Scand J Rheumatol ; 47(5): 351-359, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29542372

RESUMO

OBJECTIVES: To define baseline clinical and immunological characteristics [anti-citrullinated peptide antibodies (ACPAs), immunoglobulin M (IgM)- and IgA-rheumatoid factor (RF), and interleukin-6 (IL-6) levels] involved in determining baseline erosiveness, outcome, and radiographic progression among seropositive and seronegative early rheumatoid arthritis (ERA) patients. METHOD: The 408 ERA patients enrolled in the study were monitored every 3 months according to the treat-to-target strategy. At baseline and after 12 months, hand and foot radiographs were evaluated using the Sharp/van der Heijde erosion score. RESULTS: At diagnosis, seronegative patients were older and had higher Disease Activity Scores (DASs) than seropositive patients. A higher risk of erosiveness at baseline was conferred by IgA-RF positivity and IL-6 plasma levels ≥7.6 pg/mL, particularly when simultaneously present. In multivariate analysis, disease duration and IL-6 plasma levels ≥7.6 pg/mL arose as independent variables associated with presence of erosions at onset. Radiographic progression at 1 year follow-up, which occurred in 11.1% of ERA patients, was predicted by ACPA positivity, together with higher age at diagnosis. Despite similar percentages of good European League Against Rheumatism response, DAS and Boolean remission being observed over time among seropositive and seronegative patients and between erosive and non-erosive subjects, ERA patients who were erosive at onset, IgA-RF seropositive, and simultaneously having high baseline IL-6 plasma levels (≥7.6 pg/mL) were treated to a greater extent with tumour necrosis factor blockers after 12 months. CONCLUSION: IgA-RF positivity and IL-6 plasma levels are crucial for baseline erosiveness, while ACPA positivity represents the strongest risk factor for developing radiographic progression in ERA.


Assuntos
Anticorpos Antiproteína Citrulinada/sangue , Artrite Reumatoide/sangue , Interleucina-6/sangue , Fator Reumatoide/sangue , Adulto , Idoso , Antirreumáticos/uso terapêutico , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/patologia , Biomarcadores/sangue , Progressão da Doença , Feminino , Seguimentos , Humanos , Imunoglobulina A/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Curva ROC , Índice de Gravidade de Doença
4.
Artigo em Inglês | MEDLINE | ID: mdl-28295762

RESUMO

The role of spirituality on the psychological health was mostly investigated through studies conducted in terminally ill patients. However, there are not studies investigating the role of religious and spiritual beliefs on psychological state and on burden dimensions in caregivers. The purpose of this study was to investigate the association between spirituality, burden, and psychological state in caregivers of terminally ill cancer patients. Two hundred caregivers of terminally ill patients with cancer were interviewed using Prolonged Grief Disorder 12 (PG-12), Hamilton Anxiety Rating Scale (HAM-A), Hamilton Depression Scale (HAM-D), Caregiver Burden Inventory (CBI) and System of Belief Inventory (SBI-15R). The caregiver burden was positively correlated with anxiety, depression and PG-12 scores. The intrinsic spirituality was a significant predictor of the time-dependence burden (positively associated); and of the emotional burden (negatively associated). In caregivers of terminally ill cancer patients, higher levels of intrinsic spirituality predicted a higher amount of time devote to caregiving, and also protected against the emotional distress linked to providing assistance.


Assuntos
Cuidadores/psicologia , Efeitos Psicossociais da Doença , Neoplasias/psicologia , Espiritualidade , Assistência Terminal/psicologia , Adaptação Psicológica , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doente Terminal
5.
Int J Cardiol ; 179: 539-45, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25466563

RESUMO

OBJECTIVES: We sought to investigate the role of balloon size during pre-implantation valvuloplasty in predicting AR and optimal Medtronic CoreValve (MCS) implantation depth. BACKGROUND: Paravalvular aortic regurgitation (AR) is common following MCS implantation. A number of anatomical and procedural variables have been proposed as determinants of AR including degree of valve calcification, valve undersizing and implantation depth. METHODS: We conducted a multicenter retrospective analysis of 282 patients who had undergone MCS implantation with prior cardiac CT annular sizing between 2007 and 2011. Native valve minimum (Dmin), maximum (Dmax) and arithmetic mean (Dmean) annulus diameters as well as agatston calcium score were recorded. Nominal and achieved balloon size was also recorded. AR was assessed using contrast angiography at the end of each procedure. Implant depth was measured as the mean distance from the nadir of the non- and left coronary sinuses to the distal valve frame angiographically. RESULTS: 29 mm and 26 mm MCS were implanted in 60% and 39% of patients respectively. The majority of patients (N=165) developed AR <2 following MCS implantation. AR ≥3 was observed in 16% of the study population. High agatston calcium score and Dmean were found to be independent predictors of AR ≥3 in multivariate analysis (P<0.0001). Nominal balloon diameter and the number of balloon inflations did not influence AR. However a small achieved balloon diameter-to-Dmean ratio (≤0.85) showed modest correlation with AR ≥3 (P=0.04). This observation was made irrespective of the degree of valve calcification. A small MCS size-to-Dmean ratio is also associated with AR ≥3 (P=0.001). A mean implantation depth of ≥8+2mm was also associated with AR ≥3. Implantation depth of ≥12 mm was associated with small MCS diameter-to-Dmean ratio and increased 30-day mortality. CONCLUSION: CT measured aortic annulus diameter and agatston calcium score remain important predictors of significant AR. Other procedural predictors include valve undersizing and low implantation depth. A small achieved balloon diameter-to-Dmean ratio might also predict AR ≥3. Our findings confirm that a small achieved balloon size during pre-implantation valvuloplasty predicts moderate-severe AR in addition to previously documented factors.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Meios de Contraste , Angiografia Coronária , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
6.
Herz ; 36(3): 198-212, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21541738

RESUMO

Despite major improvements in stent technology (i.e., drug-eluting stents, DES), treatment of coronary bifurcations is an ever occurring problem of the interventional cardiology. While stenting the main branch with provisional side branch stenting seems to be the prevailing approach, in the era of DES various two-stent techniques emerged (crush) or were re-introduced (V or simultaneous kissing stents, crush, T, culottes, etc.) to allow stenting in the side branch when needed. New techniques in imaging like optical coherence tomography help in better understanding bifurcation anatomy and, thus, have the potential to help us better treat this challenging subset of lesions. In addition, new dedicated bifurcation stents have been proposed in an attempt to overcome limitations associated with current approaches, and they showed promising results in early studies; however, the safety and the efficacy of these devices remain to be seen in the ongoing and upcoming trials. This review focuses on the current approaches and the development of new techniques employed for the treatment of bifurcation disease.


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Stents Farmacológicos/tendências , Implantação de Prótese/tendências , Cirurgia Assistida por Computador/tendências , Previsões , Humanos
7.
Minerva Cardioangiol ; 52(5): 365-78, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15514572

RESUMO

Percutaneous treatment of coronary bifurcation lesions remained challenging in the stent era, with restenosis rates greater than 30% and no advantage from the routine use of kissing stents. Drug eluting stents (DES) have dramatically reduced the restenosis rates (RR) in the main vessel, but with conventional T-stenting double digits figures are still reported for the side-branch because of poor ostial coverage. The techniques of kissing stenting able to provide full lesion coverage (Culotte, V-stenting, Crush) have the potential to improve these results but the development of dedicated DES is probably needed to obtain consistently high procedural and long-term success.


Assuntos
Angioplastia Coronária com Balão , Estenose Coronária/terapia , Stents , Antineoplásicos Fitogênicos/administração & dosagem , Reestenose Coronária/prevenção & controle , Estenose Coronária/classificação , Quimioterapia Combinada , Desenho de Equipamento , Humanos , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Sirolimo/administração & dosagem , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 54(4): 473-81, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11747183

RESUMO

The aim of the study was to evaluate the feasibility, safety, and efficacy of cutting balloon angioplasty in treatment of angiographically moderate and severe calcified coronary lesions. Thirty-seven calcified coronary lesions (29 patients) detected by angiography were dilated with cutting balloon. Predilatation with plain balloon was performed in 27 (73.0%) lesions and stent was implanted in 23 (62.2%) lesions following cutting balloon. Acute gain following cutting balloon in predilated lesions was compared to the acute gain following plain balloon predilatation. For predilated lesions, acute gain after cutting balloon was significantly greater compared with plain balloon predilatation (1.51 +/- 0.49 vs. 0.77 +/- 0.42; P = 0.01). This result was achieved with larger size and lower pressure of cutting balloon compared with plain balloon (3.28 +/- 0.46 vs. 2.94 +/- 0.55, P = 0.01; 10.38 +/- 1.64 vs. 13.19 +/- 3.63, P = 0.001, respectively). The final gain following cutting balloon dilatation was significantly higher than the expected gain obtained by using a plain balloon of the same size (1.51 +/- 0.49 vs. 0.93 +/- 0.48; P < 0.0001), which was inflated at significantly higher pressure compared with cutting balloon. When we compared acute gain following cutting balloon in lesions with and without predilatation, we found no significant difference (P = 0.31). Angiographic success was achieved in 36 (97.3%) lesions and procedural success in 33 (89.1%) lesions. In-hospital major adverse cardiac event (MACE) occurred in three (10.3%) patients. Follow-up MACE was reported from three (10.3%) patients. In conclusion, cutting balloon angioplasty is feasible and safe in treatment of angiographically moderate and severe calcified lesions. Dilating efficiency of cutting balloon seems to be greater compared with a plain balloon of the same size, which was inflated at significantly higher pressure compared with cutting balloon. These results can be achieved with low in-hospital MACE and are associated with a good long-term outcome.


Assuntos
Angioplastia Coronária com Balão/métodos , Calcinose/complicações , Calcinose/terapia , Estenose Coronária/complicações , Estenose Coronária/terapia , Idoso , Implante de Prótese Vascular/instrumentação , Angiografia Coronária , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança , Índice de Gravidade de Doença , Stents , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 54(2): 216-8, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11590688

RESUMO

Late total occlusion (LTO) after simultaneous coronary stenting and brachytherapy has been described in recent randomized trials. We report a case of LTO presenting with an acute clinical event 15 months after the index procedure, suggesting that the risk is not confined to the first 6-month to 1-year period.


Assuntos
Braquiterapia/efeitos adversos , Doença das Coronárias/radioterapia , Trombose Coronária/etiologia , Implante de Prótese Vascular/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo
12.
Circulation ; 104(12): 1343-9, 2001 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-11560848

RESUMO

BACKGROUND: Observational studies in selected patients have shown remarkably low restenosis rates after ultrasound-guided stent implantation. However, it is unknown whether this implantation strategy improves long-term angiographic and clinical outcome in routine clinical practice. Methods and Results-- A total of 550 patients with a symptomatic coronary lesion or silent ischemia were randomly assigned to either ultrasound-guided or angiography-guided implantation of

Assuntos
Implante de Prótese Vascular/métodos , Angiografia Coronária , Doença das Coronárias/cirurgia , Oclusão de Enxerto Vascular/prevenção & controle , Ultrassonografia , Implante de Prótese Vascular/instrumentação , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
Ital Heart J Suppl ; 2(6): 579-92, 2001 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-11460831

RESUMO

Coronary angiography remains the standard technique for the assessment and therapy of coronary artery disease. Recently, intravascular ultrasound (IVUS) has emerged as a new adjunctive invasive tool which allows the acquisition of direct images of the atherosclerotic plaque in the cardiac catheterization laboratory; however it cannot be considered as an alternative to angiography. The aim of this article was to describe the indications, technique, and interpretation of IVUS imaging and its diagnostic and therapeutic applications, to review the pertaining literature and report the experience from our catheterization lab group. Ultrasound provides a unique method to study the regression or progression of atherosclerotic lesions in vivo. Lipid-laden lesions appear hypoechoic, fibromuscular lesions generate low-intensity or "soft echos" while the fibrous and calcified tissue impedes ultrasound penetration, obscuring the underlying vessel wall (acoustic shadowing). IVUS has been used to evaluate arterial remodeling: positive remodeling is the increase in arterial size to compensate for plaque accumulation and represents a compensatory mechanism to preserve lumen size; negative remodeling is vessel shrinkage and has been implicated in restenosis after balloon angioplasty. Positive remodeling seems to be significantly more frequent in myocardial infarction and unstable angina, negative remodeling occurs more often in stable coronary syndromes and is the main mechanism of restenosis after balloon angioplasty. In ostial and bifurcation lesion, the stenosis may be obscured by overlapping contrast-filled structures. Intermediate stenoses are particularly problematic in patients whose symptomatic status is difficult to assess. In these ambiguous situations, ultrasound provides a tomographic perspective, independent of the radiographic projection, which often allows precise lesion quantification. IVUS has emerged as the optimal method for the detection of diffuse post-transplant vasculopathy. Rapidly progressive intimal thickening (> 0.5 mm increase) in the first year after transplantation has major negative prognostic significance. The safety of IVUS is well documented, with studies reporting complication rates varying from 1 to 3%; the complications most frequently reported is transient spasm. Ultrasound allows us to evaluate plaque morphology, plaque eccentricity and lesion length, often helping in procedural decision-making. IVUS demonstrates plaque fracture and arterial wall dissection more often than angiography. Coronary angiograms frequently underestimate disease burden, whereas IVUS identifies residual plaque burden and minimal lumen diameter as the most powerful predictor of clinical outcome (restenosis). Several IVUS studies of directional atherectomy have addressed the issue of more aggressive plaque removal possibly resulting in decreased angiographic restenosis rate. IVUS imaging has played a pivotal role in the optimization of stent therapy. The concept of high-pressure stent implantation disseminated quickly, and larger trials demonstrated the safety of stent implantation using high pressures. IVUS has shown that in-stent restenosis is determined by the degree of intimal hyperplasia within the stent or in the stent border. In conclusion, the use of IVUS in the world is slowly increasing. Ultrasound commonly detects occult disease in patients with coronary artery disease. However, no short- or long-term studies have determined whether disease detected exclusively by ultrasound portends a worse prognosis as compared with "true normal" angiography.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Angioplastia Coronária com Balão , Aterectomia , Braquiterapia , Humanos , Cuidados Intraoperatórios , Revascularização Miocárdica/métodos , Stents , Ultrassonografia/métodos
15.
J Am Coll Cardiol ; 37(8): 2074-9, 2001 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11419890

RESUMO

OBJECTIVES: The purpose of this study was to assess the efficacy of emergency stent implantation for the treatment of perioperative stroke after carotid endarterectomy (CEA). BACKGROUND: Carotid endarterectomy has been proven safe and effective in reducing the risk of stroke in symptomatic and asymptomatic patients with >60% carotid artery stenosis. However, perioperative stroke has been reported in 1.5% to 9% of CEA cases. The management of such a complication is challenging. Recently, percutaneous transluminal carotid angioplasty with stent deployment has emerged as a valuable and alternative strategy for the treatment of carotid artery disease. METHODS: Between April 1998 and February 2000, 18 of the 995 patients (1.8%) who had CEA in our institution experienced perioperative major or minor neurological complications. Of these, 13 patients underwent emergency carotid angiogram and eventual stent implantation, whereas the remaining five had surgery re-exploration. RESULTS: Carotid angiogram was performed within 20+/-10 min and revealed vessel flow-limiting dissection (five cases) or thrombosis (eight cases). Percutaneous transluminal carotid angioplasty with direct stenting (self-expandable stent) was performed in all 13 cases. Angiographic success was 100%. Complete remission of neurological symptoms occurred in 11 of the 13 patients treated by stent implantation and in one of the five patients treated by surgical re-exploration (p = 0.024). CONCLUSIONS: Stent implantation seems to be a safe and effective strategy in the treatment of perioperative stroke complicating CEA, especially when carotid dissection represents the main anatomic problem.


Assuntos
Endarterectomia das Carótidas/efeitos adversos , Stents , Acidente Vascular Cerebral/etiologia , Idoso , Serviços Médicos de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
Ital Heart J ; 2(1): 21-4, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11214697

RESUMO

Coronary artery bypass surgery and angioplasty provide symptomatic relief in patients with ischemic heart disease, but despite advancement in technique and devices, these methods are not applicable to a subset of patients with angina refractory to medical treatment. Bypass surgery might not be feasible because of lack of suitable conduits, diffuse coronary disease or poor distal run-off, and coronary angioplasty is sometimes not applicable due to chronic total occlusion, diffuse disease or extreme tortuosity. We have previously reviewed the available experience with laser-induced direct myocardial revascularization, one of the new potential treatment modalities for this patient subset. One of the potential mechanisms of action for laser treatment is the induction of neoangiogenesis. In the second part of our article we review the available experience with the induction of myocardial angiogenesis using different growth factors or the genes encoding for them.


Assuntos
Doença das Coronárias/tratamento farmacológico , Fatores de Crescimento Endotelial/uso terapêutico , Neovascularização Fisiológica/fisiologia , Doença das Coronárias/fisiopatologia , Modelos Animais de Doenças , Fatores de Crescimento Endotelial/fisiologia , Fatores de Crescimento de Fibroblastos/fisiologia , Terapia Genética/métodos , Humanos , Linfocinas/uso terapêutico , Fator A de Crescimento do Endotélio Vascular , Fatores de Crescimento do Endotélio Vascular
17.
Ital Heart J ; 1(11): 739-48, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11110516

RESUMO

BACKGROUND: Coronary stent has become an accepted treatment modality for selected indications. However, the literature shows diverse results when indications for coronary stenting are different from those tested in large randomized trials. The purpose of this study was to determine immediate and follow-up clinical and angiographic results in patients treated with coronary stenting for indications not specifically tested in large randomized trials. METHODS: Coronary stents were implanted in a total of 2060 lesions (1757 patients) in seven groups with expanded indications: left main coronary lesions, calcified lesions, small vessels (< 3 mm in size), small vessels with diffuse disease, large vessels with diffuse disease, and bifurcation lesions treated with stents in both branches or with one stent implanted only in the major branch. Stents were implanted using high balloon pressure for final inflation and in most cases with intravascular ultrasound. Clinical follow-up was achieved in 96% of patients at a mean time of 12+/-7 months. RESULTS: Primary success (range 89-96%) and acute complications (range 5.7-13%) were comparable in all groups. At follow-up, the mortality rate was highest in the group of left main stenting (12.5%) but 20% of these patients had coronary stenting on non-elective basis. The restenosis rates ranged between 16-43%. The restenosis rate was highest in the group of bifurcation lesions with stent implantation in both vessels leading to a major adverse cardiac event (MACE) rate of 62% in this group. However, the survival rate at 1 and 2 years in the overall study group was 97 and 96%, and the event free survival was 76 and 74%, respectively. The procedure-related predictors of MACE were: final intravascular ultrasound result, use of stents with non-slotted tube morphology, final stent percent stenosis, and vessel size. CONCLUSIONS: Coronary stenting beyond standard indications is feasible, with acceptable primary success and complication rates. However, the overall MACE rates were relatively high (34-62%), in particular for the indication of bifurcation lesions with stents implanted in both vessels.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Stents , Fatores Etários , Idoso , Análise de Variância , Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Interpretação Estatística de Dados , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Fatores de Tempo
18.
J Invasive Cardiol ; 12(10): 505-12, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11022209

RESUMO

PURPOSE: The aim of this study was to evaluate the immediate and long-term outcomes following percutaneous treatment of an unselected series of saphenous vein graft (SVG) lesions. METHODS AND RESULTS: Consecutive interventions on 129 saphenous vein graft lesions in 101 patients were reviewed. Stents were implanted in 114 lesions (88%), which included the use of polytetrafluoroethylene-covered stents in 22 lesions (17%) and abciximab in 20 patients (20%). Angiographic success was achieved in 125 lesions (97%). In-hospital major adverse cardiac events (MACE) occurred in 11 patients (11%), with myocardial infarction being the most frequent event. Treatment of degenerated SVG lesions and SVG lesions with larger reference diameters correlated with the incidence of in-hospital MACE [odds ratio (OR) = 7.69 and 2.65, respectively; 95% confidence interval (CI) = 1.80Eth 32.8 and 0.99Eth 7.10, respectively)]. Clinical follow-up was achieved in all patients at 25 +/- 21 months. Successful revascularization to all three distributions of the major coronary arteries negatively correlated [relative risk (RR) = 0.43; 95% CI = 0.20Eth 0.92)], while treatment of a degenerated SVG positively correlated (RR = 1.92; 95% CI = 1.05Eth 3.51) with the occurrence of follow-up MACE. A final effective blood supply to the anterior wall and a higher left ventricular ejection fraction was found to negatively correlate with the occurrence of follow-up death (RR = 0. 20 and 0.61, respectively; 95% CI = 0.06Eth 0.60 and 0.41Eth 0.90, respectively). CONCLUSION: Treatment of SVG lesions continues to be associated with a high incidence of myocardial infarction, particularly in cases of degenerated SVG lesions. An effective blood supply to the anterior wall and a higher left ventricular ejection fraction were protective for the occurrence of death during the follow-up period.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Veia Safena/transplante , Stents , Idoso , Idoso de 80 Anos ou mais , Intervalos de Confiança , Angiografia Coronária , Ponte de Artéria Coronária/métodos , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/mortalidade , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Probabilidade , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 51(1): 78-82, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10973025

RESUMO

The increase in the use of the left internal mammary artery (LIMA) as graft of choice to the left anterior descending coronary artery for conventional and minimally invasive coronary artery bypass surgery has led to an increased incidence of LIMA pathologic lesions early after surgery. The lesion, commonly located in the body of the LIMA graft, is usually caused by mechanical injury during harvesting of the vessel. In this context, percutaneous intervention with stent implantation can be complicated by vessel rupture, which usually requires emergency surgical repair. We describe two cases of stent implantation in newly placed LIMA grafts complicated by vessel rupture, which were successfully repaired using polytetrafluoroethylene-covered stents.


Assuntos
Artéria Torácica Interna/lesões , Artéria Torácica Interna/transplante , Politetrafluoretileno , Stents , Ferimentos Penetrantes/terapia , Idoso , Angioplastia com Balão , Ponte de Artéria Coronária/métodos , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Suturas/efeitos adversos , Coleta de Tecidos e Órgãos/efeitos adversos , Coleta de Tecidos e Órgãos/métodos , Ferimentos Penetrantes/etiologia
20.
Ital Heart J ; 1(7): 480-6, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10933331

RESUMO

BACKGROUND: Coronary artery stenting reduces the restenosis rate compared to coronary angioplasty alone. With the increased number of procedures completed with stent placement there has been a parallel increase in the number of procedures performed in patients with multivessel disease and therefore a rise in the number of patients receiving multiple stents. The clinical outcome and the predictors of the outcome of patients receiving multiple stents are not known. METHODS: To evaluate the clinical outcome of patients with multivessel coronary artery disease undergoing multiple stenting we studied 133 consecutive patients who had received > 1 stent in at least two vessels. A total of 375 coronary stents (2.8 stent per patient) were implanted in elective procedure situations. Clinical follow-up was complete in 100%. RESULTS: During follow-up 2 patients (1.5%) died (1 cardiac death), 4 patients (3%) had acute myocardial infarction, 96 patients (72.1%) remained angina-free, and 31 patients (23.3 %) had recurrence of angina. Repeat revascularization procedure was performed in 45 patients (33.8%); 43 patients (32.3%) underwent coronary angioplasty; 2 patients (1.5%) underwent coronary artery bypass grafting. The female gender and the presence of diabetes were significant (p < 0.05) predictors for coronary angioplasty or coronary artery bypass grafting procedures during follow-up. Recurrence of angina was also significantly (p < 0.05) associated with unstable angina at the time of the first procedure as well as diabetes and the female gender. Diabetes, the female gender and unstable angina were highly predictive factors of major adverse cardiac events during follow-up. CONCLUSIONS: Multiple vessel stenting in patients with multivessel coronary artery disease is associated with an acceptable immediate and long-term clinical outcome and could be considered as an alternative therapeutic option in these patients. Predictors of an adverse long-term outcome are the female gender and the presence of diabetes mellitus.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Stents , Angiografia Coronária , Ponte de Artéria Coronária , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários , Complicações do Diabetes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA