Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Circ Cardiovasc Interv ; 17(5): e014054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38696284

RESUMO

BACKGROUND: XC001 is a novel adenoviral-5 vector designed to express multiple isoforms of VEGF (vascular endothelial growth factor) and more safely and potently induce angiogenesis. The EXACT trial (Epicardial Delivery of XC001 Gene Therapy for Refractory Angina Coronary Treatment) assessed the safety and preliminary efficacy of XC001 in patients with no option refractory angina. METHODS: In this single-arm, multicenter, open-label trial, 32 patients with no option refractory angina received a single treatment of XC001 (1×1011 viral particles) via transepicardial delivery. RESULTS: There were no severe adverse events attributed to the study drug. Twenty expected severe adverse events in 13 patients were related to the surgical procedure. Total exercise duration increased from a mean±SD of 359.9±105.55 seconds at baseline to 448.2±168.45 (3 months), 449.2±175.9 (6 months), and 477.6±174.7 (12 months; +88.3 [95% CI, 37.1-139.5], +84.5 [95% CI, 34.1-134.9], and +115.5 [95% CI, 59.1-171.9]). Total myocardial perfusion deficit on positron emission tomography imaging decreased by 10.2% (95% CI, -3.1% to 23.5%), 14.3% (95% CI, 2.8%-25.7%), and 10.2% (95% CI, -0.8% to -21.2%). Angina frequency decreased from a mean±SD 12.2±12.5 episodes to 5.2±7.2 (3 months), 5.1±7.8 (6 months), and 2.7±4.8 (12 months), with an average decrease of 7.7 (95% CI, 4.1-11.3), 6.6 (95% CI, 3.5-9.7), and 8.8 (4.6-13.0) episodes at 3, 6, and 12 months. Angina class improved in 81% of participants at 6 months. CONCLUSIONS: XC001 administered via transepicardial delivery is safe and generally well tolerated. Exploratory improvements in total exercise duration, ischemic burden, and subjective measures support a biologic effect sustained to 12 months, warranting further investigation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04125732.


Assuntos
Angina Pectoris , Terapia Genética , Vetores Genéticos , Neovascularização Fisiológica , Fator A de Crescimento do Endotélio Vascular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angina Pectoris/terapia , Angina Pectoris/fisiopatologia , Terapia Genética/efeitos adversos , Idoso , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/genética , Fatores de Tempo , Tolerância ao Exercício , Adenoviridae/genética , Recuperação de Função Fisiológica
2.
Circ Cardiovasc Interv ; 16(8): e012997, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37503661

RESUMO

BACKGROUND: New therapies are needed for patients with refractory angina. Encoberminogene rezmadenovec (XC001), a novel adenoviral-5 vector coding for all 3 major isoforms of VEGF (vascular endothelial growth factor), demonstrated enhanced local angiogenesis in preclinical models; however, the maximal tolerated dose and safety of direct epicardial administration remain unknown. METHODS: In the phase 1 portion of this multicenter, open-label, single-arm, dose-escalation study, patients with refractory angina received increasing doses of encoberminogene rezmadenovec (1×109, 1×1010, 4×1010, and 1×1011 viral particles) to evaluate its safety, tolerability, and preliminary efficacy. Patients had class II to IV angina on maximally tolerated medical therapy, demonstrable ischemia on stress testing, and were angina-limited on exercise treadmill testing. Patients underwent minithoracotomy with epicardial delivery of 15 0.1-mL injections of encoberminogene rezmadenovec. The primary outcome was safety via adverse event monitoring over 6 months. Efficacy assessments included difference from baseline to months 3, 6 (primary), and 12 in total exercise duration, myocardial perfusion deficit using positron emission tomography, angina class, angina frequency, and quality of life. RESULTS: From June 2, 2020 to June 25, 2021, 12 patients were enrolled into 4 dosing cohorts with 1×1011 viral particle as the highest planned dose. Seventeen serious adverse events were reported in 7 patients; none were related to study drug. Six serious adverse events in 4 patients were related to the thoracotomy, 3 non-serious adverse events were possibly related to study drug. The 2 lowest doses did not demonstrate improvements in total exercise duration, myocardial perfusion deficit, or angina frequency; however, there appeared to be improvements in all parameters with the 2 higher doses. CONCLUSIONS: Epicardial delivery of encoberminogene rezmadenovec via minithoracotomy is feasible, and up to 1×1011 viral particle appears well tolerated. A dose response was observed across 4 dosing cohorts in total exercise duration, myocardial perfusion deficit, and angina class. The highest dose (1×1011 viral particle) was carried forward into phase 2. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04125732.


Assuntos
Qualidade de Vida , Fator A de Crescimento do Endotélio Vascular , Humanos , Resultado do Tratamento , Angina Pectoris/terapia , Teste de Esforço
3.
J Nucl Cardiol ; 30(3): 1075-1087, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36266526

RESUMO

BACKGROUND: Somatostatin receptor is expressed in sarcoid granulomas, and preliminary clinical studies have shown that myocardial sarcoidosis can be identified on somatostatin receptor-targeted PET. We examined the potential clinical use of 68Ga-DOTATATE PET/CT for diagnosis and response assessment in cardiac sarcoidosis compared to 18F-FDG PET/CT. METHODS: Eleven cardiac sarcoidosis patients with 18F-FDG PET/CT were prospectively enrolled for cardiac 68Ga-DOTATATE PET/CT. The two PET/CT studies were interpreted independently and were compared for patient-level and segment-level concordance, as well as for the degree of radiotracer uptake. Follow-up 68Ga-DOTATATE PET/CT was performed in eight patients. RESULTS: Patient-level concordance was 91%: ten patients had multifocal DOTATATE uptake (active cardiac sarcoidosis) and one patient showed diffuse DOTATATE uptake. Segment-level agreement was 77.1% (Kappa 0.53 ± 0.07). The SUVmax-to-blood pool ratio was lower on 68Ga-DOTATATE PET/CT (3.2 ± 0.6 vs. 4.9 ± 1.5, P = 0.006 on paired t test). Follow-up 68Ga-DOTATATE PET/CT showed one case of complete response and one case of partial response, while 18F-FDG PET/CT showed four cases of response, including three with complete response. CONCLUSION: Compared to 18F-FDG PET/CT, 68Ga-DOTATATE PET/CT can identify active cardiac sarcoidosis with high patient-level concordance, but with moderate segment-level concordance, low signal-to-background ratio, and underestimation of treatment response.


Assuntos
Compostos Organometálicos , Sarcoidose , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Radioisótopos de Gálio , Receptores de Somatostatina
4.
J Nucl Cardiol ; 28(4): 1395-1408, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-31407235

RESUMO

INTRODUCTION: The prevalence of defects and effective radiation dose from various myocardial perfusion imaging (MPI) strategies in congenital heart disease (CHD) is unknown. METHODS: We studied 75 subjects with complex CHD (ages 5 to 80 years) referred for MPI between 2002 and 2015. A rest and exercise or pharmacologic stress MPI was performed using 99mTechnetium sestamibi, 82rubidium or 13N-ammonia, and Sodium iodide SPECT (single-photon emission computed tomography), SPECT/CT or Cadmium zinc telluride (CZT) SPECT or PET (positron emission tomography)/CT scanners. Deidentified images were interpreted semi-quantitatively in three batches: stress only MPI, stress/rest MPI, and stress/rest MPI with taking into account a history of ventricular septal defect repair. Effective radiation dose was estimated for stress/rest MPI and predicted for 1-day stress-first (normal stress scans), and for 2-day stress/rest MPI (abnormal stress scans). RESULTS: The median age was 18.6 years. The most common type of CHD was transposition of the great arteries (63%). Rest/stress MPI was abnormal in 43% of subjects and 25% of the abnormal scans demonstrated reversible defects. Of the subjects with abnormal MPI, 33% had significant underlying anatomic coronary artery obstruction. Estimated mean effective radiation dose ranged from 2.1 ± 0.6 mSv for 13N-ammonia PET/CT to 12.5 ± 0.9 mSv for SPECT/CT. Predicted effective radiation dose was significantly lower for stress-first MPI and for 2-day stress/rest protocols. CONCLUSIONS: Due to the relatively high prevalence of abnormal stress MPI, tailored protocols with a stress-first MPI as well as the use of 2-day protocols and advanced imaging technologies including CZT SPECT, novel image reconstruction software, and PET MPI could substantially reduce radiation dose in complex CHD.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Doses de Radiação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos de Coortes , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Artigo em Inglês | MEDLINE | ID: mdl-28576787
6.
J Nucl Cardiol ; 23(4): 657-67, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27033352

RESUMO

BACKGROUND: Recent technological advances in myocardial perfusion imaging may warrant the use of lower injected activity. We evaluated whether quantitative measures of stress myocardial perfusion defects using Tc-99m sestamibi and low-energy high-resolution (LEHR) collimators are equivalent to lower dose SPECT-CT with cardiac multifocal collimators and software (IQ·SPECT). METHODS: 93 patients underwent one-day rest-stress gated SPECT-CT. Following conventional rest imaging, 925-1100 MBq (25-30 mCi) of Tc-99m sestamibi was injected during stress testing. Stress SPECT-CT images were acquired two ways: with LEHR (13 minutes) and IQ·SPECT (7 minutes). Low-dose IQ·SPECT stress was simulated by subsampling the full-dose data to half-, quarter-, and eighth-count levels. Abnormalities were quantified using the total perfusion deficit (TPD) score and dose-specific databases. RESULTS: The mean ± SD of the differences between LEHR and IQ·SPECT TPD scores were -1.01 ± 5.36%, -0.10 ± 5.81%, 1.78 ± 4.81%, and 1.75 ± 6.05% at full, half, quarter, and eighth doses, respectively. Differences were statistically significant for quarter and eighth doses. Correlation between LEHR and IQ·SPECT was excellent at all doses (R ≥ 0.93). Bland-Altman plots demonstrated minimal bias. CONCLUSIONS: With IQ·SPECT, quantitative stress SPECT-CT imaging is possible with half of the standard injected activity in half the time.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Teste de Esforço/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/análise , Proteção Radiológica/instrumentação , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tecnécio Tc 99m Sestamibi , Fatores de Tempo
7.
AJR Am J Roentgenol ; 204(1): W27-36, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539270

RESUMO

OBJECTIVE. The purpose of this study was to comprehensively study estimated radiation doses for subjects included in the main analysis of the Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography (CORE320) study ( ClinicalTrials.gov identifier NCT00934037), a clinical trial comparing combined CT angiography (CTA) and perfusion CT with the reference standard catheter angiography plus myocardial perfusion SPECT. SUBJECTS AND METHODS. Prospectively acquired data on 381 CORE320 subjects were analyzed in four groups of testing related to radiation exposure. Radiation dose estimates were compared between modalities for combined CTA and perfusion CT with respect to covariates known to influence radiation exposure and for the main clinical outcomes defined by the trial. The final analysis assessed variations in radiation dose with respect to several factors inherent to the trial. RESULTS. The mean radiation dose estimate for the combined CTA and perfusion CT protocol (8.63 mSv) was significantly (p < 0.0001 for both) less than the average dose delivered from SPECT (10.48 mSv) and the average dose from diagnostic catheter angiography (11.63 mSv). There was no significant difference in estimated CTA-perfusion CT radiation dose for subjects who had false-positive or false-negative results in the CORE320 main analyses in a comparison with subjects for whom the CTA-perfusion CT findings were in accordance with the reference standard SPECT plus catheter angiographic findings. CONCLUSION. Radiation dose estimates from CORE320 support clinical implementation of a combined CT protocol for assessing coronary anatomy and myocardial perfusion.


Assuntos
Absorção de Radiação , Angiografia Coronária/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Contagem Corporal Total/estatística & dados numéricos , Idoso , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Diabetes Care ; 28(5): 1145-50, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15855580

RESUMO

OBJECTIVE: The relationship between coronary endothelial function and insulin resistance remains speculative. We sought to determine whether pioglitazone, an insulin-sensitizing peroxisome proliferator-activated receptor (PPAR)-gamma agonist, improves cardiac endothelial function in individuals with type 2 diabetes. RESEARCH DESIGN AND METHODS: Sixteen subjects with insulin-treated type 2 diabetes and without overt cardiovascular disease were randomly assigned to receive either 45 mg of pioglitazone or matching placebo for 3 months. Rest and adenosine-stimulated myocardial blood flow (MBF) were quantified with [(13)N]ammonia and positron emission tomography at baseline and study conclusion. RESULTS: After 3 months, HbA(1c) levels dropped by 0.68% in the pioglitazone group and increased by 0.17% in the placebo group (P = 0.009 for difference between groups). Triglyceride (-93 vs. -39 mg/dl, P = 0.026) and HDL concentrations (+4.8 vs. -6.0 mg/dl, P = 0.014) improved significantly in the pioglitazone group compared with placebo. Despite these favorable changes, there was no demonstrable change in baseline MBF (-0.05 +/- 0.24 vs. -0.09 +/- 0.24 ml . min(-1) . g(-1), P = 0.45), adenosine-stimulated MBF (0.10 +/- 0.75 vs. 0.14 +/- 0.31 ml . min(-1) . g(-1), P = 0.25), or coronary flow reserve (0.45 +/- 1.22 vs. 0.35 +/- 0.72 ml . min(-1) . g(-1), P = 0.64) after 12 weeks of exposure to pioglitazone or placebo, respectively. Regression analysis revealed that lower glucose concentration at the time of the study was associated with higher coronary flow reserve (P = 0.012). CONCLUSIONS: Pioglitazone treatment for 12 weeks in subjects with insulin-requiring type 2 diabetes had no demonstrable effect on coronary flow reserve despite metabolic improvements. Higher ambient glucose levels contribute to impaired vascular reactivity in individuals with diabetes.


Assuntos
Circulação Coronária/efeitos dos fármacos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , PPAR gama/agonistas , Tiazolidinedionas/administração & dosagem , Adenosina/administração & dosagem , Idoso , Endotélio Vascular/efeitos dos fármacos , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Pioglitazona , Tomografia por Emissão de Pósitrons , Valor Preditivo dos Testes , Resistência Vascular/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA